| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and for all lift as per direction of Engineer-in-charge by in charge - all kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 fine aggregate : 10 graded stone aggregate 40mm nominal size) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering , shuttering ,finishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 fine aggregate : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:4 (1 cement : 4 fine aggregate) |
| 5 | Centring and shuttering including strutting , propping etc. and removal of form work for - foundations, footings, bases for columns |
| 6 | Steel reinforcement for R.C.C. work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo - Mechanically treated bars Fe - 500D or more |
| 7 | 12mm Cement plaster of mix- 1:4( 1 cement: 4 fine aggregate) |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and all lift |
| 9 | Structural steel work in single section , fixed with or without connecting plate, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete |
| 10 | Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade - Two or more coats on new work |
| 11 | Providing and fixing bolts including nuts and washers complete |
| 12 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specifed by the manufacturere) wirh water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20mm thick cement mortar 1:4 (one cement : 4 fine aggregate) jointing with grey cement slurry @3.3 kg per sqm including grouting the joints withwhite cement and matching the pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge. Clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily - Glazed vitrified tiles Matt / Antiskid finish of size - size of tile 600x600mm |
| 13 | Providing and fixing stainless steel (grade 304) railing made of hollow tubes, channels, plates etc., including welding ,grinding. Buffing, polishing and making curvature (whereever required) and fitting the same with necessary stainless steel nuts and bolts complete. i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.,) |
| 14 | Applying priming coatswith primer of approved brand and manufacture, having low VOC VolatileOrganic Compound ) content - with water thinnable cement primer on wall surface having VOC content less than 50 grams / litre |
| 15 | Finishing walls with water proofing cement paint of required shade - New work (Two or more coats applied @ 3.84 kg / 10 sqm) |
| 16 | Designing, fabricating, testing, installing and fixing in positionCurtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of thebuilding , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shopdrawings for pressure equalisation or rain screen principle asrequired, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheetshall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled workingcurtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as per direction of Engineer-in-charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. Up to two decimal places. |
| 17 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing,staircase railing and similar works, including applying priming coat of approved steel primer - M.S.tube |