| 1 | Annual running operation & preventive maintenance of all clear water boosters, Fire Fighting, D.G. pump, dewatering,terrace pump sets,Fire alarm system,hydrants,Ventilation system ,Ten Passenger Liftin Community Hall Kishangarh and all internal/External electricalinstallations, watch and ward at DDA\"s Community hallKishangarhVillage , Sec.-A, Sarswati BlockatVasant Kunj & Mohammadpur , VasantGaon as per schedule,terms and conditions,specifications attached herewith, complete as required |
| 2 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the samein case of recessed conduit as requiredi) 20 mm |
| 3 | ii) 25 mm |
| 4 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.a) 3 x 1.5 sq. mm |
| 6 | 3 x 2.5 sq. mm |
| 7 | 3 x 4 sq. mm |
| 8 | 3 x 6 sq. mm |
| 9 | 3 x 10 sq. mm |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 11 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. ( For AC). |
| 12 | Supplying and Replacing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requiredi..)S.P. 5/6 amps, one way modular switch, ISI marked |
| 13 | S.P. 15/16 amps, one way modular switch, ISI marked |
| 14 | 6 pin 15/16 amps modular socket outlet, ISI marked |
| 15 | S.P. 5/6 amp switch P/T , ISI marked |
| 16 | S.P. 15/16 ampsP/Tswitch, ISI marked |
| 17 | 3 pin 5/6 ampsP/Tsocket outlet, ISI marked |
| 18 | 6 pin 15/16 ampsP/Tsocket outlet, ISI marked |
| 19 | Modular blanking plate |
| 20 | Modular base & cover plate for 8 module |
| 21 | Modular base & cover plate for 12 module |
| 22 | Modular base & cover plate for 4module |
| 23 | Modular base & cover plate for 6 module |
| 24 | Stepped type Modular Fan regulator (2 module) |
| 25 | Supplying and fixing PVC batten/ angle holder including connections etc. as required |
| 26 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 27 | Rewinding of ceiling fan with enamelled Insulated Copper wire of superior quality including dismantling,varnishing,Baking, providing/Replacing Bearings,reassembling,testingetc as required |
| 28 | Supplying and Replacing Metal body Heavy Duty Exhaust fan 300mm sweep (6 Poles)having Copper wound Motor, with louver shutter on existing wall,including making hole to suit the size,connections with 3x1.5 Sq mm PVC Insulated & PVC sheathed (Round)Wire,Testing,commissioning etc as required. |
| 29 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 63 (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulatorfor speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required.a) 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.A) Single Pole |
| 31 | DP MCB |
| 32 | Triple pole and neutral |
| 33 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63A |
| 34 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal/ coke and saltas required. |
| 35 | Providing and laying 25mm x 5mm G.I strip at 0.50 metre blew ground as strip earth electrode including connection/ terminating with G.I nut bolt ,spring, washer etc as required ( Joint shall be done by overlapping & with 2 set of G.I nut bolt & sping washer spaced at 50mm) |
| 36 | Servicing of Fire Pump engine,Engineno.1720016 ,72 H.Palong with Control panel including providing & replacing following spares,testing, commissioning etc as required.(as quated rate)i.)KOEL CARE Premium Genuine Oil 20 Liters CAN B5:B18-1 No.ii.)Lub Oil Filter(06.436.01.0.00)-2 Noiii)Fuel Filter Element(03.922.42.0.00)-2 No.iv)Pri Air Filter Element(F6.729.07.0.00)-1 No.v)Battery lead-2 Novi)KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN(82.020.35.1.26)-1 No |
| 37 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0Cwith required accessories :i)Pendent Sprinkler/Upright Sprinkler |
| 38 | Supplying of the following size,1.1KV grade , PVC Insulated,PVC sheathed/XLPEAluminium conductor , Armoured power cable.i)2core x 10sq. mm |
| 39 | i)2core x 16sq. mm |
| 40 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.i.)63 A |
| 41 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.i)100 A, 16 KA,TPMCCB |
| 42 | Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required.i.)4 pole MCCB,100A,30KA |