| 1 | S&F Closed bus bar chamber having three phase and neutral 25mmX5mm aluminium Busbar, properly insulated, Chamber size 12\"\"X8\", sheet gauge 1.6mm duly power coated with suitable aluminium earthing strip in full run 25mmX4mm including fixing and hanging arrangement from cealing. |
| 2 | Dismantling of overhaed open cable trey including cables, tubelight, MCB DB etc. from ceailing. |
| 3 | S&F Sheet metal enclosures 450mmX300mmX150mm for feeding three phase & Neutral Bas Bar, 96X96 mm digital Ampere meter with seclector switch, 96X96 mm digital Volt meter with selector switch, RYB Phase indicator, fixing arrangement for MCB\"s Triple pole and neutral, duly powder coated including copper wiring, cable gland and locking arrangement. |
| 4 | Taking down fan, cealing cable end, dismantaling blades and removing fan and blades to store. |
| 5 | Hanging only ceiling fan (M. D. Supply) and connecting up including provision of cable from ceiling rose and connection of fan regulator as per site requirement. |
| 6 | S&F MS heavy duty fan hook as per site requirement |
| 7 | Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick burried directly in ground connection using galvanised iron strip 25X4 mm as earth lead, construction, connection & testing of earth pit chamber including 20mm watering pipe, funnel, chamber cover, earth marking plate, excavation , return/refilling and making good surface as per IS standard. |
| 8 | S&F Industrial LED Tube Light 4 Feet fitting with detachable tube rod, 2X18/20 Watt, 220VAC with driver, holder including led tube light, refelectorconnecting up with two core flexible copper conductor cable of suitable size to MCB installed on 4-way DB at closed busbar chamber make : HPL, Crompton, Havells. |
| 9 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors,etc. |
| 10 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, incluiding fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors,etc. |
| 11 | Taking down by unscrewing from boards / outlet boxes fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. removing materials to store for keeping in safe custody and making good disturbed surfaces of walls, floors,etc. |
| 12 | Point wiring of one light point or one fan point controlled by one switch with PVC single core, sheathed copper conductor cable make : Polycab, finolax, gloster,KEI, Havells1.5 Sqr.mm size in PVC conduit pipe (M&L) |
| 13 | Point wiring of one 3 pin socket outlet 5 Amp on the same board with other switches with PVC single core, sheathed copper conductor cable make : Polycab, finolax, gloster,KEI, Havells 1.5 Sqr.mm size in PVC conduit pipe (M&L). |
| 14 | Switch Piano, flush type single pole, one way 5Amp (S&F) Make Havells, Anchor, Schneider, Legrand, L&T |
| 15 | Socket outlet 2 in 1, 3pin, 5Amps flush type (M&L) Make Havells, Anchor, Schneider, Legrand, L&T. |
| 16 | Ceiling rose, 3 Phase/ PVC/ Polycarbonate, isolated body (M&L) Make Havells, Anchor, Schneider, Legrand, L&T. |
| 17 | Point wiring of one 3 pin 15Amp socket outlet independent with PVC single core, sheathed copper conductor cable make : Polycab, finolax, gloster,KEI, Havells 4 Sqr.mm size in PVC conduit pipe (M&L) |
| 18 | Switch Piano, flush type single pole, one way 15Amp (S&F) Make Havells, Anchor, Schneider, Legrand, L&T. |
| 19 | Socket outlet 2 in 1, 3pin, 5 and 15 Amp. Flush type (M&L) Make Havells, Anchor, Schneider, Legrand, L&T. |
| 20 | PVC rectangular block size 250X200x50mm deep with 3 mm sunmica sheet (M&L). |
| 21 | PVC rectangular block size 175X100x50mm deep with 3 mm sunmica sheet (M&L). |
| 22 | Sheet metal enclosures Make : Siemens,Legrand, L&T, ABB, Hager for MCB\"s Triple pole and neutral 4 way,with 200Amp ratedB/Bar 415VAC Double door covering open space with MCB blanker including lugging, glanding and connection etc. (S&F). |
| 23 | Sheet metal enclosures Make : Siemens,Legrand, L&T, ABB, Hager for MCB\"s single pole & neutral 8 way,with 200Amp ratedB/Bar 240VAC Double door covering open space with MCB blanker (S&F). |
| 24 | S&F of Sheet metal enclosures Make : Siemens,Legrand, L&T, ABB, Hager for MCB\"s single pole & neutral 4 way,with 200Amp ratedB/Bar 240VAC Sigle door covering open space with MCB blanker. 4 way DB must be fitted in overhead busbar or wall as required. Three phase and neutral must be connected with 4 way DB with 4.0sqmm copper conductor wires. |
| 25 | Supplyand fixing 415V, 10KA \"C\" curve miniature circuit breaker (MCB) Make : Siemens,Legrand, L&T, ABB, Hager of TP 06 AMP current carrying capacity, in the MCB DB complete with connection testing and commissioning. |
| 26 | Supplyand fixing 415V, 10KA \"C\" curve miniature circuit breaker (MCB) Make : Siemens,Legrand, L&T, ABB, Hager of TPN 40 to 100 AMP current carrying capacity, in the MCB DB complete with connection testing and commissioning. |
| 27 | Supplyand fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) Make : Siemens,Legrand, L&T, ABB, Hager of SPN 40 to 63 AMP current carrying capacity, in the MCB DB complete with connection testing and commissioning. |
| 28 | Supplyand fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) Make : Siemens,Legrand, L&T, ABB, Hager of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection testing and commissioning |
| 29 | Wiring for circuit / submain wiring along with earth wire with 2X2.5 sqmm +1X1.5 sq. mm FR PVC insulated copper conductor single core make : Polycab, finolax, gloster,KEI, Havells |
| 30 | Wiring for circuit / submain wiring along with earth wire with 2X4.0sqmm +1X2.5 sq. mm FR PVC insulated copper conductor single core make : Polycab, finolax, gloster,KEI, Havells |
| 31 | Wiring for circuit / submain wiring along with earth wire with 2X6.0 sq mm +1X4.0sq. mm FR PVC insulated copper conductor single core make : Polycab, finolax, gloster,KEI, Havells |
| 32 | Cutting chases for concealed conduit wiring etc and making good cutting not exe 10cm girth. |
| 33 | Supply, fixing and commissioning of Powder coated 16 SWG MS Box size 15”x18”x18”, Three phases four wires CT Operated Digital energy meter make- HPL/Secure/trinity/L&T/Schneider, Digital energy meter must display Voltage, Current, Power factor, KW, KVA and necessary parameters on selection, 200/5 ratio CTs three number arrangement of fixing of C.T. in nearby main switch with fixing arrangement including cable entry box at main switch & wiring of C.T. in flexible conduit pipe with lugging, |
| 34 | S&F Earth continuity conductor fixed to wll on batten or recess or chases or buried in ground or any other indicated sitution for loop earthing etc. as required 4.0sq mm galvanised iron strip. |
| 35 | PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sq. mm 3 & 1/2 core make : Polycab, finolax, gloster,KEI, Havells. |
| 36 | Fixing only PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sq. mm 3 & 1/2 core. |