| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-12-2025 | Amdt1 | Date | 14-01-2026 |
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames not exceeding 1.5 Sqm each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified and as directed by Engineer-in-charge. |
| 2 | Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4.0 Sqm each with shutter(s) (without taking off shutters from the frame), including removing to store, complete all as specified and as directed by Engineer-in-charge. |
| 3 | M&L for factory made pressed steel frames, conforming to IS, having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges (04 Nos), lock strike plate, etc., and fixed complete all as specified and as directed by Engineer-in-charge. |
| 4 | M&L for factory made pressed steel frames, conforming to IS, having profile 105 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges (04 Nos), lock strike plate, etc., and fixed complete all as specified and as directed by Engineer-in-charge. |
| 5 | S&F factory made 35 mm thick Flush shutters, solid core construction with block board core and plywood face panels, both faces covered with decorative face veneer of thickness 1.5 mm with lipping/ frame to match complete all as specified and directed by Engineer-in-Charge. |
| 6 | S&F 30 mm thick 2nd class hard wood, Glazed and skeleton shutters, factory made, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing chamfered plain or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats complete all as specified and as directed by Engineer-in-charge. |
| 7 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Clerestory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed Stainless steelscrews having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ Stainless steel dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: Material test certificate & authenticity certificate shall be produced by contractor while claiming payment. |
| 8 | S&Ffactory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter all as per direction of Engineer-In- Charge. Note: Material test certificate & authenticity certificate shall be produced by contractor while claiming payment. |
| 9 | M&L for Plywood (soild), 18/ 19 mm thick, type BWR, fixed with screws to timber frame work including PVC self adhesive tape as beading in cub board shelves/ cabinet works complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L for 0.9 mm thick Decorative laminate, type 1 of surface finish, colour and pattern as approved by GE, fixed with approved adhesive as per manufacturer\"s instructions complete all as specified and as directed. |
| 11 | Supply and fixing 25 mm thick factory made single extruded WPC (Wood Polymer Composite) solid Plain board comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate & Natural Fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant, including PVC Beading on exposed surface complete all as specified and as directed by Engineer-in-Charge.Note: Material test certificate & authenticity certificate shall be produced by contractor while claiming payment. |
| 12 | S&F Solid PVC Wall Lining consisting of 5 mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on wall/ PVC frame as per specifications and drawing complete all as specified and as directed. |
| 13 | S&F Stainless steel cupboard locks, 2 lever with 2 Nos of keys complete all as specified and as directed by Engineer-in-Charge. |
| 14 | M&L for plain cement concrete 1:3:6, type C-1 Nominal mix (using 20 mm graded stone aggregate) as in back filling the chowkats, complete all as specified and as directed by Engineer-in-charge. |
| 15 | M&L for providing cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in blocks for fixing hold fasts, in coping, bed plates, roof kerbs, mud stop and the like including necessary form work and weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-charge. |
| 16 | S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of apperture 1.40 mm fixed with tinned tack or stainless wire stapples complete all as specified and as directed by Engineer-in-charge. |
| 17 | S&F 4 mm thick float glass, ordinary quality and glazing with Silicon sealent, size in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge. |
| 18 | S&F float glass, 4.8 mm thick, ordinary quality and glazing with Silicon sealent, size in squares exceeding 0.5 sqm in each pane, complete all as specified and as directed by Engineer-in-charge. |
| 19 | S&F Stainless steel butt hinges, medium weight, 100 mm with stainless steel screws complete all as specified and as directed by Engineer-in-charge. |
| 20 | S&F mild steel ordinary rat tail rod pattern springs, 300 mm long including roller and roller plate complete, fixed to wooden/ steel chowkat complete all as specified and as directed by Engineer-in-Charge. |
| 21 | S&F 150 mm long extruded aluminium alloy anodised handles,fabricated type complete all as specified and as directed by Engineer-in-Charge. |
| 22 | S&F Aluminium anodised barrel tower bolt of extruded section of size 150 mm long complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Supply and fixing aluminium alloy anodised sliding door bolt 300 mm long with hasp & staple (Bolt type) and fixing clips of sheet cast or extruded section of cast aluminium alloy complete all as specified and as directed by Engineer-in-Charge. |
| 24 | S&F floor door stopper, aluminium alloy body and tongue, anodised, with 140 mm long cover plate and hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S&F in repair floor door stopper, aluminium alloy body and tongue, anodised, with 140 mm long cover plate and hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer-in-Charge. |
| 26 | S&F Continuous (piano) hinges, stainless steel, width of flaps 30 mm (when open) including star head with stainless steel screws complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Supply & Fixing chromium plated food grade stainless steel baskets ofmoduler kitchen (storage basket, cup and saucer basket, jas basket, thali basket, cutlery basket, grain trolley, plain basket, bottle pull out etc.) minimum loading capacity 65 KG, made out of minimum 6 mm dia stainless steel round bars, properly welded and joints finish by grinding, chromium plated finish,fixed properly with WPC board of any thickness as per approved design, including fixing of auto closing hinges, ball bearing runners of any description, stainless steel handles fixing clips, sliding frame structure, SS screw etc complete all as specified and directed by Engineer-in-charge. |
| 28 | Note : 1. Weight of fitting/ fixtures like handles, hinges, ball bearing runners, telescopic channels etc will not be measured.2. Only weight of SS wire basket will be measured before fixing.3. Labour for Fixing of all Fitting/ fixtures like handles, hinges, ball bearing runners, telescopic channels etc., are included in this item. fitting/ fixtures shall be measured and paid in separate items as supply only. |
| 29 | Supply and fixing soft auto closing hinges openable at 0 degree for kitchen cabinet shutters complete all as specified and directed by Engineer-in-charge. |
| 30 | Supply and fixing magnetic catcher cum silencer, mild steel, CP and fixed with standard steel screws, complete all as specified and as directed. |
| 31 | Supply and fixing soft auto closing 45 mm wide Ball bearing runners with telescopic Channel, 20 Inch (full extension), load capacity 50 kgs, Black powder coated complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply and fixing of factory made 25 mm thick single extruded WPC (Wood Polymer Composite) solid single side PVC Laminate with PVC foil of minimum 14 Microns thick of approved colour shade Board comprising of virgin polymer of K value 58-60 (suspension grade) calcium carbonate & Natural Fibers (wood power/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant , including PVC Beading on exposed surface all as per the direction of Engineer-in-Charge. Note : Material test certificate& authentication should be provided by the manufacturing company. |
| 33 | S&F Stainless steel finish zinc chrome handles, curve design, 144 mm size complete all as specified and as directed by Engineer-in-Charge. |
| 34 | S&F Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts of extruded section of size 150 mm long complete all as specified and as directed by Engineer-in-Charge. |
| 35 | S&F Brass sliding door bolt, 300 mm long with sand or die-cast hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 36 | S&F 150 mm long extruded section Brass handles, cast type, polished, bright handles complete all as specified and as directed by Engineer-in-Charge. |
| 37 | S&F Mortice lock, vertical type, brass, 4 levers size 100 mm to any type of doors complete all as specified and as directed. |
| 38 | M&L mild steel workin framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 39 | M&L for preparation of new wooden surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed by Engineer-in-Charge. |
| 41 | Demolition of brick work built in cement mortar including all quoins arches pillars removing rubbish outside MoD land to a distance of 5 KM complete all as specified and directed. |
| 42 | Material and labour for brickwork with sub class ‘B’ bricks (old size bricks), straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-charge. |
| 43 | All as per serial item No 41.00 here-in-before but except bricks (using old serviceable bricks obtained from ser item No 40.00 here-in-above) complete all as specified and as directed by Engineer-in-charge. |
| 44 | M&L for Brickwork with sub-class ‘B’ bricks (old size bricks), straight or curved on plan to any radius in half brick thick walls, for partition wall, parapet in balcony and other similar work built in Cement Mortar 1:4 complete all as specified and as directed by Engineer-in-Charge. |
| 45 | Taking down cement or cement lime plaster on brick or stone walls & ceiling etc incl raking out joints, hacking for key scrubbing down with water etc., complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Material and labour for Rendering 15 mm thick in Cement and Sand mortar 1:6 over fair face brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 47 | Material and labour for Rendering 15 mm thick in Cement and Sand mortar 1:4 over fair face brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 48 | M&L for 5 mm thick rendering in Cement Mortar 1:3, on concrete/ brick surfaces as in ceiling, facia, chajja, etc. finished fair and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 49 | M&L for preparation of newly plastered surfeces of walls and applying Putty of average thickness 1 mm over the plastered @ 1kg per sq. mtr. and preparing the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust, with and including M&L for one coat of water proofing/ damp-proof primer @ 1 litre per 5 square metre (undiluted) to be applied using an airless spray machine of with a flow rate of 2 litre per minute having a pressure of 3300 PSI including M&L for applying two coats of oil bound distemper using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer andaccessories for applying distemper should be able to spray in hard-to-reach areas and penetration of distemper on the surface at any height complete all as specified and directed. |
| 50 | All as per Serial item No. 48.00 here-in-before but on ceiling surfaces. |
| 51 | M&L for complete removal of existing treatmentfrom wall surfaces, removing of nails, making good holes, cracks etc., and applying Putty of average thickness 1 mm over the plastered @ 1kg per sq. mtr. and preparing the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust with and including M&L for one coat of water proofing/ damp-proof primer @ 1 litre per 5 square metre (undiluted) to be applied using an airless spray machine of with a flow rate of 2 litre per minute having a pressure of 3300 PSI including M&L for applying two coats of oil bound distemper using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer andaccessories for applying distemper should be able to spray in hard-to-reach areas and penetration of distemper on the surface at any height complete all as specified and directed. |
| 52 | All as per Serial item No. 50.00 here-in-before but on ceiling surfaces. |
| 53 | Note for serial No 48.00 to 51.00:- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :-(a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer ofthe materials like Oil bound distemper, putty etc. after approval of the GE.(b) The contractor shall submit the memorandum of understanding (MoU) with at least one of the manufacturers mentioned in the contract, within 15 days of acceptance of tender, failing which the contract will be liable to be cancellled under condition 54 of IAFW-2249. MOU shall be on the Manufacturer\"s letter Head duly ink signed by both the parties (i.e., contractor and manufacturer) clearly mentioning all the terms and conditions of above items.(c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures.(d) Work in patches and in narrow widths, bands, cornices, pilasters etc., and cutting in edge of line where necessary......Contd 51.02 |
| 54 | Contd..(e) Spreading and removing covering to doors, windows, floors, fittings etc., to protect them from splashes.(f) Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(g) Sample patch of 10 Sqm area shall be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work.(h) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garrison Engineer for the effectiveness of the Oil bound distemper for 3 years during the guarantee period. |
| 55 | M&L for preparation of newly plastered surfaces of walls and applying cement base Putty of average thickness 1 mm over the plastered surfaces@ 1 kg per sq. mtr. and preparing the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Gritto make the surface free from dust, loose paint etc., with and including M&L for one coat of water proofing/ damp-proof primer @1 litre per 5 square metre diluted with 30% by water to be applied using an airless spray machine of with a flow rate of 2 litre per minute having a pressure of 3300 PSI including M&L for two coats of water based premium acrylic smooth exterior emulsion @ 1 litre per 5 square metre diluted with water as per manufacturer\"s instruction of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties, applied over priming coat with airless spray machine of paint application with a flow rate of 2 Litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint at any height complete all as directed. |
| 56 | M&L for complete removal of existing treatmentfrom wall surfaces by scrapping, removing of nails, making good holes, craks etc., and applying cement base Putty of average thickness 1 mm over the plastered surfaces@ 1 kg per square metre and preparing the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Gritto make the surface free from dust, loose paint etc., with and including M&L for one coat of water proofing/ damp-proof primer @ 1 litre per 5 square metre diluted with 30% by water to be applied using an airless spray machine of with a flow rate of 2 litre per minute having a pressure of 3300 PSI including M&L for two coat water based premium acrylic smooth exterior emulsion @ 1 litre per 5 square metre diluted with water as per manufacturer\"s instruction of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties, applied over priming coat with airless spray machine of paint application with a flow rate of 2 Litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint at any height complete all as directed. |
| 57 | Note for Serial item No 52.00 and 53.00:- The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :-(a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer ofthe materials like Exterior Emulsion paint, putty etc after approval by the GE.(b) The contractor shall submit the memorandum of understanding (MoU) with at least one of the manufacturers mentioned in the contract, within 15 days of acceptance of tender, failing which the contract will be liable to be cancellled under condition 54 of IAFW-2249. MOU shall be on the Manufacturer\"s letter Head duly ink signed by both the parties (i.e., contractor and manufacturer) clearly mentioning all the terms and conditions of above items.(c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures.(d) Work in patches and in narrow widths, bands, cornices, pilasters etc., and cutting in edge of line where necessary. ...Contd...53.02 |
| 58 | Contd...(e) Spreading and removing covering to doors, windows, floors, fittings etc., to protect them from splashes.(f) Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge.(g) Sample patch of 10 Sqm area shall be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work.(h) Guarantee :- The contractor shall furnish a guarantee certificate from approved make in favour of Garison Engineer for the effectiveness of the weather proof paint for 5 yrs during the guarantee period. |
| 59 | M&L for Preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed by Engineer-in-Charge. |
| 60 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge. |
| 61 | S&F Mild steel works as in door hold Fast conforming to Fe-290 (Gde-165) complete all as specified and as directed by Engineer-in-Charge. |
| 62 | S&F 0.80 mm thick mild steel, plain, black sheet in hearths, covering to door shutter, covering to door chowkats (frames), cut to size, edges beaded if directed, holes punched including round headed screws clout nails or rivets and fixed to wooden or steel members, etc. with plain 40 mm lap joints or welded, revetted seams including bending, turning up mitred angle, stopped ends, outlets as required complete all as specified and directed. |
| 63 | S&F MS rolled sections as in roof trusses (framed), trussed, purlins, rails and fastenings and bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. similar work conforming to Fe-410-W(Gde-E-250) quality B, complete all as specified and as directed by Engineer-in-Charge. |
| 64 | S&F Steel tubular section of any size and shape including special shaped washer fixing in any position etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and as directed by Engineer-in-Charge. |
| 65 | Demolition of reinforced cement concrete in floors, chajjas, landing slab in any position or height and similar suspended works and removing rubbish outside MoD land upto a distance of 5 KM complete all as specified and as directed by Engineer-in-Charge. |
| 66 | M&L for Reinforced Cement Concrete 1: 1½ :3 (nominal mix), type-A (using 20 mm graded stone aggregates) as in RCC slab supported on walls, beams etc., and shelves complete all as specified and as directed by Engineer-in-Charge. |
| 67 | M&L for Mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 68 | All as per serial Item No 62.00 here-in-before but 5 to 10 mm dia as in stirrups, spacers. |
| 69 | Use and waste of Formwork to edges of concrete flats and sides of RCC/ PCC bands in walls, horizontal or sloping and similar works exceeding 10 cm but not exceeding 20 cm wide complete all as specified and directed by Engineer-in-Charge. |
| 70 | Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, chajjas and similar works not exceeding 200 mm thick (Horizontal or sloping) for flat rough finish surface of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 71 | Repairing the edges of concrete chajjas, facias, slabs, columns & the like by providing PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) including all necessary form work and/ or provision of rendering 15 mm thick (average thickness) in cement mortar 1:3, after applying a coat of cement slurry@ 3 kg/ Sqm, surface finished even and fair, surface area not exceeding 450 mm wide, in patches including taking down swoolen/damaged plaster or concrete complete all as specified and as directed by Engineer-in-Charge. |
| 72 | Taking up or down GI steel tubing 15 mm with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-charge. |
| 73 | Taking up or down GI steel tubing 20 mm with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-charge. |
| 74 | S&F 20 mm (outer dia) CPVC pipes, SDR 11 and Plain CPVC SDR 11 fittings, fixed on walls/ ceiling or laying in floors, complete all as specified and as directed by Engineer-in-Charge. |
| 75 | S&F 25 mm (outer dia) CPVC pipes, SDR 11 and Plain CPVC SDR 11 fittings, fixed on walls/ ceiling or laying in floors, complete all as specified and as directed by Engineer-in-Charge. |
| 76 | S&F 20 mm dia CPVC brass Elbow complete all as specified and as directed by Engineer-in-Charge. |
| 77 | S&F 25 mm dia CPVC brass Elbow complete all as specified and as directed by Engineer-in-Charge. |
| 78 | S&F 20 mm dia CPVC brass Tee complete all as specified and as directed by Engineer-in-Charge. |
| 79 | S&F 25 mm dia CPVC brass Tee complete all as specified and as directed by Engineer-in-Charge. |
| 80 | S&F Male Brass Threaded Adaptor, 20 mm bore (MTA/ MBTA) for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge. |
| 81 | S&F Male Brass Threaded Adaptor, 25 mm bore (MTA/ MBTA) for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S&F Female Brass Threaded Adaptor, 20 mm bore (FTA/ FBTA) for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge. |
| 83 | S&F Female Brass Threaded Adaptor, 25 mm bore (FTA/ FBTA) for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge. |
| 84 | S&F 25 mm dia CPVC brass Tank Adaptor complete all as specified and as directed by Engineer-in-Charge. |
| 85 | S&F 25 mm dia CPVC brass Union complete all as specified and as directed by Engineer-in-Charge. |
| 86 | Disconnecting existing tanks of capacity exceeding 250 litres and not exceeding 500 litres, setting aside (or lowering if required) for repairs, cleaning etc., and hoisting if required, reconnecting and re-fixing in position (cleaning and repairing etc shall be measured separately) complete all as specified and as directed by Engineer-in-Charge. |
| 87 | All as per serial Item No 81.00 here-in-before but of capacity exceeding 500 litres and not exceeding 1000 litres. |
| 88 | Disconnecting existing tanks of capacity exceeding 250 litres & not exceeding 500 litres, and removing to store complete all as specified and as directed by Engineer-in-charge. |
| 89 | Disconnecting existing tanks of capacity exceeding 500 litres & not exceeding 1000 litres, and removing to store complete all as specified and as directed by Engineer-in-charge. |
| 90 | S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 91 | S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 92 | M&L for Cutting chases, pinning in, of brick walls or concrete surfaces, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of inserting sheets, landings, steps, sills, sunshades, shelves, lintels, etc.; for concealed water tubing, concealed conduit wiring etc., and making good, cutting not exceeding 10 cm girth complete all as specified and directed by Engineer-in-Charge. |
| 93 | M&L for Brushing neat cement slurry with 3.0 kg of cement per square metre, complete all as specified and as directed by Engineer-in-Charge. |
| 94 | M&L for rendering 10 mm thick in cement mortar 1 : 3 mixed with liquid water proofing compound as per manufacturer\"s instruction on concrete/ brick sunken/ roof surfaces, finished even and smooth without using extra cement complete all as specified and as directed.Note: WPC shall be measured and paid separately. |
| 95 | Supply only water proofing compound, ISI marked, complete all as specified. |
| 96 | Dismantling Brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed by Engineer-in-Charge. |
| 97 | Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by Engineer-in-Charge. |
| 98 | Removing excavated material (soil/ dabries) to a distance exceeding 1.5 KM but not exceeding 5 KM and depositing where directed complete all as specified and as directed by Engineer-in-Charge. |
| 99 | Material and labour for cement concrete 1:3:6 type C-0 (using 12.5 mm graded stone aggregates) as in roof padding etc., finished rough complete all as specified and as directed by Engineer-in-charge. |
| 100 | M&L for Cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 101 | M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per square metre over cleaned and dry sunken/ roof surfaces including parapet etc., including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. |
| 102 | Material and labour for providing and laying APP based polymeric membrane in sunken/ roof of minimum weighing 3 kg/sqm and minimum 3 mm thick, reinforced with polyster non woven fabric (wt. notless than 150 gms/sqm) land on primed surface by torch application. The APP membrane shall be laid using torch-on application with minimum 10 cm side overlap and 15 cm end overlap. The APP memberane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet complete all as specified and directed by Engineer-in-Charge. |
| 103 | M&L for 20 mm thick grey coloured PCC tiles 25 cm x 25 cm, machine pressed laid over and including 20 mm thick screed or bedding layer in cement mortar 1:4 mixed with and including waterproofing compound and joints grouted & pointed flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and as directed by Engineer-in-Charge. |
| 104 | Demolition of cement concrete/ lean concrete etc. from sunken slab portion exceeding 15 cm thick but above ground floors, including removal of demolished material out of MD land complete all as specified and as directed by Engineer-in-Charge. |
| 105 | M&L for Plain cement concrete 1:5:10, type E-2 (usinge 40 mm graded brick aggregate) as in sunken filling and mass concrete complete all as specified and directed by Engineer-in-charge. |
| 106 | S&F 32 mm dia Galvanised steel tubes, \"light grade\" for spout pipe including cutting the same in short pieces with end cut to 45 degree complete all as specified and directed. |
| 107 | Demolition of cement concrete (unreinforced) in ground floors and pavings, not exceeding 15 cm thick (below or above GL) complete all as specified and as directed by Engineer-in-Charge. |
| 108 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish out of MD land to a distance 5 KM complete all as specified and directed. |
| 109 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed by Engineer-in-Charge. |
| 110 | M&L for 25 mm thick cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in sub base of floor as in level course, rough finish complete all as specified and directed by Engineer-in-Charge. |
| 111 | M&L for first quality double charged Vitrified Ceramic tiles, 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 Sqm but not exceeding 0.72 Sqm, in floors/ skirting etc., set and jointed with 4 mm spacer and grouting the joints of flooring/ skirting with epoxy grout mix of organic colour filler of desired shade, hardner, resin in the ratio of 8:1:2 laid over and including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 112 | M&L for first quality coloured non-skid Ceramic tiles, 7 to 8 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 Sqm but not exceeding 0.72 Sqm, in floors/ skirting etc., set and jointed with 4 mm spacer and grouting the joints of flooring/ skirting with epoxy grout mix of organic colour filler of desired shade, hardner, resin in the ratio of 8:1:2 laid over and including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 113 | M&L for first quality coloured non-skid Ceramic tiles, 7 to 8 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors/ skirting etc., set and jointed with 4 mm spacer and grouting the joints of flooring/ skirting with epoxy grout mix of organic colour filler of desired shade, hardner, resin in the ratio of 8:1:2 laid over and includingscreed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 114 | M&L for Glazed ceramic coloured tiles, 600 x 300 x 7-8 mm thick, set and jointed with 4 mm spacer and grouting the joints of wall with epoxy grout mix of organic colour filler of desired shade, hardner, resin in the ratio of 8:1:2, which shall be laid in pattern with two or more coloured tiles, over and including rendering 10 mm thick on brickwork or concrete surfaces, finished even and rough in cement mortar 1:4complete all as specified and as directed by Engineer–in-Charge. |
| 115 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar and removing rubbish out of MD land to a distance 5 KM complete all as specified and as directed by Engineer-in-charge. |
| 116 | M&L for16 to 18 mm thick granite slab (table rubbed polished) as in cooking platform, jamb, cill, step & riser, set and jointed with cement slurry and bedded over & including 15 mm thick screed bedding layer in cement sand mortar 1:4, & pointed with white/ coloured cement including grinding, rounded and chamfered edges and granite polishing etc., complete all as specified and as directed by Engineer-in-charge. |
| 117 | M&L for Baroda Green stone16 to 18mm thick (table rubbed and polished) in steps and riser, jambs, pillars, window cills, cooking platforms etc., bedded over & including 15 mm thick bedding layer of cement sand mortar (1:4), & pointed with white/ coloured cement including grinding, rounded and chamfered edges and granite polishing etc., complete all as specified and as directed by Engineer-in-charge. |
| 118 | M&L for 75 mm thick PCC 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in plinth protection laid in panelsfinish the top surfaces even and smooth without using extra cement including sealing compound complete all as specified and directed. |
| 119 | M&L for 75 mm thick Plain Cement concrete 1:4:8, type D- 2(using 40 mm graded stone aggregate), as in sub base of floors/ path etc. complete all as specified and as directed by Engineer-in-charge. |
| 120 | M&L for Providing and laying 60 mm thick with glossy finish on top factory made chamfered edge cement concrete paver block with grey cement and pigment of M-35 grade with colour, design & pattern(approved by GE) as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and as directed by Engineer-in-charge. |
| 121 | S&F Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed by Engineer-in-charge. |
| 122 | S&F factory made rubber moulded coloured chequered cement concrete tiles 300 mm x 300 mm x 22-25 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement and pigment to match the colour of tiles, laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engineer-in-charge. |
| 123 | M&L for RCC 1:2:4 (nominal mix), Type B-1 (using 20 mm graded stone aggregate) as in chajja or similar items complete all as specified and directed by Engineer-in-Charge. |
| 124 | S&F in repair vitreous china wash down water closet pan (Pedestal pattern) with seat cover, white (exluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed by Engineer-in-charge. |
| 125 | S&F in repair Vitreous china squatting pan \"orrisa\" pattern, size 580 x 440 mm, white, with integral floor rests (excluding flushing cistern) including connection to trap and to flushing pipe anti syphonage pipe etc., complete including making good to floor, complete all as specified and as directed by Engineer-in-charge. |
| 126 | S&F in repair Vitreous China One Piece EWC of size 365 mm x 655 mm x 765 mm with flushing cistern and connection pipe, P or S trap (closed pattern) including all necessary accessorie like rag bolts, kit/ gel gasket etc., including pvc seat cover, CP jet with connector pipe complete all as specified and as directed by Engineer-in-Charge. |
| 127 | S&F in repair corner vitreous china wash basin, white, of size 450 mm x 450 mm, with pedestal including CI brackets and cutting for and pinning in ends of brackets or erecting stands etccomplete all as specified and directed by Engineer-in-charge. |
| 128 | S&F in repair Flushing jet spray for pedestal pattern Water Closet, stainless steel, including flexible pipe and brass Chromium plated nuts, complete all as specified and directed by Engineer-in-charge. |
| 129 | S&F PVC SWR \"P\" or \"S\" trap, ISI marked, suitable for 100 mm bore, including jointing to pipe with solvent cement complete all as specified and as directed by Engineer-in-charge. |
| 130 | Supply and fixing in repair vitreous china wash hand basin, white, flat back, size 550 x 400 mm with padestal including CI brackets of suitable size, including cutting in wall and pinning in ends complete all as specified and directed by Engineer-in-Charge. |
| 131 | S&F in repair Bib taps, cast copper alloy with handle, chromium plated fancy type, long body with wall flange screwed down, suitable for 15 mm bore pipe complete all as specified and directed by Engineer-in-Charge. |
| 132 | S&F in repair Concealed type stop valve, cast copper alloy, screwed down, high pressure with handle, chromium plated, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete all as specified and as directed by Engineer-in-Charge. |
| 133 | S&F stop valves/ angle valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, screwed both ends for iron pipe or for unions, suitable for 15 mm bore pipe and fixed in repair complete all as specified and as directed by Engineer-in-Charge. |
| 134 | S&F in repair waste coupling of Brass, CP for wash basin, any colour, half or full threaded, suitable for 32 mm size discharge pipe complete all as specified and directed by Engineer–in-Charge. |
| 135 | S&F flexible PVC pipes of pressure rating 10 kgf/sqcm, waste pipesuitable for 32 mm dia waste coupling, complete all as specified and as directed by Engineer-in-Charge. |
| 136 | S&F in repair Brass, chromium plated overhead shower rose of size 200 mm x 200 mm (Square) with shower arm 600 mm long with flange, with swivel joints, any size, fixed to 15 mm bore pipe, complete all as specified and as directed by Engineer-in-Charge. |
| 137 | Supply and fixing in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed by Engineer-in-charge. |
| 138 | S&F in repair PVC valveless syphonic action type flushing cistern, low level, white, with PVC inlet ball valve, float and handle, 10 litre capacity and connection to pipes including 32 mm dia PVC long bend for squat pattern etc, set with concrete and making good to floor complete all as specified and directed by Engineer-in-Charge. |
| 139 | Supply and fixing looking mirror of size 600mm x 450mm of selected quality mounted on PVC frame and back fixed to wall with chromium plated brass screws and rawl plugs, fixed as in repair complete all as specified and as directed by Engineer-in-Charge. |
| 140 | Supply and fixing PTMT bathroom mirror cabinet of size of 400 mm x 500 mm, fixed with stainless steel screws with PVC rawl plugs complete all as specified and directed by Engineer-in-Charge. |
| 141 | S&F PVC connection 15 mm dia and 600 mm long with 2 Nos PTMT nuts, fixed in repair complete all as specified and as directed by Engineer-in-charge. |
| 142 | S&F in repair 75 mm bore PVC (SWR) floor traps, plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-charge. |
| 143 | S&F Stainless steel toilet paper holder fixed to wall with stainless steel screws complete all as specified and as directed by Engineer-in-Charge. |
| 144 | S&F in repair 15 mm bore 2 way Bib tap,chromium plated, fancy type, with crutch or butter-fly handle, screwed down, screwed for iron pipe or for brass ferrule etc all as specified and directed. |
| 145 | S&F in repair Pillar cock, single lever of 450 mm long fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and directed. |
| 146 | S&F in repair 25 mm stainless steel curtain rod fixed to brackets complete including fancy type brackets, finial cap and all fixing arrangement etc complete all as specified and as directed by Engineer-in-Charge. |
| 147 | S&F in repair 900 mm x 750 mm x 300 mm plate rack, made out of 1.00 mm thick stainless steel sheet grade SS-304 with shelves, hooks and railing to keep plates vertically and horizontally, including necessary fixing arrangement complete all as specified and directed by Engineer-in-charge. |
| 148 | S&F Stainless steel Grating doom 125 mm dia with or without waste hole of chromium plated fixed on floor/ nahani trap with cement mortar, fixed in repairs complete all as specified and directed by Engineer–in-Charge. |
| 149 | Supply and fixing in repair Stainless steel bathroom cloth Hooks, set of five hooks, solid body of best quality and fixed with brass screws with PVC rawl plugs complete all as specified and as directed by Engineer-in-Charge. |
| 150 | S&F in repair Brass, Chromium plated, Sink mixer (Swan neck), with swivel spout (Wall Mounted), suitable for 15 mm bore pipe for mixing hot & cold water, screwed down for iron pipe and fixed with connecting legs and wall flanges complete all as specified and as directed. |
| 151 | S&F in repair 15 mm bore, brass, chromium plated, Central Hole wash basin mixer, suitable for 15 mm bore pipe for mixing Hot and Cold water, screwed down for iron pipes complete all as specified and directed by Engineer–in-Charge. |
| 152 | S&F in repair Wall mixer system with L bend (for provision for over head shower), brass, chromium plated, fancy type, suitable for 15 mm bore pipe complete all as specified and as directed by Engineer-in-charge. |
| 153 | S&F corner glass shelf assembly, made out of 5.5 mm thick toughened glass, of radius 300 mm including 02 Nos. Chromium Plated metallic holding brackets, railing etc., fixed in repairs, complete all as specified and directed by Engineer-in-charge. |
| 154 | M&L for PVC(SWR) Nahani traps, 100 mm size with grating and cover including jointing to waste pipe with cement solvent fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate), fixed as in repair complete all as specified and as directed by Engineer-in-charge. |
| 155 | M&L for PVC(SWR) gully traps 125/ 110 mm size, setting and jointing to waste pipe with cement solvent fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate), fixed as in repair complete all as specified and as directed by Engineer-in-charge. |
| 156 | S&F in repair table top wash basin, vitreous China of size (600 mm x 450 mm x 150 mm), excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand bottle trap s/s etc., complete all as specified and as directed by Engineer-in-charge. |
| 157 | S&F in repairs stainless steel, soap dish of size 160 mm x 160 mm x 90 mm, fixed with plugs with chromium plated brass screws (for Baths of 3 cubical in each toilets) complete all as specified and as directed by Engineer-in-charge. |
| 158 | S&F in repair Tubular towel rod, 600 mm, chromium plated, fixed to walls with plugs and chromium plated brass screws complete all as specified and as directed by Engineer-in-charge. |
| 159 | S&F in repair sinks made of stainless steel l mm thick for kitchen orlaboratory with plugs, washers and waste; including SS waste coupling, PVC waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 mm x 420 mm and bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engineer-in-charge. |
| 160 | Material & Labour for providing and fixing stainles steel (Grade 304) railing made out of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, including dismantling of existing railing any type, complete all as specified and as directed by Engineer-in-charge.Note:- Weight of stainless steel shall be ascertained by the BOO convened by the GE. |
| 161 | Taking down AC rain water pipe of any size or pattern including all fittings heads, shoes, bends. Swan necks, etc., complete all as specified and as directed by Engineer-in-charge. |
| 162 | S&F PVC (SWR) 110 mm bore pipes, single socketed, in any lengths with rubber ring joints, fixed to wall with MS clamp complete all as specified and as directed by Engineer-in-charge. |
| 163 | S&F PVC (SWR) 75 mm bore pipes single socketed, in any lengths with rubber ring joints, fixed to wall with MS clamp complete all as specified and as directed by Engineer-in-charge. |
| 164 | S&F 110 mm bore PVC (SWR) bend of any radius with access door complete all as specified and as directed by Engineer-in-charge. |
| 165 | S&F 75 mm bore PVC (SWR) bend of any radius with access door complete all as specified and as directed by Engineer-in-charge. |
| 166 | S&F 110 mm bore PVC (SWR) branch piece, single (single Y), equal or unequal with oval access door complete all as specified and as directed by Engineer-in-charge. |
| 167 | S&F 75 mm bore PVC (SWR) branch piece, single (single Y), equal or unequal with oval access door complete all as specified and as directed by Engineer-in-charge. |
| 168 | S&F in repair PVC (SWR) vent cowl, 110 mm dia complete all as specified and as directed by Engineer-in-charge. |
| 169 | S&F of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour (approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling plain or corrugated steel sheeting, any gauge, thickness in roof coveringsall as specified and directed. |
| 170 | S&F 2 mm thick Fibre glass reinforced translucent plain sheeting fixed with coach screws and washer in roof, wall etc., complete all as specified and as directed by the Engineer-in-Charge. |
| 171 | M&L for Chippings of existing surfaces unsound weak/ loose concrete/ cover of reinforcement etc. complete all as specified and as directed by Engineer-in-charge. |
| 172 | M&L for cleaning of existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose materials, diet etc. complete and applying two coats of alkaline rust converting primer with a coverage of 350 gm/sqm on the existing rebar and allowing it to react with rust for 6 hours and forming corrosion resistant, insoluble and adherant protective layer, including cleaning the reinforcement with wire brushing to remove rust spalls, with time interval of 1 hour between the coats.(Measurement per sqm surface area of concrete) Product : Sika RustOff - 100 or equivalent in performance as approved by GE, complete all as specified and as directed by Engineer-in-Charge.Make: SIKA/ CICO/ STP/ FOSROC/ ROFF CHEMICALS/ PIDILITE |
| 173 | M&L for providing and application of zinc rich epoxy anti-corrosive protective coating for rebar corrosion protection system in 2 coats of 0.40 kg/sqm. The product should confirm carbonation resistance of 2 mm and bond strength < 1 N/sqmm according to ASTM C 882-78.(Measurement will be surface area of concrete).Product : Sika Friazinc R@ or equivalent in performance as approved by GE, complete all as specified and as directed.Make: SIKA/ CICO/ STP/ FOSROC/ ROFF CHEMICALS/ PIDILITE |
| 174 | M&L for providing and fixing additional corrosion resistant hot dip galvanised steel rebar Fe-500 or height grade as per required diameter in various structural elements such as columns, beams and slabs etc, to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with ETA Approved Epoxy based anchoring adhesive Sika Anchor Fix 3030 or equivalent as approved by GE complete all as specified and directed as the following :- (a) Drilling and rebaring of 10 mm dia x 160 mm deep. |
| 175 | M&L for providing and application of corrosion inhibiting impregnation coating designed for use as an impregnation for protection of steel reinforcement within unexposed concrete in consumption of 0.5 kg/sqm complete all as specified and directed. The product should be arnino alcohol and inorganic combination based migratory corrosion inhibitor for both cathodic and anodic protection. |
| 176 | M&L for providing and mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer\"s specification including preparation of surface by chipping and throughly cleaning of surface complete whereever required and as per directions of Engineer-in-Charge in consumption of 0.4 kgs/sqm. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 MPa complete all as specified and directed. |
| 177 | M&L for providing and applying 15-20 mm thick layer of single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortor conforming to EN 1504-3 Class R4 on exposed concrete surface as per technical specification. Material should have Compressive Strength > 55 MPa as per EN:12190, chloride iron content < 0.05% as per EN:1015-17, Adhesive bond > 2.0 MPa as per EN: 1542, Carbonation resistance dk < control concrete (MC(0,45)) as per EN: 13295 & Elastic modulus > 20.0 GPa as per EN: 13412 (Complete finished item with all leads and lifts) complete all as specified and directed. |
| 178 | M&L for examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder upto 5-10 mm depth without damaging existing rebars, carefully removing carbonated concrete around the rebars upto 10 mm depth by low impact high frequency hammer/ chipper without damaging the sound concrete, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, depositing off the debris so generated on weekly basis outside the premises, etc, complete all as specified and directed. |
| 179 | M&L for providing and applying single component, high build, elastomeric, crack-bridging, resistance to CO2 & SO2 and Chloride ion diffusion, UV resistant, breathable acrylic coating, with elongation at break exceeding 200% Sikagard - 550 W IN applied intwo coats (each coat 100 micron DFT) on acrylic based primer at an average total thickness of 200 microns DFT in two coats including acrylic resin based primer as per the recommendation of the manufacturer complete all as specified and directed. |
| 180 | Note for serial item No 166 to 174:- The work shall be executed with steel scaffolding (Cup & lock system) having proper strength, size and thickness of standard, ledgers, cup lock, \"U\" Jack, base jacks, starting collor/ diagonal braces, connecting pins etc., to make the working platform strong and safe, min size of platform shall be 6 sqm. RCC repair/ retrofitting work shall be carried out at the height upto 2nd/ 3rd floor. Rates are deemed to be include the above provision and nothing extra shall be admissible on this account. |
| 181 | M&L for Providing and injecting chemical emulsion for Post Constructional anti-termite treatment of soil under existing floors using emulsion @one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by Engineer-in-Charge. |
| 182 | M&L for Providing and injecting chemical emulsion for Post Constructional antitermite treatment along external wall where the apron is not provided along the external wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed by Engineer-in-Charge. |
| 183 | M&L for Post Constructional Antitermite Treatment at points of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and as directed by Engineer-in-Charge. |
| 184 | M&L for applying two coats of synthetic enamel paint on new or previously untreated wooden surfaces exceeding 10 cm width or girth including preparation of new wooden surfaces complete all as specified and directed. |
| 185 | Supply and fixing powder coated (minimum thickness of powder coating 50 micron) aluminum anodised frame for windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed by Engineer-in-charge.Note:- Weight of Aluminium section shall be ascertained by the BOO convened by the GE. |
| 186 | S&F aluminium powder coated (min thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars,including (double shutter) glazing bars and without glazing bars weight of aluminium section not less than 0.55 kg/Rm including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100 mm long (2 No.) suitable handle (1 No.), tower bolt 2 Nos complete all as specified and as directed.Note:- Weight of Aluminium section shall be ascertained by the BOO convened by the GE. |
| 187 | Dismantling boarding, any description, fixed in any position fixed with nailscomplete all as specified and as directed by Engineer-in-charge. |
| 188 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete all as specified and as directed by Engineer-in-charge. |
| 189 | Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly drawn in and including concealed heavy duty PVC conduit of suitable size bore with all fittings terminated on and including new modular GI metal sunken box of thickness not less than 1.2 mm and suitable size of frame, cover for mounting modular switch, socket and regulator fixed on surface flush with wall, for One light point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge. |
| 190 | All as per serial item 183.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge. |
| 191 | All as per serial item No 183.00 here-in-before but for one socket outlet 3/ 5 pin, 5 Amps on independent board complete all as specified and as directed by Engineer-in-Charge. |
| 192 | All as per serial item 183.00 here-in-before but for One bell/ buzzer point controlled by one bell push complete all as specified and as directed by Engineer-in-Charge. |
| 193 | All as per serial item 183.00 here-in-before but for One light point controlled by two, 2-way switches complete all as specified and as directed by Engineer-in-Charge. |
| 194 | All as per Serial item No 183.00 here-in-before but for one socket outlet 3/5 pin, 15 Amps on independent board size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge. |
| 195 | All as per Serial item No 183.00 here-in-before but for one socket outlet 3/5 pin, 15 Amps on independent board size of cable 4.0 sqmm for phase, neutral & 4.0 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge. |
| 196 | NOTE for serial item No 183.00 to 189.00:(i) Colour code of wiring should be Red- for phase, Black- for neutral and Green- for earth wire.(ii) The quoted rate shall deemed to include the cost of metal flush boxes, frames, modular white with inner and outer cover plate, provision of blank plates as per site requirement etc.(iii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing.(iv)Instruction for point wiring to be followed/ compiled strictly as per Para 1 (a) to (q), Srl Page No 437 of SSR Part-II of 2020. |
| 197 | S&F modular switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge. |
| 198 | S&F modular switch, two way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge. |
| 199 | S&F modular switch, one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge. |
| 200 | S&F Modular socket outlet, 2 in 1, 3 pin 6 Amps, single pole, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 201 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole, two module, 6/16 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 202 | S&F Modular bell push, single pole, one module, 6 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 203 | S&F Blank Plate, one module, complete all as specified and as directed by Engineer-in-Charge. |
| 204 | S&F Modular fan step regulator, 120 watts, 2 module complete all as specified and as directed by Engineer-in-Charge. |
| 205 | S&F Ceiling rose 3 pin, 230 volts, PVC polycarbonate insulated body complete all as specified and as directed by Engineer-in-Charge. |
| 206 | Supply and fixing door bell, ding dong type, 240 volts, AC complete all as specified and as directed by Engineer-in-charge. |
| 207 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge. |
| 208 | Supply and fixing LED Bulb, 9 Watt, ISI Marked complete all as specified and as directed by Engineer-in-Charge. |
| 209 | Supply and fixing 6/16 Power adapter with in built RCD, 250V, AC, 50 HZ, 30 mA Residual current trip level complete all as specified and as directed by Engineer-in-Charge. |
| 210 | Supply and fixing LED light fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light and connecting up with and including three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge. |
| 211 | Supply and fixing LED light fitting, mirror type with high output diffuser, 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp and connecting up with and including three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 212 | S&F LED light fitting, 1 x 9W/ 1 x 10W bulkhead luminaires including LED light driver holder andconnecting up with and including three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 213 | Supply & fixing ceiling mounted, slim design, recessed LED downlight, round shape with superior light output and internal driver, 12 watts, 230 volts, internally pre-wired and connecting up with and including two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge. |
| 214 | S&F security light mounting bracket made out of 40 mm bore GI \"Light grade\" pipe 1.50 Metre long bent to required shape as in bracket for street light fittings fixed with two pair of MS flat iron clamp of size 40 mm X 5 mm thickness of required shape with nuts, bolts and washers of suitable size and fixed to steel tubular pole including painting of bracket surface with two coats of aliminium paint over a coat of primer including taking out existing unserviceable rusted GI bracket complete all as specified and as directed by Engineer-in-Charge. |
| 215 | Supply and fixing LED building security/ street light fitting 35 Watt, 230 V AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver having secondary lens, PF>0.90, lumen efficacy> 110 lumen/watt lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and as directed by Engineer-in-charge. |
| 216 | Taking down carefully copper/ aluminium sub main wiring complete, including existing batten/ conduit etc. removing materials deposited in store for keeping in safe custody and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed by Engineer-in-charge. |
| 217 | Supply and fix Sub main wiring with Two runs of 6.0 sqmm, single core, FRLS PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including non metallic PVC conduit (Concealed) of appropriate dia with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FRLS PVC insulated & unsheathed copper conductor as continous earth wire dolly and connecting to existing main switch board/ distribution board including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and as directed by Engineer-in-charge. |
| 218 | Supply and fix Sub main wiring with Two runs of 10.0 sqmm, single core, FRLS PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including non metallic PVC conduit (Concealed) of appropriate dia with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10.0 sqmm single core FRLS PVC insulated & unsheathed copper conductor as continous earth wire dolly and connecting to existing main switch board/ distribution board including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and as directed by Engineer-in-charge. |
| 219 | Note: 1. Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length.2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately.3. Earth wire shall run inside the conduit pipe. |
| 220 | Supply and fixing Sub main wiring with four runs of 10.0 sqmm, single core, FRLS PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including non metallic PVC conduit (Concealed) of appropriate dia with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10.0 sqmm single core FRLS PVC insulated & unsheathed copper conductor as continous earth wire dolly and connecting to existing main switch board/ distribution board including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and as directed by Engineer-in-charge. |
| 221 | Note: 1. Four runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length.2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe. |
| 222 | M&L for Making of circular hole suitable for passing of 150 mm dia pipe for chimney vent in stone masonry/ Brick wall and making good the existing surface complete all as specified and as directed by Engineer-in-charge. |
| 223 | Supply and fixing stainless steel electric kitchen chimney, 60 cm with 1500 cum/hour suction with, intelligent auto clean, filter less, revolutionary motion senser control, oil collector tray, BLDC Motor with inbuilt LED light including aluminium flexible pipe of diameter 150 mm upto 20 feet long (after expansion) with all accessories including clampsall as specified and directed by Engineer-in-charge. |
| 224 | M&L for Making of square/ circular hole 350 mm in the stone masonry/ Brick wall suitable for fixing exhaust fan of 200/ 300 mm sweep including M.S Frame work of suitable size with nut, bolts etc. and making good the existing surface complete all as specified and as directed by Engineer-in-charge. |
| 225 | Taking down exhaust fan of any size complete with nut and bolts and deposit to MES Store yard complete all as specified and as directed by Engineer-in-Charge. |
| 226 | Supply and fixing Exhaust fan, steel body, AC single Phase. 230V of size 300 mm sweep with 950 RPM, blades, frame and louvers etc., fixed with nut and bolts complete all as specified and as directed by Engineer-in-charge. |
| 227 | Supply and fixing exhaust fan, made of sturdy Engineering plastic complete with louvers shutters, voltage 230V, 50 Hz, RPM 1200, with Copper winding of sweep 200 mm complete all as specified and as directed by engineer-in-charge. |
| 228 | Supply and fixing exhaust fan, made of sturdy Engineering plastic complete with louvers shutters, voltage 230V, 50 Hz, RPM 1200, with Copper winding of sweep 250 mm complete all as specified and as directed by engineer-in-charge. |
| 229 | S&F in replacement of Vertical Distribution Board, iron clad, double door with IP-43 IK-09 protection suitablefor MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/S, 4 way, complete with appropriate size copper bus bar and neutral link complete with and including one MCCB, 4 pole, 415 Volts, 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and as directed by Engr-in-Charge. (For JCOs & ORs Block) |
| 230 | S&F in replacement of Vertical Distribution Board, iron clad, double door with IP-43 IK-09 protection suitablefor MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/S, 4 way, complete with appropriate size copper bus bar and neutral link complete with and including one MCCB, 4 pole, 415 Volts, 125 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and as directed by Engr-in-Charge. (For Offrs Block) |
| 231 | S&F sheet metal enclosures for MCB DB, TPN, 415 volts, 6 way, vertical type, double door fitted with 200 Amps bus bar, neutral link, earth bar and din rail complete all as specified and as directed by engineer-in-charge. |
| 232 | S&F sheet metal enclosures for MCB DB, SPN, 240 volts, 12 way, double door fitted with 200 amps bus bar, neutral link, earth bar and din rail complete all as specified and as directed by engineer-in-charge. |
| 233 | Supply and fixing MCB, TPN, 63 Amp, 415V, 10KA \"C\" curve miniature circuit breaker (MCB) complete with connection, testing complete all as specified and as directed by Engineer-in-charge. |
| 234 | Supply and fixing MCB 40 Amp, SP, \"C\" series, 10 KA, 240 Volts complete all as specified and as directed by Engineer-in-charge. |
| 235 | S&F RCBO \"A\" type (SPN-2M) 40 Amp, 30 mA (in accordance with IS-12640-2 & IEC 61009-1) 240V/ 415V, 50 Hz with 10 kA short circuit capacity all as specified and as directed by Engineer-in-charge. |
| 236 | Supply and fixing MCB 6-32 Amp, SP, \"C\" series, 10 KA, 240 Volts complete all as specified and as directed by Engineer-in-charge. |
| 237 | Taking out carefully old/ unserviceable LT UG cable of any type/ size from trenches/ pole/ duct after disconnecting from Ple/ busbar complete all as specified and as directed by Engineer-in-charge. |
| 238 | Supply, laying & testing of XLPE insulated, armoured, heavy duty LT cable, with stranded aluminium conductor, 1100 volts grade, of size 25 sqmm, 4 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointingwith suitable size aluminium lugs complete all as specified and directed by Engineer-in-Charge. |
| 239 | Supply, laying & testing of XLPE insulated, armoured, heavy duty LT cable, with stranded aluminium conductor, 1100 volts grade, of size 50 sqmm, 3.5core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointingwith suitable size aluminium lugs complete all as specified and directed by Engineer-in-Charge. |
| 240 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth, getting out in soft/ loose soil for laying of cable etc complete all as specified and as directed by Engineer-in-charge. |
| 241 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick, filling back in trenches after cables have been laid and tested, complete all as specified and as directed by Engineer-in-Charge. |
| 242 | Removing of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above starting point complete all as specified and as directed by Engineer-in-Charge. |
| 243 | Supply & laying un-reinforced pre cast concrete cable covers class LV, type-1,flat,of size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engineer-in-Charge. |
| 244 | M&L for Sand cushioning to UG cable 8cm thick before laying the cable and 15cm above the under ground cable including punning down of sand in layer all as specified in SSR complete all as specified and as directed by Engineer-in-charge.Note:(i) Consolidated/ Punned sand thickness shall be considered for purpose of payment. |
| 245 | Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm, surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 metre deep below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, connected with and including galvanised iron or steel earth wire, 4 mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (medium grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25, reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all asspecified and directed by Engineer-in-Charge. |
| 246 | Note : The unit rate includes for protecton pipe 15 mm and GI wire 4 mm dia from top of earth plate upto 7.50 metre. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail