| 1 | Demolition of cement concrete in roofinc existing roof treatement(other than ground floor) and including old treatment and description in any position, removing debris to a distance of n.exc 100M away from the bldg complete all as specified and directed.. |
| 2 | M & L for25 mm average thick PCC (1:2:4) Type B0 by using12.50 mm graded stone aggregate as in roofwhere required over slabsand finishing the exposed surfaces faireven without using extra cement complete all as specified and directed. |
| 3 | M&L for removal of old treatment of any description and removing the debris roughening the surfaces of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 4 | M & L 10mm thick rendering in CM 1:4 using water proofing compound at the rate of 3% weight of cement over concrete surfacescomplete all as specified and directed. ( Note : WPC measured and paid separately) |
| 5 | M&L priming the plastered roof surfaces with bitumenous primer @ 0.30 Kg per sqm and applying APP based polymeric membrane minimum weighing 3 Kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Wt not less than 150 gms/per Sqm) and on primed surface by forced applicationover apply bitumen base aluminium paint@ 0.20 Kg/Sqm complete all as specified. |
| 6 | Supply only water proofing compound |
| 7 | M & Lcutting grooves in brick wall/roof slab of size 75mm wide 65mm deep and shapping to horizontal face of the groove with cement mortar 1:3 complete all as specified and directed. |
| 8 | Taking down rain water pipes of any description any pattern incl all fittings heads, shoes bends etc all as specified. |
| 9 | S&F PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls all as specified. |
| 10 | Dismanting asbests cement /steel sheet ( corrugated, semi-currugated etc.) sheets in roof covering complete all as specified and directed. |
| 11 | Dismanting single layer mangalore pattern or similar tiles in roofing complete all as specified and directed. |
| 12 | Removal of Battens for spacing N exc 15 cm tiles, shingles, etc of any size including tilting fillets complete all as specified and directed. |
| 13 | S & F prepainted galvalume aluminium zink coating GI based corrugated steel sheeting 0.5mm thick of any colour having tensile stength of 550 MPAasin roof covering/cladding to wall fixed with self tapping screws as specified. |
| 14 | S&F pre painted gal valume aluminium zink coating GI based plain steel sheeting 0.5mm thick of any colour haing tensile strenghth of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws as specified |
| 15 | Dismantlingframed wooden purlin/Rafterwork of any descriptionsectional area exc 40 Sqcm not other wise provided for, complete all as specified and directed. |
| 16 | Dismantlingframed wooden purlin/Rafterwork of any descriptionsectional area n exc 40 Sqcm not other wise provided for, complete all as specified and directed. |
| 17 | S & F roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc confirming to grade Fe-410 W E250 quality A. |
| 18 | M & Lproviding cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed. |
| 19 | M&L Preparatioin of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat primer. all as specified & directed. |
| 20 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etcall as specified and as directed. . |
| 21 | M & L for brick work with old bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6all as specified and as directed. |
| 22 | Taking down plastering on brick walls etc including racking out joints, hacking for key, scrabing down with water etc.complete all as specified and directed. |
| 23 | M & L for 15 mm thick (inner 10mm layer 1:6 and outer 5mm layer 1:4) rendering in Cement Mortar on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement and using water proofing compound for outer 5mm layer complete all as specified and directed incl scaffolding if necessary. Note : Patch work upto height 10.00m incl necessary scaffolding. (WPC will be measured and paid separately) |
| 24 | M & L for 15 mm thick rendering in Cement Mortar 1:6 on fair faces of Brick works or Concrete surfaces and finishing even and fair without using extra cement. complete all as specified and directed. |
| 25 | M & L for 10 mm thick rendering in Cement Mortar 1:3 on fair faces of Brick works or Concrete surfaces in ceilings and finishing even and fair without using extra cement. complete all as specified and directed. Note : Roof projection/sun shade portion upto ht 7.50m incl necessary scaffolding |
| 26 | M&L for preparation of new surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engr in Charge |
| 27 | M&L for two coats of OBD over a coat of primer including preparation of new plastered surfaces of walls all as specified and directed |
| 28 | M&L for two coats of OBD over a coat of primer including preparation of new plasted ceiling all as specified and directed |
| 29 | M&L Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 30 | M&L Complete removal of existing treatment on ceilings and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 31 | M&L Complete removal of existing treatment on walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 32 | M&L for providing false ceiling with anodised aluminium snap grid frame work for false ceiling with size of grid 605 x 605mm with aluminium main tee, cross tee size 25x25x1.6 mmand aluminium wall angle size 25x25x1.8 mmfixed to wall hanging from soffits\trusses\bracking using adjustable supportinghanger compressing of GI wire 4mm thick with locking clip.complete all as sepcified and directed by Engr-In-Charge. |
| 33 | M&L for Providing and fixing Non asbestos designer E-Board 4mm thick in ceiling fixed to snap gridas per manufacturers instructions complete all as sepcified and directed by Engr-In-Charge. |
| 34 | Taking down chowkat with frame (without taking off shutter from the frame) exc 1.50 Sqm each complete all as specified & directed. |
| 35 | Taking down shutter of any description not exc 1 Sqm each complete all as specifiedcomplete all as specified & directed. |
| 36 | Taking down shutter of any description exc 1 Sqm & n exc 2 Sqm each complete all as specifiedcomplete all as specified & directed. |
| 37 | M&L for plain cement concrete type C-1 1:3:6 (20mm graded aggregate) for setting hold fasts, steel windows all as specified and directed. |
| 38 | S&F bands, straps, supports or stays for rain water, ventilating pipes including bolts if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasta, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles confirming to Fe-290 Gde E-165 |
| 39 | M & L for 2nd classhard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints |
| 40 | M & L for preparation of new wood and wood based materials, like backs of chowkhats and tarred with tar or coal tar black paint, area tarred exc 0.1 sqm but n exc 0.5 sqm surface and complete all as specified. |
| 41 | M & L for treating small articles such as stop, covers, holdfasts, with tar or coal tar black paint area tarred n exc 0.1 sqm complete all as specified. |
| 42 | S&F for 35mm thick factory made plain framed paneled shutter of 2nd class HW (any Number of panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm th venered particle board with veneering on both face kiln seasoned & chemically treated complete all as specified & directed. |
| 43 | S & F 35mm thick 2nd class hard wood glazed skeleton door shutters open rebated and prepared to receive glass, gauze, etc (without sah bars) and divided into square with plain, rounded, chamfered, mitred complete all as specified & directed. |
| 44 | S & F 35mm thick 2nd class hard wood glazed skeleton windows shutters open rebated and prepared to receive glass, gauze, etc (with sash bars) and divided into square with plain, rounded, chamfered, mitred and rebated sash bars.complete all as specified & directed. |
| 45 | S & F 125mm butt hinges heavy weight cold rolled mild steel complete all as specified & directed. |
| 46 | S & F in repairs 125mm butt hinges heavy weight cold rolled mild steel complete all as specified & directed. |
| 47 | S & F Aluminium handle 150mm fabricated type complete all as specified & directed. |
| 48 | S & F in repairs Aluminium handle 150mm fabricated type complete all as specified & directed. |
| 49 | S & FAluminium anodised barrel tower bolts 200mmof extrded section complete all as specified & directed. |
| 50 | S & Fin repairs Aluminium anodised barrel tower bolts 200mmof extrded section complete all as specified & directed. |
| 51 | S & FAluminium anodised barrel tower bolts 300mmof extrded section complete all as specified & directed. |
| 52 | S & Fin repairs Aluminium anodised barrel tower bolts 300mmof extrded section complete all as specified & directed. |
| 53 | S & F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed |
| 54 | S & F in repairs 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed |
| 55 | S&F 300 mm long helical door springs including roller plate complete all as specified & directed. |
| 56 | S& F for 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor |
| 57 | S& F in repairs for 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor |
| 58 | S &Ffor framed work such as grills, grating etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars(for windows); barred iron doors; ladders; framed balusters; walk ways; railings; framework of watertanks and similar work cnforming to Fe 290. Gde E-165 |
| 59 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and avg width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. |
| 60 | All as per item 59 above but fixed in repairs complete all as specified & directed.. |
| 61 | S & F 2nd classhardwod in fillets, square, rectanglar in section wrought, secrred with nails sectional area exc 3 sqcmand n exc 6 sqcm fixedin repairs. |
| 62 | S & F 2nd classhardwod in fillets, square, rectanglar in section wrought, secrred with nails sectional area exc 13 sqcmand n exc 25 sqcm |
| 63 | Hacking out old broken glass any description & size from wooden/steel window and removal of rubbish from work site as directed. |
| 64 | S & F 4mm th sheet glass ordinary quality and fixed with oil putty in square not exc 0.5 sqm in each panecomplete all as specified & directed. |
| 65 | S & F 5.5mm th sheet glass ordinary quality and fixed with oil putty in square exc 0.5 sqm in each panecomplete all as specified & directed. |
| 66 | M & L for preparation of new wooden surface and applying 2 coats of synthetic enamel paint over one coat of pink primer over 10cm width or girth complete all as specified. |
| 67 | M & L for preparation of old wooden surface and applying two coats of synthetic enamel paint over 10cm width or girth complete all as specified. |
| 68 | Demolition of cement concrete(unreinforced) in ground floors and pavingnexc 15 cm thickness (below and above ground level) complete all as specified & directed. |
| 69 | M & L75 mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection finished even and smooth without using extra cement. |
| 70 | M&L forming 38mm wide construction joints Glass dividing strips, 3 mm thick complete |
| 71 | M&L for removing plants incl complete root in wall and roof, also repair and finish with PCC (1:3:6) using 20mm graded aggregatefinished to existing surface upto height of 7.5m all as specified and directed. |
| 72 | S&F 25mm Stainless steel curtain rods incl required nos ofbrackets complete all as sepcified and directed by Engr-In-Charge. |
| 73 | Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar |
| 74 | S&F 18-20 mm thick kota stone as in floors over and including 15mm thickscreed bed or bedding layer in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish and rounding chamfered edges where directed complete all as specified and diirected. |
| 75 | All as per item above but 16 to 18m thck kotastone slabas in small wiidth in vertical surfaces likelandings, risers,, treads, skirtings,dado, etc over and including 10mm thick pcking coat in cement mortar 1:4 complete all as specified and directed. |
| 76 | Mirror polishing on Kota stone/stone workwhere ever required to give high gloss finish complete all as specified and directed. |
| 77 | Surface excavation n exc 30 cm deep and averaging 15 cmm deep and getting out hard/dense soil |
| 78 | Removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 79 | M&L broken stone or boulder hard core of gauge exc63 mm but n exc 100mm deposited spread and levelled in layers n,exc 15 cm thick watered and rammed to true surface |
| 80 | M&L for 100 mm thick PCC 1:4:8 type D2 (40mm graded aggregate) as in sub bases, sub flooring finished even and rough. |
| 81 | M&L for chequered cement concrete tiles with grey cement and pigments of size 300cmx300cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1:6 screed bed in flooring complete all as specified & directed. |
| 82 | S&F Vertical looking mirror of size 48cm x 120cm to fixed in verandah of barracks including necessary bolts and fittings all as specifed and directed by Engineer-in-Charge |
| 83 | S&F 4mm Plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hook eyes, etc all as specified and directed |
| 84 | S&F Bulletin/Pin-in/Notice board (Green, Maroon or Blue) of size 120cm x 90cm (4\"x3\") to be fixed in verandah of barracks including necessary bolts and fittings all as specified and directed by Engineer-in-Charge |
| 85 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards/sockets/regulators of any size modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for the following:-(a)one light/fan point controlled by one switch.Note : (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting & chasesrequired width and depth for concealled conduit including PCC plastering,POP putty, making good to disturbed surface, distemper painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor.(3) Three runs wire & one run of PVC conduit,metal Sunken box, modualr frames & connected accessories shall be measured as one point |
| 86 | (b) One three pin switch socket 6 Amps outlet on independent board. |
| 87 | (c) One three pin switch socket 6 Amps outlet on same board. |
| 88 | All as per item No 85here in before but with cable 4 sqmm multi stranded copper FR-LSH wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 4 sqmm copper stranded conductor FR-LSH, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and as directed. |
| 89 | Supply and fix Modular switch 1 way 6A , 1-module all as specified and directed. |
| 90 | Supply and fix Modular switch 1 way 16A with indicator, 1-module all as specified and directed. |
| 91 | Supply and fix Modular socket, shuttered type, 6A - 3 pin 2 -module all as specified and as directed |
| 92 | Supply and fix Modular socket, shuttered type, 6/16A -combined 2-module all as specified and as directed. |
| 93 | S & F 3 pin, 6 A, 250 V ceiling rose conforming to IS 371: 1999 and having terminal capacity 3 X 1.5 mm² with IK 04 and IP 20 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. |
| 94 | S & F sheet metal enclosure MCB DBSPN 12 way double doorwith 100 ampsrated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed . |
| 95 | All as per Item above but triple pole & neutral double door, 6 ways with MCCB as incomer complete all as specified and as directed |
| 96 | S & F MCB (\"C\" curve) 6- 32 A, 230 V, 50 Hz, SP for conforming to IS/IEC 60898-1-2002, having breaking capacity 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. with the following rating complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. |
| 97 | S & F MCBfor earth leakage, overload & short- circuit protection 6-32 A, 230 V, 50 Hz, 2P, 100 mA rating complete all as specified in IS 12640-1 (2008) and directed by the engineer-in-charge. |
| 98 | S & F MCCB, 415 V, 16KA, 4 Pole, 100 Amp complete all as specified and as directed |
| 99 | M & L for submain wiring using 3 runs of 6 Sq mm 1100 V grade single core FR-LSH flexible cable conforming to IS 694: 2010, with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/surface / ceiling including continous earth wire having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade PVC recessed conduits of size not less than 25 mm , including making good of disturbed surfaces of wall / ceiling / floor all complete as specified and directed by engineer-in-charge. |
| 100 | M & L for submain wiring using 3 runs of 1.5 Sq mm 1100 V grade single core FR-LSH flexible cable conforming to IS 694: 2010, with ISI marking in and including PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/surface / ceiling including continous earth wire having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade PVC recessed conduits of size not less than 25 mm , including making good of disturbed surfaces of wall / ceiling / floor all complete as specified and directed by engineer-in-charge. |
| 101 | Supply and fixing ceiling fans complete with blades,copper winding, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery not less than 210 CFM with service value more than equal to (≥)6.00, BEE Five star rated with brushless direct current motor (BLDC) white colour and marking of MES number on ceiling fan by stamping with ink print oflettering frame size Length 20cm, width 2.5 cm at least two sides on fan complete all as specified and directed by the engineer-in-charge. Make:Gold Medal cat part no.SCFS 500748/Bajaj Cat part No:ENERGOS 28/ Crompton Cat part No:ENERGION RIVIRA/Havells Cat part No:PRO 28BLDC/Luker Cat part No:ECO28NEOBLDC Regulator 230cmm/Orient Cat Part No:Hector 500-230CMM/Polar Cat part No:PS-32 |
| 102 | S & F Electronic type fan regulator stepped socket type, suitable to work on 230 volts complete all as specified and as directed |
| 103 | S & F TV CO-Axial socket outlet fixed to wall on hylem sheet complete all as specified and as directed. |
| 104 | S & F Rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed. |
| 105 | S & F 20 W surface / wall mountedLED batten light fitting aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge.Make: Crompton CCS-100-20-65-HSL2-DP-NWH/ PHILIPS BN308CLED20S-6500L120PSUWH / WIPRO LL31-251-XXX-65AL5/Havells ENDURALINEARPROBS20WLED865PCSSIND/Bajaj-BCLAB20WCWLEDXT |
| 106 | Refixing of exisitng serviceable LED tube light fittings of any type and capcity complete all as specified and directed by the engineer-in-charge. |
| 107 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings suitable for B22 type LED bulb complete all as specified and as directed. |
| 108 | S & F 15 Watt LED Bulb 3 star rated efficacy not less than 100 Lumen/watts,rated life 25000 burning hours complete all as specified and as directed. |
| 109 | S&F wall mounted flexible rotary typebed side reading lamp of capacity not more than 10 watts including necessary electric connection complete all as specified and directed by E-In -Charge . Make: Syska cat Part No:SSK-TRS 6W/Shakti cat Part No:SZWRFPX003/Havell cat Part No:LHEXCIPBPN1K004/Fortune arrt cat Part No:TSR10/8/Luker cat Part No:LSP07NBK |
| 110 | S & F recess mounting LED down light fitting 2\" x 2\" of capacity 36 Watts powder coated white CRCA full glow,efficacy 120 lumen/watts rated life 50000 burning hours suitable for false ceiling pop/grid ceilingincluding making electrical connection from ceiling rose to light fitting complete all as specified and as directed by E-In-Charge .Make:Crompton: LCTLRP-36-FO-CDL / PHILIPS RC308LED36S6500 / HAVELLS VENUSEXL2X2PLR36WLED865SWH/WIPRO-CRCO10R036HE57G4/Bajaj-BZRSQL43LXEWHODSD |
| 111 | S&F Desert cooler ISI marked of following specifications complete all as specified and directed by E-In-Charge.(i)Air drluvery Capacity: Not less than 5000 CMH(ii)Cooling media : Honey comb(iii)Speed control: 3 step speed control Knob for power ful motor(iv)Water tank capacity: 100 Ltrs(v)Material: PVC body/Metal as per OEM (vi)Air through distance: Not less than 20 Mtrs(vii)Power : Single phase,230 V & 50 Hz(viii)Mounting: Lockable castorWheel(ix)Float valve: Yes(x)Vertical swing: As per OEM(xi)Water level indicator: Yes(xii)Submersible pump: Yes(xiii)Auto drain vent: Yes(xiv)Motor speed : As per OEMmarking of MES number on ceiling fan by stamping with ink print oflettering frame size Length 20cm width 2.5 cm at least two sides on water coolerMake: Crompton-OPTIMUS 100 /Symphony-MOVI COOL L125/Bajaj-X Force 100 |
| 112 | Supply and fixing LED security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect as specified and directed by engineer-in-charge.complete in all respect as specified and directed by engineer-in-charge.Make:Crompton TRP-409-45-57-SL-GL-NSG / PHILIPS BRP331LED48CWR5NPCPSUS1V1 / HAVELLS ENDURASUNDOWNSL45WLED765PASYBOPC/WIPRO LR22-501-XXX-57-XX/Bajaj-VISTAP45LWHPOPCSD |
| 113 | Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less\" than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete all as specified and as directed. |
| 114 | S & F Telephone socket outlet fixed to wall on hylem sheet complete all as specified and directed. |
| 115 | M & L for taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |