Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises to outside MD Land. |
| 2 | M & L for precast cement concretesolid building blocks or slabs 10cm thick with plain or interlocking joints with PCCtype C1 1:3:6using 20mm graded stone aggregatesetting in mortar 1:4 in walls, complete all as specified and directed. |
| 3 | M & L for Rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 surface finished even & smooth without using extra cement complete all as specified. |
| 4 | M&L for applying two coats of Oil bound distemper on walls including reparation of new plastered surfaces over a coat of primer complete all as specified and as directed. |
| 5 | M&L for Precast reinforced cement concrete 1:2:4 mix, type B-1 using 20 mm graded stone aggregate as in slabs supported on walls, as in platforms, shelves etc all as specified and directed. |
| 6 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams,etc.complete all as specified and as directed. |
| 7 | M&L for Mild steelTMT bars 10mm dia and over cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed. |
| 8 | M&L for 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade incl screed bed or bedding layer of mortar 20mm thick for laying floor finishesin CM (1:4) etc complete all as specified. |
| 9 | M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platforms, and other similar situations |
| 10 | Supplying and laying of 32 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in walls/trenches including cutting holes in walls and making good with CM (1:3) where required and taking down old tubing of any description complete all as specified and as directed. |
| 11 | Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in walls/trenchesincluding cutting holes in walls and making good with CM (1:3) where required and taking down old tubing of any description complete all as specified and as directed. |
| 12 | S&FRotational moulded PVC water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position all as specified in SSR part – Iincluding tank nipple and lidcomplete all as specified and as directed. |
| 13 | S&F in repairs of Ball valve 20mm dia high pressure PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed(Minimum wt. 210gms etc complete all as directed. |
| 14 | S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both endssuitable for CPVC pipe incuding connecting socket all as specified and directed. |
| 15 | S&F Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm→ |
| 16 | S&F Waste coupling of32 mm chromium plated for glazed ware basins/urinals with long screwed shanks and fly-nuts etc complete all as specified and directed. |
| 17 | S&F PVC waste pipe 32 mm bore, 900 mm long for urinal and wash basin etc complete all as specified. |
| 18 | M & L in repair for high density pipe 40 mm dia (HDPE)pressure rating 6 Kg / Sqcm fixed to wall and floors etcall as specified and as directed. |
| 19 | Cutting holes into or through brick walls not exc 150 sqcm built in lime mortarand stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required |
| 20 | Demolition of Plain cement concrete (un reinforced)in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 21 | M & Lfor coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in Apoxy Grout 2 to 3 mm spacer and filled withwhite cement mixed with matching pigment over and including 20 mm thick screed bed in CM 1:6 all as specified. |
| 22 | S & F in repair PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls / floorincl taking down old pipes of any description completeall as specified and as directed |
| 23 | S & F in PVC (SWR) bend of 75 mm dia . |
| 24 | S&F in 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed |
| 25 | S&F in CP Bib taps 15 mm cast copper alloy fancy typewith crutch or butter fly handle screwed down screwed for iron pipe or for brass ferrule etc complete all as specified. |
| 26 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 27 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixingwith stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessaryS Sscrews shall be paid separately) |
| 28 | S&F 100mm stainless steelbutt hinges, cold rolled medium weight |
| 29 | M & L forBrass handles, cast type, polished bright 150 mm long all as specified and directed |
| 30 | S & F of 125 mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified. |
| 31 | S&F of 100mm Aluminum anodised barrel tower bolts of extruded section complete all as specified. |
| 32 | S&F Brass Locks cupboard grade I,size 50 mm brass 4 levers |
| 33 | Taking downexisting tar felt, water proofing membrane etc of any description, any typeincluding loose plastering / screed , padding concreate etc if any and removing all loose particles with wire brushes, removing bitumen coating over original RCC slab by grinding, picking, , grinding of mother concrete slab to make surface smooth suitable for applying APP membrane as per manufacturer\"s instructions, including removal of debries to a distanceexceeding 1.5 km but not exceeding5KM complete all as specified and as directed. |
| 34 | Demolition of Cement concrete (unreinforced) of any description and in any position on roofs including removal of debries complete all as specified and directed. |
| 35 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed. |
| 36 | M&L 15mm thick plastering in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement. |
| 37 | Supply only chicken wire mesh for plastering of concrete surfaces wherever required incl necessary fixing arrangement complete all as specified and as directed |
| 38 | M&L forpreparation of new plastered surfaces of walls andapplying two coats of oil bound distemper over a coat of alkali-resiatant primer over 2 coats of wall care putty of total thickness less than 1.5 mm(for both coats) on plastered surrfaces complete all as specified. |
| 39 | M&L for PCC 1 : 1.5 : 3 type B-0 ( using 12.5 mm graded stone aggregate) mixed with water proofing liquid as in paddingon roofs to maintain slope as in correction layerof the depresed/ undulated portions and in roof kerbs or mud stops, rounded or chamfered on edges etc. including fininshing of exposed surface even and smooth without using extra cement,admixed with Liquid water proofing compound of FOSROC Nitobond SBR at 2% by weight of cement or with equivalent products of Pidilite, Dr fixit Super Latex / Asian paints/M/s M C Bauchemic / CIPY/ SIKA /Thermax / STPas approved by GE,to be applied as per manufacturer’s instructions.(Supply only of admixure will be measured and paid separely). |
| 40 | Supply only of Liquid water proofing compound of FOSROC Nitobond SBR at 2% by weight of cement or with equivalent products of Pidilite, Dr fixit Super Latex / Asian paints/M/s M C Bauchemic / CIPY/ SIKA /Thermax / STPas approved by GE,to be applied as per manufacturer’s instructions. |
| 41 | M&L for cutting out cracks to V-section upto 5 to 10 mm wide on wall surfaces cleaning out and grouting with Asian Paint Smartcare HybridPU sealant or equivalent. |
| 42 | Preparation of surfaces by sweeping cleaning and washing down with water to remove dust and loose particles over RCC slab for providing roof treatment, removal of unserviceable debris to outside MD land, and applying bitumen primer @0.30kg/sqm providing and laying4mm thick APP modified water proofing membrane weight not less than 4.0 kg/sqm reinforced with non woven polyster mat weight not less than 160gm/sqm having softening point not less than 140 Degree centigrade longitudinal tensile strength not less than 800N per 5cm tearing strength of 180N (by torch application method) with minimum of 100mm side lap and 150mm end laps by application of torch. Applying a coat blown grade hot bitumen 90/15 over the membrane @ 1.20kg/sqm and applying a coat of silar reflective bitumenous aluminium paint @ 0.1Kg/sqm all as specified and as per manufacturr\"s instructions. The membrane shall be inserted in to the wall /parapet wherever required. mouth of rainwater pipes, gutters shall be properly treated to avoid ingress of the water. Note: (i) The rate quoted by the contractor shall be included for dismantling and refixing of PVC water tanks hoisted on roof,taking down and refixing of water tubing and any other fittings on roof as required and no extra shall be paid.(ii) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company guarantee to be given by contractor after completion of water proofing work before payment. |
| 43 | S & F in repair PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls / floorincl taking down old pipes of any description completeall as specified and as directed |
| 44 | Dismantling wall and ceiling boards (fibre, pulp, insulation,etc.) or insulation boards/ slabs/ blankets any thickness, incl cover filltets and grids. |
| 45 | Providing and fixing 12 mm thick semi perforatedfalse ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum ) False ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture contents less than 2% humidity resistance of 99% NRCO.50 to .75 as pe IS8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanised @ 120 gms per sqm including both sides ) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross -T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600mm, suspened from ceiling using galvaized mild steel items ( galvanizing @ 80 grams per sqm) i..e 50mm long, 8mm outer diameter M-6 dash fastener 6mm dia fully threaded hanger rod upto 1000mm length and L-swhape level adjuster of size 85x25 x 2mm galvanised iron permieter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450 mm ceneter to centre and 50mm long dry wall wood screws. The kwork shall be carried out as per specifications, drawing and as per directions of the Engineer-in-charge. |
| 46 | M & L for complete removal of existing treatment and applying 1.5mm thick birla white wall care putty to fill up the depression and rubbing with sand paper to achieve a levelled and smooth surface and applying two coats of oil bound distemper over a coat of alkali resistant primer on prepared surfaces of internal walls complete all as specified and directed. |
| 47 | M& L for Plain Cement concrete Type C1 1:3:6 (20 mm graded Aggregate) as correction layer for tilingfinished fair on top without using extra cement. all as specified and directed. |
| 48 | S&F Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm→ |
| 49 | S&F Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm→ |
| 50 | S&F PVC waste pipe 32 mm bore, 900 mm long for urinal and wash basin etc complete all as specified. |
| 51 | Demolition of reinforced cement concrete of any description , any grade and in any position including reinforcement cut as required to facilitate demolition as in water tanks including base beams, shelves, platforms etc complete all as specified and directed. |
| 52 | Taking down Chowkhats or frames not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames) |
| 53 | Taking down Chowkhats or framesexc 1.5 sq. m but n exc 4 sq. meach but with shutters (without taking off shutters from the frames) |
| 54 | Taking up or down steel tubing 15 mmand connections, including cleaning for refixing or removal to store etc complete all as directed. |
| 55 | Taking up or down steel tubing 20 mmand connections, including cleaning for refixing or removal to store etc complete all as directed. |
| 56 | Taking up or down steel tubing 25 mm or 32 mm and connections, including cleaning for refixing or removal to store etc complete all as directed. |
| 57 | M&L for rendering 5 mm thick in ceilings in CM (1:3) finished even and smooth without using extra cement completeall as specified and as directed . |
| 58 | M&L 75 mm thick Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base flooring complete all as specified and directed by Engineer in charge |
| 59 | M&L for 25 mm thick PCC 1 : 2 : 4 type B-0using 12.5 mm graded stone aggregateas in screed bed in floors all as specified and directed. |
| 60 | M & L for precast cement concretesolid building blocks or slabs 10cm thick with plain or interlocking joints with PCCtype C1 1:3:6using 20mm graded stone aggregatesetting in mortar 1:4 in walls, complete all as specified and directed. |
| 61 | M&L for Precast reinforced cement concrete 1:2:4 mix, type B-1 using 20 mm graded stone aggregate as in slabs supported on walls, as in platforms, shelves etc all as specified and directed. |
| 62 | M&L for steel reinforcement TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columnshooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 63 | Material and labour for Glazed ceramic coloured tiles in vertical surfaces 600X300X 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10mm thick backing coat on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed. |
| 64 | M&L 18 to 20 mm thick machine cut polishedgranite stone slab of approved colour and shade as in platforms for counter sunk WHB including cutting holes of required shape for fixing of wash basins, fixed in cement mortar 1:4, pointing with epoxy groutof matching clour including grinding and polishing, moulding edges etccomplete all as specified. |
| 65 | Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specifiedincluding cutting grooves/ holesin brick walls for concealing and making good with CM (1:3) where ever required complete all as specified and directed. |
| 66 | Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specifiedincluding cutting grooves/ holesin brick walls for concealing and making good with CM (1:3) where ever required complete all as specified and directed. |
| 67 | S&F of1000lit capacityRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old exting tank complete all as specified and directed. |
| 68 | S&F of25 mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwedfor iron pipeall as specified and directed(Minimumweight15 mm- 142 Gms) |
| 69 | S&F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both endssuitable for CPVC pipe incuding connecting socket all as specified and directed. |
| 70 | Supply and fixing in repair vitreous china wash basin counter sunk type oval shape, 550x400 size (approx)white including 32 mm chromium plated waste fitting , fixing brackets, in granite slab complete all as specified and as directed. |
| 71 | S&F in repairs 32/40 mm dia brass chromium plated bottle traps for wash basin with inlet and outlet screwed for pipe or connections including necessary packing union and cap and 32 mm dia PVC flexiable waste pipe complete all as spsecified and directed. |
| 72 | S&F in repair vitreous china wash down water closet (pedestal pattern) white (excluding fixing bolts, flushing cistern ) with plastic water closet seat including fixing of flush pipe to pedestal pan including all joints complete all as specified and directed. |
| 73 | S & F in repair10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve, float and handle including brackets. |
| 74 | S & F in repairs vitreous China squatting pan,‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe |
| 75 | S&F in repair vitreous China Urinal, half stall type, with and including waste couplingCP of 40 mm and32 mm dia PVC flexiable waste pipe, all fixing acessoriescomplete. |
| 76 | S&F 15 mm pillar taps fancy type cast copperalloy with capstan heads, chromium plated screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipes complete all as specified and directed. |
| 77 | S&F in repair chromium plated urinal spreader of selected best qualityfor fixing with 15mm dia pipe complete all as specified and directed. |
| 78 | S&F in repair Brass Chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 79 | S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 80 | S&F in repair brass chromium plated shower rose 125mm with or without swivel joints including fixing to steel pipe or union complete all as specified and directed. |
| 81 | S&F 15 mm bore Bib taps chromium plated fancy type , cast copper alloy with crutch or butterfly handle, screwed down, screwed for CPVC pipe 20 mm outer dia including suitable connector socket all as specified. |
| 82 | S&F 15 mm bore Two way Bib taps chromium plated fancy type , cast copper alloy with crutch or butterfly handle, screwed down, screwed for CPVC pipe 20 mm outer dia including suitable connector socket all as specified. |
| 83 | S&F 15 mm bore Stop valves / angle valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed for CPVC pipe 20 mm outer dia including suitable connector socket all as specified. |
| 84 | S & F in PVC connections 15mm size with PTMT nuts of length 450mm. |
| 85 | S&F of5mm thick looking mirror of selected quality glass, mounted on 12 mm thick pvc sheetand fixed with wooden plugs and chromium plated screws including necessary joining cleats, glazing clips, rubber packing with anodised aluminium beading etc complete all as specified. |
| 86 | S & F in repair PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls / floorincl taking down old pipes of any description completeall as specified and as directed |
| 87 | S&F in repairs 110mm bore PVC SWR bend of 110 mm dia. |
| 88 | S&F in repairs 110mm bore PVC SWR bendwith acces door complete all as specified |
| 89 | S&Fin repairs 110mm bore PVC SWR junction single (single T)equal or unequal |
| 90 | S&F in repairs PVC (SWR) 110 mm dia Vent cowl |
| 91 | M&L in repairs for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and directed. |
| 92 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 93 | S&F ofProviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed. |
| 94 | S&F ofFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardanand fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.suppling & fixing in opening as per specification & drawing all as specified and directed. |
| 95 | S&F of 100mm stainless steelbutt hinges, cold rolled medium weight complete all as specified. |
| 96 | S&F of 100mm Aluminum anodised barrel tower bolts of extruded section complete all as specified. |
| 97 | S&F of 100mm extruded aluminium anodised alloy handles fabricated type complete all as specified. |
| 98 | S&F250 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified. |
| 99 | S&Fpowder coatedaluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 100 | S&F 4mm thick Figured glass, pin head type and glazing fixed in aluminium frames with rubber beading/gasket in squares n exc 0.5 sq. m in each pane complete all as specified. |
| 101 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with alluminium wire staples |
| 102 | S&F Automatic hand dryer is made of ABS material for ensured durability and it is both corrosion-proof and lightweight,environmentally-friendly material, At the same time, this material makes the hand dryer lightweight complete as spcified & directed. |
| 103 | S&F fancy type Glass Cornar Cabinets complete as spcified & directed |
| 104 | M & L for preparing new plastered or unplastered surfaces on walls including cornices and applying two coats of distemper over a coat of alkali resistant primercompleteall as specified and as directed . |
| 105 | M & L for preparation of newly plastered surfaces & applying threecoatsof white wash on ceilings complete as specified & directed |
| 106 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earthor broken rubble mixed with earth around, in layers not exceeding 25 cm or removing the earth in hard/dence soilall as specified and directed. |
| 107 | M&L for Plain cement concrete 1:3:6, Type C2 using 40mm graded stone aggregate as in foundation, filling and mass concrete etc., complete all as specified and directed. |
| 108 | S&F of Structural Steel work as columns, posts, stanchions etcusing ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed. |
| 109 | S&F of Structural Steel work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters , vertical posts, etc fixed with angle cleats or other connecting plates, cleats etc. using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed. |
| 110 | S&F of Structural Steel work in tubular trusses including special shaped washer etc.. using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed. |
| 111 | M&L for Rolled mild steel inPlates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 112 | S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed. |
| 113 | M&L for preparation of new steel surfaces and applyingtwo coats of synthetic enamel paint over a coat of red oxide zinc crome primer on Surfaces of any description,over 10cm in width or girth, not otherwise described complete all as specified and as directed. |
| 114 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard / dense soil all as specified and directed. |
| 115 | Returning, filling in, hard / dense soil including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed. |
| 116 | Removing excavated material (soils) exceeding 1.50 km but not exceeding 5 km and depositing where directed all as specified and directed. |
| 117 | M&L for pre-cast cement concrete block masonry with solid blocks exc 10 cm in width, PCC 1:3:6 mix type C-1 using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed. |
| 118 | M&L for rendering 15 mm in Cement Mortar 1:4 on fair faces of brick work or concrete surface walls finished fair and even complete all as specified and as directed. |
| 119 | M&L for preparation of new surfaces plastered or unplastered walls and applying two coats of cement base paint over a priming coat all as specified and directed. |
| 120 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil. |
| 121 | M&L for hardcore of gauge n exc. 63 mm of broken stone boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. |
| 122 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone agg) 75mm thick as in floor sub base etc as specified directed. |
| 123 | M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 20 mm thick cement screed base in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 124 | M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, platforms, shelvesand like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compleet all as specified and directed. |
| 125 | M&L for surface excavation n. exc.30 cm deepand averaging 15cm deep and getting out in hard/donse soil, complete all as specified and directed. |
| 126 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and as directed. |
| 127 | M& L hardcore of broken stone or boulders of guage n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and well rammed to a true surface, complete all as specified and directed. |
| 128 | M& L for150 mm thick Plain Cement concrete Type A 1 ( 1: 1 /1/2 :3) (20 mm graded Aggregate) as in surface fair and even usingcomplete all asspecified and as directed. |
| 129 | M& L for 100 mm thick Plain Cement concrete Type D2 1:4:8 (40 mm graded Aggregate) as in sub base flooring complete all as specified and as directed. |
| 130 | M&L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound. |
| 131 | M& L for Pre-cast cement concrete block masonry with type C1 (1:3:6) using 20 mm graded stone aggregate solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and as directed. |
| 132 | M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement with using WPCcomplete all as specified. (WPC shall be measured and paid separately). |
| 133 | M& L for 100 mm thick Plain Cement concrete Type D2 1:4:8 (40 mm graded Aggregate) as in sub base flooring complete all as specified and as directed. |
| 134 | S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under \"Structural Steel\") |
| 135 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 136 | M&Lapplying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparatio of new steel or iron surfaces exc 10 cm width or girth, complete as as speciied. |
| 137 | Taking down old, unsv aluminium/copper point wiring (light, fan, socket or power) complete, incl fixture & fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-Charge. |
| 138 | Taking down old sub-main wiring incl fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-Charge. |
| 139 | Disconnecting/dismantling of old existing un serviceable DB\"s any type/way 240/415 Volts with their old/un serviceable burnt MCCB/MCB\"s etc. complete all as specified and directed by Engr-in-Charge. NOTE for Item Nos above : Cost of making good the disturbed surfaces is deemed to be included in the unit quote rates. |
| 140 | M & L for point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade), ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of Conduit: Polycab/Finolex/Precision/ Modi Make of cable : Havells/Polycab/Finolex/KEI/Precision/Modi(a)One Light/fan etc. point controlled by one switch 5/6 Amps. |
| 141 | b) Description all as per Item No above but with FRLS PVC insulatedcopper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket complete. |
| 142 | (c)One switch socket outlet point 5/6 Amps on independent board.NOTE : 1) Modular metal flush boxes shall be measured & paid separately.2) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates. |
| 143 | M & L for sub-main wiring alongwith earth wire of size (2 x 2.5) sq. mm + (1 x 2.5) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of Conduit: Polycab/Finolex/Precision/ModiMake of cable : Havells/Polycab/Finolex. NOTE : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates.Make of Conduit: Polycab/finolex/Precision/Modi |
| 144 | S & F Modular switch, one way, 6 Amp, 1 Module, 240 volt complete all as specified and as directed. Cat No : ACVSXXW061, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 145 | S & F Modular shuttered socket outlet 3 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKSWW063, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/PolycabNote for Item Nos above : Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned. |
| 146 | Supply & Fixingand concealing modular metal flush boxsuitable for fixing switches/sockets of 3 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 147 | Supply & Fixingand concealing modular metal flush boxsuitable for fixing switches/sockets of 6 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 148 | Supply & Fixingmodular cover platesuitable for fixing switches/sockets of 3 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 149 | Supply & Fixingmodular cover platesuitable for fixing switches/sockets of 6 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/PolycabNOTE for Item Nos above : The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets. |
| 150 | S&F ceiling rose surface PVC/ Polycarbonate, Isolated body with face Bakelite three terminal complete all as specified and directed. Make: Havells/Legrand/Anchor |
| 151 | S&F Surface and wall mounted LED batten 10 watts 2 feet long, extruded aluminium housing providedfor efficient heat dissipation & integrated electronic driver including connecting up with and including twin/three core twisted flexible cable of suitable size in flexible conduit all as specified and as directed. Make : LUKER, Cat No LT510P or techno-commercially equiv in Havells/Jaguar/Philips. |
| 152 | S&F Surface and wall mounted LED batten 20 watts 4 feet long, extruded aluminium housing providedfor efficient heat dissipation & integrated electronic driver including connecting up with and including twin/three core twisted flexible cable of suitable size in flexible conduit all as specified and as directed. Make : LUKER, Cat No LKM2240 or techno-commercially equiv in Havells/Jaguar/Philips. |
| 153 | Supply and fix energy saving high power LED building security light of 30W made up of pressure die cast aluminum housing with embedded PC cover having top opening, seperate driver compartment with IP66 protection, IK-09 and making electric connections in flexible conduit with & incl GI Pipe bracket of appropriate dia & necessary fixing arrangements like clamps, nuts, bolts, washers etc. complete all as specified & as directed. Make : LUKER, Cat No LSTE030S or techno-commercially Equivalent in Havells/Jaguar/Philips. |
| 154 | S & F LED square shape (2\" x 2\") slim ceiling SURFACE light fitting 40 W or next higher rating, CRI > 80, CT>5700 K (White), integrated type, with high efficiency electronic driver, surge suppressor/protection & high brightness LEDs, with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size all as specified and as directed. Cat No : LKMSRS40N of make Luker or techno-commercially equiv in Havells/Jaguar/Philips. |
| 155 | S & F LED square shape (2\" x 2\") slim ceiling RECESS light fitting 40 W or next higher rating, CRI > 80, CT>5700 K (White), integrated type, with high efficiency electronic driver, surge suppressor/protection & high brightness LEDs, with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size all as specified and as directed. Cat No : LKMSRS40N of make Luker or techno-commercially equiv in Havells/Jaguar/Philips. Imp Note for Item Nos 151.00 to 155.00 above : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 156 | S & F SPN DB, 4 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 157 | S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 158 | S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA.Make-L&T/LEGRAND/SIEMENS/ABB. |
| 159 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. Make of GI Pipe : TATA/Jindal/PrakashNOTE : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory. |
| 160 | M & L for laying earth continuity conductor or main earthing lead of 4 mm dia GI wire, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required all as directed and specified. |
| 161 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), for earth lead protection etc. of bore 15 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. |
| 162 | S&F Ceiling Fans complete with blades, down rods, electronic regulator (compatible for BLDC Fans) & accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, 5 Star rated with BLDC mtor complete all as specified & as directed. NOTE : Quoted rate is deemed to be inclusive of the cost for transportation of old/unsv C/Fans to MES Storeyard. Make : HAVELLS/BAJAJ/USHA/KHAITAN |
| 163 | Supply, install, commissioning & testing of Exhaust fan, metal body with automatic back shutter louvers 300 mm sweep, 1400 RPM or more, Air Delivery not less than 1850 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose and making of suitable sized hole in the wall/existing window/ventillator/other surfaces etc. for fixing of the exhaust fan & making good the disturbed surfaces (if any) complete all as specified & as directed. Make : Havells, Cat No: Ventil Air - DB or techno-commercially equivalent in Usha/Bajaj/Khaitan. Note :- (i) The cost of making hole in walls/other surfaces & making good the disturbed surfaces incl any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates.(ii) The cost of transportation of old unsv Exfan to MES storeyard is deemed to be included in unit quoted rates. |
| 164 | M & L for sub-main wiring alongwith earth wire of size (4 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) of minimum size 25 mm dia with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. Make of cable : Havells/Polycab/Finolex/KEI. Make of Conduit : Polycab/Finolex/Modi/Precision. NOTE : 1) Four runs of PVC wire, One run of Earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Cost of Modular metal flush boxes (if any for junction inspection) is deemed to be included in the unit quoted rates. 3) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps/saddles of appropriate sizes with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire. |
| 165 | M & L for surface sub-main wiring alongwith earth wire of size (2 x 2.5) sq. mm + (1 x 2.5) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. Make of Conduit : Polycab/Finolex/Modi/Precision. NOTE : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases & making good the disturbed surfaces (if any) is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates.5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire. |
| 166 | S & F Modular switch, one way, 6 Amp, 1 Module, 240 volt complete all as specified and as directed. Cat No : ACVSXXW061, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 167 | S & F Modular switch, one way, 16 Amp, 1 Module, 240 volt with Indicator complete all as specified and as directed. Cat No : ACVSXXW161, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 168 | S & F Modular shuttered socket outlet 3 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKSWW063, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 169 | S & F Modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKCWW163, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/PolycabNote for Item Nos 166.00 to 169.00 : Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned. |
| 170 | Supply & Fixingand concealing modular PVC surface boxsuitable for fixing switches/sockets of 8 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 171 | Supply & Fixingand concealing modular metal flush boxsuitable for fixing switches/sockets of 3 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 172 | Supply & Fixingmodular cover platesuitable for fixing switches/sockets of 3 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 173 | Supply & Fixing modular cover plate suitable for fixing switches/sockets of 8 modules all as directed. Model-verona of make CRABTREE (Havells) or techno-commercially equiv in Legrand/Anchol Roma/Polycab |
| 174 | S&F Surface and wall mounted LED batten 20 watts 4 feet long, extruded aluminium housing providedfor efficient heat dissipation & integrated electronic driver including connecting up with and including twin/three core twisted flexible cable of suitable size in flexible conduit all as specified and as directed. Make : LUKER, Cat No LT520P or techno-commercially equiv in Havells/Jaguar/Philips.Imp Note for Item Nos : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 175 | S & F SPN DB, 4 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 176 | S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 177 | S&F rigid non-metallic PVC Conduit (medium grade) of size 25 mm dia, ISI Marked of colour as approved by Engr-In-Charge inclusive of connected fittings with & including necessary fixing arrangements such as PVC saddles, couplers, lock nuts, pipe hooks etc. suitable for drawing electric cables complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. NOTE : 1) Quoted rate is deemed to be inclusive of cost of drawing electric cables. 2) Electric cables shall be measured & paid separately. |
| 178 | S&F weather proof copper multicore, PVC insulated & PVC sheathed industrial flexible cable for outdoor applications conforming to IS : 694 of size 4.0 sqmm 3 core of 1100 volts grade. Make of cable : Havells/Polycab/Finolex/KEI |
| 179 | S&F Tripple Pole & Neutral sheet metal enclosure with a three pin & earth plug & socket with one Tripple pole MCB, \"C\" Curve, 10 KA, 415 V, 32A fixed flush to wall complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge.NOTE : 1) Make of TPN Metal Plug & Socket & MCBs shall be the same. 2) Cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail