Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCH \"A\" PART-I TO XIII:Note: These schedules are pre-priced by MES and the rate indicated as \"Rs 0.00\" under Col 6 signifies this fact only |
| 2 | Total amount of Sch ‘A’ Part I (Building & Structures) |
| 3 | Total amount of Sch \"A\" Part-II (Site clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch ‘A’ Part III (Internal Water supply) |
| 5 | Total amount of Sch ‘A’ Part IV (Internal Electric Supply) |
| 6 | Total amount of Sch \"A\" Part-V (Road/Path & Culverts) |
| 7 | Total amount of Sch ‘A’ Part VI (Sewage Disposal) |
| 8 | Total amount of Sch ‘A’ Part VII (Area Drainage) |
| 9 | Total amount of Sch ‘A’ Part VIII (Fencing) |
| 10 | Total amount of Sch \"A\" Part-IX (External Water Supply) |
| 11 | Total amount of Sch \"A\" Part-X (External Electrification) |
| 12 | Total amount of Sch \"A\" Part-XI (Cooling Appliances) |
| 13 | Total amount of Sch \"A\" Part-XII (Solar Water Heater) |
| 14 | Total amount of Sch \"A\" Part-XIII (Rain Water Harvesting) |
| 15 | SCHEDULE \"A\" PART-XIV (MISC B/R ANDE/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as \"Rs 0.00\" under Col 6 signifies this fact only. |
| 16 | EARTHWORK |
| 17 | M&L Earth work in excavation in any kind of soil by mechanical means (Hydraulic excavator)/ manual means, in Over Areas or drains not exceeding 1.5 m in depth (not exceeding 1.5 m in width or 10 Sq.M on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil complete all as specified. |
| 18 | M&L Earth work in excavation in any kind of soil by mechanical means (Hydraulic excavator)/ manual means in Over Areas or drains exceeding 1.50 m depth but not exceeding 3.0 m in depth (not exceeding 1.5 m in width or 10 Sq.M on plan), including dressing of sides and ramming of bottoms including all lift and getting out the excavated soil complete all as specified. |
| 19 | M&L Earth work in excavation in any kind of soil by mechanical means (Hydraulic excavator)/ manual means in Over Areas or drains exceeding 3.00 metric tonne depth but not exceeding 4.50 metric tonne in depth (not exceeding 1.5 m in width or 10 Sq.M on plan), including dressing of sides and ramming of bottoms including all lift and getting out the excavated soil complete all as specified. |
| 20 | M&L Earth work in excavation in any kind of soil by mechanical means (Hydraulic excavator)/ manual means, in foundation trenches or drains not exceeding 1.5 m in depth (not exceeding 1.5 m in width or 10 Sq.M on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil complete all as specified. |
| 21 | M&L Earth work in excavation in any kind of soil by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains exceeding 1.50 m depth but not exceeding 3.0 m in depth (not exceeding 1.5 m in width or 10 Sq.M on plan), including dressing of sides and ramming of bottoms including all lift and getting out the excavated soil complete all as specified. |
| 22 | INTERNAL WATER SUPPLY |
| 23 | S&F Two way bib tap 15mm bore Chromium plated fancy type with crutch orbutterfly handle fixed to fixed to 15 mm bore/dia of pipe, complete all as specified and directed. |
| 24 | S&F Brass CPfor mixing hot & cold water screwed down for iron pipe and fixed to 15 mm bore/dia of CPVCpipe complete all as specified and directed. |
| 25 | INTERNAL ELECTRIFICATION |
| 26 | Supply and fixing of Modular 20 Amp, Mini MCB SP C Curve, AC 230 Volts, laser marking,ISI marked complete all as specified and directed. |
| 27 | Supply and fixing of modular type telephone socket RJ 11 with Shutter 1module, laser marking complete all as specified and directed. |
| 28 | Supply and fixing of modular type TV socket, 1module complete all as specified and directed. |
| 29 | Supply and fixing of LED round shape 20 watt 220 volts AC surface mounted type with high efficacy PMMA diffuser soft glare free light complete with drivers, clamps and suitable size as per ground requirement complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
