| Sl. No. | Item Description |
| 1 | BR PORTION:-Taking down chowkats or frames n exc 1.50 Sqmwith shutters (without taking off shutters from the frame) complete all as specified & directed. |
| 2 | Taking down chowkhats or frames with shutters exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutters from frame) complete all as specified & directed. |
| 3 | Factory made Pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fastscomplete all as specified & directed. |
| 4 | Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fastscomplete all as specified & directed. |
| 5 | 35mm thick 2nd class hardwood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered paticle board medium density, wood patilcle board with commercial face veneers complete all as specified and directed. |
| 6 | 35mm thick 2nd class hard woodglazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated shash bars, any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters , supplied & fitted to chowkats as specified and directed. |
| 7 | Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed. |
| 8 | Preparation of old painted steel surfaces/CGI/PGI sheets andapplying one coat of synthetic enamel paint, complete all as specified and directed. |
| 9 | Preparation of new or previously untreated surfaces of wood over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 10 | Factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet, reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified. |
| 11 | Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site all as specified and directed. Note:-Cadmium screws to be used for fixing and fixtures. |
| 12 | 4mm thick Sheet glass of ordinary quality,glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed. |
| 13 | 3mm thick Frosted Sheet glass of ordinary quality,glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed. |
| 14 | Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples as specified and directed. |
| 15 | Mild steel butt hinges, medium weight, cold rolled,100mm long, complete all as specified and directed. |
| 16 | Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed. |
| 17 | 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 18 | 150 mm longAluminium anodised handles of extruded section and fixed, complete all as specified and directed |
| 19 | 300mm Mild steel ordinary rat tail rod pattern springs including roller and roller platecomplete all as specified and directed. |
| 20 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed. |
| 21 | Steel water tubing 20mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified and directed. |
| 22 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed. |
| 23 | Steel water tubing 15mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified and directed. |
| 24 | 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed in repair complete all as specified and directed. |
| 25 | Supply and fixing in repair Bib taps 15mm bore of cast copper alloy chromium plated , screwed down, high presure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule, fixed, complete all as specified and directed. |
| 26 | 15mm bore Stop valve cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified and directed. |
| 27 | 15mm bore Stop valve cast copper alloy chromium plated fancy type with long shank and cup (concealed type) screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified and directed. |
| 28 | Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed |
| 29 | PVC valve less symphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets and connections to pipes and fixing of chain and pull, or lever and 32mm dia PVC. flush pipe for low level cistern including all joints fixed, complete all as specified and directed. |
| 30 | 600mm x 450mm size bevelled edge mirror with border, selected quality 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-Charge. |
| 31 | Vitreous china bowl urinal flat back small- normal, size of 465X355X265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws and pointing around urinal back in cement etc and 32mm dia PVC waste pipe fixed in repair, complete all as specified and directed. |
| 32 | Vitreous china squatting pan (Orissa pattern) size 580 x 440 mm, snow white, with \"P\" or \"s\" trap, front or back inlet and integral foot rests, complete connection to drain (outgoing pipe) and to flushing pipe and syphonage pipe etc. fixed in repairs including lime concrete bedding, complete, all as specified and directed. |
| 33 | PVC connection 15mm size with length 600mm fixed in repair, complete all as specified and directed. |
| 34 | PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floor/walls as soil pipe(vent pipe)/weep holes, fixed in repair complete all as specified and directed. |
| 35 | PVC (SWR) bends any radius 110mm bore fixed in repair with access doorcomplete all as specified and directed. |
| 36 | PVC (SWR) branch piece, douuble (double Y) equal or unequal 110mm bore fixed in repair , complete all as specified and directed. |
| 37 | PVC (SWR) floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repair, complete all as specified. |
| 38 | PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint, laid in trenches/floors as soil pipe, fixed in repair, complete all as specified and directed. |
| 39 | PVC (SWR) bends any radius 75mm bore fixed in repair with access doorcomplete all as specified and directed. |
| 40 | PVC (SWR) vent cowl for 75mm dia fixed in repair, complete all as specified and directed. |
| 41 | Rotational moulded polyethylene water storage tankstriple layer (Cylindrical vertical with closed top), ISI marked hoisted and fixed in position all as spd in SSR Pt-I,of capacity1000 Ltrs including making necessary connection and fittings, complete all as specified and as directed. |
| 42 | Ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule, 20mm bore fixed, complete all as specified and directed. |
| 43 | Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 44 | Glazed ceramic coloured tiles 450x350x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge. |
| 45 | Non skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles,fixed over and including 15mm thickscreed bed in CM (1:6), complete all as specified and directed. |
| 46 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 47 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed |
| 48 | Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick walls built in in CM 1:4 all as specified and directed |
| 49 | Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key, scrubbing down with water etc.complete all as specified. |
| 50 | 15mm thick cement plaster rendering in CM 1:4 on other than fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, including mixing of WPC as per manufacturer\"s instructions complete all as specified and directed. Note :- Supply only WPC shall be measured and paid for separatly. |
| 51 | 5mm thick cement plaster rendering in CM 1:3 on fair faces of concrete surfaces & finishing the surface even and smoothin ceiling without using extra cement,complete all as specified and directed. |
| 52 | 10mm thick cement plaster rendering in CM 1:6 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed. |
| 53 | Applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed. |
| 54 | Preparation of old wall surfaces and applying one coat of cement base paint complete all as specified and as directed. |
| 55 | Preparation of newlyplastered surface of wall including cornices pilaster etc, and applying two coats of oil emulsion distemper over and includinga coat of 1-2 mm thick wall care putty, complete as specified and directed. |
| 56 | Complete removal of existing treatment on the walls of any description and applying two coats of distemper oil emulsion complete all as specified and as directed. |
| 57 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for and removing the debris materials from site to a distance not exc 50m complete all as specified and as directed. |
| 58 | 10mm thick cement plaster rendering in CM 1:3 on sunkun/roof slab, finishing the surface even and smooth without using extra cement including mixing of WPC as per manufacturer\"s instructions, complete all as specified and directed. Note :- Supply only WPC shall be measured and paid for separatly. |
| 59 | Machine cut kota stone slab flooring 20-25mm thick with & including white marble border of 150mm wide, 16-20mm thick laid over & including 20mm thick screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 60 | Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurryin floors and pointed with equal proportion of white and grey cement and no pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed |
| 61 | 75 mm thick PCC 1:4:8 type D-2 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified directed. |
| 62 | 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified directed. |
| 63 | Taking down existing roof treatment of any description in any condition including removing of cement plaster of concrete of any description from the roof surfaces and removing all the debris to a distance n.exc 100m and roughening surfaces by sweeping clean and washing down with water to remove dust etc and applying evenly cement slurry at the rate of 3 Kg/Sqm over cleaned surfaces and providing 10 mm thick cement screed in CM 1:4 mixed with liquid water proofing compound Pedilite LW plus @ 200 ml per 50 Kg of cement finished surface even and smooth for laying of water proofing membrane (Note : WPC will measured and paid separately as supply only), after that cleaning the entire roof surface thoroughly to remove all loose particles, dust/dirt particles and applying with onecoat of industrial bituminious primer at the rate of 0.40 lit/Sqm over the plastered surfaces of roof and applying a course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C@ 1.2 kg/sqm then applying APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap primed surfaces by forced (tourch) application as per manufactures instructions and applyinga coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C@ 1.2 kg/sqm blinded with fine sand@ 0.5Kg/Sqm over APP membrane , complete all as specified and directed. |
| 64 | Precast cement concrete (1:2:4) ,type B-1 using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 65 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed. |
| 66 | 50mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed. |
| 67 | 20mm thick granite (of approved type colour) work (table rubbed & polished) in jambs, pillars, window cills, cooking plateform laid over and including 15mm thick cement screed (1:4) and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the colour of granite stone including cutting and and moulding the edges, complete all as specified and directed. |
| 68 | Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed. |
| 69 | Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by E-in-C |
| 70 | Supply and fix in repairs 15mm bore pillar tap cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered \"Hot\" or \"Cold\" with long shank and fly nuts screwed for iron pipe or for brass ferrule complete, all as specified & directed. |
| 71 | Supply and fixing in repair Vitreous china Wash hand basin, white, flat back of size 580x450mm including brackets, brass chromium plated waste coupling, and waste pipe PVC 32mm dia including cutting for and pinning in ends of brackets or erecting stand etc fixed in repair, complete all as specified. |
| 72 | Supply and fixing in repair MS powder coated tubular curtain rod fancy type of 25mm dia fixed in repairs, complete all as specified and directed. |
| 73 | Supply and fixing in repair Tubular towel rail 60mm long 20mm dia, D type brass chromium plated incl necessary brackets, fixed in repairs, complete all as specified and directed. |
| 74 | Supply only liquid water proofing admixture. complete all as specified and as directed. |
| 75 | MS powder colour coated, decorative type knobs with bracket of fixing at end of pelmet rod suitable for 25 mm dia, compelte all as specified and directed. |
| 76 | E/M PORTION:-Taking down carefully copper/aluminium point wiring for light, bell socket power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket,ceiling rose, celing fan etc complete all as specified and directed. |
| 77 | Point wiring with two single core 1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of approporiate size and all requisite accessories such as PVC elbow, Tee, collars, bends etc with PVC terminals box& cover for mounting switches, sockets, fan regulator etc complete all as specified and as directed for the following:- |
| 78 | One light/fan point controlled by one switch complete all as specified and as directed. |
| 79 | One 5 pin, 6 A socket outlet on the same board complete all as specified and as directed. |
| 80 | One 5 pin, 6 A socket outlet on the independent board complete all as specified and as directed. |
| 81 | All as per item No. 77 above but with two 2.5 sqmm size cable as phase and neutral and one 2.5 sqmm size cable as earth continuity for 15/20 amp multipurpose socket outlet on independent board complete all as specified and directed. |
| 82 | Ceiling rose, 3 phase,bakelite 65x50mm two or three therminals complete all as specified and directed. |
| 83 | Piano Type switch , 1 way, 6 amp, complete all as specified and directed. |
| 84 | Socket outlet 2 in 1, 3 pin 6 Amps, flush type complete all as specified and directed. |
| 85 | Switch socket combination 2 in 1 , 5 pin 6 Amp, flush typecomplete all as specified and directed. |
| 86 | Switch socket combination 2 in 1 , 3 pin 6and 16 Amp, flush type universal complete all as specified and directed. |
| 87 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit notless than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft / loose soil, P.C.C 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer,charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed. |
| 88 | Supply laying jointing and testing XLPE and PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core complete all as specified and directed. |
| 89 | Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed. |
| 90 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Starrated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. |
| 91 | Supply and fixing in replacement Sub main wiring with single core cable 2 x 6 sqmm FRLSinsulated unsheathed stranded copper conductor cable 1100 Volts grade idrawn through PVC casing/caping 25 mm dia ISI marked fixed on wall/ceiling,alongwith 1x4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly , complete all as specified and directed.Note:-Two runs of6sqmm cable alongwith one run of 4sqmm PVC insulated copper conductor as earh wire inclcasing caping shall be measured as one unit. |
| 92 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole240V , 20 Amp MCB, complete all as specified and directed. |
| 93 | Exhaust fan, steel body AC single Phase 230V of size 300msweep with, blades, and frame and louvers, complete all as specified and directed. |
| 94 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete all as specified and directed. |
| 95 | GI pipe street bracket light grade 40mm bore 1.5mtr long bent to shape as directed with two number of flat iron clamps made out of mild steel flat iron 50x6mm with 16mm dia bolts with nuts and washers fixed on steel pole / PCC pole duly painted with two coats of aluminium paints with & including taking down old unsv bracket any type, complete all as specified and directed. |
| 96 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 4 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 97 | Supply and Fixing in repair MCBs, SPN, 240 volts, breaking capacity 10 KA, \"C\" series, rating 40-63 amps,complete all as specified and as directed. |
| 98 | Supply and Fixing in repair MCB, SP,240 volts, breaking capacity 10 KA, \"C\" series, rating 6 to 32 amps, complete all as specified and as directed. |
| 99 | LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 100 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 101 | Invert Led Lamp , CDL 10 Watt , B22 base all as specified and as directed. |
| 102 | GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc complete all as specified and directed. |
| 103 | Factory made PVC pole mouted street light junction box, three phase and neutral, 415 volts, weather proof of size 155x100x60 mm deptg, accomodated with properly insulated 04 nos of aluminium bushbar of 40 Amps rated current cap, 02Nos of insulators per each each busbar, nut bolts and clamps 25x3 for fixing of junction box etc. and including MCB SPN 6 Amps-01 Nos, for connecting of securtiy light fittings, with hinged door and locking bolt complte all as directed. Make: Sintex ,Model No : GSJB-3726 or equivalent as given in PS. |
| 104 | Insulated PVC sheathed multi core flexible cable copper conductor 1100 volts grade conforming to IS-694/2010 of size 1.5 sqmm 3 core incl 25mm PVC conduit from junction box to light fittings connecting up complete all as specified and directed by EIC. |
| 105 | Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 106 | Supply laying jointing and testing XLPE and PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 core complete all as specified and directed. |
| 107 | Excavation in trenches not exc. 1.5 m wide andexc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed. |
| 108 | Returning, filling in including spreading, leveling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site. |
| 109 | Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed. |
| 110 | Supply and fixing DWC HDPE pipe for protection of power cable (orange in colour) of size 50 mm dia complete with fittings and including cutting, jointing and clamping all as specified and directed. |
| 111 | Supply and fixing in repairs GI pipelight grade 50 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc complete all as specified and directed. |
| 112 | 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed inservice connections suspended by insulating hangers notmore than 1 metre apartincluding4mm suspension wire, one twin core cable flat or circular of area 10 sqmm 2 core incl taking down old u/s cable,complete all as specified and directed. |
| 113 | Steel water tubing 25mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified and directed. |
| 114 | Steel water tubing 40mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified and directed. |
| 115 | 25mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed in repair complete all as specified and directed |
| 116 | 40mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed in repair complete all as specified and directed. |
| 117 | Cutting through existing bituminous road/PCC/floor/approx width 15cmx60cm depth along cross section of the road for laying of GI tubing/RCC pipe and reparing the road to match with the original finish complete all as specified and direcred. |
| 118 | Supply, connecting, testing and commissioning Pressure booster pump of capacity1.0HP, single phase, 230V, 2900 RPM , ISI marked withbrass immpeler complete all as specified and directed. |
| 119 | Drilling/tapping the existing DI/CI pipe line for fixing tee/bend etc of pipe 50/80 mm bore complete all as specified and directed. |
| 120 | Supply and fix Servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, outdoor type with IP-65 protection & designed for input variation between 190 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 Volts per second per phase of capacity 30 KVA complete including provision of plateform of suitable size for the same as per manufacturer reccomendation complete all as specified & directed.Note:- 1.Make approval and drawings shall be submitted for approval by GE. 2. The equipment shall be tested at the manufacturers factory before dispatch and the contractor shall make all necessary arrangements for the same. |
| 121 | Supply laying jointing and testing XLPE and PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core complete all as specified and directed. |
| 122 | Dry Sand cushioning to cables 8cm thick before laying cable and 15 cm thick after laying and testing of cable complete all as specified and directed. Note:- Punned thickness shall be measured and paid. |
| 123 | Supply and laying sub class \"B\" bricks laid dry flat transversely along the length of cable with widht equal to the length of bricks over sand cushioning as protection cover of cablescomplete all as specified and directed. |
| 124 | Making bore to road/cement path/hard standing/road for providing GI pipe 40mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed. |
| 125 | Bus bar chamber out door type made out of 40x40x6mm angle iron frame and 15 gauge MS Sheet of size 600x400x200mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer having copper bus bars size 40x6mm duly mounted on insulators and making connections of incoming and out going cable with appropriate type of aluminium thimbles and making PCC (1:2:4 type C1 using 20mm graded stone aggregate) plateform to rest/fix the feeder pillar, complete all as specified and directed. |
| 126 | Earthing complete with galvanized steel earth plate electrode 600x 600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron earth lead strip 32x6mm by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 40mm bore including GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including taking down old unsv earthing, complete all as specified and directed. |
| 127 | Supply and fix Servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, outdoor type with IP-65 protection & designed for input variation between 190 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 Volts per second per phase of capacity 160 KVA complete including provision of plateform of suitable size for the same as per manufacturer reccomendation complete all as specified & directed. Note:- 1.Make approval and drawings shall be submitted for approval by GE.2. The equipment shall be tested at the manufacturers factory before dispatch and the contractor shall make all necessary arrangements for the same. |
| 128 | Supply laying jointing and testing XLPE and PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm 3.5 core complete all as specified and directed. |
| 129 | Sub main wiring with single core cable 2 x 4 sq mm FRLSinsulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing capingmedium grade alongwith 1x 2.5 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed.Note:-2 wire of 4sqmm, 1 wire of 2.5 sqmm and one run of pvc casing caping shall be measured as one unit. |
| 130 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 131 | Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 11000 volts grade, cross sectional area 25 sqmm ,3.5 core complete all as specified and directed. |
| 132 | Double break in sheetsteel enclosure combination fuse switch 63 Amp confirming to IS/IEC 13947 , 3 rated voltage 415V AC 50Hz type TPN complete all as specified and as directed. |
| 133 | Rigid non-metallic PVC conduit 25 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts,saddles, pipe hooks etc. complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy