| 1 | Excavating over areas, n exc 1.5 m deep and getting out in soft/soft soil etc complete all as specified and directed. |
| 2 | Rolling and consolidating formationsurfaces in cutting with 8 to 12 tonne power roller complete all as specified and directed. |
| 3 | M&L 150mm thickHard core of gauge n exc 63mm,of broken stone aggregate deposited, spread and levelled in layers n exc 15cm thick (in tranches and surface), watered and rammed and compected with 8 to 10 tonns power roller complete all as specified and directed. |
| 4 | M&L forPCC 1:4:8 type D2 (40 mm graded aggregate) insubbaselaid over hardcore complete all as specified and directed. |
| 5 | M&L for Providing and laying 80mm thick factory made chamfered edge cement oncretepaver block of M-30 grade with approvedcolour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 6 | M&L for Providing and laying 60mm thick factory made chamfered edge cement oncretepaver block of M-30 grade with approvedcolour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 7 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, ointed with cement mortar 1:3 (1 cement: 3 coarse sand), ncluding making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), includingmaking drainage opening wherever equired complete all as specified and directed. |
| 8 | M&L for applying two coats of synthetc enamal paint after preperation of new surface complete all as specified and directed. |
| 9 | M&Lof cement concrete type B1 1:2:4 (40 mm graded aggregate) as PCC at any place or coping complete all as specified and directed. |
| 10 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in soft/loose soil complete all as specified and directed. |
| 11 | M&L Hard core of gauge n exc 63mm, deposited, spread and levelled in layers n exc 10cm thick (in tranches and surface), watered and rammed to a true surface with broken stone or boulders complete all as specified and directed. |
| 12 | M&L for PCC 1:4:8 type D2 (40 mm graded aggregate ) in foundations, filling and mass concrete complete complete all as specified and directed. |
| 13 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed. |
| 15 | M&L RCC ofNominalMix of 1:1.5:3 as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concretecomplete all as specified and directed. |
| 16 | M&L RCC ofNominalMix of 1:1.5:3 as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 17 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 18 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 19 | M&L Rendering 10 mm thick on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement on walls in CM 1:6 complete all as specified and directed. |
| 20 | M&L two coat of cement base paint on walls including preperation of newly untreated surface with a coat of cement wash with portland cement complete all as specified and directed. |
| 21 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 22 | S&F TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, or bars for slab also, spacers and binders binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 24 | M & L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W(gde-E-250) quality B complete all as specified and directed. |
| 25 | S&Fbase plates (plain or chequered) channels,lug angle,square cut or notched (ordinary and counter sunk) forming holes, without any attachmentincluding welding etc, Fe-410-W(gde-E-250) quality B complete all as specified and directed. |
| 26 | S&F mild steelscrew bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but nexc 10cm long and diameter of neck in mm 11 to 15 complete all as specified and directed. |
| 27 | M & L Painting steel surface of any description over 10 cm width and girth including preparation, primer with red oxide and two coats of synthetic enamel paints complete all as specified and directed. |
| 28 | M&L for Brickwork built with flyash brickin CM 1:6 with subclass `B\" bricks, straight or curved on plan exc 6m mean radius complete all as specified and directed. |
| 29 | S & F Stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed in steel windows and wooden shutters complete all as specified and directed. |
| 30 | Supply and fixing 3 mm thick tinted sheet glass ordinary quality and glazing with oil putty in square n exc 0.5sqm in each pane complete all as specified and directed. |
| 31 | M&L for Preparing newwooden/steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 32 | Dismantling asbestos cement corrugated or semi corrugated sheets as in roof covering complete all as specified and directed. |
| 33 | M&L Pre painted galvalume alumimnium zinc coating GI based Plain steel sheet 0.50 mm th, sheeting of any colour having tensile strength of 550 mpa as in ridges etc complete all as specified and directed. |
| 34 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 35 | S&F Anodised aluminium snap grid framed work for false ceiling and incl hangers 6mm dia G.I (upto 1200mm long ) adjusting level fixed to roof slabs/purlin/rafter with the help of cleats made out of G.I flat 40x3mm size 60mm long and expansion holdfastener 12.5mm dia 40mm long complete all as specified and directed. |
| 36 | S&F False ceiling with calcium Silicate board, perforated type, and acoustic purpose, factory made matt finish surface, 600mm x 600mm in size and 12mm thick complete all as specified and directed. |
| 37 | S&F hollow PVC wall paneling, super strong quality single side prelaminated with flat or fancy patterned on laminated side, incl PVC \"L\" and \"U\" sections for finishing of corners and ends etc inclusive of fixing with screw or with solvent cement requrired at site on walls complete all as specified and directed. |
| 38 | Dismantling floor hearth or wall tiling including cement mortar bedding complete all as specified and directed. |
| 39 | M&L glazed ceramic coloured tiles, (350x450)x7mm / (350x250)x7mm thick as in vertical surfaces like dado or skirting over 10mm thick in CM 1:3 set & joined in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 40 | M&L Virified Ceramic tiles 10 mm thick (square/ectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. over and incl 15 mm thick screed in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 41 | M&L non skid ceramictiles 7 to 8 mm thick coloured/white shade (Square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors over and including provision of cement screed bedding layer 15 mm thick in CM 1:6 etc set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 42 | M&L for colour Chequered cement concrete tiles with grey cement and pigments (PU moulded) 300mm x 300mm x 25mm thick, set in CM of (1:6), jointed and pointed in neat cement slurry in floors/paths complete all as specified and directed. |
| 43 | M&L 75mm thickCement concrete type D- 2,1:4:8 (40mm graded aggregate)as in sub base complete all as specified and directed. |
| 44 | M&L for 1:3:6 (20mm aggregater) for coping and side filling and other PCC work , complete all as specified and directed. |
| 45 | M & L for 50mm thick cement concrete type C – 1 (1:3:6) using 20mm graded stone aggregate as in plinth protection etccomplete all as specified and directed. |
| 46 | Dismantling wrought iron or mild steel work of any description not otherwise provided, for MS railing at passage, stair and rear sitouts complete all as specified and directed. |
| 47 | M&L for rolled sections as in tubular trusses / rafter / purlin fixed with angle cleats or other connecting plates, other iron workconfirming to FE-410 (Gde-E-250) complete for holding galvallume sheeting in passage complete all as specified and directed. |
| 48 | S & F in repair fancy type Stainless steel curtain rod 25mm dia includingSS brakcet, knobs, rings stops, rollers etccomplete all as specified and directed. |
| 49 | Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. |
| 50 | M&L for 15 mm thick rendering in CM 1:4 over brick / concrete wall surfaces trowelled to even & smooth without using extra cement for mixed with liquid type water proofing compound as per manufacturers direction on external surfaces complete all as specified and directed. |
| 51 | Supply only liquid type water proofing compound complete all as specified and directed. |
| 52 | M&L Rough cast plaster as specified .(Rendering coat not less than 10mm thick in C:M 1:3 , while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even) on external wall upto cill height complete all as specified and directed. |
| 53 | M&L two coats of Oil bound distemper on new plastered or unplastered surfaces over and including 2 mm thick acrylic wall care (Birla / JK white / Asian / Berger) putty and a coat of alkali resistant primer on walls including preparation of surfaces complete all as specified and directed. |
| 54 | M& L for preparation of newly plastered surfaces of wall and applying two coat of Weather coat paint over one coat of alkali resistentcomplete all as specified and directed. |
| 55 | M& L for preparation of old surfaces of wall and applying one weather coarpaint complete all as specified and directed. |
| 56 | Demolition of stone slabs and paver (interlocking/ Kota stone) tiles of any description or thickness in floors,wallsaprons etc (laid, bedded and pointed in any mortar) complete all as specified and directed. |
| 57 | M&L for Machine cut kota stone slab flooring 20-25mm thickover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including 15mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed. Note : Single piece tiles will be placed on the surface of stair case tread area). |
| 58 | Taking down carefully copper/ Aluminium point wiring ( light, fans, socket, power socket) complete including taking out existing unserviceable terminal boxes and conduit with switches/sockets/fan regulators and fittings such as ceiling roses, pendants, tube lights fittings lamp holders, brackets light fittings, rectangular blocks DB MCCB etc and making good disturbed surface of wall/ floor etcto matchwith the existing the surface etc complete all as specified and directed. |
| 59 | Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic existing concealed conduit 19/20 mm dia medium duty, ISI marked to beterminated & including pressed modular steel boxes & cover plate of module as required on site. Including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistrandedcopper earthcontinuity conductor controlled by one switchand/or one regulator complete including repairing the surfaces in CM 1:3 and finishingthe surface as per existing treatment complete all as specified and directed. |
| 60 | Description all as per item No 59.00 (here-in-before) but One three pin 5 Amp socket outlet point on indep board controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 61 | Description all as per item No 59.00 (here-in-before) butOne three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed. |
| 62 | Description all as per item No 59.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 63 | S&F Modular switch 1 way 6A 1 module Single pole, one way, 230 volts all as specified and directed |
| 64 | S&F Modular switch 1 way 16A 1 module all as specified and directed |
| 65 | S&F Modular socket 6A -2/3 pin combined 2 module type 230 volts AC complete all as specified and directed. |
| 66 | S&F Modular socket 6A/16A -2/3 pin combined 2 module type AC complete all as specified and directed. |
| 67 | S&F Modular lamp holder, insulated body with back plate suitable for batten fittings and complete all as specified and directed. |
| 68 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 69 | S&F Modular ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed. |
| 70 | S&F modularfan step regulator 120W-2 module suitable for 1200/1400 mm sweep ceiling fan etc complete all as specified and directed. |
| 71 | S&F LED light fitting 1x20 watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any crack. The fitting should have following technical specification :-(i) Surge protection of minimum 2m KV (ii) Power factor should be more than 0.90 (iii) Cool white colour, (iv) Lumen output should not be less than 1700 lumens, (vi) can withstand with input voltage range 140-280V AC, (vii) Colour rendering index should not be less than 80, (viii) Corelated colour should be minimum 6000 degree Kelvin (ix) Minimum warranty period of 2 years. |
| 72 | S&F Sheet metal enclosure distribution board SPN, 8 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar complete all as specified and directed. |
| 73 | Supply and fixing MCBs SP6 to 40Amps, B-curve, 240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note:Make of the MCB should be the same as that of DB |
| 74 | Supply and fixing MCBs SPN 40 Amps,240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:Make of the MCB should be the same as that of DB |
| 75 | S&F Sheet metal enclosure distribution board VTPN, 4way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers properwithPCC works complete all as specified and directed. |
| 76 | Supply and fixing MCCBs 63 Amps,415 volts, 16 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note:Make of the MCCB should be the same as that of DB |
| 77 | S & F for Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source not less than 120 lumen/watt and electronic driver of capacity 25/35 watts with pre wired andnecessary mounting arrangements and provision of 1.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including 40 mm dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed. |
| 78 | Taking down old unserviceable service wire 16 sqmm 2 core including fitting & fixtures and making good of the surface to match with the existing complete all as specified and directed. |
| 79 | M&L for service wire 16 sqmm 2 corewith 4mm GI wire fixing properly with necessary conduit complete all as specified and directed. |
| 80 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable for phase, one run of 6 sqmm cable for earthing and one run of PVC conduit will be measured as one unit. |
| 81 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with tip edge of the plate not less than 1.5 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel including15mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate No 3 of SSR Part I including excavation and earthwork in any type of soil/strata and testing on completion complete all as specified and directed.Note :- GI earth wire 4mm dia and 15mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 82 | M&L for providing/cutting the round/ square hole of required size in wall finishing the same for disturbed surfaces complete all as specified and supply and fixing propeller type ac ventilating fans, single phase , 230 volts 250 mm sweep complete and grouting the ragged bolts in wall fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writing MES No. with black synthetic enamel paint 2.0 cm height complete all as specified and directed. |
| 83 | S&F high bay light 80 Watt (or nearest highest cap) suspended or surface type with very high efficiency in PDC housing suitable for the sheds. The luminairies the efficiency 110 lm/w ithingress protection of IP-66 including connecting 3 core copper wire of size 1.5 sqmm complete all as specified and directed. |
| 84 | Supply, laying,jointing, testing and commissioningof size 35 sqmm 3.5 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed.Note : Excavation, earth work, sand cushion & brick protection shall be paid separately. |
| 85 | M&L for bricks covering to under gound electric cable using sub class \"B\" bricks laid dry, flat perpendicular to the directin of the cable complete all as specified and directed. |
| 86 | Supplying, filling in trenches, spreading, leveling sand cushioning 8cm below cable and 15 cm above the cable for under ground cable complete all as specified and directed. |
| 87 | M&L wall mounting industrial fan metal body 750mm sweep, single phase, 230 volts complete and grouting the ragged bolts in wall fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated tyree core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writing MES No. with black synthetic enamel paint 2.0 high complete all as specified and directed. |