Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Part-I (B/R Work) |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed. |
| 3 | M&L for brick work with sub-class `B\" bricks (using old size bricks), straight or curved on plan exceeding 6m mean radius built in CM 1:6, Complete all as specified and directed. |
| 4 | M&L for brick work with sub class \"B\" bricks (using old size bricks) straight or curved on plan to any radius in half brick thick wall radius, built in CM 1:4, complete all as specified and directed. |
| 5 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed. |
| 6 | M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finishing even and smooth without using extra cement, complete all as specified and directed. |
| 7 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finishing even and smooth without using extra cement using integral water proofing compound, complete all as specified and directed. (WPC shall be measured and paid separately). |
| 8 | Supply only integral water proofing compound, complete all as specified and directed. |
| 9 | Preparation of new plastered surfaces o wall and applying two coats of distemper oil emulsion including 3mm thick of wall care putty and priming coat, complete all as specified and directed. |
| 10 | Preparation of newly plastered surfaces of wall sides and soffits of the beams, ceilings, fascia\"s, parapets etc. and applying two coats of weather paint (Apex) over a coat of exterior primer on, colour and tint as directed in any pattern including scaffolding up to 15m height, complete all as specified and directed. |
| 11 | Complete removal of existing treatment of walls and applying 3 mmthick wall care putty and prepare the smooth surface with sand paper and applying two coats of distemper oil emulsion paint, complete all as specified and directed. |
| 12 | Complete removal of existing treatment from the old plastered, pointed/concrete wall surfaces and applying two coat of weather paint (apex) over a coat of exterior primer, complete all as specified and directed. |
| 13 | Preparation of old painted steel & iron surfaces of any description over 10cm width or girth and applying One coat synthetic enamel paint, complete all as specified and directed. |
| 14 | Preparation of old plastered or unplastered ceiling surfaces and applying two coats of white wash, complete all as specified and directed. |
| 15 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) n exc. 1.5 Sqm and credited to the contractor, complete all as specified and directedNote: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. |
| 16 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n exc 4.0 Sqm and credited to the contractor, complete all as specified and directedNote: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. |
| 17 | S&F forpressed steel frame made out of mild steel 1.25mm thick sheet, with size of frame 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. and applying a shop coat of red oxide primer including providing PCC 1:3:6, type C-0 (using 12.5mm graded crushed stone aggregates) as in back filling of pressed steel frame, complete all as specified and directed. |
| 18 | S&F 35mm thick 2nd class softwood plain framed panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board with commercial face veneers, complete all as specified and directed. |
| 19 | S&F 35mm thick 2nd class hardwood, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), complete all as specified and directed. |
| 20 | Preparation of new wood and wood based surfaces of any description exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 21 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and directed. |
| 22 | S&F 150mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 23 | S&F 150mm size Aluminium handles, cast type, anodised, complete all as specified and directed. |
| 24 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying and fixing in opening, complete all as specified and directed. |
| 25 | S&F 30mm thick Factory made Solid Panel PVC Door Shutter (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed. |
| 26 | S&F 125mm size Aluminium handles, cast type, anodised, complete all as specified and directed. |
| 27 | S&F 125mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 28 | S&F 100mm long medium weight, cold rolled mild steel Butt hinges, complete all as specified and directed.. |
| 29 | S&F Box type steel window double frame (glazed & gauged) made of ERW tube P- section of size 60mm x 25mm double rebated outer frame comprise glazed Skelton shutter door frame of ERW tube P-section size 50mm x 20mm with two No\"s openable leaf consisting of two No\"s of sash bar of T-sec 20mm x 3mm welded to frame with one No vertical mullion of ERW of ERW box type T-section size of 60mm x25mm FI 2mm thick welded / screwed to frame for fixing of wire gauge/glass and 10mm Sqr Bar security grill including fixture and fitting like as handle, tower bolt stopper , cleat, pintail hinges, holdfast primer etc., complete all as specified and directed.(Note- sheet glass, wire mess rate shall be includedinthe quoted rateand window will be measured one side only) |
| 30 | S&F aluminium powder coated aluminium window having three track (minimum thickness of powder coating 50 micron) with aluminium section 92mm X 31.75mm (Weight bottom section 1.070 kg/m, top section 0.933 kg/m, shutter section 40mm X 18mm (weight of handle section 0.417 kg/m) interlock 0.547 kg/rm mounted on bearing to slide on tracks plain anodized in approved shade including supply andfixing of 5mm thick plain glass and wire mesh, PVC track gasket, EPDM rubber gasket on glass of weather tightening along with locks, handle including sealing gap with marble surfaces with silicon sealants making it water proof in all manner etc. complete all as specified and directed. |
| 31 | Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 32 | M&L for 25mm thick plain cement concrete, 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub base of floor finish even and rough to receive further floor finishes (tile/kota stone/ marble ), complete all as specified and directed. |
| 33 | M&L for Non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 34 | M&L for Glazed ceramic tile 300x600x06-7mm thick (coloured) on vertical surfaces such as wall, dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 35 | M&L for Light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 36 | M&L for Light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat CM 1:4, complete all as specified and directed. |
| 37 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work for fair finished surface, exceeding 200m thick (Horizontal or sloping), complete all as specified and directed. |
| 38 | M&L for Reinforced cement concrete, 1:2:4, Type B-1 (using 20 mm graded crushed stone aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 39 | M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 40 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed. |
| 41 | S&F snap grid for false ceiling of size 600mm x 600mm grid exposed grid system fabricated with galvanised iron powder coated section all as shown on serial page No 185 of SSR part II (2020 print) including 12mm thick designer particle boards or tiles for insulation and acoustic purposes, 60cm x 60cm in size, including painting of matching colour of existing surface, complete all as specified and directed. |
| 42 | S&F 20mm dia stainless steel drapery curtain rods including brackets, end finials (Latoo), for curtain rails fancy decorative type and fix with brass screws to walls approved quality etc., complete all as specified and directed. |
| 43 | Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 44 | S&F for 15mm bore tubes, medium grade, galvanised, with all fitting, ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc.) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified and directed. |
| 45 | Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 46 | S&F for 20mm bore tubes, medium grade, galvanised, with all fitting, ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc.) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified and directed. |
| 47 | M&L for Lagging to 20mm bore pipes used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh including applying with brushing neat cement slurry with 3 kg of cement per Sqm complete, complete all as specified and directed. |
| 48 | S&F in repairs vitreous china squatting pan, Orissa pattern, size 580 x 440mm and making good, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc., including trap set in and including concrete, complete all as specified and directed. |
| 49 | S&F in repairs 10 litre capacity PVC valveless, Syphonic action type, flushing cistern low level, white with inlet ball valve, float and handle including brackets and PVC flush pipe etc., complete all as specified and directed. |
| 50 | S&F in repair vitreous China urinal, half stall type including all fittingswith grating and union for discharge pipecomplete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified and directed. |
| 51 | S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms), complete all as specified and directed. |
| 52 | S&F in repairs 15mm bore bib tap, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 53 | S&F in repairs 15mm bore stop valve, cast copper alloy, chromium plated, fancy type, long body with crutch or butterfly handle, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 54 | S&F in repairs vitreous china wash hand basin, white flat back, size of 550x400mm including cutting for and pinning in ends of brackets (including supply and fixing of brackets) or erecting stand, 32mm brass chromium plated waste fitting with long screwed shank and fly nut flangedend bedded in red led cement, chain and plug and porcelain stopper, complete all as specified and directed. |
| 55 | S&F in repairs 15 mm bore wall mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed. |
| 56 | S&F in repairs 125mm shower rose cast copper alloy, chromium plated with swivel joints, fancy type with CP neck9\" long made to shape, complete all as specified and directed. |
| 57 | S&F in repairs for 600mm x 450mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed |
| 58 | S&F in repairs brass chromium plated tubular towel rail 20mm dia \"D\" type 60cm long between flanges, complete all as specified and directed. |
| 59 | S&F in repairs 32 / 40mm bore CP waste coupling for sink / WHB / urinal (half or full threaded) for discharge pipe (minimum weight 45gms), complete all as specified and directed. |
| 60 | S&F in repairs 75mm outer dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with clamp or laid in trenches, complete all as specified and directed. |
| 61 | S&F in repairs 110mm outer dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with clamp or laid in trenches, complete all as specified and as directed. |
| 62 | S&F 75mm size PVC (SWR) bends of any radius, complete all as specified and directed. |
| 63 | S&F 110mm size PVC (SWR) bends of any radius, complete all as specified and directed. |
| 64 | S&F 110mm size PVC bore (SWR) branch piece, single Y equal or unequal, complete all as specified and directed. |
| 65 | S&F in repairs 110mm bore PVC (SWR) \"S\" trap, complete all as specified and directed. |
| 66 | S&F 100/75mm outlet PVC (SWR) floor trap with chromium plated grating including Jointing to waste pipe and fixed in cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), complete all as specified and directed. |
| 67 | S&F in repairs 125mm dia CP grating doom with waste hole, complete all as specified and directed. |
| 68 | S&F in repairs 15mm size PVC connections with PTMT nuts of length 600mm, complete all as specified and directed. |
| 69 | S&F in repairs 15mm dia Angle valve, cast copper alloy, chromium plated screwed down, high pressure screwed both ends for iron pipe or for union and fixed, complete all as specified and directed. |
| 70 | S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe (minimum weight 210 gms) including dismantling existing water tank and removing from site, complete all as specified and directed. |
| 71 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 72 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 73 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 74 | Dismantling of timber scantlings 40 sqcm and over in section, in any position unframed work, complete all as specified and directed. |
| 75 | M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 Gde-E-165,complete all as specified and as directed. |
| 76 | M&L for rollled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors,fixed with angle cleats or other connecting plates, wind Tie etc. conforming to Fe-410-W (gde-E-250) Quality A, complete all as specified and as directed. |
| 77 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe-410-W (Gde-E-250) quality A, complete all as specified and directed. |
| 78 | M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings conforming to Fe-410- W (GdeE-250) quality B (exclusive or steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, complete all as specified and directed. |
| 79 | M&L for plain cement concrete, 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregates), as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 80 | Demolition ofcement concrete (unreinforced)in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and as directed. |
| 81 | M&L for 75mm thick plain cement concrete, 1:3:6, type C-2(using 40mm graded crushed stone aggregate) as in plinth protection, finished even and smooth without extra cement, complete all as specified and directed. |
| 82 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 40mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and direction. |
| 83 | M&L for 75mm thick plain cement concrete, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base, complete all as specified and directed. |
| 84 | M&L Earth work in excavation by mechanical means (hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m in any type of soil, complete all as specified and directed. |
| 85 | All as per Ser item No 83.00 here in before but exceeding 1.5m in depth and n.exc 3.0m in depth. |
| 86 | M&L for plain cement concrete, 1:4:8, Type D-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed. |
| 87 | M&L for Reinforced cement concrete, M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 88 | M&L for Reinforced cement concrete, M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) for columns, pillars, piers, posts and struts etc., under-reamed piles and mass concrete, complete all as specified and directed. |
| 89 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter Flat rough finished surfaces of concrete complete all as specified and directed |
| 90 | Formwork to sides of pillars, posts, struts, piers, columns, and stanchions Square and rectangle or polygon, complete all as specified and directed. |
| 91 | M&L for MS TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooking for columns, hooking ends and binding with and including mils steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 92 | M&L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 93 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finishing even and smooth without using extra cement, complete all as specified and directed. |
| 94 | Preparation of new surface of wall and applying two coats of cement based paint over one coat of primer including scaffolding up to 15m height, complete all as specified and directed. |
| 95 | Preparation of new steel surface and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide primer, complete all as specified and directed. |
| 96 | Schedule \"A\" Part-II (E/M Work) |
| 97 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point includingfixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made asper conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surfaceand finishing the surfaces as per existing,complete all as specified and directed. |
| 98 | M&L for Point wiring for light / fan point controlled by one way switch 6 Amps 240 volts with 1.5 sqmmcopper conductor FRLSH(multistrand) PVC insulatedISI marked unsheathed copper wire 1100 volt grade in and including concealed conduit, non metalic rigid PVC medium grade ISI marked conduit not less than 19 mm with all fittings& other accessories and also includingPVC insulated ISI marked unsheathed FRLSH copper wire cable 1100 volts grade of size 1.5 sqmm copper conductor as earth wire to common earth dolly including concealed in wall / ceiling,modular MS box with modular cover plate with frame suitable for modular switches, sockets, fan regulatoretc for the following :- Note - Colour code of cable Phase-Red, Neutral- Black and Earth -Green) |
| 99 | All as per Ser item No 96.00 here in above but 3 pin 6 Amps socket outlet point controlled by one switch on independent Board. |
| 100 | All as per Ser item No 96.00 here in above but 3 pin 6 Amps switch socket outlet point on same board. |
| 101 | All as per Ser item No 96.00 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmmfor 15 Amps power point. |
| 102 | S&F Modular switch 1 way, 6 Amp, 230 volts ,1 Module, complete all as specified anddirected. |
| 103 | S&F modular Socket6 Amp, 230 volts,5 Pin universal, 2 Module, complete all as specified and directed. |
| 104 | S&F Modular switch 1 way, 16 Amp, 240 volts, 1 Module, complete all as specified and directed. |
| 105 | S&F Modular socket 6/16 Amp (euro socket), 250 volts, 2 Module, complete all as specified and directed. |
| 106 | S&F modular step type fan regulator suitable for 120 watt 250 volts, 2 Module, complete all as specified and directed. |
| 107 | S&F Ceiling rose, surface bakelite 65 x 50 mm, 3 terminals fixed on PVC Round Block, complete all as specified and directed. |
| 108 | S&F energy efficient 20 watt LED integrated batten type luminaires suitable for wall or ceiling mounting with built in LED Chip & integral LED driver, Aluminiumchannel housing & Polycarbonate diffuser of length 1200 mm (approx.), color temperature 6500 K or as directed, luminaire efficacy not less 100 lm/W with all accessories, fixing arrangement internally pre-wired, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting, complete all as specified and directed. |
| 109 | S&F 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5 sqmm copper conductor multistrand PVC insulated cable from ceiling rose to fitting drawn through PVC flexible conduit, complete all as specified and directed. |
| 110 | S&F 10 Watt LED bulk head type with high out put , 220 V AC, color temperature 6500 K or as directed, lumens 1000 lm with all accessories, IP-65 protection, dust and water resistant ,surge protection up to 2.5kV, PC opal high efficiency diffuser, LM 80 tested made die cast aluminium housing with complete assembly, suitable for surface / wall mounted with driver holder including connecting up using 1.5 Sqmm copper conductor multistarnd PVC insulated cable,complete all as specified and directed. |
| 111 | S&F in repairs 300mm sweep heavy duty exhuast fan, 900 RPM turbo force model single phase including all accessories as per manufacturer norms and unserviceable fan deposited in MES store yard etc., complete as specified and directed. |
| 112 | S&F 25 Litre capacity storage type water heater (Geyser), BEE 5 Star rated, vertical wall mounting type made out of CRCA outer body stainless steel storage tank, titanium enamelled heating element thermostat, thermal cutout, glass wool including 15 mm, 450 mm long (cold water pipe ), 15 mm, 450 mm long armourd pipe (hot water pipe) etc complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper multistandred cable with top indicator plug top 15 amp from geyser connection to socket including hold fast for fixing of new geyser and writing the MES No., complete as specified and directed. |
| 113 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories 230V, 1200 mm sweep, minimum air delievery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC), complete all as specified and directed. |
| 114 | Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 10.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 10.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 10 sqmm copper cable & 1 run of 10 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit. |
| 115 | Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 6.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit. |
| 116 | S&F 100 Watt LED flood light, IP-66 high power with pressure die cast aluminium housing complete with all accessories including 3 core flexible cable from ceiling rose to connector of fitting etc., complete as specified and directed. |
| 117 | S&F epoxy powder coated or polystrene insulated material sheet metal enclosure, factory made, (double door)4 way VTPN suitable for MCCB DB\"s 415 Voltswith 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting, complete all as specified anddirected. |
| 118 | S&F epoxy powder coated or polystrene insulated material sheet metal enclosure, factory made, (double door) 8 way single pole & neutral suitable for MCB DB\"s 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting, complete all as specified and directed. |
| 119 | S&F 100 Amps MCCB, 3 pole 16 KA working on 415 Volts 50 HZ AC supply, complete all as specified and directed. |
| 120 | S&F MCB of single poles and current carrying capacity 6 to 32 Amp,240V, 10 KA \"B\" curve, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 121 | S&F MCBsingle pole and neutral ISI marked `B\" seriesworking on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40-63 Amps 10 KA breaking capacity etc all as specified and directed. |
| 122 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.25 mtr below normal ground level, connected to galvanized iron wire 4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4)type B-1 (using 20mm gradedcrushed stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh,and 40 mm dia GI light grade earth lead protection pipe including taking down old one, complete all as specified and directed. Note: (i) The unit rate includesmain earthing lead/strip from earth electrode to test point up to 7.5 meter (ii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department. |
| 123 | Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 25 Sqmm 4 core, conforming to IS 1554 Part I / ISI marked, 1100 Volt grade, including cable glands , cable lugs etc, to suitablethe cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc. including taking out unserviceable cable, complete all as speccified and directed. |
| 124 | Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 16 Sqmm 2 core, conforming to IS 1554 Part I / ISI marked, 1100 Volt grade, including cable glands , cable lugs etc, to suitablethe cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc. including taking out unserviceable cable, complete all as speccified and directed. |
| 125 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 126 | Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing complete all as specified and directed.Note: Qty clubbed for B/R and E/M portion. |
| 127 | Removing excavated material to a distance n.exc 50 m & depositing where directedat a level n. exc 1.50 m above the starting point, complete as specified and directed.Note: Qty clubbed for B/R and E/M portion. |
| 128 | M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed. |
| 129 | M&L for laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed |
| 130 | S&F 40mm dia galvanised steel tube, light grade, for protection of copper strip / cable at wall and duct / road / trench, complete all as specified and directed. |
| 131 | S&F in replacement of Feeder pillar board, kiosk type, LT (415 Volts, 50 Hz, 3 Phase, 4 wire supply) floor mounted, factory assembled, outdoor type weather and vermin proof (Protection class IP-54) made out and 3.15mm thick MS sheet CRCA sheet aluminiumbus bar of 200 Amps capacity with hingedopening, rubber lining, lockingarrangement, minimum 3 outgoings, painted externally and internally with two coats of synthetic enemel gray paint first quality ovar a coat of red oxide primer,complete comprising of following:-(a)MCCB4 Pole , 250 Amps, rupturing capacity 36 KA, 440 Volts, adjustable type - 01 Nos as incoming(b)MCCB3 Pole, 100 Amps, rupturing capacity 36 KA, 440 Volts, adjustable type - 02 Nos as outgoing(c)MCCB 3 Pole , 63 Amps, rupturing capacity 36 KA, 440 Volts, adjustable type - 01 Nos as outgoing(d)Power contractor suitable 40 Amps 415 volts - 04 Nos(e) Indicator LED phase lamps 03 Nos (R, Y, B) - 01 Set(f)Volt meter 0-500 Volts with selector switch - 01 No(g)Ammeter 0 - 300A with selector switch with CTs - 01 No(h)Platform for the feeder pillar board with PCC 1:2:4, 15cm thick in foundation, brick (sub class B) work in CM 1:6, redering 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in padding on top and grouting legs of panel. The platform shall be 450mm height above the ground level. |
| 132 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, completeall as specified and directed. |
| 133 | NOTE: (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall bemeasured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted. |
| 134 | Deduction to be made from BOQ for Schedule \"A\" Part-II (Credit Schedule from dismantling / taking down items) worth Rs 34,535.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy