| 1 | Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed. |
| 2 | Taking down old U/S existing DB SPN 8 way & TPN DB 4 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. |
| 3 | Disconnecting and taking down unserviceable submain wiring form TPN DB to SPN DB and SPN DB 8 way to SPN DB 4 Way complete & removing U/S items from site complete all as directed by Engineer-in-Charge. |
| 4 | Taking down the old unservicable Fan Regulator from site complete all as directed by Engineer - in charge |
| 5 | Taking out carefully earthing set complete of any type including earthing wire & removing U/S items from site complete all as directed by Engineer-in-charge. |
| 6 | M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colourto coomon earth dolly laid/drawn into and includingnon metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in& including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed:Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE |
| 7 | One light/fan point (Ceiling Fan/Exhaust Fan) controlled by oneswitch |
| 8 | One multi pin socket 5/6Amps,Independent. |
| 9 | One 5/6 amp socket outlet on the same boardcontrolled by another switch. |
| 10 | All as per item No 6 here -in- before but forone 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 sqmm single corePVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed . |
| 11 | S&F switch Modular type, 5/6 Amp, 1 module single pole one way, 230 Volts, Modulartype complete all as specified and as directed by Engr- in -charge. |
| 12 | S&F switch Modular type, 15/16 Amp, 1 module single pole one way, 230 Volts, Modulartype complete all as specified and as directed by Engr- in -charge. |
| 13 | S&F socket outlet 3 Pin5/6 Amps modular type, 2/3 pin combined 2 module230 Voltscomplete all as specified and directed by Engr-in-Charge. |
| 14 | S&F socket outlet 3 Pin6/16 Amps modular type, 2/3 pin combined 2 module230 Voltscomplete all as specified and directed by Engr-in-Charge. |
| 15 | S&F ceiling rose, surface backelite , three terminal AC, 230 voltcomplete all as specified. |
| 16 | Taking down Ceiling fan,sealing cable end, dismantling blades of any make, any sweep deposited to the store yard of AGE E/M (N) Bikaner for further disposal off / BER all as specified and directed by Engr-in-charge |
| 17 | Supply and fixing fan step regulator modular type , 120W-2 module electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-in-charge. |
| 18 | Supply &Fixing Exhaust Fan(Heavy Duty) Steel Body AC Single phase 230 volt , 50 hz 900 RPM , size 300 mm sweap with blades and frame including new modquito stainless steel wire mesh of gauge 0.36 mm with suitable wooden fram protection against birds etc including provision of cutting of existing wall for suitable to opening as per fan including electric connection with & including new 1.5 Sqmm 2 core flexible copper conductor cable from ceilling rose to fan , fan hanging on wall with 04 Nos steel fasteners 10 mm Dia 100 mm long and making good disturbed surface with cement mortar complete as specified and as directed by Engineer-in-charge . Note :- (i) SI NO as issued by Engineer-in-charge of Exhaust Fan and GE Office name shall be written on Exhaust fan with redcolour marker , cost for the same shall deemed to be included in quote unit rate. Nothing shall be paid extra on this account. |
| 19 | Supply and fixing fan step regulator modular type,120W -2 module electronicsocket typefive step controlled 230V AC 50 Hz forcomplete all as specified and directed by Engr-In-Charge. |
| 20 | Taking downLED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 21 | Refixing LED tube light fitting, 1x 20-22watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 22 | Supply and fixing LED light fitting mirror type with high out diffuser 2 feet , 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 23 | M & L Lamp holder , PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engr-in-charge |
| 24 | Supply and fixing LED Bldg Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and directed by Engr-in-charge |
| 25 | S&F GI bracket made out of 40 mm bore GI pipe light grade /medume grade, ISI marked, medium grade 1.2m long bent to shape suitable for fixing of street light fitting including with 2 Nos MS clamps made with 40x3mm flat iron, bolts, nuts, washers etc including two coats of synthetic enamel paint over one coat of zinc chrome primer and fixing on electric pole complete all as specified and as directed by Engr-in-Charge. |
| 26 | S & F double door, sheet metal enclosure,powder coated for MCB DB TPN DB 4 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. |
| 27 | S & F double door, sheet metal enclosure,powder coated for MCB DB SPN 8 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. |
| 28 | S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 29 | S & F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 30 | S & F MCB TPN 40-100Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 31 | M & L for sub main wiring with 2 runs of6.0 Sqmm(nominal area)size main cable &1 runs of 6 Sqmm size earth continuity conductor single core PVC insulated unsheathed cable multi-stranded FRLS copper conductor 1100 volt gradeISImarked cable drawn through and including suitable size of heavy duty non metalic rigid PVC concealed conduit ISI marked & conduit fittings/accessories, fixede concealed in wall/ceilling including dismantling &taking down old unservicable sub main wiring complete all as specified &directed(Note:(i) 02 runs of 6.0Sqmm size main cable , 01 run of 6 Sqmm size earth continuity conductor cable & Conduit with accessories shall be measured as one run for payment purpose (ii) Cost of cutting/leaving forming chases for conduits and making goodin CM 1:4 shall be included in quoted rate of this item. |
| 32 | M & L for sub main wiring with 2 runs of 10.0 Sqmm(nominal area)size main cable &1 runs of 6 Sqmm size earth continuity conductor single core PVC insulated unsheathed cable multi-stranded FRLS copper conductor 1100 volt gradeISImarked cable drawn through and including suitable size of heavy duty non metalic rigid PVC concealed conduit ISI marked & conduit fittings/accessories, fixede concealed in wall/ceilling including dismantling &taking down old unservicable sub main wiring complete all as specified &directed(Note:(i) 02 runs of 10.0Sqmm size main cable , 01 run of 6 Sqmm size earth continuity conductor cable & Conduit with accessories shall be measured as one run for payment purpose (ii) Cost of cutting/leaving forming chases for conduits and making goodin CM 1:4 shall be included in quoted rate of this item. |
| 33 | M & L for sub main wiring with two single core 4.00 Sqmm PVC insulated unsheathed cable multi-stranded FRLS copper conductor drawn through and including PVC conduit pipe of suitable size not less than 25mm with all fittings and fixing accessories on roof, walls, ceiling etc. including 4.00 Sqmm PVC insulated unsheathed single core solid copper conductor earth wire complete including taking down old sub main wiringall as specified and directed (Note:(i) Two run of single core cable and one run earth wire, pvc Conduit will be measured as one length)(ii) Cost of cutting/leaving forming chases for conduits and making goodin CM 1:4 shall be included in quoted rate of this item. |
| 34 | M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion. |
| 35 | Taking down Ceiling fan,sealing cable end, dismantling blades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing of ceiling fan, cleaning all dust & painting with existing colour synthetic enamel paint by spraying including filling cavities with filler,one coat including writing MES No. all as specified and directed by Engr-in-charge |
| 36 | S&F LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make :Philips-BN021 LED 20S PSU CW GR S2/ Crompton Greaves LDDR20-CDL Dazzle Ray / bajaj-BCLAB 20W |
| 37 | S&F LED Bulb 9W, operating voltage- 220-240 volts, starting time < 0.5s, color temperature-6500K, lumens: min 825 complete all as specified and directed by Engineer-in-charge. |
| 38 | Taking down old U/S existing DB SPN 8 way & TPN DB 4 way including MCB/MCCB/Sheet Metal enclosure plug socketof any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. |
| 39 | M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colourto coomon earth dolly laid/drawn into and includingnon metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in& including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed:Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE |
| 40 | One Light/fan/Ex-fan point controlled by one switch. |
| 41 | One multi pin socket 5/6 Amp , Independent. |
| 42 | One multi pin socket 5/6 Amp , Same board . |
| 43 | Taking down Exhaust fan,sealing cable end, dismantling blades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing of ceiling fan, cleaning all dust & painting with existing colour synthetic enamel paint by spraying including filling cavities with filler,one coat including writing MES No. all as specified and directed by Engr-in-charge |
| 44 | Earthing complete with galvanised perforated steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 6mm dia galvanised iron or steel wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -2 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion. |
| 45 | Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m width for laying of cable lines etc and getting out in hard/ dense soil all as specified and directed by Engr-in-charge. |
| 46 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge. |
| 47 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and directed. |
| 48 | Supply and Laying Double wall corrugated pipe(DWC pipe, Specification-120 mm OD/103 mm ID) for laying XLPE LT UG cable by DWC pipe throughout the LT cable length in pieces of convenient lenth .(Note : in pieces for easy rectification during fault ). |
| 49 | Supply and fixing GI Pipe light grade of Size 40 mm bore with all fittings for passing of cables fixed to pole/wall/laid under floor or roads including all fixing accessories complete for protection of cable all as specified and directed. Make: Jindal/ Bansl/Tata |
| 50 | Excavating in trenches, n exc 1.5 m wide, or n exc 10 sq m on plan, depth exc 1.5 m but n exc 3.0 mfor foundation, etc. or for laying of cables, poles , pipes etc. and getting out in soft/loosesoil complete all as specified and directed.Note :- Entire excavation shall be carried out manually only. No machinery such asJCB / excavator shall be used for excavation to avoid damage of existing electric supply / water supply / signal assets. This aspect shall be noted while quoting the Bid. |
| 51 | Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cms complete allasspecifiedanddirected. |
| 52 | Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc . 1.5M above the starting point all as specified and directed by Engr-in-charge |
| 53 | Supplying and laying reinforced precast concrete cable cover class LV, Type 1, flat, size 250mmx l50mm x 40mm tothelengthofcable complete allasspecifiedanddirected. |
| 54 | Supplyandlayingdryriversandlaidintrenchesascablecushioningandcovering complete allasspecifiedanddirected. Note : Punned thickness only measured and paid |
| 55 | Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty,galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 25 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable glandjoint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed. Note : Earth works, sand cushioning,bricks,GI pipes etc will be measured and paid under respective items. |
| 56 | Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty,galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 70 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable glandjoint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed. Note : Earth works, sand cushioning,bricks,GI pipes etc will be measured and paid under respective items. |
| 57 | Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty,galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 240 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable glandjoint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed. Note : Earth works, sand cushioning,bricks,GI pipes etc will be measured and paid under respective items. |
| 58 | Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty,galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 630 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable glandjoint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed. Note : Earth works, sand cushioning,bricks,GI pipes etc will be measured and paid under respective items. |
| 59 | S & F intrench/on wall in repairs GItubing light grade 150 mm dia for road crossing and cable protection etc complete all as specified and directed by Engr In Charge. |
| 60 | Boring holes horizontally under road with out damaging the surface of road (Min 1 mtr below the road surface with the help of GI tubing not exe 80mm bore (dia) for passing UG cable complete all as specified and as directed. Note : GI pipe shall be measured and paid under respective items. |