| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | 2.3.1Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods,watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers, androlling every 3rd and top-most layer with power roller of minimum 8 tonnes anddressing up, in embankments for roads, flood banks, marginal banks, and guidebanks etc., lead up to 50 m and lift up to 1.5 m :All kinds of soil |
| 3 | 2.1.1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil |
| 4 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 5 | 50.2.25.1Filling with contractor\"s own earth ( excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge |
| 6 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | 16.1Preparation and consolidation of sub grade with power road roller of 8 to 12 tonnecapacity after excavating earth to an average of 22.5 cm depth, dressing to camberand consolidating with road roller including making good the undulations etc. and rerollingthe sub grade and disposal of surplus earth with lead upto 50 metres. |
| 8 | 15.23.2Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm |
| 9 | 15.9.2Demolishing stone rubble masonry manually / by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer -in- Charges:In cement mortar |
| 10 | 15.3Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge. |
| 11 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 12 | 5.1.3Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 13 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 14 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 15 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 16 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 17 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 18 | 5.9.2Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 19 | 50.6.2.3Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cmor nearest available size confirming to IS 2185 part I of 1979 for super structureabove floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1cement : 6 coarse sand) etc complete |
| 20 | 13.7.112 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1cement : 3 fine sand) |
| 21 | 13.7.212 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1cement : 4 fine sand) |
| 22 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 23 | 22.6Providing and laying water proofing treatment on roofs of slabs by applying cementslurry mixed with water proofing cement compound consisting of applying : a) aftersurface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with waterproofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be lessthan 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarsesand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by watercuring for 48 hours. The entire treatment will be taken upto 30 cm on parapet walland tucked into groove in parapet all around. d) fourth and final layer of brick tillingwith cement mortar (which will be paid for separately. For the purpose ofmeasurement the entire treated surface will be measured) |
| 24 | 13.1015 mm cement plaster 1:3 ( 1 cement :3 coarse sand) finished with a floating coat ofneat cement on the rough side of single or half brick wall. |
| 25 | 14.75Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under,including cutting the patch in proper shape, raking out joints and preparing plasteringthe wall surface with white cement based polymer modified self curing mortar,including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 26 | 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 27 | 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work |
| 28 | 10.16.1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 29 | 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 30 | 50.12.2.5Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved bythe Engineer in charge and should be supplied in a single length of 12 M or as decideby the Engineer in charge. The sheets shall be fixed using self drilling/ self tappingscrew of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal/vertical / curved surface, but excluding the cost of purlins, rafters, trusses, andincluding cutting to size and shapes where ever required. |
| 31 | 12.51.1Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm(+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns using self drilling/ self tapping screwscomplete:Ridges plain (500-600 mm) |
| 32 | 8.32Designing, fabricating, testing, installing and fixing in position Curtain Wall withAluminium Composite Panel Cladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to make itwatertight including checking of all the structural and functional design.(b) Providing,fabricating and supplying and fixing panels of aluminiumcomposite panel cladding in pan shape in metalic colour of approved shades made outof 4mm thick aluminium composite panel material consisting of 3mm thick FR grademineral core sandwiched between two Aluminium sheets (each 0.5mm thick). Thealuminium composite panel cladding sheet shall becoil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resincoating of approved colour and shade on face # 1 and polymer (Service) coating onface # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weathersilicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot DipGalvanised with serrations and serrated washers to arrest the wind load movement,fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylonseparators to prevent bi-metallic contacts all complete required to perform as perspecification and drawing The item includes cost of all material & labour component,the cost of all mock ups at site, cost of all samples of the individual components fortesting in an approved laboratory, field tests on the assembled working curtain wallwith aluminium composite panel cladding, cleaning and protection of the curtain wallwith aluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminiumitem.s The Contractor shall provide curtain wall with aluminium composite panelcladding, having all the performance characteristics all complete , as per theArchitectural drawings, as per item description, as specified, as per the approved shopdrawings and as directed by the Engineer-in-Charge. However, for the purpose ofpayment, only the actual area on the external face of the curtain wall with AluminumComposite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 33 | 50.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 34 | 13.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer\"s specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work |
| 35 | 16.68Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratorycompaction, of approved size, design & shape, laid in required colour and patternover and including 50 mm thick compacted bed of coarse sand, filling the joints withfine sand etc. all complete as per the direction of Engineer-in-charge. |
| 36 | 16.69Providing and laying at or near ground level factory made kerb stone of M-25 gradecement concrete in position to the required line, level and curvature jointed withcement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with orwithout grooves ( thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as perdirection of Engineer-in-charge ( length of finished kerb edging shall be measured forpayment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 37 | 11.46.2Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 38 | 8.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 39 | 11.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 40 | 7.2.1Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 41 | 9.121Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. |
| 42 | 9.122.2Providing and fixing to existing door frames.30 mm thick Fiberglass ReinforcedPlastic (F.R.P) flush door shutter in different plain and wood finish made with fireretardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate allaround, with suitable wooden blocks inside at required places for fixing of fittingsand polyurethane foam (PUF) / Polystyrene foam to be used all filler materialthroughout the hollow panel, casted monoolithically with testing parameters of F.R.P.laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineerin-charge. |
| 43 | 9.147B.1Providing and fixing factory made uPVC white colour fixed glazed windows/Fixedwindow / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mmboth having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriatedimension. (Area upto 0.75 sqm.) |
| 44 | 9.71.1Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight)with stainless steel screws etc. complete:125x64x2.50 mm |
| 45 | 9.71.3Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight)with stainless steel screws etc. complete:75x50x2.50 mm |
| 46 | 9.74.3Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete:150x10 mm |
| 47 | 9.74.4Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete:100x10 mm |
| 48 | 9.81.1Providing and fixing bright finished brass handles with screws etc. complete:125 mm |
| 49 | 9.83Providing and fixing aluminium die cast body tubular type universal hydraulic doorcloser (having brand logo with ISI, IS : 3564, embossed on the body, door weightupto 35 kg and door width upto 700 mm), with necessary accessories and screws etc.complete. |
| 50 | 21.1.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness ofpolyester powder coating 50 micron ) |
| 51 | 8.2.2.1Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Granite of any colour and shadeArea of slab upto 0.50 sqm |
| 52 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 53 | 12.41.2Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mmdiameter |
| 54 | 11.20.1Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement |
| 55 | 26.30.1Drilling suitable holes in reinforced or plain cement concrete with power drivendrill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels,columns and slabs to introduce steel bars for sunshades/balconies includingfixing the steel bars in position using epoxy resin anchor grout of approvedmake but excluding the cost of reinforcement, all complete as per direction ofEngineer-In-Charge.Upto and including 12mm dia. |
| 56 | 13.47.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additivesof required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over andincluding priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 57 | OD198144/2025-2026Providing and fixing good quality Childrens play item Royal combination set Threein one- CS 04 , including cost of foundation, all materials, labour, conveying,unloading etc all complete as per the Direction of Engineer in charge |
| 58 | OD198145/2025-2026Providing and fixing good quality Childrens play item combination set Four in one-CS 08 , including cost of foundation, all materials, labour, conveying, unloading etcall complete as per the Dierection of Engineer in charge |
| 59 | OD198146/2025-2026Supplying and fixing Cast iron Sitting Bench Garden Bench cast iron legs fitted withFRP Tube strip 4.5’ long having width 85 mm X 30 mm (very strongly moulded) andfitted with black end caps on both sides on the strips with necessary carriage bolts andnut.Using Epoxy Primer coat and Epoxy paint. Including Cost ofMaterial,Labour,Conveyance etc complete as per the direction of Engineer at siteEngineer in-charge |
| 60 | Plumbing and Sanitary Works |
| 61 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 62 | 51.19.ST4Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparationof bed shall be paid separately) 4. 35 to 50 flush capacity |
| 63 | 17.2.1Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid |
| 64 | 17.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers |
| 65 | 17.4.1Providing and fixing white vitreous china flat back or wall corner type lipped fronturinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively withautomatic flushing cistern with standard flush pipe and C.P. brass spreaders withbrass unions and G.I. clamps complete, including painting of fittings and brackets,cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 66 | 17.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi rigid pipe40 mm dia |
| 67 | 17.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete. |
| 68 | 17.9.1Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubberplug, 40 mm C.P brass waste complete, including painting the fittings and brackets,cutting and making good the walls wherever required:White glazed fire clay kitchensink of size 600x450x250 mm |
| 69 | 17.71Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials withsnap fittings of approved quality and colour, weighing not less than 105 gms |
| 70 | 17.73.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms |
| 71 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge. |
| 72 | 50.18.7.2.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer -in-Charge 20 mmdia 10 Kgf/cm2- Internal work - Exposed on wall |
| 73 | 50.18.7.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 25 mmdia 10Kgf/ cm2- Internal work- Exposed on wall |
| 74 | 50.18.7.6.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10 Kfg/cm - Internal work- Exposed on wall |
| 75 | 50.18.8.7.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed workincluding cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 |
| 76 | 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 77 | 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 78 | 50.18.9.21.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 79 | 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 80 | 50.18.9.22.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee |
| 81 | 18.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 82 | 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 83 | 18.58.2.1Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating |
| 84 | 8.10.2Providing and fixing stone slab with table rubbed, edges rounded and polished, of size75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase ofappropriate width with chase cutter and embedding the stone in the chase with epoxygrout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 6 mm nominal size) as per direction of Engineer-in Charge and finishedsmooth.Granite Stone of approved shade |
| 85 | Electrical Works |
| 86 | 14.2Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out theexcavated soil and disposal of surplus excavated soil as directed within a lead of 50metres. |
| 87 | 14.3Filling available excavated earth (excluding rock) in trenches, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer byramming and watering, lead up to 50 metres. |
| 88 | 7.2.3Laying of one number additional PVC insulated and PVC sheathed / XLPE powercable of 1.1 KVgrade of following size direct in ground in the same trench in one tier horizontalformationincluding excavation, sand cushioning, protective covering and refilling the trench etcasrequired.Above 95 sq. mm and upto 185 sq. mm |
| 89 | 12.2Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8metres long stay rod, anchor plate of size 45cm X 45cm X 7.5mm, thimble, stay clamps, turn buckle (20 mm X 60 cm), 7/3.15 mm dia G.I stay wire and straininsulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40 mm nominal size) foundation including excavation and refilling etc. asrequired |
| 90 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 91 | 1.55.2Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group B |
| 92 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet |
| 93 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 94 | 3.7.13.7 Supplying, installing, testing and commissioning of following capacity TPN tapoff box / plug-inbox made of 1.6mm thick sheet steel enclosure duly painted with powder coating onexistingoverhead bus bar system complete with TPN disconnector FSU and HRC fuses,connections, earthing etc. as required.32 amps |
| 95 | 3.8.1Supplying, installing on wall, testing and commissioning of following capacity AirInsulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50HzA.C. supply with enclosure having IP-54 rating after fixing the tap off boxes andall accessories, made of 1.6mm thick steel sheet duly powder coated inconvenient sections complete with 4 Nos aluminium bus bars having currentdensity of 130 A/ sq cm at nominal current rating, necessary joints & expansionjoints, fire barrier at each floor, provision of tapping at every meter, continuousearthing with 2 Nos aluminium strip of suitable size (one on each side) including,G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.200 amps 15 KA SC for 1 sec |
| 96 | 11.1.1Erection of RCC/ PCC pole of following length in brick ballast and ramming thefoundation,finishing with 150mm thick cement concrete (1:3:6) layer on top with includingexcavation and refilling etc as required.Above 4.5 metre and upto 6.5 metre |
| 97 | 90.3.23.5.4Surface mounting decorative fluorescent tube light fitting complete with lamp withcomplete accessories duly wired up for use on 230 V AC .Surface mounting LED40W LED Batten with out put 4000 lumen for use on 250V AC supply |
| 98 | OD197813/2025-2026Supplying and fixing Bollard Light, 10W LED, IP65 etc all complete as per thedirection of Engineer in Charge |
| 99 | OD197814/2025-2026Supplying and fixing RGB Spike Light, 5W, IP66 with DMX Controller etc allcomplete as per the direction of Engineer in Charge |
| 100 | OD197815/2025-2026Supplying and fixing Wall Spot/Projection Light, 30W LED etc all complete as perthe direction of Engineer in Charge |
| 101 | OD198109/2025-2026Supplying and fixing Decorative Entrance Gate Wall Light, 20W LED etc allcomplete as per the direction of Engineer in Charge |
| 102 | OD198175/2025-2026Supplying and fixing GOBO Projection Light for Park Name, 50W etc all completeas per the direction of Engineer in Charge |
| 103 | OD198128/2025-2026Supplying and fixing Outdoor IP CCTV Camera 4MP incl. Wall Mount, PVCConduit, Data Cable & Accessories etc all complete as per the direction of Engineerin Charge |
| 104 | 1.3.3Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with modular switch, modular plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc asrequired.Group C |
| 105 | 2.2.2Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.125 Amp,16 KA,TPMCCB |
| 106 | 3.2.5Supplying, installing, testing and commissioning of following capacity TPN tap offbox made of1.6mm thick sheet steel enclosure duly painted with powder coating on existing risingmainscomplete with TPN disconnector FSU and HRC fuses, connections, earthing etc. asrequired.200 amps TPN |
| 107 | 3.3.10Supplying, installing, testing and commissioning of following capacity TPNdistribution tap off boxmade of 1.6mm thick sheet steel enclosure duly painted with powder coating onexisting rising mains complete with HRC fuses, interconnections, earthing etc. asrequired.63 amps TPN, 4 way |
| 108 | 90.12.1.43Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).4 core 35 sq mm |
| 109 | 9.1.12Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 X 70 sq. mm (35mm) |
| 110 | 9.1.8Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.3 X 16 sq. mm (25mm) |
| 111 | 2.12.2Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 112 | 2.21Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mildsteel, at least 2 mm thick, and vitreous enameled white on both sides, and withinscription in single red colour on front side as required. |
| 113 | 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 114 | 90.3.20.4Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections asrequired.1200 mm 2X20W LED Lamp with box type fixture |
| 115 | 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 116 | 12.34Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class)bracket for mounting of fluorescent / HPMV / HPSV street light fitting on poleincluding bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat ironclamps with nuts, bolts and washer, painting the flat iron with primer and finish paintetc. as required. |
| 117 | 15.4.2Supplying, installation, testing and commissioning of Astronomical time switchcapable of following output in feeder pillars/ Lighting DBs for automatic switchingOn &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24hour display format with suitable battery and indication for relay status i/cprogramming at site complete ad required2 output per phase and suitable for singlephase supply. |
| 118 | 7.1.2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade offollowing size direct in ground including excavation, sand cushioning, protectivecovering andrefilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm |
| 119 | 90.12.1.42Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).4 core 25 sq mm |
| 120 | 1.36Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thicksteel conduit, aluminium cast back plate and brass holder complete, including wiringthe down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single corecable and painting etc. as required. |
| 121 | 90.3.23.5.3Surface mounting decorative fluorescent tube light fitting complete with lamp withcomplete accessories duly wired up for use on 230 V AC .Surface mounting LED20W LED Batten with out put 2000 lumen for use on 250V AC supply. |
| 122 | EXCLUSIVE OF GST |
| 123 | Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL |
| 124 | 2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items |
| 125 | 3.Rate should be Exclusive of GST. |
| 126 | 4.Work should be executed as per DSR/PWD specification and direction of Engineer at site. |
| 127 | 5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. |
| 128 | 6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference. |
| 129 | 7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference |
| 130 | 8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.) |
| 131 | 9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered) |
| 132 | 10.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS. |
| 133 | 11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately. |
| 134 | Make of Electrical equipments/materials |
| 135 | All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification |
| 136 | Panel Boards: CPRI certified reputed manufacturers make |
| 137 | MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent |
| 138 | Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD |
| 139 | Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent |
| 140 | Cable Glands & Sockets - REPUTED MAKE , Cosmos |
| 141 | Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent |
| 142 | Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj |
| 143 | 12. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference. |
| 144 | 13.VITRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client |
| 145 | 14.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client |
| 146 | 15.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO |
| 147 | 16. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |