| Sl. No. | Item Description |
| 1 | CIVIL |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as wellas 10 Sq.m on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sq.m on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kind of soil. |
| 5 | Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered): Depth exceeding 1.5 m but not exceeding 3 m |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete |
| 8 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 9 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 10 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil. |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 12 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:5:10 (1 cement : 5 coarse sand (zone-III) : 10 graded stone aggregate 40 mm nominal size). |
| 13 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). |
| 14 | Extra for laying concrete in or under water and/or liquid mud including cost of pumping or bailing out water and removing slush etc. completenThe quantity will be calculated by multiplying the depth measured from the sub-soil water level up to centre of gravity of concrete under sub-soil water level with quantity of concrete in cum executed under sub-soil water. The depth of centre of gravity shall be reckoned correct to 0.1m. 0.05m or more shall be taken as 0.1m and less than 0.05m ignored |
| 15 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Stairs, (excluding landings) except spiral-staircases |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Weather shade, Chajjas, corbels etc., including edges |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 26 | Providing fusion bonded Epoxy coating not less than 175 micron thickness and upto 300 micron to reinforcement barsof any diameter as per IS-13620-1993/ ASTM-775 M including repairs to cut ends,welded spouts and handling damages with reccomendedliquid epoxy compatible with the coating and testing of coating at plant etc complete as directed by engineer ion charge. |
| 27 | Providing fusion bonded epoxy coating by mechanized & qualified process including blast cleaning, heating using Induction heater, electrostatically spraying the epoxy powder, complete fusion to give coating thickness up to 300 microns, gradual cooling without affecting the properties of steel, testing as per IS13620, flexibility/bend & holiday test, other applicable test for IS13620 Standard. |
| 28 | Extra for laying reinforced cement concrete in or under water and/ or liquid mud, including cost of pumping or bailing out water and removing slush etc., complete. The quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m or more shall be taken as 0.1 m and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under sub - soil water conditions. |
| 29 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum. |
| 30 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum. |
| 31 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level.. Concrete of M35 grade with minimum cement content of 370 kg /Cu.m |
| 32 | Providing and fixing of expansion joint system related with floor location as per drawings and directionof Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / selfcentering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that itprovides floor to floor /floor to wall expansion control system for various vertical localtion in loadapplication areas that accommodates multi directional seismic movement without stress to it\"scomponents. System shall consist of metal profiles with a universal aluminum base member designed toaccommodate various project conditions and finish floor treatments. The cover plate shall be designed ofwidth and thickness required to satisfy projects movement and loading requirements and secured tobase members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates /moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock andslide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure inall directions including vertical displacement. Provision of Moisture Barrier Membrane in the JointSystem to have watertight joint is mandatory requirement all as per the manufactures design and asapproved by Engineer -in-Charge. (Material shall confirm to ASTM 6063).Floor Joint of 100 mm gap |
| 33 | Providing and fixing of expansion joint system related with wall joint (internal/external) location as perdrawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members,self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall besuch that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to cornerapplication, both new and existing construction in office Buildings & complexes with no slipping downtendency amongst the components of the Joint System. The Joint System shall utilize light weightaluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking themulticellular to facilitate movement. (Material shall confirm to ASTM 6063)Wall Joint of 100 mm gap |
| 34 | Providing and fixing of expansion joint system of approved make and manufactures for various rooflocations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extrudedaluminum base members with, self aligning and self centering arragement support plates asper ASTMB221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint coverexpansion control system that is capable of accommodating multidirectional seismic movement withoutstress to its components. System shall consist of metal profile that incorporates a universal aluminumbase member designed to accommodate various project conditions and roof treatments. The cover plateshall be designed of width and thickness required to satisfy movement and loading requirements andsecured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement thatfreely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere endsthat lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movementand flexure in all directions including vertical displacement. The Joint System shall resists damage ordeterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foottraffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to havewater tight joint is mandatory requirement. (Material shall confirm to ASTM 6063Roof Joint of 100 mm gap |
| 35 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 36 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 37 | Providing and applying Antitermite treatement by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatement and creating a chemical barrier as per IS 6313 (Part ll) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building,etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge.(Plinth area only to be measured for the payment ) (The above work shall be carriedout by an agency having sufficient experience and should ensure a warranty for a period of 10 years. Only skilled and experienced persons shall be employed for this purpose.) |
| 38 | Providing,diluting and injecting chemical emulsion to 12mm dia holes in Masonry/earth fiiling and plugging with cement mortar 1:2 to match the line and level of sorrounding area for PRE-CONSTRUCTIONAL anti-termite treatmentwith Imidacloprid (30.50% SC) or approved equivalent. Plinth area in plan at GF shall only be measured (for all below specified steps) and paid. A guarantee bond of 10 years shall be furnished. A) Bottom surface and the sides of the excavation made for masonry foundations at the rate of 5 liters/Sq.m (wherever applicable)B) Top surface of the plinth filling of 5 liter/Sq.m of internal plinth area etc. complete.C) At the rate of 5 liter/ Sq.m to the internalvertical surface from original Ground level to top of the earth filled in the plinth.D) At the rate of 5 liter/ Sq.m to the externalvertical surfacebelow finished Ground level to the full depth of the filling complete.The work includes all costfor chemical, drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing finish etc all complete as per the direction of Engineer-In-Charge |
| 39 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 40 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 Sq.m |
| 41 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 42 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 43 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/Sq.m including pointing in white cement complete.8mm thick.Granite of any colour and shade |
| 44 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes. 4 mm thick glass pane (weight not less than 10kg/Sq.m). |
| 45 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes. 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm) |
| 46 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 47 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :100X58X1.90 mm |
| 48 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm |
| 49 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 50 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 51 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm |
| 52 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm |
| 53 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 54 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles ofapproved quality with necessary screws etc. complete. |
| 55 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 56 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 57 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m) |
| 58 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metr. |
| 59 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separatelyThree track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R4 series with frame (115mm & above) x (45mm & above) & both glazed and fly screen sash (44mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height above 1.8m) |
| 60 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Fixed window / ventilator with mullion / transom. Using R2 series with frame (39mm & above ) x (39mm & above) & mullion (39mm & above) x (60mm & above). (Height upto 1.2 metre) |
| 61 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles.Using R2 series with frame (39mm & above) x (39mm & above) & sash (39mm & above) x (60mm & above) & mullion (39mm & above) x (60mm & above). (Height upto 1.2 metre). |
| 62 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles.Using R4 series with frame (64mm & above) x (50mm & above) & sash (64mm & above) x (70mm & above) & mullion (64mm & above) x (70mm & above). (Height above 1.8 metre). |
| 63 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded). |
| 64 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c, including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and asper direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 Sq.m. |
| 65 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover |
| 66 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 67 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.MS Tube |
| 68 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer\"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 69 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 70 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 71 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sq.m including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 72 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sq.m including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 73 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 74 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipescomplete. |
| 75 | Providing and fixing Gysum false ceiling (12.5 mm) at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/Sq.m (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks) |
| 76 | Providing & fixing 8 mm thick Calcium Silicate false ceilingat all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ Sq.m (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture\"s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 77 | 15 mm cement plaster on the rough side of single or half brick wall of mix : : 1:4 (1 cement: 4 fine sand) |
| 78 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 79 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster |
| 80 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 81 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 82 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 Sq.m) over and including priming coat of exterior primer applied @ 2.20kg/10 Sq.m |
| 83 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 84 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 Sq.m. Over and including priming coat of exterior primer applied @ 0.90 litre/10 Sq.m. |
| 85 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 86 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 87 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 88 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 89 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 90 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 91 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 92 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-incharge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete. New work (Two or more coats) |
| 93 | Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-charge. |
| 94 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin-charge). |
| 95 | Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site. |
| 96 | Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately). |
| 97 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 98 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 99 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 100 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 101 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 102 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 103 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/Sq.m) |
| 104 | Providing and fixing 12 mm thick toughened glass panel of approved brand and manufacture, including making necessary arrangements for fixing requiredfittings, all complete as per direction of Engineer-in-charge |
| 105 | Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick) |
| 106 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 107 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 Sq.m. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 108 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per Sq.m |
| 109 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per Sq.m. |
| 110 | Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 111 | Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in superstructure above plinth level up to floor V level. Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 112 | Providing and laying half block masonry with factory made Precast concrete solid blocks of 100 mm thickness of grade M10 made of C&D waste from approved manufacturer in superstructure above plinth level up to floor V level: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 113 | Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 114 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 115 | Providing and constructing Solid concrete block masonry M-10 gradein C.M 1:6 (1cement, 6 coarse sand) with Solid blocks of 30x20x15 cm size or nearestand approved quality including scaffolding, raking out of joints,curing, cost and conveyance of all materials,labour, lead, lift, etc. complete for all types of masonry works below plinth level as directed by Engineer-in-Charge at all levels. |
| 116 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/Cu.m, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profileshall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 65 x 100 mm |
| 117 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/Cu.m and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 35 mm thick |
| 118 | Design and execution, of post tensioning works, including, decoiling the strands, cutting to the required lengths, supplying and laying of HT strands sheathing (GI corrugated ducts 0.3 mm thick) jointing with couplers, and inserting the strands, profiling, fixing live end anchorages, including the supply of stressing anchorages, suitable for 5-5 & 5-3 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of anti- bursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures, with required tools, plants, machineries and consumables etc., Rate to Exclude, for providing water, power, cementPT Slab |
| 119 | Design and execution, of post tensioning works, including, decoiling the strands, cutting to the required lengths, supplying and laying of HT strands sheathing (GI corrugated ducts 0.3 mm thick) jointing with couplers, and inserting the strands, profiling, fixing live end anchorages, including the supply of stressing anchorages, suitable for 5-5 & 5-3 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of anti- bursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures, with required tools, plants, machineries and consumables etc., Rate to Exclude, for providing water, power, cementPT beam |
| 120 | Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes of152mm dia machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge etc compete. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. |
| 121 | Towards Design, Detailing, Fabrication & Supply and Erection of Pre Engineered Steel Building. i) Primary & Secondary members (Columns ,Rafters, Purlins with Mezzanine) ii) Structural accessories like Bed Bolts, HSS bolts, Hill side Boltsiii) 1 Coat of Primer and 1 Coat of Enamel Paint |
| 122 | Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 123 | Supplying,fabrication and installing of swing louvers (Panel size 600mmx2800mm) made of6mm thick fundermax HPL panel rivetted with SS rivet to 50mm×50mm GI square frame as per the approved drawing, which shall be fixed on 5mm thick MS plate on RCC beam/lintel/floor etc with high quality bearing on top and bottom for movement and shaft/handle arrangement for swinging louvers. The work includes finishing frame work with Epoxy paint (two or more coats) applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete as per direction of Engineer-in-Charge .The cost includes all materials,accessories, labour,scaffoldling etc complete |
| 124 | Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. |
| 125 | Frosted Film - Supply & laying ofFrost/Privacy Film appoved design and color for All Glass Partitions and GLass doors. Rate including laying.(The successful manufacture should submit 10 years Warranty certicate to the clients. Product to be certified by Manufacturer\"s Representative) |
| 126 | Providing and fixing in position factory made Poly Urethane Foam (PUF) sandwich wall/roof/floor light weight solid core panels (50mm thick)made of core material of Polyurethane foam of density 40-42 Kg / M3 is sandwiched between two micro-ribbed layers of Galvalume sheets. The panels shall have a unique interlocking arrangement and are self-supportive. The panels to be placed against a concrete / masonry wall (or) against a proper steel fabricated structure.The interface joints, vertical and corner shall be further strengthened by using appropriate PPGL flashing and rivets. The panel shall fixed vertically and horizontally locked. Panels should be used as wall & roofing with additional structural support, steel or RCC depending upon the design.The work includes supply and installtion of nessarry flashings of required thickness as per the direction of Engineer In Charge All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except \"structural steel work\" which will be paid seperately). Non load bearing panels 50mm thick of required size |
| 127 | Providing and Fixing ofBuilding signages as per following specifications - Sign to be made shall be made of 3 mm aluminium / Acrylic Box Letters (100mm thick letters). Sign Face shall be in 3mm 0/40 Translucent Acrylic with Male / 10mm Water Proof Sun board Female Joint Adequate LED of Samsung Make shall be fitted with the required wiring & Waterproof Transformer to have the uniform Light. A provision for Weather Proof Box shall be made to keep the Transformers. The signages to be fixed on the structural ACP + MSframework with required sizes as per the design. The item includes design of supporting arrangement, fabrication, installation and commissioning the signages with structural framing including channels, angles, gusset plates and anchoring the frame by anchor fasteners to the Building. The structural framing should be painted with primer and enamel paints |
| 128 | Supply and fixing of Floor indication/ Fire exit/ Staircase/ Room indication signages of size 300mm x 150mm x 5mm or nearest size either hanged on ceilings/ fixed on walls with LED unit of approved make. The signage should be made up of acrylic material or fire resistant material on ACP.The signage should include a built-in UPS backup. It should be affixed to the existing background using appropriate chains and hooks, all complete as per the architectural design. |
| 129 | Providing and fixing of wall panelling with 19 mm thick 710 BWP fire retardant plywood conforming to IS: 5509 /10701 grade internal frame work over which 12 mm thick 710 BWPfire retardant plywood is fixed on. Exposed area finishing with 12.5mm thick gypsum board with ash wooden skirting, as per design approved by Architects. |
| 130 | Providing and FixingChannelled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side including Installing Skirting for Channelled wall panel of width 50mm or more as required by the Engineer-in-Charge.Finish off the edges using wooden moulding of matching colour for the wall Panel. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 21mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.Ceiling Installation : The panel shall be downwardly installed with tongue and groove mechanism using Inside clip on Prelude 43 with 24 mm wide T - section flanges having rotary stitching on all T - sections i.e., the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 43mm, 35mm and 30mm respectively. The deflection loading of the system shall be 17.8 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with deflection loading of 21.4kg/m. The end details of the main beam and cross tee shall be made of pre hardened steel and the cross tee is designed to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T - Sections shall be made of hot dipped galvanized steel of 100 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The grid shall be installed with suspension system of approved make. SUSPENSION SYSTEM accessories manufactured and supplied by approved manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre–Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. Additionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners. The rate is including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels. Wall Area Installation : The panel shall be mounted by tongue and groove mechanism using inside clip on Knauf aluminium extruded keel made of Grade 6063-T5 having dimensions 3000(L) x 24(H) x 15.5(W). The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. |
| 131 | Supplying and installation of Black out roller blinds as per the detailed Technical specification and deatiled drawing. Including all fixing charges and necessary fittings. Base rate of fabric is Rs. 700/- |
| 132 | Disposal of earth work by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 5 km for all lifts, complete as per directions of Engineer-in-charge. |
| 133 | Providing and applying antiskid epoxy of minimum 1mm thickness with UV resistant PU top coat and marking court lines with UV resistant paint.The work includes surface preparation with a suitable floor grinder, vacuuming dust from floor, priming the surface with epoxy floor primer,afterfilling cracks with epoxy grout ,proper mixing of epoxy paint components and applying etc all complete as per manufacturer\"s specifications and instruction of Engineer in charge |
| 134 | Procuring healthy grass free from weeds and foreign materials and laying on the soil medium as turfing,the rate include for grass cost, transport to site, cost and application of manure, planting, labour, supervision and maintenance for 2 months after plantingPearl Grass |
| 135 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Royal palm |
| 136 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Foxtail palm |
| 137 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Bismarkia palm |
| 138 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Jackfruit tree |
| 139 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Elenji tree |
| 140 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Coconut tree |
| 141 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Malpighia Topiary in steel mesh |
| 142 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Eugenia Topiary |
| 143 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Clerodendrum Inerme -Hedge |
| 144 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Murraya Exotica - Flower bush |
| 145 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Heliconia Caribea |
| 146 | Procuring and planting specified nursery grown trees, shrubs and other plants .Rates include plant cost,transport, cost of manure, planting, labour,supervision and maintenance for 2 months after planting.Areca tree |
| 147 | Supplying , stacking and spreading sludge / well decayed farm yard manure from thesource,Mixing earth and manure or in proportion specified or directed, Spreading ofdung manure or / and good earth in required thickness.and fine dressing the ground as per natural gradiantapproved by the engineer in charge incl. screening, loading, unloading, conveyance and stacking at site. |
| 148 | MEP |
| 149 | Providing and fixing wash basin with brass brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. Make:Jaquar, Kohler, Grohe, Cera high end series. |
| 150 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cisternMake: Jaquar, Kohler, Grohe, Cera high end series. |
| 151 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 152 | Providingandfixingstainlesssteeltoiletpaperholder. Make:Jaquar, Johnson, Cera high end series. |
| 153 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore.Make:Jaquar, Johnson, Cera high end series. |
| 154 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 155 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board510x1040 mm bowl depth 250 mm. Make: Jayana, Nirali, Carysil high end series. |
| 156 | Providing and fixing C.P. brass angle valve for basin trap and geyser points of approved quality conforming to IS:8931 15mm nominal bore Make: Johnson,Cera high end series. |
| 157 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (Above ceiling and Ducts)20 mm nominal outer dia Pipes |
| 158 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (Above ceiling and Ducts)25 mm nominal outer dia Pipes |
| 159 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (Above ceiling and Ducts)32 mm nominal outer dia Pipes |
| 160 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (Above ceiling and Ducts)50 mm nominal outer dia Pipes |
| 161 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Make: Astral, Supreme, Finolex, Prince15 mm nominal outer dia Pipes |
| 162 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Make: Astral, Supreme, Finolex, Prince20 mm nominal outer dia Pipes |
| 163 | Excavation for foundation/utility services upto 1.5 m depth including sorting out and stackingofusefulmaterialsand disposingoffthe excavated stuff with all lead and lift.(E)HardRock |
| 164 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each depositedlayer by ramming and watering. (Ramping by manual or mechanical means) |
| 165 | Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standardweight.(i)Squaremouthtraps.(B)150mmx100mmsizePorR type(make-Local ) |
| 166 | Constructing Brick masonry road Inspection chamber 450mm x 450mm x 775mm with horizontal grating complete.C.M.1:6.Foundation concrete150 mm thick in C. C.1:4:8oftrap metalsize 25mm to40mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and ms gratings on top. Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling, with cast in situ RCC slab in one single piece with fixing of CI-MH Frame and cover (incl cost of CI-MH Frame and cover) with 23 mm thick brick masonry wall in C.M.1:6.With precastslab in two parts 15mm. for rain water/storm water drainage |
| 167 | Construction of Manhole chambers(Inspection chambers) 600mm X 600 mm and depth 1.0 m in brickorbelastonemasonry,locallyavailableinC.M.1:6.Foundation concrete150 mm thick in C. C.1:4:8oftrap metalsize 25mm to40mm thick, inside cement plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS Bar etc. complete as given size) Upto 1 Mt. depth from G. L. to pipe invert level incl. complete civil works but excl. cost of excavation and refilling, with cast in situ RCC slab in one single piece with fixing of CI-MH Frame and cover (incl. cost of CI-MH Frame and cover) with 23 mm thick brick masonry wall in C.M.1:6.With precastslab in two parts 15mm. |
| 168 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of concealed flush tank,flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.. Make: Jaquar, Kohler, Grohe, Cera high end series. |
| 169 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin tap of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin counter top type 550x420mm with a 15 mm CP Brass single hole basin mixer. Make:Jaquar, Johnson, Cera high end series. |
| 170 | Providing, Fixing, Commissioning at site Urinal Partition with Curved shaped frosted glass fixing with brass screws,nuts , and washers complete including cutting and making good the walls and floors wherever requiredEtc complete. 900x450x10 mm tk. Make: Jaquar 1110uc/ equ. |
| 171 | Providingandfixingofgrabbars300mmStainlesssteelinphysically disabledtoiletincludingallnecessaryfitting,SSScrews&Accessories etc.Complted in all manners and satisfied to of EIC. complete. Make: Jaquar,Kohler, Grohe, Hindware, Cera high end series. |
| 172 | Providing and fixing of grab bars Vertical Swing 18-8 S, type-304, 18-gauge (1mm) stainless steel tubing with satin-finish. 1–1/4 (25mm) outside diameterwallmountedinphysicallydisabledtoiletincludingallnecessary fitting, SS Screws & Accessories etc.Complted in all manners and satisfied to of EIC.complete. Make: Jaquar, Kohler, Grohe, Hindware, Cera high end series. |
| 173 | Providing, Fixing, Testing and Commissioning at site ablution Health Spray Faucet with wall hook and 1.2 mtr. Chrome plated PVC hose pipe, etc. complete in all respects. Queo - Addons/Kohler/Grohe/jaquar |
| 174 | Providing, Fixing, testing and commissioning of Single Lever Diverter with provision for spout and over head shower with shower arm, shower rose, wall flange and spout, all accessories etc, complete.Queo - Johnson/ KOHLER /Grohe Metropole, jaquar OR Equ. |
| 175 | Providing and Fixing of Stainless SteelHand Dryer with all required connections and following specifications. Weld-free cover fixed to the base with two safety screws and lock withspecial speedflow key. Aluminium base. Includessilent-blockstodamp mechanicalvibrations.Fireresistant plastic UL 94-V0 fan scroll. High-speed motor with safety thermal cut-off.The motor revolutionscanbeadjustedmanuallybythepotentiometer.•Aluminium centrifugaldoubleasymmetricalinletfanwheel.Disconnectsautomatically after60secondsofcontinuoususe.Electronicinfrareddetectionsensor. Adjustabledetectionbypotentiometer(5-25cm).Ultra-flat:10cmdeep (complieswithADAregulations).complete.Make:Jaquar,Kohler,Grohe, Hindware, Cera high end series. |
| 176 | Providing, Fixing, testing and commissioning of shower cock with shower arm, shower rose, wall flange and spout, all accessories etc, complete.Queo - Johnson/ KOHLER /Grohe Metropole, jaquar OR Equ. |
| 177 | Providing and erecting water cooler having storage capacity 80Ltr. & cooling capacity 40 Ltr.per hour @ an ambient temp of 450C. The outlet temp. of the water should drop by 150 C within a hour, The water cooler should be comprisingof hermetically sealed compressor,fan motor,condensing unit, water tank surrounded by evaporating coil, thermostats, relay etc. complete withnecessaryinlet&outletconnection.Thebodyofwatercoolerwillbe made from Stainless Steel. |
| 178 | Supplying&erecting5stagesinglereverseosmosiswaterpurification system with M.S.powdercoated frame,pre filterhousingwith \"O\"ringpre sediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi,mentionwith40Osginlinetypepostcarbonfilterautolow&high pressureswitcheswithfollowingsizeofstoragetank&LPHcapacity& erectedasdirectedwith one year comprehensivemaintenance guarantee. [B] 25 Ltr / Hr with 30 Ltr. S.S. Pressure Tank |
| 179 | Supplying, Fixing, testing and commissioning at site in positionuPVC pipe -6kg/cm2) (IS:4985)Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, door bends, junctions, cowls, door TEE , Door Elboe where ever required etc.,complete. (Soil & Waste in Shaft) Make: Astral/Supreme/Ajay110 mm O.D. (6Kgf/cm2 IS:4985) |
| 180 | Supplying, Fixing, testing and commissioning at site in positionuPVC pipe -6kg/cm2) (IS:4985)Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, door bends, junctions, cowls, door TEE , Door Elboe where ever required etc.,complete. (Soil & Waste in Shaft) Make: Astral/Supreme/Ajay75 mm O.D.(6Kgf/cm2 IS:4985) |
| 181 | Supplying, Fixing, testing and commissioning at site in positionuPVC pipe -6kg/cm2) (IS:4985)Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, door bends, junctions, cowls, door TEE , Door Elboe where ever required etc.,complete. (Soil & Waste in Shaft) Make: Astral/Supreme/Ajay63 mm O.D( 4Kgf/cm2) Vent pipe in shaft |
| 182 | Providing, Fixing, testing and commissioning at site in position uPVC pipe( IS : 4985 ) With Rubber Ring or Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, etc. complete. (For Rain water pipes in shaft & Ceiling) Make: Astral/Supreme/Ajay110 mm O.D( 4Kgf/cm2)) Rain water pipe in shaft |
| 183 | Supplying, Fixing, testing and commissioning at site in position u PVC pipe of 6Kgf/cm2including PVC fittings with bosses where required e.g. tees, bends,door TEE , Door Elboe where ever requiredcoupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site universal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts ,washers, wherever required etc. complete.Make: Astral/Supreme/Ajay50 mm O.D. (6Kgf/cm2 (IS:4985) |
| 184 | Supplying, Fixing, testing and commissioning at site in position u PVC pipe of 6Kgf/cm2including PVC fittings with bosses where required e.g. tees, bends,door TEE , Door Elboe where ever requiredcoupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site universal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts ,washers, wherever required etc. complete.Make: Astral/Supreme/Ajay75 mm O.D. (6Kgf/cm2 (IS:4985) |
| 185 | Supplying, Fixing, testing and commissioning at site in position u PVC pipe of 6Kgf/cm2including PVC fittings with bosses where required e.g. tees, bends,door TEE , Door Elboe where ever requiredcoupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site universal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts ,washers, wherever required etc. complete.Make: Astral/Supreme/Ajay110mm O.D (6Kgf/cm2 (IS:4985) |
| 186 | Supplying, Fixing, testing and commissioning at site in position Deep Seal UPvc fabricated Multi floor trap (4”), with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, anchor fasteners etc. Complete in all respects. 50/75 mm dia outlet (In Ceiling)Astral/Supreme/Ajay |
| 187 | Supplying,Fixing, Testing and commissioning at site in position 150x150mm square C.P cast brass or stainless steel anti cockroach grating cover ss (304) of matching size of UPvc fabricated floor trap / multi inlet trap complete in all respects. Chilly/Eligna/ |
| 188 | Supplying,Fixing, testing at site in position 160mm dia square /circular grating Terrace rain water outlet(Cast Iron)(for 110mm dia pipe) |
| 189 | Providing, Fixing at sitein position uPVC Pipes (as per ASTMD – 1785 sch-40 ) of approved make For Cold Water Supply, complete with all necessary (ASTM D – 2466/2467) fittings (elbows, unions, tees, reducers, couplings, nipples etc) (External/ Inshaft)1 ¼ “ (32mm) dia. |
| 190 | Providing, Fixing at sitein position uPVC Pipes (as per ASTMD – 1785 sch-40 ) of approved make For Cold Water Supply, complete with all necessary (ASTM D – 2466/2467) fittings (elbows, unions, tees, reducers, couplings, nipples etc) (External/ Inshaft)1 1/2 “ (40mm) dia. |
| 191 | Providing, Fixing at sitein position uPVC Pipes (as per ASTMD – 1785 sch-40 ) of approved make For Cold Water Supply, complete with all necessary (ASTM D – 2466/2467) fittings (elbows, unions, tees, reducers, couplings, nipples etc) (External/ Inshaft)2” (50mm) dia(External / in Shaft) |
| 192 | Providing, Fixing at sitein position uPVC Pipes (as per ASTMD – 1785 sch-40 ) of approved make For Cold Water Supply, complete with all necessary (ASTM D – 2466/2467) fittings (elbows, unions, tees, reducers, couplings, nipples etc) (External/ Inshaft)2 ½” (65mm) dia(External / in Shaft) |
| 193 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings¾ \"\"(20mm) dia. |
| 194 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings1” (25mm)dia |
| 195 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings1 ¼ “ (32mm) dia. |
| 196 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings1 1/2 “ (40mm) dia. |
| 197 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings2” (50mm) dia |
| 198 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from Upvc ASTM Grade sch-40 pipes & uPVC sheet (600 mm long)1 ¼ “ (32mm) dia. |
| 199 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from Upvc ASTM Grade sch-40 pipes & uPVC sheet (600 mm long)1 ½” (40mm) dia(External / in Shaft) |
| 200 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from Upvc ASTM Grade sch-40 pipes & uPVC sheet (600 mm long)2” (50mm) dia(External / in Shaft) |
| 201 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from Upvc ASTM Grade sch-40 pipes & uPVC sheet (600 mm long)2 ½” (65mm) dia(External / in Shaft) |
| 202 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from Upvc ASTM Grade sch-40 pipes & uPVC sheet (600 mm long)3” (80mm) dia(External / in Shaft) |
| 203 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from Upvc ASTM Grade sch-40 pipes & uPVC sheet (600 mm long)4” (100mm) dia(External / in Shaft) |
| 204 | Supplying, Fixing, testing and commissioning at site Puddle Flangefabricated from 100 mm dia GI pipe with 6mm tk plate (600 mm long) for FIRE Tank |
| 205 | Supplying and Laying of pipes and conveying to position; cleaning, laying and jointing to true lines and gradients,with proper bedding uPVC pipe of IS 4985(6kgf/cm2)including jointing the pipe as per specification, testing the pipe line after installation all per provisions of IS: 1742-1983 (Code of practice for building drainage) complete as directed by the Employer160 mm OD (6/kg/cm2) |
| 206 | Providing and supplying of Class SN8Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smoothExternalAnnularCorrugatedandSmoothInternalSurfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as per EN:13476-3 including all local and central taxes, transportation,freightcharges,octroi,inspectioncharges,loading, unloading, conveyance to the departmental stores etc. complete.(ID 150 mmdiameter) Make: Astral, Supreme, Finolex, Prince160 mm OD (6/kg/cm2) |
| 207 | Providing and supplying of Class SN8Structured Wall polyethelene Piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smoothExternalAnnularCorrugatedandSmoothInternalSurfaces (Double Wall) for non-pressure underground Sewerage & Drainage application as per EN:13476-3 including all local and central taxes, transportation,freightcharges,octroi,inspectioncharges,loading, unloading, conveyance to the departmental stores etc. complete.(ID 150 mmdiameter) Make: Astral, Supreme, Finolex, Prince200 mm OD (6/kg/cm2) |
| 208 | ProvidingandfixingC.I.coverwithframe(Medium duty)450x450mm , total weight of cover and frame to be not less than 108kgFOR SUMP TANKS |
| 209 | ProvidingandfixingC.I.coverwithframe(Medium duty)450x450mm , total weight of cover and frame to be not less than 23 kg for OHT |
| 210 | Supply, installation, testing and commissioning of percolation well (Recharge well) including all work like drilling, compressor work, gravel packing, mud slurry disposal, clay packing and including of all materials like 300mm UPVC pipe, 300mm wire screens, 300mm collar joint, accessories, gravels, sand, sand filteration module etc. Site cleaning, mud pit, mud refilling for borewell must be in the contractor\"sscope.Contractorhastomaintainthepercolationwellupto three years after installation. |
| 211 | Supply,Installation, Testing and commissioning of Clear water transfer open well submerssible pump of adiquate hp with discharge 3 lps at 20 mtr head, SS body, ss shaft with bronze impeller mounted on a single base platewith controll panel and auto level controller.1 working+ 1 stand by |
| 212 | TERRACE DWS BOOSTER PUMP Duty Conditions of 6 lps @ 35 mtr - head(Each pump 3LPS 35 mtr Head - 2 Pump system-1 Working+1standby) Compact skid mounted Booster pumps with SS 304 casing, SS316 impeller , SS316 shaft , C I base and TEFC motorwith mechanicalseal. Pumpto be havesingle VFD logic controller. - Electriccontrol panel withlogic controller, relays, calibrated pressure switch, pressuretransmitter including cabling within panel, incorporating dry run protection, potential contacts forBMS integrating , sucton and discharge headers, pressure vessal 60 ltr capacity.1 working+ 1 stand by |
| 213 | Supplying and fixing of Borewell /tube well submerssible pump with panel, with CIconstruction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and50 Hz frequencyalong with pump protection starter with in built level controller for automatic operation of pumpset using float switch , The panel should have LCD screen showing Voltage / Ampere, Error log, Cascading operation , Pump run status , Auto faulty pump change over, Auto- Manuel selection etc . The panel should protect the pumpsetfrom over and under voltage, over and under load, dry protection , Phase reversal protection , Single phase prevention etcincluding cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge at all levelsCapacity :7m3/hrHead : 55 m |
| 214 | Supplying and fixing of Horizontal open well SUBMERCIBLE pump(1W+1S)ug to oht, with CIconstruction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and50 Hz frequencyalong with pump protection starter with in built level controller for automatic operation of pumpset using float switch , The panel should have LCD screen showing Voltage / Ampere, Error log, Cascading operation , Pump run status , Auto faulty pump change over, Auto- Manuel selection etc . The panel should protect the pumpsetfrom over and under voltage, over and under load, dry protection , Phase reversal protection , Three phase prevention etc -Capacity :24 m3/hrHead : 32 m |
| 215 | Fixing, testing and commissioning at site Automatic Dewatering system having 2 nos (1w+1s) Vertical Bottom suction submersible pump Having CI: body / Ci: impeller / SS : shaft . Each pump should be capable to deliver 3 lps @ 8mtr , having 0.75 kw /1hp /3phase motor . A wall mounting micro controlled automatic control panel should be provided for the working of pumpset as 1w+1s in cascading operation . The control panel should have LCD screen showing Voltage , Ampere , Pump running status , error logs, faulty pump indication etc. The panel should protect the pumpset from over and under voltage , over and under load , dry run, etc . Automatic operation of pumpset should be with float switch.(deliver pipeline size : 40mm )(Basement Pit ) |
| 216 | WATER TREATEMENT PLANTSupply, Installation, Testing & Commissioning of 14,000 Lpd Water Treatment Plant with Reverse Osmosis Process with all mechanical work like piping,mechanical components as follows but excluding the electrical works and civil work. a) PAC offChlorine Dosing system -1nos,Pressure sand filter FRP-1 no ,Activated carbon filter FRP-1no, |
| 217 | SEWAGE TREATMENT PLANT50 KLDModular Membrane Bioreactor (MBR) based Sewage Treatment Plant, Design Flow KLD 60.0 LPH 2000.0 Type Fully-Automated, Design MLSS mg/L 6000.0 – 8000.0.Membrane Membrane Bioreoctor (MBR) to provide an advanced level of organic andsuspended solids removal with 0.4 Microns pore isze, provides high filtrate quality.Operating Hours h 24.0, Design Flexibility % 30 - 100 with transfer pumps, air blowers, medias, membrine, tube settlers and all connected pipe lnes and necessary power connections and cubicle control panel in all respect. 3 years operation and maintanance of Sysytem is included,OUTLET ResultsParameter Unit Outlet ValuepH - 6.5-8.5TDS mp/I <2100TSS mp/I <20BOD5 mp/I <10COD mg/I <50Total Nitrogen mp/I <5Phosphorus mp/I <5Ammonia Mp/I <5Fecal Califorms MPN/ml Less than 1000 |
| 218 | Supply, installation, testing & commissioning of Single headed, S.S. ISI marked, ISO approved, oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63 mm dia instantaneous type female outlet complete with SSl cap and G.I. chain, twist release type plug and all accessories required for complete installation as per IS:5290(Type \"A\")Make: Safeguard, Minimax, New Age |
| 219 | Supply, installation and testing of Controlled Percolating (CP) Fire Hose ISI marked (IS:8423) 63 mm dia x 15 m long complete with instantaneous type S.S. 63 mm dia, ISI marked Male & Female couplings (IS:903) bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire including all accessories as required for complete installation. (For external hydrants) Make: Safeguard, Minimax, New Age |
| 220 | Supply, installation, testing and commissioning of compact type first aid fire hose reel with wall mounting swinging-type drum complying to EN 671-1 standards with ISI marked, 19 MM x 30 M long thermoplastic hose. 560 MM Dia powder coated sheet metal frame, water ways made from Non-Ferrous aluminium Alloy metal, High quality semi-rigid marked (Type-1 or Type-2) flame resistant, kink and abrasion resistant,thermoplastic Hose. Rotary operated leak proof, hydraulically crimped with corrosion-free Stainless Steel Grade 304 fitting, shut-off nozzle with shut, spray & jet functions, etc. and tested to 1.2 MPA( 12 Bar pressure) installation brackets, complete in all respects including all accessories as required for complete installation. INLET PIPE CONNECTION FROM RISING MAINS TO HOSE REEL SHALL BE PROVIDED WITH GI HEAVY CLASS PIPES WITH UNIONS OR WITH READY MADE TYPE FLEXIBLE RUBBER HOSE IN STANDARD LENGTH, HYDRAULICALLY FITTED END CONNECTIONS ETC .Make: Monsher, Minimax, New Age |
| 221 | Supply, installation, testing and commissioning of Gun-metal 4-way fire brigade inlet connection 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per I.S:904 including all accessories as required for complete installation. Make: Safeguard, Safefire, Minimax, New Age |
| 222 | Supply, installation, testing and commissioning of GI pipe (IS:1239 Part-I) Heavy duty Class \"B\" including cutting, welding etc. bends, elbows reducers, tees , clamps, hangers and all other accessories as required for complete installation etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. Note : Pipes up to and 50 mm dia shall be socket welded with DI fittings. For pipes inside the plant room80mm dia |
| 223 | Supply, installation, testing and commissioning of GI pipe (IS:1239 Part-I) Heavy duty Class \"B\" including cutting, welding etc. bends, elbows reducers, tees , clamps, hangers and all other accessories as required for complete installation etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. Note : Pipes up to and 50 mm dia shall be socket welded with DI fittings. For pipes inside the plant room100 mm dia |
| 224 | Supply, installation, testing and commissioning of wafer types\" iron , without lugs, lever operated Butterfly valves (PN 1.6) complete suitable with with bronze/gunmetal seat and all accessories required for complete installation. Make : Leader/ Audco/ Zoloto100 mm dia |
| 225 | Supply, installation, testing and commissioning of horizontal lift swing check type reflux non-return valves (PN 1.6) complete with matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes complete with all accessories required for complete installation. Make : Leader/ Audco/ Zoloto100 mm dia |
| 226 | Supply, installation, testing and commissioning of Brass Air release valve, size 25mm with threaded inlet & provided with ball type float complete with all accessories required for complete installation. Make : Leader/ Audco/ Zoloto |
| 227 | Supply, installation, testing and commissioning of industrial type pressure switch having 1/4\" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required. Make: Infoss/ |
| 228 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump). a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation,conforming to IS-325.c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 229 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump). a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation,conforming to IS-325.c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head Make : Kirloskar, Mather & Platt India Limited |
| 230 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump). a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation,conforming to IS-325.c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head Make : Kirloskar, Mather & Platt India Limited |
| 231 | Supply and installation of Weather proof Outdoor type hose cabinets fabricated from 14 SWG M.S. sheet with full glass door with locking arrangement (Water Proof), suitable to accommodate 2 nos.15 M long hose and 1 No branch pipe. Glass will be transparent Acrylic - 3mm thick. The cabinet shall be painted with coat of P O Red paint from outside and white paint from inside including all accessories as required for complete installation.(size shall be such that the above all items can be accommodated). (Double door type) as per industrial standards |
| 232 | Supplying, laying, fitting and fixing , testing and commissioning of under ground GI heavy duty \"C\" class pipe confirming to IS 1239 The pipes shall have anti-corrosive wrapping coating and a wrapping treatment with pipe coat 4 mm thickness, after applying one or more coats of Asphalt primer. Rates shall include cutting, welding etc. bends, elbows reducers suitable for pipe joints, clamps and all other accessories including excavation of earth to sufficient depth to install the pipes, the pipes buried in ground excavation and refilling etc.as per the specification and as required complete as required for complete installation etc. including cutting holes in RCC walls/slabs and making good the same adequately supported on rigid supports duly painted as required complete in all respect including allup to building rising mains and for yard hydrants ,100 mm dia |
| 233 | Supplying, laying, fitting and fixing , testing and commissioning of under ground GI heavy duty \"C\" class pipe confirming to IS 1239 The pipes shall have anti-corrosive wrapping coating and a wrapping treatment with pipe coat 4 mm thickness, after applying one or more coats of Asphalt primer. Rates shall include cutting, welding etc. bends, elbows reducers suitable for pipe joints, clamps and all other accessories including excavation of earth to sufficient depth to install the pipes, the pipes buried in ground excavation and refilling etc.as per the specification and as required complete as required for complete installation etc. including cutting holes in RCC walls/slabs and making good the same adequately supported on rigid supports duly painted as required complete in all respect including allup to building rising mains and for yard hydrants ,80 mm dia |
| 234 | Supply & installation of Pressure Gauge with 0-300 psi (0-21Kg/Sq.CM) range white background, black graduation scale with dual reading in Kg/Sq.CM & PSI, 1/4\" BSPT bottom entry 100 MM dial, PHOSPHOROUS BRONZE bourden tube, brass moving parts, polished stainless steel case with positive seal against weather, moisture & dust, hardened glass, glycerine filled type with syphon tube and isolation cock,Make: Fiebig / H guru |
| 235 | Providing & fixing double flanged flexicon rubber expansion joint with unit control of standard length as per manufacturers specifications suitable for working pressure rated (PN16) and test pressure to be 150 % rated pressure ofincluding rubber gaskets, flanges, nuts, bolts and washers complete as required100 mm dia |
| 236 | Providing & fixing double flanged flexicon rubber expansion joint with unit control of standard length as per manufacturers specifications suitable for working pressure rated (PN16) and test pressure to be 150 % rated pressure ofincluding rubber gaskets, flanges, nuts, bolts and washers complete as required80 mm dia |
| 237 | Supply and fixing Co2 type Fire Extinguisher of capacity 4.5 kg filled with Co2 Gas with control discharge mechanism ( squeeze grip type) fitted with Bend and Horn applicable on Class B and C class of fire. Manufactured and marked to IS 15683 with ISI marking and cylinders having the approval of Chief Controller of Explosives, and including all accessories as required for complete installation. |
| 238 | Supply and fixing of dry chemical powder type (DCP) fire extinguishers (ABC Type) of 4 Kg capacity, Pressurized with nitrogen, mfg. to IS:15683 with ISI mark fitted with pressure gauge, GM cap nozzle complete with initial charges and installation brackets and screws with ISI marks etc. complete as approved and instructed by the engineer in charge including all accessories as required for complete installation.. |
| 239 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 240 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 241 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 242 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 243 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 244 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 245 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 246 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 247 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 248 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 A switch |
| 249 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch |
| 250 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 251 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet |
| 252 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 253 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 254 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required1 or 2 Module (75mmX75mm) |
| 255 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required3 Module (100mmX75mm) |
| 256 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required4 Module (125mmX75mm) |
| 257 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required6 Module (200mmX75mm) |
| 258 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required8 Module (125mmX125mm) |
| 259 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 260 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 261 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door |
| 262 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 263 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way (4 + 36), Double door |
| 264 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 265 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (8 + 24), Double door |
| 266 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 267 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 268 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A |
| 269 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A |
| 270 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A |
| 271 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A |
| 272 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 273 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 274 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 275 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 276 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 277 | Earthing with CI. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 278 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 279 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 280 | Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required. |
| 281 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 282 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm |
| 283 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm |
| 284 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 285 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm |
| 286 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm |
| 287 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) |
| 288 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm (57mm) |
| 289 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240 sq. mm (62mm) |
| 290 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 400 sq. mm (82mm) |
| 291 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 292 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 293 | S\" type M.S. fan hook fabricated from suitable dia. M.S. rod duly painted for fixing of ceiling fan. The \"S\" type hook shall be fixed to steel bar in RCC ceiling. The ceiling shall be replastered with sand, cement & neeru etc. The cost of labours for chipping out ceiling upto steel bar & fixing of \"S\" hook & resurfacing the ceiling is included in the cost of item |
| 294 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way (4 + 36), Double door |
| 295 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)6 way (4 + 18), Double door |
| 296 | RMU |
| 297 | 11KV Outdoor Metering CubicleSITC of 11KV Outdoor Metering Cubiclecomprising of : 3 Nos. Current transformer (---/5A,15VA,class 0.2s) 1 No.Potential transformer(11KV /110V,100VA,class 0.2) Separate Compartment for CT/PT and TOD Meter with KSEB sealing facilityTTB with Fuse and CarrierProvision for incoming and outgoing XLPE 11 KV Cable and cable entry from bottom side withcable box suitable for 3 x 300 sqmm XLPE, 11KV Al: cable Enclosure-Powder coated CRCA sheet 2MM –IP 54 |
| 298 | 11KV TOD MeterSITC of 11KV/ √3 / 110V/ √3 , Class 0.2S , 15VA HT TOD Meter suitable for mounting outdoortype with all standard accessories.11 KV KSEB metering cubicle, lead wires etc.complete Carrying CT/PT units with TOD meter for testing and calibrating at the KSEB Testing Lab and taking back the same to the site isincluded in the scope of the contractor.Statutory testing fees shallbe remitted and will be reimbursed against producing original receipt |
| 299 | 11kV/433v, 630KVA USSHT Side comprising of : Incomer1 No. Indoor type 11kV, 630A, 26.3kA for 3 sec Horizontal Draw out VCB fittedwith Manual / Motor operated spring charging mechanism with 230V AC motor andmotor control switch, shunt trip coilof 24V DC, closing coil of 24V DC, Auxiliary Contact 6NO + 6NC, MechanicalON/OFF indicator,mechanical operation counter, master trip relay , auxilliary relay with multifunction meter, voltmeter with selectorswitch and 3 nos ammeter , necessary cast resin current transformer(45/5A , Cl:5P10,/ Cl: 1,15 VA-dual core),Potential transformer ( 11KV/110V , Cl:0.2 , 25VA ) Anti pumping feature, instantaneous IDMT relay withMicroprocessor based 3O/C + and 1E/F Protection relay, Strip Heater with thermostat , Power pack230V AC-24 V DC emergency OFF push button with Aluminium busbar and copper earthing strip Transformer comprising of : 11kV/433V ,630KVA ,50Hz,3phase,Vector Dyn 11 Resin Cast Indoor Transformer with off circuit tapping+5% to -5% in steps of 2.5% with winding temperature indicator and hooter with allstandard accessories as per IS 2026/77 on HV side Rigid Bus Bar interonnection to the 11KV LBS Panel and on LT side cable boxsuitable for 3 x 3.5 x300 sq.mm XLPE Al ; cablewith all standard fittings and accessories.Painting shall be carried out as per IS 631, impedance ofthe transformer shall be as per relevant standards. |
| 300 | NEUTRAL CTsSupply & Fixing of 1no Cast Resin Neutral CT with ratio 150/5A ,10VA, Cl.5P10, fixed in a suitable M.S box with view glass. |
| 301 | Supply of 11KV stranded compact circular aluminium conductor,conductors insulation screened withextruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.),cores laid up, inner sheath of PVC tape,galvanized steel flat strip armoured,and overall PVC sheathed cable conforming to IS 7098/11/85 with latest amendments & confirming to the GTP of Group Aof following sizes.3C - 150 Sq.mm HT Cable |
| 302 | SITC of D.G. set of following KVA 0.8 P.F.3 phase,50c/s,433V, comprising diesel engine, fuel tank, base plate,antivibration pad,battery, batterylead wire, battery charger self startingand self charging mechanism,and residential type silencer, control panel , in accoustic enclosure etc.with all standard accessoriesas per ElectricalInspectoratestandards and pollutioncontrol boardnorms. 320 KVA |
| 303 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)MAIN MV PANEL |
| 304 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)APFC PANEL |
| 305 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)SSB |
| 306 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)SB2 |
| 307 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)SB3 |
| 308 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)VRF PANEL |
| 309 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)SSB UTILITY PANEL |
| 310 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)LIFT PANEL |
| 311 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)PUMP PANEL |
| 312 | SITC of cubicle type mediumvoltage switch boards as per specificationsmentioned below, comprising ofACBs / MCCBs.,enclosed in 16 guage M.S.cubicle complete with angle iron frame work,panel doors , horizontal andvertical busbars and outgoing feeders,FRP separators, phase barriers,gaskets for door,feeders designations, etc.,Main Switch Board shall be capable of withstanding 50 KA fault level. The panelshall be suitable for erection on the floor using channel and fastners at regular intervals. All panels should have fire suppression system( Panel should confirm to BIS,IE rules,KSEI/ KSEB Standards)STP PANEL |
| 313 | SITC of15kwFrame with 3.4kw x 4 modules threephase in and out. Withindoor (IP21) with surge protection system with60 min backupbattery @ 10kva .8 PF loadwithmin VAH of16320 Dual string(SMF battery of reputed approvedmake. Input pf >0.99,with externalinput isolationtransformer, with IGBTrectifier andinverterDouble conversiontechnology, with inputvoltage range 320-460 @ full load, 50Hz Three Phase, output400V, 50HzThree phase, compatibility etc.15 KVA UPS - Three Phase |
| 314 | SITC of10kwFrame with 3.4kw x 3 modules threephase in and out. Withindoor (IP21) with surge protection system with60 min backupbattery @ 10kva .8 PF loadwithmin VAH of16320 Dual string(SMF battery of reputed approvedmake. Input pf >0.99,with externalinput isolationtransformer, with IGBTrectifier andinverterDouble conversiontechnology, with inputvoltage range 320-460 @ full load, 50Hz Three Phase, output400V, 50HzThree phase, compatibility etc.10 KVA UPS - Three Phase |
| 315 | SITC of5kwFrame with 3.4kw x 3 modules threephase in and out. Withindoor (IP21) with surge protection system with60 min backupbattery @ 10kva .8 PF loadwithmin VAH of16320 Dual string(SMF battery of reputed approvedmake. Input pf >0.99,with externalinput isolationtransformer, with IGBTrectifier andinverterDouble conversiontechnology, with inputvoltage range 320-460 @ full load, 50Hz Three Phase, output400V, 50HzThree phase, compatibility etc.10 KVA UPS |
| 316 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm |
| 317 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm |
| 318 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240 sq. mm |
| 319 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 400 sq. mm |
| 320 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 4 sq. mm |
| 321 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm |
| 322 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm |
| 323 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm |
| 324 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 4 sq. mm |
| 325 | SITC of following Light Fixtures/Ceiling Fans / Exhaust FansLED Downlight Recessed Fitting 15 W |
| 326 | SITC of following Light Fixtures/Ceiling Fans / Exhaust FansLED Surface Mount Fitting 12 W |
| 327 | SITC of following Light Fixtures/Ceiling Fans / Exhaust FansLED Linear Fixture 20Watts 4ftSurface Mounted |
| 328 | SITC of following Light Fixtures/Ceiling Fans / Exhaust FansMirror Light 5W |
| 329 | SITC of following Light Fixtures/Ceiling Fans / Exhaust FansCeiling Fan -1200 mm ( BLDC) |
| 330 | SITC of following Light Fixtures/Ceiling Fans / Exhaust FansExhaust Fan-450 mm |
| 331 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans20w Surface light |
| 332 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans11W Bollard Lights |
| 333 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans80W Flood Light |
| 334 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans6M Pole& 60W LED Flood/Street Light with necessary arms for light fixtures (Civil works including) |
| 335 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans18W Bulkhead Light |
| 336 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans18W Bulkhead Light |
| 337 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans18W Bulkhead Light |
| 338 | Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3. For 1,2,3,4 meter air terminal 16mm rod tapered to 10 mm aluminium rodmeter rod: Meets the requirement (IS/IEC 62305). Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. Stainless Steel Wall Clamp or 16 KG stone of 365 mm diameter, high level of stability.No. of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. Govt approved Indian labs test certificate required. Make: Cape/Dehn 2meterairterminalwith Interception Tip mountedon Stainless Steel WallClamp mounting accessories. |
| 339 | Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below:Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Make: Cape/DehnConductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters |
| 340 | Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below:Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Make: Cape/DehnConductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters |
| 341 | T-ConnectorsProvidingandfixingofCrossConnector/TConnector/FoldingClamp/ClampingShoe/ Expansion Piece: to route vertical down conductor /mesh formation made ofAluminiumFerruleusingscrewfreejoints.FoldingClamp/ClampingShoeformetalpanels(upto 20mmthicknessofthemetalframe):Foldingclamp/clampingshoeformetalframe thicknessupto20mm,madeofstainlesssteelSS304/316grade, conformstothe requirements accordingto (IS/IEC 62305). Expansion piece with connector:Forequalising temperaturerelatedlengthchanges.Necessaryonconductorslengthat every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: usingAluminiumFerrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC62305).Makesurealljointsare strong and willbe inspectedatsite.GalvanisedIronjointsarenotpermittedtoavoidriskofcorrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 342 | Test JointsProviding and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mmdiacopper coated solidsteel roundconductorhaving100micronsofcopperbonding.Conformstotherequirements according to(IS/IEC62305).Theenclosureshouldbeoutdoorglass-fibrereinforcedpolycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. Thetestlinkhastobestraightandneedsminimum4mountingscrewsforstrongjoints Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors permitted. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 343 | Ring EarthingProvidingandlayingcoppercoatedsteelsolidroundconductor10mmdiameterfrom earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotentialbonding.AftertestlinkneedstoberoutedinsideHeavydutyconduittoavoid touch potential till ground level. Govt approved Indian labs test certificate required.Make: Cape/Dehn |
| 344 | Welded JointsInstallation of Exothermic WeldJoints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305.Each under ground joints has to be wrapped withpetrolatum- coatedchemicalfibrefabrichaving1.1mmthickandwidth 50mm. Govt approved Indian labs test certificate required. Make: Cape/Dehn |
| 345 | Earth PitsProvidingandfixingofmaintenance freeEarthingsystemcomprises ofmolecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250microns asper UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend testwith out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016.Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impactpoint onthe bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollutethe environment and non corrosiveto earth rod. Thematerial shouldhave aresistivity less than0.2Ωm. It should be free from hazardous substances.The mineral compound is required to have minimum 17.5 Kg ofthe total composite.The compound should be chemically inert and needs to submitGovt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 50KN. The dimension shall be 320mmx 320mmx 190mm. Govt approvedIndianlabstestcertificaterequired. Make: Cape/Dehn |
| 346 | Earth PitsProvidingandfixingofmaintenance freeEarthingsystemcomprises ofmolecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250microns asper UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend testwith out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016.Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impactpoint onthe bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollutethe environment and non corrosiveto earth rod. Thematerial shouldhave aresistivity less than0.2Ωm. It should be free from hazardous substances.The mineral compound is required to have minimum 17.5 Kg ofthe total composite.The compound should be chemically inert and needs to submitGovt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 50KN. The dimension shall be 320mmx 320mmx 190mm. Govt approvedIndianlabstestcertificaterequired. Make: Cape/Dehn |
| 347 | Solar PV80KW Common load |
| 348 | Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 sq. mm |
| 349 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 sq. mm |
| 350 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 351 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.one run |
| 352 | Supplying and fixing of 32 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 353 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 354 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 355 | Supplying and drawing 2 pair, 0.5 sq mm FR PVC insulated copper conductor, un armoured telephone cable in the existing surface/recessed steel/ PVC conduit. |
| 356 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Telephone socket |
| 357 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required |
| 358 | Supply, installation, testing and commissioning ofIP based IRVarifocal dome Camera, 1/3\" CMOS, 4 MP, 2.7–12 mm MFZ, night vision compatible,IR range of 40 mtrs PoE, inbuilt micro SD card,Ethernet port, H.264, IP 66, ONVIF, UL, FCC & CE certified. All mounting accessories shall be included |
| 359 | Supply, installation, testing and commissioning ofIP based IRbullet Camera, 1/3\" CMOS,4 MP,night vision compatible,IR range of 40 mtrs PoE,inbuilt micro SD card,Ethernet port, H.264, IP 66, ONVIF, UL, FCC & CE certified. All mounting accessories shall be included |
| 360 | Supply, installation, testing and commissioning ofIP based IR PTZ camera, 1/3\" CMOS, 4 Megapixel,30X zoom, WDR,IR range of 200 Meters, inbuilt micro SD card,,Ethernet port,TDN, PoE, DWDR, BLC, AGC, DNR, OSD,H.264 High Profile dual-stream, ONVIF, Wall/corner Mount, IP-66. CE, FCC, C-Tick certified. All mounting accessories and mounting arm suitable for the location shall be included |
| 361 | 32 Channel IP Cameras support, 4 SATA Ports ( Loaded with HDD for 60 days storage), Maximum users - 20 or higher, IR Range of 100 Mtr, Ptotocols - HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, DDNS, FTP, SNMP, IP Search , ONVIF 2.4, SDK, CGI trigger Events - recording, PTZ, Tour, Alarm out, video Push, Email, FTP, Snapshot, Buzzer & Screen tips, recording Mode - manual, Schedule (Regular, Continuous), MD (video detection: motion detection, tampering, video Loss), Stop, Bandwidth - 200 Mbps, ONVIF 2.0 |
| 362 | 24 Channel IP Cameras support, 4 SATA Ports ( Loaded with HDD for 60 days storage), Maximum users - 20 or higher, IR Range of 100 Mtr, Ptotocols - HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, DDNS, FTP, SNMP, IP Search , ONVIF 2.4, SDK, CGI trigger Events - recording, PTZ, Tour, Alarm out, video Push, Email, FTP, Snapshot, Buzzer & Screen tips, recording Mode - manual, Schedule (Regular, Continuous), MD (video detection: motion detection, tampering, video Loss), Stop, Bandwidth - 200 Mbps, ONVIF 2.0 |
| 363 | 16 Channel IP Cameras support, 4 SATA Ports ( Loaded with HDD for 60 days storage), Maximum users - 20 or higher, IR Range of 100 Mtr, Ptotocols - HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, DDNS, FTP, SNMP, IP Search , ONVIF 2.4, SDK, CGI trigger Events - recording, PTZ, Tour, Alarm out, video Push, Email, FTP, Snapshot, Buzzer & Screen tips, recording Mode - manual, Schedule (Regular, Continuous), MD (video detection: motion detection, tampering, video Loss), Stop, Bandwidth - 200 Mbps, ONVIF 2.0 |
| 364 | Supply, installation, testing and commissioning of 20 100/1000 SFP ports + 4 Combo 10/100/1000BASE-T/SFP ports + 4 10G SFP+ ports, L2 Management Switch - Core Switch |
| 365 | Supply, installation, testing and commissioning of 24 port- Edge PoE switch |
| 366 | Supply, installation, testing and commissioning of 16 port- Edge PoE switch |
| 367 | Supply, installation, testing and commissioning of Patch Panel UTP Keystone- 32 Port- Fully loaded (Cat 5e,Cat 6 & Cat 6 A ) |
| 368 | Supply and installation of Cat 6 UTP patch cord, 1 mtr |
| 369 | Supply, installation, testing and commissioning of Server PC, Intel i7 processor, 24 inch LED monitor, Gigabit LAN port, USB port, 8GB DDR3 RAM,1TB HDD,1GB dual graphic card, 100/1000 LAN ports, optical mouse, Keyboard, DVD Writer. Genuine Win 8.1 Pro - Down grade to Win 7 professional, 24 inch LED monitor |
| 370 | Supply, installation, testing and commissioning of Surveillance/ ESATA compatible Hard Disk of 4TB capacity to achieve the total storage for the NVR server |
| 371 | Supply, Installation, Testing & Commissioning of 42 inch full HD LED monitor with resolution 1920X1080 pixel including wall mounting accessories (location: security room & central control room).Material shall be UL/CE listed |
| 372 | Supply and installation of wall mounted 22Urackincluding cable manager, power supply units etc.to accommodate NVR, ethernet switch patch panel etc in control room |
| 373 | Supply and installation of wall mounted 9Urackincluding cable manager, power supply units etc.to accommodate NVR, ethernet switch patch panel etc in control room |
| 374 | Supply, installation, testing & commissioning of column speaker6 watts |
| 375 | Supply, installation, testing & commissioning of voice alarm controller with all cables and accessories |
| 376 | Supply, installation, testing & commissioning of 480 W Booster Amplifier with all cables and accessories |
| 377 | Supply, laying and termination of2 Core x 1.5Sq.mm ArmouredAl.Mylar Screened FRLS Twin Twisted PVC Insulated cable along with all accessories. Accessories include cable glands, locknuts,saddle clips, cable tie & other hardwares to achieve cable termination and installation. Cable shall be terminated in speakers and amplifiers |
| 378 | Supply, installation, testing & commissioning of standard AV rack with 600mm Width, 800 mm Outer Depthand 36U Height |
| 379 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.RJ 45 socket |
| 380 | Supply and installation of Cat-6 shuttered 24 port patch panel |
| 381 | SITC of24 portunmanaged ethernet switch |
| 382 | Supply and installation of 9U rack withFront glass door, Rear Perforated door with handle Lock & key. Front/Rear 19\" mounting angles, top, bottom open, RAL 9005 with all other accessories |
| 383 | AX3600 WIFI6 Dual Band Multi Band Multi Gigabt Ceiling Mount Access Point / EAP660HD |
| 384 | Supply,laying and termination of 20 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray |
| 385 | Supply,laying and termination of 20 pair telephone terminal block housed in engineering plastic box with transparent hinged door |
| 386 | Supply,laying and termination of 10 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray |
| 387 | Supply,laying and termination of 10 pair telephone terminal block housed in engineering plastic box with transparent hinged door |
| 388 | Supply,installation,testring and commisioning of EPABX with the following specifications: 1.208 Analog Extensions with CLI Expandable to 512Ports2. 08 Port Analog trunk with CLI and Power Failure Transfer and with Protection modules.3. 02 PRI.4. 02 nos Operator Console with 30 Direct selection Keys each. 5. 08 Port Voice Guidance to announce Extension Busy status, Wake up call announcement and other important telephone features,Auto Attendant facility for Welcome message announcement.6. 02Nos -500 pair MDF(wall mountable)7. 01 No. Call Billing and monitoring Software.8. Charger/UPS with Batteries for backup of 1 hour. |
| 389 | Supply,installation,testring and commisioning of EPABX with the following specifications: 1. 08 Port Analog trunk with CLI and Power Failure Transfer and with Protection modules.2. 02 PRI.3 Charger/UPS with Batteries for backup of 1 hour. |
| 390 | 10 PASSENGER LIFTEquipement Details : Machine Roomless - Gearless No. of Unit : OneController Type : Micro Processor Based VVVF Capacity in Kgs/Persons : 544Kg/8PSpeed in MPM : 60mpm/1.0mpsDoor Opening Type :Centre Opening Sliding Door Operation : SimplexNo.of Stops : 3 (G,1,2)No.of Openings : 3 (G,1,2)Storey Served Front : 3 (G,1,2)Travel (mm) : 12900mmHoistway Size (mm) : 2570 (w) x 2000 (d)Cabin Dimemnsions (WxDxH) (mm) : 1300x1600x2200Pit Depth (mm) : 1500Overhead (mm) : 4100Entrance Dimensions (mm) : 800x2000Ceiling : SS Honeycomb finish with LED DownlightCar Front/Rear/Side Panel : SS Honeycomb finishHandrail : 38mm diaCar Doors : SS Honeycomb finishCar Flooring : Vinyl TileFloor Thickness : 1.5mm Thick Vinyl TileCar Sill : Extruded Hard AluminiumEntrance Frame/Landing Doors : SS Honeycomb finish |
| 391 | Supply, Installation ,testing and commissioning of the following minimum capacityAir-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along withsuitably rated starter panel & associated accessories, suitable interconnecting control cabling between IDUs, ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).All the structural corrosion resistant structural supports/concrete pedestals for mounting indoor/outdoor equipment\"s shall be included.Gas charging with refrigerent R 410 A shall be included at sufficient quantity recommended by the manufacturer. (Complete in all respects as per technical specification)174 HP Air cooled |
| 392 | Supply,installation,testing and commissioning of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower, multispeedmotor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.45 TR |
| 393 | Supply,installation,testing and commissioning of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower, multispeedmotor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.2 TR |
| 394 | Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with 19mm thick nitrile rubber class \"O\" insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part ofrefrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Complete in all respectsas pertechnical specifications.(Piping quantities are tentative and total cost quoted shall be suitable for site layout, unit location and installation requirement.)9.5mm |
| 395 | Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with 19mm thick nitrile rubber class \"O\" insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part ofrefrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Complete in all respectsas pertechnical specifications.(Piping quantities are tentative and total cost quoted shall be suitable for site layout, unit location and installation requirement.)15.9 mm |
| 396 | Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with 19mm thick nitrile rubber class \"O\" insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part ofrefrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Complete in all respectsas pertechnical specifications.(Piping quantities are tentative and total cost quoted shall be suitable for site layout, unit location and installation requirement.)19.1 mm |
| 397 | Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with 19mm thick nitrile rubber class \"O\" insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part ofrefrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Complete in all respectsas pertechnical specifications.(Piping quantities are tentative and total cost quoted shall be suitable for site layout, unit location and installation requirement.)22.2 mm |
| 398 | Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with 19mm thick nitrile rubber class \"O\" insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part ofrefrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Complete in all respectsas pertechnical specifications.(Piping quantities are tentative and total cost quoted shall be suitable for site layout, unit location and installation requirement.)28.6 mm |
| 399 | Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with 19mm thick nitrile rubber class \"O\" insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part ofrefrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Complete in all respectsas pertechnical specifications.(Piping quantities are tentative and total cost quoted shall be suitable for site layout, unit location and installation requirement.)41.5 mm |
| 400 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150mm width x 50mm depth x 1.6mm thickness (with 40 x 40 x 6mm GI angle supports) |
| 401 | Supply fixing testing and commissioning of Control wiring / network wiring using recommended quality of multicore cables in PVC Conduit |
| 402 | Supply and Installation of REFNET joints as per manufactures recommended standards for indoor units. |
| 403 | Supply and Installation of REFNET joints as per manufactures recommended standards for outdoor unit. |
| 404 | Supply, installation, testing and commissioning of suitable DiaPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan ofthe indoor units to nearest drain pointwith necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7milsfactory laminated glass clothalong with required pipe fittings and accessories like Bends, Tees, reducers, clamps,suitably supportedetc. complete in all respects as per the technical specifications.25mm Dia |
| 405 | Supply, installation, testing and commissioning of suitable DiaPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan ofthe indoor units to nearest drain pointwith necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7milsfactory laminated glass clothalong with required pipe fittings and accessories like Bends, Tees, reducers, clamps,suitably supportedetc. complete in all respects as per the technical specifications.32mm Dia |
| 406 | Supply,installation,testing&commissioningofcommunicationcablingin conduit between indoor unit to outdoor unit with all necessary support and accessories (Complete in all respects as per technical specification) |
| 407 | Supply, Installation ,testing and commissioningof PDI Compatible central controller, along with associated accessories for controlling entire VRF system & 25% spare capacity for future provisions with suitable interconnecting control cabling between IDUs, ODUs and central controller ,Power wiring with necessary supports andcomplete in all respects as per thetechnical specifications. |
| 408 | Supplying and fixing of 19 mm thick 40-60kg/m3 density,regular closed cell class 0 nitrile rubber insulation finished with 7 milsfactory laminated glass cloth ,anti-microbial protection. Butt all joints tightly and seal all breaks and joints by adhering glass cloth tape, fixing of insulation using OEM recommendedfixingdetails ,supports andadhesive, tapes etc. with R value less than0.6. (Complete in all respects as per technical specification)19 mm thick |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail