| 1 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)(But without MCB / RCCB / Isolator) a) 6 way double door |
| 2 | b)12 way double door |
| 3 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) single pole |
| 4 | b) Double pole |
| 5 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 6 | Providing and laying GI tape 32mm x 6 mm fromGI strip earth electrode directly in ground as required. |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 50 sq. Mm |
| 8 | 2 X 16 sq. Mm |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked alomgwith all accessories like socket bend coupler etc. conforming to IS 14930 part 2 complete with fitting ,and cutting , jointing etc. in the existing trench ,complete as required .(i. 63 mm dia ) |
| 10 | Add labour cess @1% on value of DSRitems |
| 11 | Applicable rate of GST@18% (MF @ 0.0633) in place of 12 % on total value of DSR items after adding of labour cess |
| 12 | Dedcuct correction value after applying correction factor @ 0.973 on value of DSR items |
| 13 | SITC of outdoor type feeder piller, double door made out of 14 SWG CRCA sheet of size 1000 mm x 1000 mm x400 mm deep having 200 Amp, 4 Nos insulated aluminium bus bars and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires & angle iron frame of size size 1000 mm x 400 mm with 600 mm long mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required..(i) 125- Amps, 4 pole MCCB, 415 volts, 50 Hz-02 Nos (ii)100Amps, 4 Pole, MCCB, 415 volts, 50 Hz AC supply -1 Nos(iii)63 Amp,4 pole, MCCB, 10 KA, 415 V, 50 Hz = 02 Nos, (iv)40 Amp, DP, MCB, 10 KA, C curve, 240 V, 50 Hz = 04Nos. (v) 125 Amp on load change over -01 Nos. |
| 14 | SITC of outdoor type feeder piller, double door made out of 14 SWG CRCA sheet of size 800 mm x 800 mm x400 mm deep having 200 Amp, 4 Nos insulated aluminium bus bars and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires & angle iron frame of size size 800 mm x 300 mm with 600 mm long mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required..(i)100Amps, 4 Pole, MCCB, 415 volts, 50 Hz AC supply-01 (ii) 63 Amp, 4 Pole, MCB, 10 KA,C curve, 240 V, 50 Hz= 02 Nos,(iii)40Amp, DP, MCB, 10 KA,C curve, 240 V, 50 Hz -03. |
| 15 | Providing & fixing of following aceesories on existing feeder pillerincluding connection etc as required. (i)63 Amp, 4 pole MCCB , - 1 No(ii)40 Amp DP MCB-04 Nos. |
| 16 | SITC of outdoor type feeder piller, double door made out of 14 SWG CRCA sheet of size 800 mm x 800 mm x400 mm deep having 200 Amp, 4 Nos insulated aluminium bus bars and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires & angle iron frame of size size 800 mm x 300 mm with 600 mm long mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required..(i)100Amps, 4 Pole, MCCB, 415 volts, 50 Hz AC supply-01 (ii) 63 Amp, 4 Pole, MCCB, 10 KA,C curve, 240 V, 50 Hz= 02 Nos,(iii)63 Amp, 4 Pole, MCB, 10 KA,C curve, 240 V, 50 Hz= 01 Nos(iv)40Amp, DP, MCB, 10 KA,C curve, 240 V, 50 Hz -02. |
| 17 | SITC of outdoor type feeder piller, double door made out of 14 SWG CRCA sheet of size 600 mm x 600 mm x400 mm deep having 100 Amp, 4 Nos insulated aluminium bus bars and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires & angle iron frame of size 800 mm x 600 mm with 600 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required.(i)63 Amp, 4 Pole, MCCB, 10 KA,C curve, 240 V, 50 Hz -01(ii)40Amp, DP, MCB, 10 KA,C curve, 240 V, 50 Hz -05. |
| 18 | Supplying & laying of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV Grade of size 3.5 X 95 Sq. MM conf to IS: 7098 (Part-I)direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 19 | Supplying & laying of one numberXLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 3.5 X 95 Sq. MM conf to IS: 7098 (Part-I) in the existing OPEN duct/pipe as required. |
| 20 | Supplying & laying of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV Grade of size 3.5 X 50 Sq. MM conf to IS: 7098 (Part-I)direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 21 | Supplying & laying of one numberXLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 3.5 X 50 Sq. MM conf to IS: 7098 (Part-I) in the existing OPEN duct/pipe as required. |
| 22 | Supplying & laying of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV Grade of size 2 X 16 Sq. MM conf to IS: 7098 (Part-I)direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 23 | Supplying & laying of one numberXLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 2 X 16 Sq. MM conf to IS: 7098 (Part-I) in the existing OPEN duct/pipe as required. |