| 30 | Supply and fixing of Decorative wall light fitting made up of polycarbonate and aluminium body suitable for and including 10 watt LED lamp complete all as specified and directed. |
| 31 | Supply and fixing of TV cable RG-6 coaxial cable (for TV cable, satellite and internet) complete including connector and drawn through in and including PVC heavy duty concealed conduit of suitable size complete all as specified and directed |
| 32 | Supply and fixing of Telephone cord cable landline wire with standard RJ-11 plug complete including plug and drawn through in and including PVC heavy duty concealed conduit of suitable size complete all as specified and directed |
| 33 | Supply and fixing of sheet metal enclosure (factory made), TPN Vertical Distribution Boards (MCCB Incomer) IP43 protection Double Door : Plain 4 way with 200 Amps rated busbar all as specified and directed. |
| 34 | Supply and fixing of sheet metal enclosure (factory made), TPN Vertical Distribution Boards (MCCB Incomer) IP43 protection Double Door : Plain 8 way with 200 Amps rated busbar all as specified and directed. |
| 35 | Material and labour of MS box of size 130x120x30 cm depth, dust proof with front opening hinged door both side, made out of 2mm thick MS sheet cubical type with powder coated painting for mounting of MCCB, DB\"s, electric meter etc inside the box fixed in wall by necessary cutting of wall of suitable size in concealed and making good the surface, including necessary electric connection by suitable size of copper conductor cable of suitable length and testing completed all as directed. |
| 36 | Supply, installation, tesing & commissioning of maximum 20W LED IP 20 batten with extruded aluminium housing in Anodised finish, minimum system lumen 2000 Lumen in 20W THD<20%,CRI>80, CCT=6500K,high surge protection 4 KV and operating temperature 00C to +450C,Integrated LED driver offers comfortable soft light, high durability driver safety requirement standards as per IS 15885-2 -13.T, complete all as specified and directed. |
| 37 | Supply, installation, tesing & commissioning of maximum 10W LED IP 20 batten with extruded aluminium housing in Anodised finish, minimum system lumen 1000 Lumen in 10W THD<20%,CRI>80, CCT=6500K,high surge protection 4 KV and operating temperature 00C to +450C, Integrated LED driver offers comfortable soft light, high durability driver safety requirement standards as per IS 15885-2 -13.T, complete all as specified and directed. |
| 38 | S&F Pop up box with 06 Modules for conference table which include 2 Nos 6 Amps Modular Sockets and 2 Nos 6 Amps Modular switch complete all as specified and directed. |
| 39 | COOLING APPLIANCES |
| 40 | Supply and install wall mounted SplitAir Conditioner capacity 1.5 TR, Inverter type(Hot & Cold) with indoor & outdoor, 3 star rated and SEER 3.8 or more ,R-32 refrigerant, Rotary compressor, Voltage range 220-240V,100% copper, cordless remote control, Auto Restart ,Night glow buttons, Self Diagnosis, Hot & Cold ,Convenience features like 5 in 1 Convertible modes, Low Gas Detection, Cleaning Filter Indication, electric cable with Top, supply and discharge copper tube upto 3 RM with inbuilt air filters ,Anti bacteria filter, Anti-Viral dust filter (PM 2.5 Filter) ,Auto air swing complete all as directed.Note :- The rate is included for following item-:(a) All other connected civil worklike hole cutting & other misc work required for installation of split AC for proper functioning as directed by EIC. including making good disturbed surfaces as per existing.(b) S&F PVC pipe 15 mm dia transparent flexible heavy duty for water drainage pipe ofupto 06 RMat site.(c) S&F copper pipe as per site requirement with insulation of complete pipe with PVC casing & capping of size 75 x 75 mm/required size for mechanical protection complete.(d) S&F Wall mounted stand for outdoor unitas suitable forfixing of AC. |
| 41 | Supply and install wall mounted SplitAir Conditioner capacity 2 TR, Inverter type(Hot & Cold) with indoor & outdoor, 3 star rated and SEER 3.81 or more ,R-32 refrigerant, Rotary compressor, Voltage range 220-240V,Power consumption 890W,100% copper, cordless remote control, Auto Restart ,Night glow buttons, Self Diagnosis, Hot & Cold ,Convenience features like 5 in 1 Convertible modes, Low Gas Detection, Cleaning Filter Indication, electric cable with Top, supply and discharge copper tube upto 3 RM with inbuilt air filters ,Anti bacteria filter, Anti-Viral dust filter (PM 2.5 Filter) ,Auto air swing complete all as directed.Note :- The rate is included for following item-:(a) All other connected civil worklike hole cutting & other misc work required for installation of split AC for proper functioning as directed by EIC. including making good disturbed surfaces as per existing.(b) S&F PVC pipe 15 mm dia transparent flexible heavy duty for water drainage pipe ofupto 06 RMat site.(c) S&F copper pipe as per site requirement with insulation of complete pipe with PVC casing & capping of size 75 x 75 mm/required size for mechanical protection complete.(d) S&F Wall mounted stand for outdoor unitas suitable forfixing of AC. |
| 42 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% including Digital Display and time delay systemand of capacity 4 KVA |
| 43 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% including Digital Display and time delay systemand of capacity and of capacity 5 KVA |
| 44 | Supply, Install ,testingand commissioning refrigerators, electric driven (single phase) ,capacity 195 liters ,5 star rated complete all as specified and as directed by Engineer-in-Charge |
| 45 | EXTERNAL WATER SUPPLY |
| 46 | Supply, laying, jointing,testingpipe ductile Iron 100 mm dia,pressure pipe with spigot and socket ends ,Class “K-9” confirming to IS:8329/2000 suitable for push on rubber gasket jointing with centrifugally applied inside cement mortar lining with portable slag cement as per IS : 455: 1989and external metallic zinc coating with finishing layer of bituminous coating including EPDM rubber joint complete all as specified and directed. |
| 47 | S & F DI fitting for spigot and socket/flanged ends pipe likeBends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth suitable for 100 mm dia pipe complete all as specified and directed. |
| 48 | M & L for Cutting to existing CI pipe line upto 150 mm dia for taking connection up to 100 mm dia DI pipe including insertion of CI Teecomplete all as specified and directed. |
| 49 | M & L for Cutting to existing CI pipe line upto 150 mm dia for taking connection up to 50 mm dia GI pipe including insertion of CI Teecomplete all as specified and directed. |
| 50 | Construction valve chamber with Fly Ash Bricks masonry of size 120 cm x 120 cm x 120 cm (internal dimension) with 15 cms thick foundation using PCC (1:4:8), type D2, using (40 mm graded stone aggregate), 23 cm thick brick walls built in cement mortar (1:6), 10 mm thick plaster in cement mortar (1:4) on internal and external surface (above ground level), finished even and fair without using extra cement 5mm thick MS sheet cover including 40 x 40 x 6 mm thick angle iron frame fixed on 150 mm thick PCC (1:2:4), type B1, using 20 mm graded stone aggregate) as in including 25 mm x 6 mm flat iron hold fasts, handles, hinges with locking arrangement and applying two coats of synthetic enamel paint over one coat of red oxide primer to steel surface including excavation earthwork in hard / dense soil returning filling in. disposal of surplus soil to a distance n. exc 50 mtr outside MD land etc, complete all as specified and directed |
| 51 | M& L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed. |
| 52 | EXTERNAL ELECTRIFICATION |
| 53 | Material and labour for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and inner dia 38mmincluding 90 degree bends with includingcoupler and rubber ringlaid in trenches of size 90mm suitable for cable protection complete all as specified and direct |
| 54 | Material and labour for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and inner dia 75mmincluding 90 degree bends with includingcoupler and rubber ringlaid in trenches of size 90mm suitable for cable protection complete all as specified and direct |
| 55 | M&L for Shifting of Transformer (Capacity 160 & 200 KVA) from AGE E/M Store yard to Site without any damageincluding necessary lifting & Transporting eqpts ,Making necessary HT and LT side cable connections, painting with enammeled gray paint complete all as directed by Engineer-in Charge |
| 56 | M & L for transformer plinth of size 2 m x 2m x 1.5 m to mount the 11 KV Transformer up to capacity of 200KVA, PCC platform for transformer shall be provided as per CEPZ/98/TD/6 Sheet 2/2 complete all as specified and directed |
| 57 | Supply, fixing and install7 mtr height octagonal pole top 70 mm, bottom 130 mm, 3 mm thickness with base plate 200x200x12 mm and GI 64 micron, M19x600 EN 8 grade foundation bolt and 1.5 mtr decorative armfor light fittings complete including foundation (drawing provided by OEM for foundation of pole) and all as directed and specified by Engr in Charge. (Note : Rate for RCC foundation as per drawing, Excavation, 7mtr pole, decorative arm, foundation bolts and nuts included in this item rate.) |
| 58 | Supply and fixing Solar LED Street light with inbuilt solar Charge controller, Solar PV module ,LifePO4 battery & mounting clamp as a ready to install complete ,50 wattwith out pole all as per Halonix cat Part No. HLSSLINT090170120-50W-WOP-CWL or equivalent |
| 59 | Supply, installing, testing and commissioning factory made, outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having 600 Amps capacity alluminium bus bar for phase and 600 Amps alluminium bus bar capacity for neutral , colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 3.00 mm thick CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, ,provision of connecting earth strip from 2 sides, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 40x40x6 mm, welded on all the four corners, embedded in pack 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:- |
| 60 | a) MCCB4 pole,415 Volt, 35 KA 400 Amps(In coming)-01 No.b) MCCB4 pole,415 volts25 KA 63 Amps(Outgoing)-09 Nos.c) MCB 32 Amps TPN 10 KA-01 Nod) Digital Voltmeter and ammeter with selector switch -01 Noe) One no. danger notice plate |
| 61 | Supply, installing, testing and commissioning factory made, outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having 300 Amps capacity alluminium bus bar for phase and 300 Amps alluminium bus bar capacity for neutral , colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 3.00 mm thick CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, ,provision of connecting earth strip from 2 sides, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 40x40x6 mm, welded on all the four corners, embedded in pack 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:- |
| 62 | a) MCCB4 pole,415 Volt, 35 KA 200 Amps(In coming)-01 No.b) MCCB4 pole,415 volts25 KA 100 Amps(Outgoing)-04 No.c) Digital Voltmeter and ammeter with selector switch -01 Nod) One no. danger notice plate |
| 63 | M & L for fencing and Gates for transformer of Size (6.00 mtrs x 6.00 mtrs x 2.45 mtrs) complete including excavation, steel ,chain link, PCC, Painting etc complete all as directed |
| 64 | M&L Cable route marker made out of GI angle iron of size 25x25x3mm thick 60cm long for HT CABLE\" route marking embossed on GI circular plate 150mmdia 3mm thick including grouting in PCC 1:3:6 type C1 block concrete of size 20x20x20cm including necessary earthworkcomplete all as specified and directed. |
| 65 | M&L Cable route marker made out of GI angle iron of size 25x25x3mm thick 60cm long for \" LT CABLE\" route marking embossed on GI circular plate 150mmdia 3mm thick including grouting in PCC 1:3:6 type C1 block concrete of size 20x20x20cm including necessary earthworkcomplete all as specified and directed. |
| 66 | M& L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for LT underground cables suitable for 0.4 Mpa working pressure complete all as specified and directed. |
| 67 | DG SET |
| 68 | Supply, installation, testing and commissioning Diesel Engine driven generating set of capacity not less than 200 KVA/ 160 KW, 3 phase, 4 wire, 415 V, 50 Hz,1500 RPM, AC power supply with power factor 0.8 (lagging) , coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shallhave salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB-IV +) latest regulation / norms (NOx+HC < 4.0, CO < 3.5, PM < 0.2 & smoke limit < 0.7 ) with fuel tank, battery & standard accessories,tools & spares as provided by manufacturer complete with necessary PCC foundations PCC foundation as per OEM/ manufacturer recommendation to bear the load of DG sethaving suitable size including excavation and earth work with block masonry work and plastering all as specified and as directed:-(I) ENGINE- Water cooled diesel engine at 1500 RPM, enginecapacity suitable for200 KVA output ,415 V,50 Hz, No of cylinder- 06 Nos consists of direct injection, turbo-charged, four stroke liquid cooled technology confirming to BS : 5514 and IS :10000 suitable for prime duty generating set. Alternator under NTP conditions with provision of 10 % over load for 1 hour confirming to latest CPCB norms.The Engine shall consist of the following:-(a) Dry type air cleaner |
| 69 | (b)Exhaust silencer(c) Expansion bellows(d) Lube oil cooler(e) Lube oil filter(f)Radiator, radiator fan and mounting(g) Fuel pump, with governor(h) Fly wheel with starter ring(j) Battery charging alternator with suitable capacity(k) 12 Volts electric starter motor |
| 70 | Engine Monitoring system :-The genset monitoring and safety system, having following features :-(a)Control panel consisting of built in ON/OFF/start key (b) Battery charging voltmeter.(c) Electronic hour meter. (d) Indication & Monitoring of oil pressure & safety trip in case of Low oil pressure. (e) Indication & Monitoring of coolant temperature & safety trip in case of high coolant temperature. (f)In-built engine shut down system in case of engine over speed. (g) Indication & Monitoring of fuel level and alarm. (II) BRUSH LESS ALTERNATOR:-Alternator suitable rated for 200 KVA DG at 0.8 PF, 415V, 3 phase, 4 wire, 50 cycles/sec, 1500 RPM, self excited and self regulated, with Brushless Excitation Band of voltage regulation + 1% of rated voltage, from NO load to full load, Insulation class \"H\".The alternator generally conforms to BS : 2613/ IS : 4722(III) BATTERY:-Heavy duty batteryof suitable AH and Nos connected to the system fully charged including lead and battery terminals complete of Make as provided by OEM |
| 71 | (IV) STANDARD CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable made of sheet steel duly painted with stove enamel paint consists of followings :-(a)01 No MCCB of suitable rating.(b)01 No, EMS(c)03 Nos Current Transformer(d) 02 Nos indicating lamps(e) 01 set control fuses(f)01 No KWh meter |
| 72 | (V) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL (DOUBLE CONTACTOR)The control panel will be free standing, , cubical type, outdoor type, front operated dust and vermin proof, fabricated out 3 mm thick CRCA sheetduly power coated after necessary pre-treatment process & consisting of following :-Power Circuit MainsDG Set1 No 4P contactor suitable rated1 No 4P contactor suitable rated1 No 3P MCCB suitably rated 1 No 3P MCCB suitably ratedControl & Metering Circuit1 No Microprocessor based AMF logic controller1 No KWh meter1 No Line Voltage Monitor L&T Make.1 set of control fuses1 No static battery charger circuit with ON/OFF switch.Battery charger \"ON\" indication.Reserves Polarity indication. 1 No DC battery charging ammeter. |
| 73 | (V) ONE SET OF ACCESSORIES COMPRISING OF:-(a) Fuel tank - Capacity of tank shall be to hold diesel sufficient for 08 hours running at full load,with following features:(i) Level indicator.(ii) drain plug .(iii) MS class \"C\" piping for inlet from pump to tank to engine.(iv) Fuel strainer.(v) Air vent.(d) Base plate :- Fabricated out of MS channel\"s ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer. |
| 74 | (VI) Necessary civil foundation works including excavation , PCC , and other requirements as required and as recommended by OEM. The Foundation shall be minimum of 400mm above the FFL.(Notes for Item no.23.1 to 23.70)(a)Cost of foundation for DG Set included in quoted rates, Contracator has to produce the Drg as recommended by OEM& take necessary approval from GE before construction of the foundation.(b) Factory inspection of DG Set shall be carried out by Rep of Accepting Officer, contrcator has to intimate the Dept in advance .(c) After installation of DG Set at siteit shall be tested by IEM of HQ CEPZ or Rep of Accepting Officer, contractor has to arrange all the T & P & Fuel required for testing & rates quoted including the same).(d) Completion of the work will be issued only after the successful load testing of DG set |
| 75 | Supply, installation, testing and commissioning Diesel Engine driven generating set of capacity not less than 160 KVA/ 128 KW, 3 phase, 4 wire, 415 V, 50 Hz,1500 RPM, AC power supply with power factor 0.8 (lagging) , coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shallhave salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB-IV +) latest regulation / norms (NOx+HC < 4.0, CO < 3.5, PM < 0.2 & smoke limit < 0.7 ) with fuel tank, battery & standard accessories,tools & spares as provided by manufacturer complete with necessary PCC foundations PCC foundation as per OEM/ manufacturer recommendation to bear the load of DG sethaving suitable size including excavation and earth work with block masonry work and plastering all as specified and as directed:- |
| 76 | (I) ENGINE- Water cooled diesel engine at 1500 RPM, enginecapacity suitable for 160 KVA/ 128W ,415 V,50 Hz, No of cylinder- 06 Nos consists of direct injection, turbo-charged, four stroke liquid cooled technology confirming to BS : 5514 and IS :10000 suitable for prime duty generating set. Alternator under NTP conditions with provision of 10 % over load for 1 hour confirming to latest CPCB norms.The Engine shall consist of the following:-(a) Dry type air cleaner(b)Exhaust silencer(c) Expansion bellows(d) Lube oil cooler(e) Lube oil filter(f)Radiator, radiator fan and mounting(g) Fuel pump, with governor(h) Fly wheel with starter ring(j) Battery charging alternator with suitable capacity(k) 12 Volts electric starter motorEngine Monitoring system :-The genset monitoring and safety system, having following features :-(a)Control panel consisting of built in ON/OFF/start key (b) Battery charging voltmeter.(c) Electronic hour meter. (d) Indication & Monitoring of oil pressure & safety trip in case of Low oil pressure. (e) Indication & Monitoring of coolant temperature & safety trip in case of high coolant temperature. |
| 77 | (f)In-built engine shut down system in case of engine over speed. (g) Indication & Monitoring of fuel level and alarm. (II) BRUSH LESS ALTERNATOR:-Alternator suitable rated for 160 KVA DG at 0.8 PF, 415V, 3 phase, 4 wire, 50 cycles/sec, 1500 RPM, self excited and self regulated, with Brushless Excitation Band of voltage regulation + 1% of rated voltage, from NO load to full load, Insulation class \"H\".The alternator generally conforms to BS : 2613/ IS : 4722(III) BATTERY:-Heavy duty battery of suitable AH and numbers connected to the system fully charged including lead and battery terminal\"s complete . Make: Exideor equivalent as recommended by OEM (IV) STANDARD CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable made of sheet steel duly painted with stove enamel paint consists of followings :-(a)01 No MCCB of suitable rating.(b)01 No, EMS(c)03 Nos Current Transformer(d) 02 Nos indicating lamps(e) 01 set control fuses(f)01 No KWh meter(V) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL (DOUBLE CONTACTOR)The control panel will be free standing, , cubical type, outdoor type, front operated dust and vermin proof, fabricated out 3 mm thick CRCA sheetduly power coated after necessary pre-treatment process & consisting of following :- :- |
| 78 | Power Circuit MainsDG Set1 No 4P contactor suitable rated 1 No 4P contactor suitable rated1 No 3P MCCB suitably rated 1 No 3P MCCB suitably ratedControl & Metering Circuit1 No Microprocessor based AMF logic controller1 No KWh meter1 No Line Voltage Monitor L&T Make.1 set of control fuses1 No static battery charger circuit with ON/OFF switch.Battery charger \"ON\" indication.Reserves Polarity indication. 1 No DC battery charging ammeter. |
| 79 | (V) ONE SET OF ACCESSORIES COMPRISING OF:-(a) Fuel tank - Capacity of tank shall be to hold diesel sufficient for 08 hours running at full load,with following features:(i) Level indicator.(ii) drain plug .(iii) MS class \"C\" piping for inlet from pump to tank to engine.(iv) Fuel strainer.(v) Air vent.(d) Base plate :- Fabricated out of MS channel\"s ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer. |
| 80 | (VI) Necessary civil foundation works including excavation , PCC , and other requirements as required and as recommended by OEM. The Foundation shall be minimum of 400mm above the FFL.(Notes for Item No. 23.80 to 24.30)(a)Cost of foundation for DG Set included in quoted rates, Contracator has to produce the Drg as recommended by OEM& take necessary approval from GE before construction of the foundation.(b) Factory inspection of DG Set shall be carried out by Rep of Accepting Officer, contrcator has to intimate the Dept in advance .(c) After installation of DG Set at siteit shall be tested by IEM of HQ CEPZ Pune or Rep of Accepting Officer, contractor has to arrange all the T & P & Fuel required for testing & rates quoted including the same).(d) Completion of the work will be issued only after the successful load testing of DG set |
| 81 | Sewage Disposal |
| 82 | M&L Double Wall corrugated 150mm dia class SN8pipe including necessary rings/socket/fittings, laid and jointing confirming to IS-16098 part 2 drain pipe complete all as specified and as directed. |
| 83 | M&L Double Wall corrugated 200mm dia class SN8pipe including necessary rings/socket/fittings, laid and jointing confirming to IS-16098 part 2 drain pipe complete all as specified and as directed. |
| 84 | RAIN WATER HARVESTING |
| 85 | Supplying, filling ,spreading & leveling gravels of size range 5mm to 10mm in the screen chamber over the existing layer of boulders in required thickness for all leads and lift, complete all as specified and directed. |
| 86 | M&L spreading of Charcoal 15mm to 25mm in size as in filling layers, complete all as specified and directed. |
| 87 | M&L spreading of Pebbles in size as in filling in layers,complete all as specified and directed. |
| 88 | M&L for drilling of 12\" (300mm) bore in any strata in any type of soil rock by means of rotary drilling method up to 50m deep below GL including disposal off surplus soil to a 50M complete |
| 89 | Supply lowering and fixing of plain MS black pipe 6\" (150mm) nominal bore medium grade wall thickness 4.80mm made of MS ERW sockets and socketed IS 1239 marked pipe in standard length complete with necessary fitting and joining complete |
| 90 | All as per sl item No 26.50 above but slotted pipe having (1.59mm to 3mm) x 75mm slot complete with necessary fitting and jointing |
| 91 | S&F MS well cap 6\" (150mm) bore mild steel ERW pipe having internal threads and with welded iron handle and fixed in position complete |
| 92 | Washing the bore with compressed air (pressure not less than 250 PSI & 400 cuft per minute capacity) to improve porosity and taking out all the sedimentation silt, deposited at a distance not exc 50m |
| 93 | S&F bail plug suitable for 150mm bore pipe wall thickness 4.80mm made out of MS black pipe complete |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail