| 1 | M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as spd as directed |
| 2 | M&L 15mm thick rendering in cement mortar 1:4 to on brick masonary wall surfaces or on other than fair faces of brick masonary fairfinishedwithout using extra cement with using water proofing liquid complete all as specified and directed |
| 3 | M&L for preparation of newly plastered surfaces of walls and applying two coat of weather proof exterior emulsion paint over coat of 1mm thickof birla wall care putty complete all as specified and directed. (Note : Colour and patterns to be applied as per new colour scheme approved by Stn Cdr) |
| 4 | S&FPVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floorwith necessary fitting icomplete all as specified and directed. |
| 5 | M & L Providing cement concrete type B0 1:2:4 using 12.5mm agg in coping, kerbs or mud stops rounded edges completed all as specified and directed. |
| 6 | Excavation in Post holes (or similar holes ) in any type of soil, each not exe 0.5 cum , getting out , returning filling and ramming carts not exc 25cm , watering and removing surplus soil to a distance not exc 50 mtr and making good surface complete |
| 7 | M & L for Steel work in tubular hollow rectangular/Square trusses, purlins, rail including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade inluding one coat of zinc chromate primer before fabricationdistance pieces, cleats etc GDE Fe 410-S. complete all as specified and directed. |
| 8 | M & L Cement concrete type C2 (1:3:6 40 mm graded stone agg) in foundations, filling post hole and mass concrete complete all as specefied and directed. |
| 9 | S&F Pre-coated galvalume aluminium zinc coating GI based semi corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specefied and directed |
| 10 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coatof red oxide zinc chrome primer complete all as specified anddirected by Engineer-in-Charge. |
| 11 | Surface Excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep soft/loose soil and getting out complete all as specified and directed |
| 12 | Removing surplus excaveted soil to a distance exc 250 Mtr and nexc 500 Mtr depositing where directed at a level n. exc 1.5 Mtr above the starting point complete all as specified and directed. |
| 13 | M & L Hardcore with broken bricks of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface thick watered and rammed/rolled to a true surface to achieve required density complete all as specified. |
| 14 | M&L forrubber molded cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of60mm thickness, M-35 Grade,pattern and colour as approved by GE and over and inclduing 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings over 25 mm sand filling under flloors including watering and cosolidationall completed as specified and directed. |
| 15 | M&L for PCC (1:2:4) type B1 using 20mm graded agg for machine pressesd precast cement concrete kerb stone (300mm x 150mm x 300 mm) including weathering, slightly rounded or chemferred angles and throating, as directed edges complete including excavavtion for kerb stone and filling after embeded including watering and well ramming complete all as specefied and directedNote size is approved by GE. |
| 16 | M&Lfor Machine cut kota stone slab 20-25 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including Mirror polished wtihcomplete, over and including 20mm thick screed bed or bedding layer in cement mortar 1: 6, for laying floor finishes all as specified |
| 17 | M&L for 25 mm thick cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) in floors,finished rough to receive floor tiles complete all as specified and directed |
| 18 | Demolition of Concrete is ground floors and pavings n exc 15 cm thickness (below or above ground level) as specified and directed by Engineer-in-Charge. |
| 19 | M & L for Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil all as specified and directed. |
| 20 | M&L for 75 mm thick PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) as in sub base of floor. all as specified and directed. |
| 21 | M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15650 - 2008 of 80 mm thicknessM-40 grade with grey cement and pigment , shape and colour as approved by GE incl 25 mm thick sand cushioning for interlocking tiles complete all as specified and directed.. |
| 22 | M&Lfor providing and laying at or near ground level factory made kerb stone of M-25 grade (of size 300 mm x 300 mm x 150 mm) cement concrete in position to the required line, level and and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarde sand), including making joints with or without grooves (this\ckness of joints except at sharp curve shall not more than 5 mm), including making drainage opening whereever required complete all as specifed and directed |
| 23 | M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate as in cills, coping steps, bed blocks, tank staging, sesmic and other similar courses, lacing courses parapet and railing upto 60cm ht kneeler kerb and a like including weathering, slightly rounded or chemfered angle and throating all as specified and directed. |
| 24 | Removing of execavated material n exc 50m and depositing where directed at a level n exc 1.5 mtr above the starting point. all as specified and directed. |
| 25 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with cooling and heating function electric driven, single phase of capacity of 1.5 TR,complete all as specified and directed |
| 26 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA complete all as specified and directed |
| 27 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with cooling and heating function of 2 Toncapacitycomplete all as specified and directed |
| 28 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and directed |
| 29 | S & F Wall/floor mounting type iron stand for outdoor unitcomplete all as specified and as directed |
| 30 | S&F Sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC conduits of 20mm size including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 4 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note:- Two runs of 4 Sqmm (FRLS) and one run of 4 Sqmm (FRLS) copper conductor and one run of PVC Conduit shall be measured and paid sepeartely) |
| 31 | S&F miniature circuit breakers, type curve‘B’ , 10 KA, SP, 6 to 32 Amps complete all as specified and directed. |
| 32 | S &F sheet metal enclosure with socket plug top andMCBs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and directed. |
| 33 | Supply, installation, commissioning of Deep freezer glass top400 Litre capacity having double doorsingle phase 240 volt, 50 Hz complete all as specified and directed by the Engr-in-Charge. |
| 34 | Supply and fix desert cooler electric driven (single phase), made out of MS sheet not less than 22 gauge body suitable to accommodate exhaust fan turbo force 450 mm sweep 1400 RPM with high speed, water tank not less than 100 litre capacity and water pump to meet the requirement as per capacity of desert cooler with all internal pipes heavy duty threaded PVC pipe including honey combgrass pad 03 (three) nos superior quality and front grill made out of non corrosive material with 02 Nos (switch piano type) 6 Amps for fan and water pump and 01 No regulator step type suitable for exhaust fan capacity and internal wiring done using 2.5 sqmm copper conductor and 01 No float valve 15mm size with aluminium rod and PVC float and all accessories as required and connect the water supply from existing source and installed the same over existing platform/stand complete all as specified and directed. |
| 35 | M & L for Switch piano, flush type single pole, one way 6 Ampcomplete all as specified and directed. |
| 36 | M & L for Socket outlet 3 pin, 6A, flush typecomplete all as specified and directed. |
| 37 | Material and labour for point wiring with single corePVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes andcovered with 3 mm thick plastic laminated sheet coverof suitable size with new brass screwsfor mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with strandedcopper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:One socket point 05/06 A on independent board and controlled by one switch 06 Amps complete all as specified and directed. |
| 38 | S&F Steel work in trussed, purlins, crane gantries, rails and fastenings and bracket framingincluding distance pieces, cleats, nut bolts etccomplete all as specified and directed. |
| 39 | Supply and installation of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, incl fastener 75mm length with nut and bolt, complete all as spcified and directed. |
| 40 | Supply and fix PVC connections 15mm size hot and coldwith PTMT nuts of length 600mm, complete all as specified and directed. |
| 41 | Supply and Laying galvanised iron steel tubing pipe 15 mm bore, medium grade with all tubings (Such as bend, elbows, tees, short pieces of medium grade, connectors, back nuts, caps, plugs andunion etc) laying in trenches/floor/ducts and also cutting pipes, screwing for making forged bends on piping as required and complete all as specified. |
| 42 | M&L for Cutting existing steel tubing 25 mm bore for alterations or additions for inserting of tees complete all as specified and directed. |
| 43 | S&F of Bib Taps, fancy type, Cast Copper alloy with crutch or Butterfly handle, screwed downfor iron pipe of brass ferrule and fixed complete all as specified and directed. |
| 44 | S&F Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or forunions and fixed complete all as specified and directed. |
| 45 | M&L for point wiring with single corePVC sheathed 1100 volt grade cable with multi stranded copper conductor of size 2.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI markednot less than 20mm dia, with all conduit accessories, screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof) including pressed steel terminal sunken boxes andcovered with 3 mm thick plastic laminated sheet coverof suitable size with new brass screwsfor mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with strandedcopper conductor of size 2.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified and directed. |
| 46 | S&F Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed. |
| 47 | S&F Socket outlet 2 in 1, 6 pin, 15/5A flushtype complete all as specified and directed. |
| 48 | Excavation in trenches not exc 1.5 mtr width and not exce 1.5 mtr in depth in soft/loose soil and getting complete all as specified and directed. |
| 49 | Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 50 | Returning , filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and directed. |
| 51 | Supply and LayingXLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole complete of size 35 Sqmm 3.5 Core complete all as specified and directed. |
| 52 | M&L for sand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and directed. |
| 53 | M&L bricks with sub class \"B\" locally available laid in trenches above sand cushioning for cable protection complete all as specified and directed. |
| 54 | S&F of High galvanized mast light 16 meter height suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per height complete all as specified and directed. |
| 55 | Supply and fixing LED flood light 400 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 56 | Supply & fixing PVC insulated & sheathed stranded copper cable 5 core of cross sectional area 2.5 sq mm for proving necessary electrical connection from feeder pillar box to light fittings including with suitable size copper lugs complete all as specified and directed. |
| 57 | M&L for Galvanised Steel Tubing Pipe 40 mm bore (dia), light grade with Bend, laid in Trenches or under Roads crossing/Flooring/Culverts/Footpath complete all as specified and as directed. |
| 58 | M&L of Earthing with Galvanised Earth Plate Electrode 600x600x6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected to galvanised earth Strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) with Cast iron cover 10mm thick hinged, Cast Iron Frame, MS Rod 6mm, Funnel, GI Pipe 20mm medium grade all as shown in Electrical Plate No. 3 of MES Schedule Part-I including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and and Testing on Completion, complete all as per specified and as directed. |
| 59 | Supply, install, commissioning and testing cubical type outdoor type LT Panel box, made out of 3.15 mm thick mild steel sheet, of size not less than 600 mm x 500 mm x 300 mm with mild steel angle iron frame and legs (of length 400 mm) of section 40 mm x 40 mm x 6 mm thick, with front openable door (with locking arrangement) duly powder coat painted over a coat of red oxide primer,with provision of cable entry and exit at mid portion of the feeder pillar box (with cable gland), and providing one number Danger Notice Plate (of size 15 cm x10 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour, fixed with clamps and nuts-bolts of suitable size) and providing necessary foundation of the feeder pillar box in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) completeall as directed by the Engr-in-Charge comprising of the following accessories:- |
| 60 | (a)MCB, TPN 63 Amps, 50 Hz, 415 Volts- 01 Nos (b)Aluminium bus bar 100 Amps capacity - 04 Nos(c)LED type indication lamp R Y B - 01 set.(d) Contactor 40 Amps, 3 pole, 415 volts. AC - 01 No(e) Auto/Manual Selector Switch - 01No (f) ON/OFF Push Button - 01 No(g) Digital Time Switch, Din Type Astronomical Programmable every 1min, current capacity 16 Amps with 2 change over Note:-(i) All incoming and outgoing cables, duly thimbled along with suitable size of brass cable glands, to be connected with accessories. |