| 1 | Surface excavation (not exceeding 30cm deep)and averaging 15 cm , getting out in any type of soil complete all as specified and as directed by Engineer-in-charge. |
| 2 | Excavation in trenches for foundation etc not exc 1.5m wide and not exc 1.5 m in depth in any type of soil complete all as specified and as directed by Engineer-in-charge. |
| 3 | Excavation in post holes (or similar holes) each nexc 0.5 cum getting out returning filling in and ramming earth or broken stone boulders mixed with boulders |
| 4 | Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Removal ofexcavated material to a distance nexc 50 m and depositing at a level nexc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 6 | M&L forbroken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surfacecomplete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foudation, filling, sub baseand mass concrete complete all as specified and as directed by Engineer-in-Charge. |
| 8 | S&F for steel work in tubular section as in trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS- 1161-1979 graded St 240complete all as specified and as directed by Engineer-in-Charge. |
| 9 | S&F for mild steel work as in plates / flats angles etc as in cleats drilling welding etccomplete all as specified and as directed by Engineer-in-Charge. |
| 10 | S&F Mild steel bolts.exc. 5 cm lengthnot exc. 10 cm length (machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fittied with washers and one hexagonal or square nut 11 to 15 mm neck dia complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in ement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 12 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished smooth and even without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 13 | S&F forpre painted galvalume aluminium zinc cozting GI based corrugated steel Sheethigh rib profile tile pattern of slaty color coated 0.50 mm thick of 550 Mpa Tensile strength sheets as in roof covering and fixed as per manufacturers instruction (design as app by complete all as specified and as directed by Engineer-in-Charge. ) |
| 14 | S&F of Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M&L for 100 mm thick cement concrete type B-1 ,1:2:4 (20 mm graded aggregate) laid to alternate pannels and making surface even and fair complete all as specified and as directed by Engineer-in-Charge. |
| 16 | S&F of Plastic dividing strips, 1.5mm thick and 38mm width inserted in position,conform to design complete all as specified and as directed by Engineer-in-Charge. |
| 17 | M&L for preparing new plastered surfaces and applyingtwo coats of cement base paint over one coat of Chalk whiting, on plastered surfaces of walls complete all as specified and as directed by Engineer-in-Charge. |
| 18 | M&L for two coats of synthetic enamel paint on new steel surfaces including preparation over a coat of red oxide Zinc chrome primer complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Surface dressing n.exe. 15cm deep and getting out(soft/loose soil) complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in soft & loose soil complete all as specified and as directed by Engineer-in-Charge. |
| 21 | S&F Mild steel bolts.exc. 5 cm lengthnot exc. 10 cm length (machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fittied with washers and one hexagonal or square nut 5 to 10 mm neck dia complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L for preparing new or previously untreated steel and iron surface of any description over 10cm in width or girth and applying two coats of synthetic enamelpaint over & including a coat ofred oxide zinc chromeprimer complete.as specified as Eng in charge. |
| 23 | M&L for 15mm thick Renderingin cement mortar 1: 4 on other than fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement as complete as specified per manufacturer instruction all as specified. |
| 24 | M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint overa coat of primer as per manufacturer\"s instructions complete all as specified and as directed by Engineer-in-Charge. |
| 25 | M&L for sand filling under floors, cushning under interlocking tiles or in foundations incl watering and consolidations complete all as specified and directed. |
| 26 | M&L 60 mm thick machine pressed precast concrete interlocking paver blockany shape and size of grade M-35confirming to IS 15658-2006 with grey cement and no pigmentlaid over sand cushioning complete all as specified and as directed by Engineer-in-Charge. |
| 27 | M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colourto coomon earth dolly laid/drawn into and includingnon metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in& including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed:Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE |
| 28 | One light controlled by oneswitch |
| 29 | One 5/6 amp socket outlet on the same boardcontrolled by another switch. |
| 30 | S&F switch Modular type, 5/6 Amp, 1 module single pole one way, 230 Volts, Modulartype complete all as specified and as directed by Engr- in -charge. |
| 31 | S&F socket outlet 3 Pin5/6 Amps modular type, 2/3 pin combined 2 module230 Voltscomplete all as specified and directed by Engr-in-Charge. |
| 32 | S&F LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 33 | S&FLED Bldg Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 34 | S&F GI bracket made out of 40 mm bore GI pipe light grade /medume grade, ISI marked, medium grade 1.2m long bent to shape suitable for fixing of street light fitting including with 2 Nos MS clamps made with 40x3mm flat iron, bolts, nuts, washers etc including two coats of synthetic enamel paint over one coat of zinc chrome primer and fixing on electric pole complete all as specified and as directed by Engr-in-Charge. |
| 35 | S&Fdouble door, sheet metal enclosure,powder coated for MCB DB SPN 8 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. |
| 36 | S&FMCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 37 | S&FMCB SPN, 5-32 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 38 | Earthing complete with galvanised steel pipe electrode, 32mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 6mm dia galvanised iron or steel wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion. |
| 39 | M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colourto coomon earth dolly laid/drawn into and includingnon metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in& including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed:Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE |
| 40 | One Light/fan/Ex-fan point controlled by one switch. |
| 41 | One 3pin 5 amps socket point on the same board complete |
| 42 | S&F ceiling rose, surface backelite , three terminal AC, 230 voltcomplete all as specified and as directed by Engineer-in-Charge. |
| 43 | S & F double door, sheet metal enclosure,powder coated for MCB DB SPN 4 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. |
| 44 | M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion. |
| 45 | Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m width for laying of cable lines etc and getting out in hard/ dense soil complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed by Engineer-in-Charge. |
| 47 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge. |
| 48 | Supply and Laying Double wall corrugated pipe(DWC pipe, Specification-120 mm OD/103 mm ID) for laying XLPE LT UG cable by DWC pipe throughout the LT cable length in pieces of convenient lenth .(Note : in pieces for easy rectification during fault ). |
| 49 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 2 core complete all as specified and as directed by Engineer-in-Charge. |
| 50 | S&F GI Pipe light grade og Size 40 mm bore with all fittings for passing of cables fixed to pole/wall/laid under floor or roads including all fixing accessories complete for protection of cable all as specified and directed. Make: Jindal/ Bansl/Tata |
| 51 | Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 02 core x 10 Sqmm complete all as specifed and as directed. Make : Polycab/KEI/HavellsNote: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and pad under appropriate items. |
| 52 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 65 protection made out of CRCA sheet3.15 mm thick powder coated with seven tank process, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with copper bus bar capacity 60 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- |
| 53 | (Proposed LT Panel)INCOMING :- (a)Supply and fix 4 Pole MCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA with Thermal megnatic relay adjustable type – 01 Nos OUTGOING :- (b) Supply and fix 4 Pole MCB 40 Amp, 50 Hz, 415 V with rupturing capacity 16 KA with Thermal megnatic relay adjustable type – 02 No(c) Digital Voltmeter with built in selector switch 0-500Volts -1No(d) Digital Ammeter with built in selector switch 0-50 amps with suitable CTs -1No(e) LED Indicated Lamp (R,Y,B) one Set-01Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Internal power and control wiring with suitable size PVC insulated multistranded copper wire. |