| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 3 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)includingattachedpilasters,columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Centring and shuttering including strutting, propping etc. and removal of form work for : Retainingwalls, returnwalls,walls (anythickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 7 | Providing and fixingup to floor five levelprecast cement concrete hollow block,including hoisting and setting in position with cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering complete. 1:1.5:3 (1Cement: 1.5 coarsesand (zone-Ill)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) . |
| 8 | Makingplinthprotection 50mmthickofcementconcrete 1:3:6 (1cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 9 | Providing cement concrete surface drain including earthwork excavation 10 cm thick base concrete and 15 cm thick side wall with 1:3:6 ( 1 cement : 3 Coarse sand: 6 graded stone aggregate of 40 mm nominal size) cement concrete finished with 1:4 (1 cement : 4 sand) a floating coat of neat cement inside the drain and its top and exposed surface including earthwork in excavation and disposed of surplus earth etc. 15 cm x 15 cm. Suface drain. |
| 10 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : 1:2:4 (1cement : 2 coarse sand(zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 11 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Shelf for store room |
| 13 | Centring and shuttering including strutting, propping etc. and removal of form for : Foundations,footings,basesof columns,etc.formass concrete. |
| 14 | Centring and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ) |
| 15 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts. Main building col. |
| 17 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars. |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Category-II (A) |
| 19 | Providing and fixing panelled or panelled and glazed shutters for doors, windows andclerestory windows, fixing withbutt hinges of required size withnecessary screws,excludingpanellingwhichwillbepaid forseparately,allcompleteasperdirectionofEngineer-in-charge.(Note: Butt hinges and necessary screws shall be paid separately). Second class teak wood. |
| 20 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 21 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378). 250 x 16 mm |
| 22 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378). 150 x 10 mm |
| 23 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378). 125 mm |
| 24 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. G.I.Pipes: Timber Godown Racks( 40 & 32 mm dia pipes). |
| 25 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. G.I Pipes |
| 26 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. |
| 27 | Providing and fixing on wall face unplasticisedRigidPVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 28 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. Bend87.5°. 110 mm bend. |
| 29 | Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Roofing sheet |
| 30 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm). |
| 31 | 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand). |
| 32 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm. |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 34 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking withpushandpull operationcomplete,including thecost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover. |
| 35 | Removing wood work in frames of door window, weather boards , Truss, Purlings , Roofing Sheet etc.and up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 36 | Providingand fixinginsulatingboardceiling of approvedquality with necessary nails etc. complete (frame work to be paid separately) : white face insulating board. 12 mm thick. For eaves board. |
| 37 | Providing & installation and testing of electrical fittings completely i.e Ceiling fans, Tube Lights, MCBs ,Isolator, sockets, Switches, Gang Box, including wiring ,etc.. Wherever necessary at the time of work execution as per direction of Engineer-in-charge.- |