| Sl. No. | Item Description |
| 1 | Building Work:Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.a) Depth of excavation not exceeding 1500 mm. |
| 3 | (c) Anti-termite treatment to the soil under floor with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight including drilling vertically 12mm. dia holes at the junction of floor and wall at 300mm. interval to reach the soil below using hand operated pressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealed after operation to match with the existing floor. The entire work is to be carried out as per specification laid down in para 4.3.1.4 of code I.S.-6313 (Part-III)- 1981. |
| 4 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete (payment to be made on the basis of measurement of finished quantity of work).(a) With earth obtained from excavation of foundation. |
| 5 | A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand |
| 6 | Supplying and laying Polythene Sheet (150gm / sq.m.) overdamp proof course or below flooring or roof terracing or infoundation or in foundation trenches. |
| 7 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips(20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(b) River bazree |
| 8 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer\"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)(f) 25 mm to 30 mm shuttering without staging in foundation. |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 11 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 12 | Labour for laying single brick flat soling including ramming and dressing bed to proper level and filling joints with powdered earth. |
| 13 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes(ii ) River Bazree |
| 14 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.a)For works in foundation, basement and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINL |
| 15 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 16 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 17 | Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor |
| 18 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).(i) With 1:6 cement mortar(b) 20 mm thick plaster |
| 19 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).(i) With 1:6 cement mortar (c) 15 mm thick plaster |
| 20 | Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 21 | Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc.NOTE:Cement 0.152 cu.m per100 sq.m |
| 22 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(d) Sal : Local |
| 23 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor(a) 35 mm thick shutters (single leaf) |
| 24 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor(a) 35 mm thick shutters(c) Double leaf shutters [Note: Mode of measurement-Measurement shall be made on the basis of area of shutter] |
| 25 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. |
| 26 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.In ground floor.(i) 32 mm thick |
| 27 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor)In ground floor. Flash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grills.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] |
| 28 | v) Two point nose aluminum handle including fitting and fixing. |
| 29 | vii) Aluminium peg stay 300 mm. long including fitting and fixing. |
| 30 | Supplying best Indian figured glass viz. hammered, fluted,ribbed,pinhead etc., type including cutting to required sizes, setting on putty bases and fitted and fixed with nails and putty complete. (in all floors for internal wall & upto 6 m height for external wall) |
| 31 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 32 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 33 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) -(ii) Two coats (white in shade) |
| 34 | (a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 35 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.In Ground Floor:(b) Two Coats[This item to be done under specific instruction of the Superintending Engineer]N.B.:-Extra for each additional floor in external walls refer item 1 of subhead C |
| 36 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)b) Premium 100% Acrylic Emulsion |
| 37 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer |
| 38 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats)i) Standard Quality |
| 39 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(b) 40mm X 6mm, 200mm Length |
| 40 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(iii) 75mm. X 40mm. X 1.12mm. |
| 41 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting(a) 200mm long |
| 42 | Anodised aluminium barrel/tower /socket bolt(fullcovered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(iv) 150mm long x 10mm dia. bolt. |
| 43 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(v) 125 mm grip x 12 mm dia rod. |
| 44 | (i) Door stopper.(Brass) |
| 45 | i) Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.(b) Medium (I.S.I. size 2) |
| 46 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor)(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr(MODE OF MEASUREMENT):The weight of grill per sq.m. will be determined by taking the physical weight of fabricated grill and dividing the same by covered area of the same.N.B. No shop priming will be allowed to facilitate inspection of workmanship. Weight of grill is to be taken after final grinding and finishing the weld. |
| 47 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor)In ground floor(Payment will be made on the area of the gate covered by twoguard rails and two extreme channels) |
| 48 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr\"s hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be supplied by the contractor).b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength >1500 N |
| 49 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mmthickness in floor, lobby, stair, landing & treads etc. over 20mm (av.) thck base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/Sq.m before placing marble & jointedwith white cement slurry @ 2.0 kg/Sq.m with necessarypigments including grinding and Granite polishing as perdirection of Engineering -in -Charge in Ground Floor. {Whitecement and Pigment to be supplied by the Agency](b) With Chawk Dungri(ii) Area of each tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m. |
| 50 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative |
| 51 | Supplying,fitting & fixing granite slab 15mm to 18mm thick infloor, lobby, stair, landing and treads etc. over 20mm (avg)thick base of cement morter (1:2) laid with white cement slurry@ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface completeIn ground floor(a) Area of each Granite slab upto 0.60 Square meter |
| 52 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] |
| 53 | Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling]Red Variety(ii) 30 mm. thick |
| 54 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete)In ground floor |
| 55 | P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide. PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineerin-Charge .In ground floor |
| 56 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete.Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereofi) For roof truss worksa) Span up to 12 Mtr |
| 57 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre (followed by colourcoated on both side) steel sheet work having minimum yieldstrength of 550 Mpa of trapizoidal profile of approved make(excluding the supporting frame work) fitted and fixed with55 mm & 25 mm self tapping screw, EPDM Washer 16 mmdia & 3 mm th. washer etc. complete with 150 mm end lapand one corrugation minimum side lap. (Payment to be madeon area of finished work).(i) In Roof:- |
| 58 | Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping)(A) 300 mm lapping each way(b) With 0.63 mm sheet |
| 59 | Galvanised plain sheet works (excluding supportingframework) fitted and fixed with 6 mm. dia J or L hook-boltsand nuts, sheet-bolts, limpet and bitumen washers and puttywith 150 mm. end lap & 50 mm minimum side lap complete.(a) In roof: with 0.63 mm. sheets. |
| 60 | Wooden eaves board as per design, fitted and fixed complete:In ground floor(i) Plain eaves board (Local Sal)(a) 19mm thick |
| 61 | Direction and Place Identification Signs with size more than 0.9 sqm size Board.Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision) |
| 62 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) |
| 63 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge.The rate includes the cost of labour, adhesive and all incidental charges thereof.In ground floorGlossy/Matt/Suede excluding surface texture or metallic lustre.(i) Thickness of laminate 1.5mm |
| 64 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, alamoid/ Bitumen/ M-Seal etc) completeA) UPVC Pipes:(ii) 110 mm. Dia |
| 65 | B) UPVC Fittings:\"b) Plain Y\"(ii) 110 mm. Dia. |
| 66 | c) Bend 87.5 degree\"(ii) 110 mm. Dia. |
| 67 | d) Shoe(ii) 110 mm. Dia. |
| 68 | SANITARY & PLUMBING :Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(a) For Exposed Work(i) CPVC Pipes Class-I,SDR-1125 mm (Dia) |
| 69 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(a) For Exposed Work(i) CPVC Pipes Class-I,SDR-1140 mm (Dia) |
| 70 | (b) For Concealed Work(i) CPVC Pipes Class-I,SDR-1115 mm (Dia) |
| 71 | (b) For Concealed Work(i) CPVC Pipes Class-I,SDR-1125 mm (Dia) |
| 72 | Supply of Chlorinated Polyvinyl Chloride (CPVC ) pipes & fittings conforming to IS-15778: 2007(P) Ball Valve25 mm (Dia) |
| 73 | Supply of Chlorinated Polyvinyl Chloride (CPVC ) pipes & fittings conforming to IS-15778: 2007(P) Ball Valve40 mm (Dia) |
| 74 | Supply of Chlorinated Polyvinyl Chloride (CPVC ) pipes & fittings conforming to IS-15778: 2007(P) Ball Valve50 mm (Dia) |
| 75 | Supplying, fitting and fixing bib cock or stop cock.© (ii) Chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand). |
| 76 | (d) (ii) Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand). |
| 77 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(iii) 630 mm X 450 mm size |
| 78 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) |
| 79 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing).(ii) 530 mm X 410 mm |
| 80 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).(i) 450 mm X 350 mm |
| 81 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 82 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(ii) 470 mm X 280 mm X 340 mm |
| 83 | Supplying, fitting and fixing urinal flush pipe fittings of approved brand.(b) C.P. urinal flush pipe fittings range of two |
| 84 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 85 | Supplying, fitting and fixing E.W.c. In white glazed vitreous chinaware of approved make complete in position with necessary bolts and nuts etc.(i)with \"P\" trap. |
| 86 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(iii) 900 mm long |
| 87 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length(b) 110 mm |
| 88 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittingxxii) 125/110 S Trap with W.C. Ring75 mm |
| 89 | Supplying,fitting and fixing cast iron \"P\" or \"S\" trap conformimg to I.S. 3989/ 2009 and 1729/ 2002 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). (A) \"P\" Trap(iii) 100 mm |
| 90 | Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will be paid seperately).(i) 100 mm dia. |
| 91 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 1000 litre capacity . |
| 92 | Supplying, fitting and fixing shower of approved brand and make.(i) (2) Chromium plated overhead Rain shower (Round), size-200mm dia. with revolving joint (Model Code No. F7010601 of CERA or equivalent) |
| 93 | Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 94 | Supplying, fitting and fixing towel rail with two brackets(b) Aluminium(iii) 25 mm dia. and 750 mm long |
| 95 | Supplying, fitting and fixing porcelain soap tray of approved make.(i) Recessed soap tray of size 150 mm X 150 mm |
| 96 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction,neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.(i) With Pakur Variety (SAIL/TATA/RINL). |
| 97 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neatcement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing poils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials.(iii) For 30 usersB) With Pakur Variety (SAIL/TATA/RINL) |
| 98 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of abour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside diaFor (SAIL/TATA/RINL) |
| 99 | Boundary Wall:Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1.500 mm. |
| 100 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)a) With earth obtained from excavation of foundation |
| 101 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 102 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes (b) River bazree |
| 103 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(ii ) River Bazree |
| 104 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor)(a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. |
| 105 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) For works in foundation, basement and upto roof of ground floor/upto 4m.i) Tor steel/Mild steelI. SAIL/ TATA/RINL |
| 106 | Brick work with 1st class bricks in cement mortar(1:6)b) In superstructure, ground floor |
| 107 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 108 | Plaster (to wall,floor,ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (Ground floors). (i)With 1:6 cement mortar(c)15 mm thick plaster |
| 109 | Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to received decorative textured (Mat finished) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of EIC.In Ground Floor(b)Two Coats |
| 110 | Protective and decorative textured exterior high class matt finish paint of approved quality composed of special tharmoplastic reasin containing fine crystalline additives derive from granite as approved quality as manufacturers specification and as per direction E.I.C. to be applied over acrylic primer as reqquired.The Rates includes the cost of materials,labours,scafolding and all other incidental charges but excluding the cost of primer. In Ground FloorTwo coats |
| 111 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 112 | Priming one coat on steel or other metal surface with synthetic enamel/oil bound primer of approved quality including smootheining surfaces by sand papering etc. |
| 113 | Painting with best quality synthetic enamel paint of approved make and brand i/c.smoothening surface by sand papering etc. i/c.using of approved putty etc.on the surfaces in necessary.on steel or metal surface2-coats (with any shade except white) |
| 114 | Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron |
| 115 | Electrical :Supplying and fixing 32A 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. |
| 116 | Supplying and fixing 32A 415V on load Change over switch with sheet steel enclosure on flat/angle iron frame on wall with nut bolts etc incl. S&F 3 nos DIN type HRC fuse as per rating |
| 117 | Supplying and fixing double door 4 WAY Vertical TPN MCBDistribution board for MCCB incomer with IP-42/43protection, with 1 No. 160 A FP MCCB as incomer and 3 NOS 63A TP MCB, 1 NOS 32 A TP MCB as outgoing complete on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment |
| 118 | Supplying and fixing double door 8 way TPN MCB Distribution board with IP-42/43 protectionwith 1 No. 63 A FP MCB as incomer and 24 nos. 6-32 A SP MCB as outgoing complete , concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with following MCBs & MCB Isolator . |
| 119 | S & F 2+12 way double door IP-43 SPN MCB distribution board with 1 No. 40 A DP MCB as incomer and 12 no 6-32 A SP MCB as outgoing complete with Din Rail, Earth, Neutral & Phase Bars etc. to be partially recessed in wall with earthing attachment. |
| 120 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\"PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythenpipe complete with all accessories embedded in wall tolight/fan/call bell points with Modular type switch (Brandapproved by EIC) fixed on Modular GI switch board with topcover plate flushed in wall incl. mending good damages tooriginal finish a) Avg run 9 mtr. |
| 121 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\"PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythenpipe complete with all accessories embedded in wall to 240 V6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular typeplug socket & Modular type switch (Brand approved by EIC)incl. S&F earth continuity wire, fixed on 4 Module GI switchboard with 3/4 Module top cover plate flushed in wall incl.mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board. |
| 122 | Supply & Fixing 240 V, 6 A, 3 pin Modular type plugsocket (Brand approved by EIC) with 6A Modular typeswitch, without plug top on 4 Module GI/PVC Modular typeswitch board with 3 Module top cover plate flushed inwall incl. S&F switch board and cover plate and makingnecy. connections with PVC Cu wire and earth continuitywire etc. |
| 123 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plugsocket (Brand approved by EIC) with 16A Modular typeswitch, without plug top on 4 Module GI /PVC Modular typeswitch board with top cover plate flushed in wall incl.S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wireetc. |
| 124 | Supply of 250 V 300 mm. sweep,1400 rpm industrial type heavy duty (ISI)high speed exhaust fan. Make-approved by E-I-C. |
| 125 | Fixing only 300 mm dia exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection. |
| 126 | Fixing only louver shutter/cowl on wall with necy. bolts & nuts(6 mm dia x 62 mm long) |
| 127 | S & F 250 V 1200 mm sweep BLDC ceiling fan with 50% energy consumption complete with blades, canopy, down rod etc. having fixed with 2 nos ball bearing fixing the same, painting of down rod, connection by supplying 3×1.5 sq. mm stranded copper wire. Make-approved by E-I-C. |
| 128 | Supply and fixing 3/4\"MS down rod For fixing the Ceiling Fan with all accessories. |
| 129 | Supplying & Fixing iron beam fan clamp of two piece type, as perapproved specification, fabricated from 40 mm x 9 mm MS sheetflat suitable for beam having flange upto 150 mm wide – (As perDrawing no. 476 of PWD Specification Book – May 1991) |
| 130 | Supply & Fixing 240V, Modular Socket (2 Module) type fanregulator (Step type) (Brand approved by EIC) on existingModular GI switch board with top cover plate incl. makingnecy. connections etc. |
| 131 | Supply of 240V LED tube light box type batten with tube . |
| 132 | Supply of recess mounted 18 watt LED down light which range is a breakthrough technology and reliable heat management to deliver a long lasting efficient solution . |
| 133 | Supply of angular batten holder with LED lamp. |
| 134 | Fixing only bulk head /ceiling fitting on wall /ceiling by screws etc. |
| 135 | Supplying and fixing 19 mm dia and 3 mm thick polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)Make-approved by E-I-C. |
| 136 | Supplying and Drawing 1.1 KV single core stranded \"FR\"PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe by the GI fish wire and making necy. connection as required. a) 4×10 sq.mm. + 2×6 sq.mm. |
| 137 | b) 2×10 sq.mm. + 1×6 sq.mm. |
| 138 | d)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 139 | e)3 x 22/0.3 (3x1.5 sqmm) |
| 140 | i) Earthing with 50 mm dia GI pipe (ISI-M) 3.64 mm thick × 3.04 mtr long and 1 × 4 SWG (Hot dip) wire 4 mtr long) 13 mm dia × 80 mm long GI bolts double washers incl. S & F 15 mm dia GI pipe protection (1 mtr long) to be filled with bitumen party under the ground level and partly above ground level driver to an average depth of 3.65 metre below the ground level & restoring the surface duly rammed. |
| 141 | S & F earth bus bar of GI (Hot Dip) MS flat of 50 mm × 6 mm on wall is having clearance of 8 mm from wall including providing drilled holes on the bus bar complete with GI bolts, nuts, washers spacing insulators tc. As required. |
| 142 | Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CIhinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe including Extra for treatment of soil by using salt & charcoal or coke for plate electrode |
| 143 | Compound lighting: Supply & Erection of G.I Octagonal designed decorative 7 mtr long conical hot dip galvanized mild steel step pole (inbuilt loop box) with bottom dia 130 mm, top dia 70 mm, thickness 3 mm, base plate 220x220x12 (LxBxT) mm, J-bolt(GI) size 4x20 dia (no xdia) mm, both length 600 mm,projected bolt length. 48.30x3.25 mm thick base plate of 220 mm, with 4 nos holes on 220X12 mm PCD suitable for M16X600mmX4 Nos bolts along with civil foundation work.Make- Make-approved by E-I-C. |
| 144 | Supplying and fixing of 240 V 6 A SPMCB of breaking capacity 10 KA & C characteristics on din rail of existing insulated loop box of octagonal pole and necessary connection including supplying and fixing bakelite / perspex top cover of size 200 mm X 150 mm X 65 mm as per GS |
| 145 | Supplying and fixing of 1m decorative single arm bracket |
| 146 | Supply of 1.1 KV grade PVC /A aluminium conductor2 core X 10 sq.mm Make-approved by E-I-C. |
| 147 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 148 | S & F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture -proof entry of XLPE/PVC armoured cables as bellow.i)2 core X 10 sq.mm. |
| 149 | Finishing the end of following XLPE/PVC armoured cable by crimping method incl.S & F solderless socket (Dowels make,) tapes,anticorrosive paste & joining materials.i) 2 core X 10 sq.mm. |
| 150 | Supplying and fixing 4 WAY MCB SS enclosure with IP-20/30 protection, powder coated including 2 NOS 6-32A two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment |
| 151 | Supply of 72 W LED Street light luminaire with high power LED. Make-approved by E-I-C. |
| 152 | Supplying and fixing of 3 X 1.5 sq.mm PVC insulated multi-stranded copper FR wire from loop box to fittings in 15 mm dia polythene pipe and connection etc. as required. |
| 153 | Drilling borehole by Rig machine with Odex-115 (Simultaneous driving of casing pipe) method of drilling through any kind of soil, boulder, rock etc. upto the required depth. This item includes the cost of hiring of Rig machine, Compressor, Supporting vehicle and other machinery & equipments with operators, drivers, laborers etc. proportionate cost of drilling tools and accessories such asHammer, Pilot bit, Reamer bit, Guide device, Guide sleeve etc. Cost of consumable materials like fuel & lubricants, electrode for welding, any other related equipment, materials and service etc. G.L. To 60 Mtr. |
| 154 | b) 60 Mtr. To 100 Mtrs. |
| 155 | Lowering and placing of filter assembly of required length andExtraction and partening off the casing pipe of required length |
| 156 | Mobilisation and transportion of the Rig machine and itsaccessories and others materials, etc. to the site. |
| 157 | Development of the tubewell by Air Compressor and BHT/ othersuitable pump and Yield Testing by BHT/ other suitable pumpingmachinery upto the satisfaction of EIC. It includes arrangement ofall machinery, supply of fuel & lubricants, laborers, any others etc. |
| 158 | Supply and delivery of 128 mm ID/139 mm OD MSERW fin cut pipe |
| 159 | Supply and delivery of 80 mm dia x 3 mtr. Long HDPE Jacketed Strainer |
| 160 | Supply and delivery of Bit tube (0.67mtr. Long) for Odex-115 |
| 161 | Supply and delivery of Casing Shoe (for Odex-115) |
| 162 | Supply and delivery of Packer Assembly (for Odex-115) |
| 163 | Supply and Installation of 2 HP Submersible pump motor set suitable for 125 mm dia deep tube well capable for discharging 35 LPM(max) of Clear water at a total head of 58 mtr(min) having a discharging outlet of 32 mm dia with 2.5 sqmm (Finolex) 3 core PVC flat copper cable of 50 mtr including LT make DOL starter. Make-approved by E-I-C. |
| 164 | Labour charges for lowering the submersible pump set, column pipes with necessary accessories including fitting & fixing the same in the tubewell including proper electrical connection with generator all complete as per direction of Engineer-in-charge and also withdrawal of the same after completion of the test. |
| 165 | supply of PVC insulated and PVC sheathed cable with Electrolytic Grade Annealed Copper conductor having 3 core 4 sqmm flate for Submersible pump motors voltage up to and including 1100V as per IS: 694:1990. |
| 166 | Supply, fitting, fixing 50 mm dia G.I. Pipe (ISI-M) column pipe for submersible pump lowering having 3-mtr average length including special threading in Leathe and S & F one Tata GI socket. |
| 167 | Supply and fixing 4\" dia Pressure Gauge including nipple, valve etc with other jointing materials. |
| 168 | Making of brick piller of suitable size with neat cement plastering for supporting lead/plumbing line as per instruction of EIC. |
| 169 | S & F of 50 mm dia Non-return valve (horizontal) with jointing materials (ISI approved Zoloto make). |
| 170 | S & F of G.M. Peets valve including all necessary jointing materials (ISI approved) for the following size:50 mm dia. |
| 171 | S&F 50 mm dia check valve bwith flanged as required |
| 172 | S & F suitable size of M.S. Flat clamp for holding the column pipe, pump motor in the tube well with necessary nuts, bolts, washer as per direction of EIC. |
| 173 | Supplying, fitting and fixing G.I. cap at top suitable for tube well. |
| 174 | S & F 25 mm dia G.I. Pipe (ISl-M) for protection of cable. |
| 175 | Supply and delivery of direct on line ( DOL) strater panel board conforming to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (+10%) AC, single phase, 50HZ(+5yo) comprising of ammeter, voltmeter, thermal overload relay,2 pole magnetic contactor, under voltage protection, indicating lamp, capacitors, on/off push buttons including 5 way connector, wiring with l/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities:-3 H.P. (Relay Range 13-22 Amp.) |
| 176 | Supply, fabrication & installation of header assembly made of 150 mm dia 1.2 meter long black MS pipe having both sides sealed by welding provision for with MS sheet for 1 No. 50 mm dia inlet & 4 nos 50 mm dia outlet to be fixed on 50 & 40 mm short pieces welded with 150 mm header including 4 nos gun metal wheel wash out line with provision for pressure gauge and 1/2\"\" Fullway valve,nipple and presure gauge to be fixed on Header with all supporting arrangement & painting etc as per direction of EIC. |
| 177 | Supply & laying 50 mm dia GI pipe (Class-B) medium mainly U/G trench with all jointing materials as per direction of EIC. |
| 178 | S & F of G.I. Accessories (R-brand) ISI approved with all jointing materials:a) 50 mm dia Bend |
| 179 | b) 50 mm dia Elbow. |
| 180 | c) 50 mm dia Nipple. |
| 181 | d) 50 mm dia Union. |
| 182 | e) 50 mm dia Socket. |
| 183 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail