| 1 | M&L for Rendering/plastering, 10mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth (without using extra cement) including taking down cement plasterfrom brick walls of any description, racking out joints, hacking for key, scrubbing down with water & Preparation of new plastered surfaces wall and applying two coats of Oil bound distember over a coat of primer complete all as specified and directed. |
| 2 | M&L for 15mm thick rendering in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and fair (without using extra cement) including taking down cement plasterfrom brick walls of any description, racking out joints, hacking for key, scrubbing down with water & Preparation of new plastered surfaces and applying two coats of cement base paint over a coat of chalk white primer complete all as specified and directed. |
| 3 | Demolition of brick work built in cement mortar of any specification and in any position complete all as specified and directed. |
| 4 | M&L for Brick work in cement mortar 1:6 using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 metre mean radius complete all as specified and directed. |
| 5 | All as per item no 04 above but reuse bricks in any specification and in any position retrieved including cleaning and removal of mortar from old bricks, complete all as specified and directed. |
| 6 | M&L for Rendering/plastering, 10mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth (without using extra cement) & Preparation of new plastered surfaces wall and applying two coats of Oil bound distember over a coat of primer complete all as specified and directed. |
| 7 | M&L for 15mm thick rendering in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and fair (without using extra cement)& Preparation of new plastered surfaces and applying two coats of cement base paint over a coat of chalk white primer complete all as specified and directed. |
| 8 | M & Lfor preparing of olddecorated surfaces (plastered or un-plastered) by brooming down and applying one coat of white wash on walls including cornices, complete all as specified and directed. |
| 9 | M&L Complete removal of existing treatment of wall suface and applying two coats of oil bound distemper, over 2mm thick wall care putty, complete all as specified and as directed. |
| 10 | Complete Removal of existing treatment of walls applying two coats of cement based paint over one coat of chalk white primer on plastered surfaces all as specified and directed. |
| 11 | M&L for preparing old plaster surfaces of walls applying one coat of exterior emultion paint complete all as specified and directed. |
| 12 | Demolition of reinforced cement concrete concrete in any description and in any position not otherwise specifically provided for , complete all as specified and directed. |
| 13 | M&L for cement concrete type B1 1:2:4 using 20mm graded aggregate nominal mix in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 14 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) in rough finished flat concrete surfaces complete all as specified and directed. |
| 15 | S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | M&L for 40mm thick cementconcrete type B-1, 1:2:4 using 20mm graded aggregate in sub base in floors complete all as specified and directed. |
| 17 | M & L for non skid coloured ceramic tiles of7 to 8 mm thick, area of each tile exceeding 0.18 sq m but not exceeding 0.36Sq min floors set and jointed in neat cement slurry and pointed in white cementmixed with colour pigment to match over a screed layer of 15 mm thick in CM 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed. |
| 18 | M & L for non skid coloured ceramic tiles of7 to 8 mm thick, area of each tile exceeding 0.18 sq m but not exceeding 0.36Sq m as in skirting/dadoset and jointed in neat cement slurry and pointed in white cementmixed with colour pigment to match andbacking coat 10 mm thick in CM 1:4 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed. |
| 19 | S/F of Glazed coloured and cereamic tiles in vertical surfaces 300X200X7mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over backing coat 10mm thick in cement mortar 1:4 for laying skirting dados and vertical surfaces including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises all as specified and directed |
| 20 | Demolition of Stone slabs and tiles laid bedded pointed in mortar of any description or thickness in floors, aprons etc, complete all as specified and directed. |
| 21 | M & L for 16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 22 | M&L Machine pressed precast conctete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement and no pigment used, excluding laying ofsand cushioning complete allas specified and as directed.Note :- Sand will be measured and paid seperately |
| 23 | M&L for 100mm thick cement concrete type D- 2, 1:4:8 using 40mm graded aggregate in sub bases in floors, hardstanding complete all as specified and directed. |
| 24 | M&L sand filling under floors or in foundations including watering and consolidation complete allas specified and as directed. |
| 25 | Cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in filling of steel chowkhats,bed blocks, coping, hold fasts, purlin blocks etcincluding necessary form work complete all as specified and directed. |
| 26 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Sqm each complete all as specified and directed. |
| 27 | All as per item No 26 herein before but size exceeding 1.5 Sqm and not exceeding 4 Sqm each, complete all as specified and directed. |
| 28 | S&F for Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified and directed. |
| 29 | All as per item no 28 above here-in-before but size 125x60mm with double rebate, complete all as specified and directed. |
| 30 | Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010), complete all as specified and directed. |
| 31 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed. |
| 32 | PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified and directed. |
| 33 | PTMT butt hinge, 100mm long,fixed with steel screws with brass/bronze hinge pin complete all as specified and directed. |
| 34 | PTMT handle 125mm long fixed with steel screws complete all as specified and directed. |
| 35 | S&F 30mm thick second class hard wood plain framed panelled shutters(any number of panels ), with panels of timber flat on both sides (feather edge), or of veneered particle board medium density wood wood particle board with commericial face veneers and fitted to chowkats, complete all as specified and directed. |
| 36 | S&F 30mm thick second class hard wood glazed and skelton shutters,open rebated and prepared to receive glass gauze,etc (without sash bars),edges of framingplain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I section 8 clause 8.24(a) fitted to chowkat, complete all as specified and directed. |
| 37 | S & F Factory made double rebate box type side hung steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle, with & Without glazing bars, one side wiremesh shutter without glazing bar & other side glass shutter with glazing bar including 6mm mild steel guard bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07. Note : Wiremesh and glass will be measured seperately |
| 38 | S&F Factory made box type steel ventilator with glazing bars dovetailed or welded,grills/guard bars shouldered with steel ventilator frames and with one shop coat of zinc chromate primer complete all as specified and directed. |
| 39 | M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed |
| 40 | M&L Preparation of new wooden or wood based surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 41 | S&F 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work, including dismantling of boarding, any description, fixed in any position complete all as specified and directed |
| 42 | S&F for continuous (piano) hinges, mild steel bright finish or electro galvanised with flap (when open) 40 mm, fixed with steel screws complete all as specified and directed. |
| 43 | S&F in repair Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified and directed. |
| 44 | S&F 3mm thick, plainsheet glass ordinary quality and glazing,with oil putty or with wooden beads(supplied alongwith shutters), in squares n.exc 0.50 Sqm complete all as specified and directed. |
| 45 | S & F Galvanised mild steel wire cloth0.48mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed. |
| 46 | S&F 150mm long aluminium, anodisedbarrel tower bolts of extruded section, all as specified and as directed by the Engr-in-charge. |
| 47 | S&F 100mm Extruded aluminium alloy handleall as specified and as directed by the Engr-in-charge. |
| 48 | S&FAluminium alloy, anodised, sliding door bolt 250mm length,with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed. |
| 49 | S&F 300mm mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 50 | S&F in repair 20mm dia harrison/ curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc all as specified and directed by Engineer-In-Charge. |
| 51 | S&F galvanised steel water tubes 15 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors including taking down corroded GI pipe complete all as specified and as directed by Engr-in-Charge. |
| 52 | S&F for unplasticised 15mm dia PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipeincluding taking down corroded GI pipe complete all as specified and as directed by Engr-in-Charge. |
| 53 | S&F galvanised steel water tubes 20 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors including taking down corroded GI pipe complete all as specified and as directed by Engr-in-Charge. |
| 54 | S&F in repair PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc and fixed complete all as specified and directed. |
| 55 | S&F in repair 15mm bore stop valves/ angle valve CP of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup complete all as specified and directed. |
| 56 | S&Fin repair125mm dia CP brass shower rose with or without swivel joints, any size including fixing to steel pipe or union complete all as specified and directed. |
| 57 | S&Fin repair CP fancy type Bib tap, 15mm bore, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 58 | S&F in repair 15mm bore fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 59 | S&F Rotational moulded Polyethylene water storage tank of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm PVC float valve high pressure with polythene float valve & Dismantling water tanks and removing to store complete allas specified and as directed |
| 60 | S/F gunmetal gate valve of 20mm dia with iron wheel head screwed both ends for iron pipe andas fixedin repairs, complete all as specified and directed. |
| 61 | S&F PVC connection both end brass union and length 450 mm long for 15 mm bore pipe complete all as specified and directed. |
| 62 | S&F CP tubular towel rail, 20mm dia, D type, 60cm long between flanges as fixed all as specified and directed. |
| 63 | S&F Vitreous china white squatting pan orrissa pattern of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, fixed as in repair, complete all as specified and directed. |
| 64 | S&F Wash hand basin, pedestal type flat back 550 x 400mm vitreous china (white) including PTMT waste fittings, 32mm bore size, waste pipe, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing as in repair complete all as specified and directed. |
| 65 | S&F for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 66 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed to walls including taking down eaves gutters and rain water pipes (any size or pattern),including all fittings heads shoes bends swan-necks etc complete all as specified and directed. |
| 67 | S&F for 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 68 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed to walls including taking down eaves gutters and rain water pipes (any size or pattern), including all fittings heads shoes bends swan-necks etc complete all as specified and directed. |
| 69 | S&F 75mm dia PVC (SWR)with access door bends any radius, complete all as specified and directed. |
| 70 | S&F 110 mm dia PVC (SWR)with access door bends any radius, complete all as specified and directed. |
| 71 | Dismantling of wall and ceiling boards (Fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 72 | S & F for Hollow PVC wall lining consisting of 5mm thick single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement and fixing on PVC frame as per specified in MES schedule part-I & II complete all as specified and directed by Engineer in Charge . |
| 73 | S & F for Gypsum Board 8 mm thick in ceiling fixed with screw 60x60cm placed in ceiling (Angle 25mm X 25mm , Main tee 38mmX23mm ,Sub tee 23mmX23mm) incl mild steel snap grid frame 605X605 mm for false ceiling incl hanging arrangement complete all as specified and directed by Engineer in Charge. Note:-The hanging stay wire shall not be less than 4.00mm thick all are included in the above mentioned item only. |
| 74 | Dismentlling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and directed. |
| 75 | Excavating in post holes(or similer holes)each n exc 0.5 cum getting out,returning filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 76 | M&L for cement concrete type C-2, 1:3:6 using 40mm graded stone aggergate as in foundations filling and mass concrete complete all as specified and directed. |
| 77 | S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc using Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engr-In-Charge. |
| 78 | Dismantling asbestos cement (corrugated or semi corrugated) sheets and S&F Pre painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screwsin roofing complete all as specified and directed. |
| 79 | Dismantling wrought iron work or mild steel work of any description and S&F Framed mild steel work of grade E-165 (Fe-290) as in framed work such as doors, gates or frame for cooler stand with gusset plates, rails, braces etc, drilled for fixing of sheeting or other covering of door etc, to be prepared for hanging or sliding etc including either hooks and hinges or steel hanging door fittings and hanging and fixing complete all as specified and directed |
| 80 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 81 | S&F for anodised aluminium frame for doors, windows, ventilators and patations with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 82 | S&F for 10mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed. |
| 83 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as direced by Engr-in-Charge. |
| 84 | M&L for PCC type D2, 1:4:8 (40 mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge. |
| 85 | Returing, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soill, complete all as specified and directed. |
| 86 | Removing excavated material as soil exc. 50 m and n.exc 250 m, depositing where directed at a level n.exc. 1.5m above the starting point, complete all as specified and directed. |
| 87 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete i.e. PCC (1:3:6) and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wires, etc, flat iron fillets(for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc and similer work conforming to Fe-290 Gde E-165 (For Fencing), complete all as specified and directed. |
| 88 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in lintels upto1.5m clear span,cills,steps; seismic and other similar bands, coaping, plinth courses, benching, water troughs and the like including weathering,slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and directed |
| 89 | M&L for 40 mm thick damp proof course in cement concrete 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed |
| 90 | S&F galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainging bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc,complete all as specified and directed (each line wire to be measured). |
| 91 | Taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete withfitting and fixtures such as switches, sockets, c/rosess, holders and bracket fittings with battens / conduits / wires, T/L fittings and making good the disturbed surfacesof walls and roofs etc and to match with existing colour complete all as specified and directed. |
| 92 | Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB\"s (single phase or three phase) of any capacity all as specified and directed. |
| 93 | S&FPoint wiring complete with 1100 volts grade PVCFRLSinsulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly complete all as specifiedforfollowing : (a)One light/fan/bell/Bldg security light point controlled by one single pole one way switch. Make:- Plaza, Seewel, Anchor & SCI. |
| 94 | All as per item No. 93 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board, complete all as specified and directed. |
| 95 | All as per item No. 93 here-in-before but One 3 pin 5 Amp socket outlet point controlled by one switch on sameboard, complete all as specified and directed. |
| 96 | All as per item No. 93 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC FRLS insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC FRLS insulated, unsheathed, stranded copper conductor cable, complete all as specified and directed. |
| 97 | All as per item No. 93 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC FRLS insulated, stranded, unsheathed copper conductor on independednt board with continuous earth wire of size 4.0 Sqmm green colours PVC FRLS insulated, unsheathed, stranded copper conductor cable, complete all as specified and directed. |
| 98 | S&F switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 99 | S&F Switch piano flush type, 15 Amp, single pole, one way, 240 volts complete all as specified and directed. |
| 100 | S&F socket outlet flush type, multipupose, 3 pin 5 Amp complete all as specified and directed. |
| 101 | S&F socket outlet flush type, multipurpose 2 in 1,3 pin 5 & 15 Amp, 240 volts complete all as specified and directed. |
| 102 | S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals dulyISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 103 | S&F batten holder 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed. |
| 104 | S&F rotary stepped type electronic fan regulator compatible for BLDC for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 100W, deluxe, white in colour, duly ISI marked complete all as specified and directed. |
| 105 | Supply and fixing LED light fitting 1 x 20 Watt, 220V, AC decorative type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 106 | S&F LED bulb of 9/10 watts B-22 CDL 3 star 6500K, complete all as specified and directed. |
| 107 | S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 108 | S&F MCB SPN, 40A - 63Amps, 240 volts, \"C\" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning, complete all as specified and directed. |
| 109 | S&F MCB SP, 6A-32 Amps, 240 volts, \"B\" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning, complete all as specified and directed. |
| 110 | S&F LED Bldg Security Light toughened glass of 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp incl suitable size MS/ GI bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and directed.Make:- Bajaj, Havells and Philips. |
| 111 | M&L for Earthing complete, all as shown on electrical plate No 3 of MES schedule part-I , as specified including the following :-(i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick burried directly in ground vertically to a depth not less than 2.25 metrebelow ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level. (ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer). (iii) 4 mm dia (8 SWG) G.I earth wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc. (iv) 15 mm bore light grade, GI pipe forprotection to earth-wire. (v) 20mm bore, medium grade, GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate,Chamber in PCC(1:3:6), type-C2(to be constructed 1 m away from edge of earth pit)and MS angle iron 50x50x6mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces. (vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed including testing etc all as specified. |
| 112 | M& L for Sand cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. |
| 113 | Supply and laying well burnt, sub class \"B\" brick oldsize for cable protection complete all as specified and directed. |
| 114 | Material & labour for boring hole under the road/ payment/ hard standing upto 50 mm Bore Pipenot less than one metre below ground level complete all as specified and directed. |
| 115 | Supplying, laying and connecting XLPE insulated and sheathed armoured 1100 volts grade heavy duty electric cable with multistranded aluminium conductor laid in trenches/duct through pipe, in floor on poles in and including aluminium thimble or aluminium line tape of size 16 sq mm 2 core nominalcross section area Complete all as specified and directed by Engr-in-Charge. |
| 116 | S&F Mild steel galvanised pipe, light grade, 50 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc complete all as specified and directed. |