| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed. |
| 2 | M&L for dismantling floor heart or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and com[plete all as specified. |
| 3 | Taking down chowkats or frame with shutter (without taking off shutters from the frames) n exc 1.5 Sqm complete all as specified and as directed. |
| 4 | Taking down chowkats or frame with shutter (without taking off shutters from the frames) exc 1.5 Sqm and n exc 4.00 sqm each of any description incl making good the disturbed surfaces complete all as spd and as directed. |
| 5 | S&F Anodised powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified and directed |
| 6 | Material and labour for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in levelling courses laid and compacted in slope in floor complete all as specified and as directed. |
| 7 | M&L for joint freenon skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. (square/rectangular) area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 8 | M&L for glazed ceramic tiles, coloured, 350x250x7mm/450x350x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointedin neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces complete all as specified and directed. |
| 9 | M&L forIndustrial Grade tiles12-15 mm thick area of each tiles not less than exc. 0.06 sqm but n. exc. 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed. |
| 10 | M&L forIndustrial Grade tiles12-15 mm thickon vertical surfaces such as dados, skirtings and risers to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces complete all as specified and directed. |
| 11 | M&L for pcc (1:2:4) type B-0 using 12.5 mm thick course aggregate as in cills , steps, parapets, coping and the like including weathering slightly rounded or chamfered angles and throating as directed complete all as specified and directed. |
| 12 | M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed |
| 13 | S&F Mortice lock,Brass 4 level vertical type, size 100 mm complete all as specified and as directed |
| 14 | S&F Aluminium (extruded action body) Door closer hydrau lically regulated,designation No. 3,universal type, suitablefor door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. |
| 15 | Taking up or down 15 mm dia steel tubing and connectionand removal from site complete all as specified and as directed |
| 16 | S & F 15 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed. |
| 17 | Taking up or down 20 mm dia steel tubing and connectionand removal from site complete all as specified and as directed |
| 18 | S&F steel water tubing medium grade galvanized with all fittings and fixed complete to20mm bore complete all as spd. |
| 19 | Dismantling of existing water tank (PVC/RCC/AC) exc 500 ltr but n exc 1000 ltr capcity and removing from site complete as directed by Engr -in-charge. |
| 20 | S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete in repair Taking up or down 15 mm dia steel tubing and connectionand removal from site complete all as specified and as directed. |
| 21 | Disconnecting existing water tanks exc 500ltrs but n exc 1000 ltrs cap setting aside (or lowering if required) for repair cleaning etc and hoisting if required reconnecting and refixing in position. (cleaning repairing etc measured separartely) Taking up or down 15 mm dia steel tubing and connectionand removal from site complete all as specified and as directed. |
| 22 | Disconnecting existing water tanks exc 250ltrs but n exc 500 ltrs cap setting aside (or lowering if required) for repair cleaning etc and hoisting if required reconnecting and refixing in position. (cleaning repairing etc measured separartely) complete all as specified and as directed. |
| 23 | M & L for Plain Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) complete all as specified and directed by EIC. |
| 24 | Taking down cement or cement lime plaster of any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc and complete all as specified and as directed. |
| 25 | M& L for 10mm thick rendering on stone masonary in CM 1:4 on wallsusing integral water proofing compound @ 3% weight of cement , finished even and smooth without using extra cement andall as specified.(NOTE;- Water profing compound shall be measured and paid seperately) |
| 26 | Supply only integral water proofing compound ISI Marked |
| 27 | M&L Preparation of newlyplastered surfaces of walls and applying two coats of cement base paint over a coat of primer on walls complete all as specified and directed. |
| 28 | M&L for rendering 15mm thick in CM 1:6 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 29 | M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil emulsion distemper,over two coat of including 1.5 mm thick wall care putty complete all as specified and as directed. |
| 30 | M&L Rendering 5mm thick plastering in cement mortar 1:3 as in ceiling finished even and smooth without using extra cement to match with existing surface complete all as specified and directed. |
| 31 | M& L preparing plastered new surfaces of ceiling and applying three coats of white wash on ceiling surface complete all as specified and as directed. |
| 32 | Complete removal of existing treatment and M& L Preparation ofnewly plastered surfaces of walls and applying two coats of cement base paint on walls complete all as specified and directed. |
| 33 | M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed. |
| 34 | M&L for preparation of old surfaces (plastered or unplastered) of walls including removing/scrapping down existing surface where ever necessary and applying two coat of oil emulsion distemper over two coat of wall care putty complete all as specified and as directed. |
| 35 | Dismantling plain or asbestas cement corrugated semi corrugated sheets in roof coveringany guage thickness complete all as specified and directed. |
| 36 | Dismantling timber scantlings 40 sq. cm and over in section, in any positionandcomplete all as specified and directed by Engr-in-Charge. |
| 37 | M&L for steel work in tubular posts , trusses,purlin rafters including special shaped washer etcor induction butt welded tubes complete all as specified and as directed. |
| 38 | M&L for preparation of new steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthatic enamel paint over one coat of red oxide primercomplete all as specified and as directed by Engr-in-Charge. |
| 39 | S&F pre-painted galvalumne aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensilestrenght of 550 Mpa as in roof covering /cladding to wall fixed with self screws complete all as specified and as directed. |
| 40 | Supply and fixing Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges, flashing, eaves board valley gutter of any shape etc, cut to designed shape (Jhhallar) as directed at site fixed all as per manufactures\"s instructions and fixed with self thread making steel screws of length not less than 50mm as directed by Engr-in-Charge at site with suitable arangement as required complete all as specified & directed. |
| 41 | Dismantlingwall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and complete all as specified and directed by Engr-in-Charge |
| 42 | S&F for power coated Anodised aluminium snap grid frame work for false ceiling size of grid 605x605 mm including hanger 6mm dia GI (up to 1200mm length) adjusting level fixed to roof slab by means of cuting cleats made out of GI flat 40x3mm size 600mm long and expansion hold fasteners 12.5 mm dia 40mm longcomplete all as specified. |
| 43 | S&F 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws & fixed in ceiling flat or slopin and complete all as specified and directed by Engr-in-Charge |
| 44 | S&F Factory made solid panel PVCdoor shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C\" channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. |
| 45 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing |
| 46 | Supply and fixing stainless steel butt hinges medium weight , clod rolled, 100mm, ISI marked, complete all as specified & directed. |
| 47 | Supply and fixing aluminium fabricated type extruded handles of size 150 mm complete all as specified & directed. |
| 48 | Material & Labour stainless steel barrel tower bolts aluminium anodised extruded section of size 150 mm complete all as specified & directed. |
| 49 | Material & Labour for 75mm thick plain cement concrete C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection/path finished fair and even without using extra cement complete all as spd & directed. |
| 50 | S&F in repairs, EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified. |
| 51 | S&F in repairs vitreous- China wash down water closet Squatting pan ( Orissa Pattern) size 580 x 440 mm includingflush pipe , PVC P-trap and PCC for fixing complete all as specified and as directed. |
| 52 | S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified. |
| 53 | S&F in repairs PVC valveless, syphonicaction type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets. |
| 54 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm. |
| 55 | S&F in repair CP soap dish, fixed to plugs with chromium plated screws and all as specified. |
| 56 | S&F in repair CP tubular towel rail, 20 mm dia, D type, 60 cm long between flanges and all as specified |
| 57 | S&F in repair CP grating 100 mm dia all as specified and as directed. |
| 58 | S&F in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long |
| 59 | S & F in repair 600 x 450 mm beveled edge mirror of selected quality glass of 5.5 mm thick mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and as directed |
| 60 | S&F in repair stop/gate valves/angle valves cast copper alloy CP fancy type screwed down high pressure with crutch or butterfly handle for 15mm bore. |
| 61 | S&F in repair 15mm bib taps cast copper alloy CP Fancy type with crutch or butterfly handle screwed down for iron pipe or for brass ferrule. |
| 62 | M&L for powder coated anodised aluminium frame for door window & ventilator with one or more rebates including joining cleat for fixing etc comlete all as specified. |
| 63 | S&F sheet glass 5.5 mm thick, tinted quality and glazing fixed with rubber beading in aluminium frame exc 0.50 sqm in each pane works complete all as specified and directed by Engr-in-Charge. |
| 64 | S& Ffor 4 to 5mm thickAluminium composite panelfixed with rubber beading in aluminium frame works complete all as specified and directed by Engr-in-Charge. |
| 65 | Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed. |
| 66 | M&L for squared rubble walling, Jodhpur type, brought up to courses, well bonded, bedded and solidly hearted, built in CM 1:4 |
| 67 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 100 mm diaetc cpmplete all as specified and as directed |
| 68 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including clamps as required complete all as specified. |
| 69 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor as required complete all as specified. |
| 70 | S&F 110mm dia PVC (SWR) junction single, (single T), equal or un equal with oval accesse door including jointing with solvant cement as required complete all as specified. |
| 71 | S&F 110mm dia PVC (SWR) bends with oval accesse door with rubber ring joints fixed as required complete all as specified. |
| 72 | S&F 110mm dia PVC (SWR) vent cowl, single, equal or un equal of any length including jointing with solvant cement as required complete all as specified. |
| 73 | S&F PVC (SWR) floor trap with garting of outlet dia 75/110mm incl jointing with solvent cement |
| 74 | M&L for Pre-cast cement concretefactory made kerb stonewith 1:3:6 type C1 (20mm graded Stone aggragate) solid blocks, exc. 10 cm in width and setting in mortar,CM 1:6 complete all as specified and directed. |
| 75 | Excavation in post holes (or similar holes) each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface (Soft/loose soil)complete all as specified and directed by Engr-in-Charge. |
| 76 | M&L for cement concrete type C-2, 1:3:6 using 40mm graded aggregate as in foundation, filling and mass concrete complete all as specified and as directed. |
| 77 | Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 1568-2006 OF 80MM thickness, M-40 Grade with grey cement and pigment complete all as specified and directed. |
| 78 | M&L for 25mm thick sand filling under floor including consolidation complete all as specified and directed. |
| 79 | M&L for preparation of old painted wooden surface of any description not otherwise provided over 10 cm width or girth and applying one coats of synthetic enamel paintand complete all as specified and as directed. |
| 80 | M&L for preparation of old painted steel surface of any description not otherwise provided over 10 cm width or girth and applying one coats of synthetic enamel paintand complete all as specified and as directed. |
| 81 | Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,. |
| 82 | M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, FRLSH ,PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : -Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators,conduit heavy duty, as required at site. |
| 83 | One light / fan point controlled by one switch one way. |
| 84 | One 3 pin 5 Amp switch & socket outlet on same board with other switches. |
| 85 | One 3 pin 5 Amp switch & socket outlet on Independant board. |
| 86 | All same as per item ser No 82.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, FRLSH, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board. |
| 87 | All same as per item ser No 82.00 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, FRLSH,single core, PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers. |
| 88 | S&F switch modular single pole one way 6 Amps 230 volt 1 module. |
| 89 | S&F switch modular single pole one way 16 Amps 230 volt 1 module. |
| 90 | S&F Socket modular 6 Amp 2/3 pin combined two module. |
| 91 | S&F Socket modular 6&16 Amp 2/3 pin combined two module. |
| 92 | S&F Stepped type electronic fan regulator, socket size, flush type 230V AC. |
| 93 | S&F Ceiling rose surface bakelite 65x50mm three terminal. |
| 94 | Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed. |
| 95 | M&L for celing light fitting of Skylux LED eeficient 2*2 (600x600MM) luminaire and glare free soft illumination of capacity 36 watt LED white colour complete suitable for roof ceiling including connecting upto with driver 3 core flrxible conductorcupper of suitable size complete all as specified and directed by Engr-in-charge. |
| 96 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified. |
| 97 | Supply and fixing on wall,installation ,testing & commissioning in replacementof hi wall split units BEE 5 star rated indoor /outdoor ( evaporator and condensor shall be of copper) ,inverter type copper tubing of required size for proper installation and outdoor unit including wall / floor mounted stand complete with cordless remote control unit with capacity 2.0 TR 230 volt AC supply complete all as specified and as directed by engr in charge. |
| 98 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, including steel ironangle iron channel of height 5 ft heightand size 35x35x5 mm with impact and corrosion resistant,including complete welding work saddle work etc complete with driver and lamp complete all as specifiedby Engr-in-Charge. |
| 99 | M&L for Sub main wiring as per IS, single core FRLS PVC insulatedflexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color. |
| 100 | Supply and fix sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion completeincluding taking out old all as directed. |
| 101 | Supply and fix TPN distribution board double door made out of CRCA mild steel sheet surface with insulate material like polyester or with powder coating surface mounting TPN DB 12 WAY 415 V with dust and vermin proof suitable for incorporation of MCBs and isolatorf etc complete all as specified and directed. |
| 102 | S&F MCCB 4 pole 100A 415 V having breaking capacity 16KA all as specified and directed by Eng-in- charge. |
| 103 | Supply and fixing triple pole MCB 100 Amps, 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 104 | Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion completeincluding taking out old all as directed. |
| 105 | M&L for MCB SPN/DP 40Ato 63Amps 240 volts, 30 mA capacity and 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.Make- Havells cat part no-DHCEACSN2030040 |
| 106 | Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 107 | Excavation in trenches in soft/loose soil n exc 1.5mwide and n.exc 1.5m in depth and getting out complete all as specified and directed. |
| 108 | Removing excavated surplus soilto a distance n exc 50 m anddepositing where directed at a level n exc 1.5 mtr above starting point all as specified and directed |
| 109 | Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 110 | Material and labour for sand cushining to underground cable, provided with a layer 8 cm before and 15cm after laying and stretching jointing and testing the cable all as specified and directed |
| 111 | M&L for stone slab 40 to 50 mm thick rough dessed jodhpur stone slab cover in trenches for protection of cable 25 to 30cm wide and not less than 50 cmm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning all as specified and direceted by engineer-in- charge. |
| 112 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core |
| 113 | Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate)complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion.Note:- (i)PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |