| 1 | Dismantling asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings complete all as specified and directed |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in roof covering/cladding to wall, ridge etc fixed with self tapping screws complete all nas specified. |
| 4 | Dismantling of wallandceilingboards(fibre, pulp, insulation etc) or insulationboards/slabs/ blankets, any thickness, including cover fillets or frame complete all as specified and directed |
| 5 | Supply & fixing false ceiling at all heights with GRG (Glass Fibre With SemiReinforced Gypsum) false ceiling tiles of perforated 12mm Size 595 x 595 mm of approved texture, 12mm thick thick micro tegular design and patterns having moisture micro tegular edged or 1 0 mm content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, complete all as specified and directed. |
| 6 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed |
| 7 | M&L for brick work with sub class \"B\" old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed |
| 8 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 9 | M&L for 15mm thick plaster in CM 1:4 on fair face ofwalls surface including preparation without using extra cement complete all as specified |
| 10 | M&L for 10mm thick plaster in CM 1:6 onfair face of brick work/old unplastered surface including preparation without using extra cement complete all as specified |
| 11 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces incl preparation of surface complete all as specified and directed. |
| 12 | M&L for preparation of newly plastered surface of internal walland applying two coats of oil bound distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. |
| 13 | Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 14 | S&F second class timber framed wrought and framed hard-wood clean sawn in scantlings complete all as specified and directed |
| 15 | M&L for Preparing surfaces of timber piles and diping in a hot mixture of tar and creosote inthe proportion of 20 kg coal tar pitch to 25 litres of creosote oil, for 4 mins complete all as specified and directed |
| 16 | Excavation in post hole (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in any type of soil complete all as specified and directed |
| 17 | M&L for cement concrete 1:3:6 type C2 (Using 40mm graded stone agrregate ) as in foundation of posts, railing and similar work complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge |
| 19 | S&Ffor Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 |
| 20 | S&F Rolled sections Fe 410-W (Gde E- 250) quality A as in main and cross beams hip and jack rafters purlins shwere connected to common rafter and running rails and guides for sliding doors fixed with angle cleats or other connecting plates all as specified and directed by Engr-in-Charge |
| 21 | M&L forpreparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge |
| 22 | Dismantling and taking down carefully sub-main wiring/service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified |
| 23 | Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLSH ) 1100 Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium gradesurface on wall along with 4 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected withmain earth dolly including cutting chasing and making good disturbed portionall as specified and directed. |
| 24 | M&L for sub-main wiring concealed / surface with two single core 6 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massionay including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete including taking out old sub main, all as specified and as directed by EIC. |
| 25 | Taking down carefully aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pedants, regulators, sockets, light fitting etc.. and making good the disturbed surfaces of walls/ floor etc matching with the existing surface all as specified and as directed by EIC. |
| 26 | Taking down carefully by unscrewing from ceiling roses, Light fittings for reuse at site, carrying to the store (To be measured only when found serviceable in all respect for reuse) |
| 27 | Taking down carefully by unscrewing of switch board multi points including switch /socketfor reuse at site & refixing the sameafter completethe B/R work , all as specified & directed |
| 28 | Taking down carefully by unscrewing of switch board indepent point for light & power sockets for reuse at site & refixing after complectig the B/R work , complete all as specified. |
| 29 | Material & Labour for following type Point Wiring controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and includingconcealed/ surface PVC conduitMS ,duly concealed to wall/floor or above false ceiling with fittings (ISI marked) not less than 20 mm dia(Colour coding of wires shall be Phase, neutral and earth wire all as specified ) sunken Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates).(a) One light/fan point controlled by one switch. |
| 30 | One 3 pin 5 Amps socket out let on same boardwith other switches, one wayswitch complete all specified and directed. |
| 31 | One 3 pin 5 Amps socket out let onindependent board controlled by one, one way switch complete all specified and directed . |
| 32 | All as per item No 29 abovebut with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point. |
| 33 | S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge. |
| 34 | Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz all as specified and directed by Engr- in-charge. |
| 35 | Supply and fixing switch modular , one-way 16Amps,1 module 240 Volts AC all as specified and directed by Engr- in-charge. |
| 36 | Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz all as specified and directed by Engr- in-charge. |
| 37 | Supply and fixingstepped type electronic modular fan regulator 120/280 V , 2 module ,100 Watt all as specified and as directed. |
| 38 | Supply and fixing LED luminaire 600 mm x 600 mm, 40 watts, 220 Volts, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size compete including taking dwon old UNSV light fitting all as specified. |
| 39 | Taking down ceiling fan from existing building and again refixing the same ceiling fan after oiling /greasing complete,connecting up including provision of cable flexible 3 core of suitable size wire from ceiling rose to connect fan. |
| 40 | Supply and fixing LED light fittings 1x20 watts, 220 Volts, AC, decorative box type with driver, holder including LEDtube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 41 | FIxingonly LED light fittings 1x20 watts or any other serviceable light fitting received against item No 5 including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 42 | M & L for 40 mm bore GI pipe (med grade) laid or fixed with wall for hanging of ceiling fan of 1200 mm sweep including necessary PCC work andMS clamp suitable for fancomplete all as specified and directed. |
| 43 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 44 | S&F in repair Switch piano flush type, single pole, one way, 230 Volts 15/16 Amps complete all as specified |
| 45 | S & F in repair switchpiano flushtype single pole one way 230 Volts 6 Amp complete all as directed. |
| 46 | S & F in repair socket outlet 3 pin , 230 Volts 5/6 Amps multipurpose 5 pin complete. |
| 47 | S&F in repair Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type IS: 1239-1988 marked with valid CML No complete all as specified. |
| 48 | S&Fin repair dimmer type regulator one module for ceiling fan 1200/1400 mm size230 volts. |
| 49 | S&Fin repair ceiling rose,three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified |
| 50 | FIxingonly ceiling rose,three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified |
| 51 | S&Fin repair modular metal flush box of thickness 1.2 mm and of 3 module including making good the disturbed surface as specified and directed by Engr in Charge. |
| 52 | S&Fin repairmetal box of thickness 1.2 mm and of size 8 x 10 inch including making good the disturbed surface as specified and directed by Engr in Charge. |
| 53 | S&Fin repair white hylam sheet of thickness 3 mm for mounting swithces sockets of size 9 x 6 inch. |
| 54 | S&Fin repair white hylam sheet of thickness 3 mm for mounting swithces sockets of size 9 x 11 inch. |
| 55 | Taking out of all type & size rusted unsvIron materialMS Flat with nut ,bolt and washer incl S type hook for fixing of Ceiling fan on Angle iron or MS Channel frame |