| 1 | Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. |
| 3 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 4 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead : For thickness of tiles 25mm to 40mm. |
| 5 | P&F 1st quality Heavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc. in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS:15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grouting the joints with white cement and matching pigment etc. complete. Size 600mm × 600mm |
| 6 | Providing Solid PVC false Ceiling consisting of 600mm×600mm, 5mm (±0.25) thick Plain embossed PVC sheet of Density 600 Kg/Cbm Manufactured by an ISO-9001-2015 certified Company, used as panel insert in a frame work made using powder coated aluminum T-section of sizes 1\"×1\" (25×25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2\"×2\" (600×600mm). The aluminum framework is supported from the ceiling with the help of \"J\" hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level etc. The aluminum frame work is supported on side wall with the use of aluminum L-section of size 1\"×1\" (25×25mm) angles etc. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing |
| 7 | Providing and Fixing of wall paneling on grid made out of PVC profile section of size 21×17mm with a wall thickness of 1.5mm ±0.2mm, fixed on the existing wall with wood screw of size 50mm×8mm with rowel plug at a spacing of 900mm center. uPVC profile section of size 150mm×10mm with a wall thickness of 1.0mm ±0.2mm to be fixed on the grid by self tapping screw of size 19mm×6mm. Necessary cutouts for electrical connection to be provided at required places. The edge and periphery, finally to be covered by extruded PVC beading section of size 28mm×12mm with a wall thickness of 1.0mm ±0.2mm complete as per manufacture’s specification and direction of Engineer-in-charge. |
| 8 | P&L integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations. (a) Applying & grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS:2645 over the RCC slab including cleaning the surface before treatment. (b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cement mortar 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS:2645 over 20 mm thick layer of cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 to required slope & treating similarly the adjoining walls upto |
| 9 | 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300×300mm square (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 10 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 11 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) complete. Up to 1500 Cm2 Tiles |
| 12 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work. Full Edge moulding |
| 13 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead : of area 3 square meter and below. |
| 14 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish : 12mm thick |
| 15 | Colour washing of all shades to give an even shade including all scaffolding : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing ). |
| 16 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. New Plastered Surface (three or more coats) |
| 17 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. Old Plastered Surface (two or more coats) |
| 18 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding : Two or more coats on new work including preparation of base with primer, putty, lippy etc complete in all respect. |
| 19 | Old work (One or more coats) |
| 20 | Providing and Fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron \"Y\" shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer-in-Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra) |
| 21 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 22 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete: |
| 23 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 24 | P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. |
| 25 | P&F aluminum work for doors, windows, ventilators & partition with extruded built up standard tubular / appropriate Z sections & other sections of approved make conforming to IS:733 & IS:1285, fixed with rawl plugs & screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gap at junctions, at top, bottom & sides with required PVC/neoprene felt etc. Aluminium section shall be smooth, rust free, straight, mitered & jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling, C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc., all complete as per architectural drawings & the directions of Engineer-in-charge. (Glazing & paneling to be paid for separately). For fixed portion Polyester Powder coating aluminum (minimum thickness of powder coating 50 micron) |
| 26 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyester Powder coating aluminum (minimum thickness of powder coating 50 micron) |
| 27 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin, of approved brand and manufacture in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. |
| 28 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 5.0 mm thickness (weight not less than 13.50 kg/sqm) |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 8 mm thickness |
| 30 | Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge |
| 31 | Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 32 | Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250×40×3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Nigeria teak wood Grade-I. |
| 33 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure \"A\" : 35 mm thick Commercial Veneer both side |
| 34 | Extra for providing other type of fittings as mention in annexure-A (as approved by EI) : Stainless steel fittings |
| 35 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 36 | Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) |
| 37 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 38 | M-10 grade Nominal Mix 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 39 | Providing & Fixing BWR ISI marked 19 mm board of approved make for making wardrobe / shelves and other furniture with fevicol & nails complete as per approved by engineer-in-charge. |
| 40 | Providing & Fixing drawer handle of approved make for drawers with screws complete as per approved by engineer in charge. 100mm long |
| 41 | 150mm long |
| 42 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge. 0.8mm thick mica |
| 43 | Providing and Fixing Almirah lock (50 to 70 mm size) of approved make without pair of handles for door with necessary screws etc. complete as per direction of Engineer-in-charge. |
| 44 | Providing & Fixing Aluminium composite panel of indo bond/euro/flexi bond of equivalent made 3mm that with 0.5mm thick skin & PVDF coated of approved shads for toilet door in double layer in Aluminium frame complete in all respect as per sample made 3mm that with 0.5mm thick skin & PVDF coated of approved shads for toilet door in double layer in Aluminium frame complete in all respect as per sample approved by Engineer-in-charges. |
| 45 | Providing gola 75×75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 46 | Providing and Fixing Horizontal blinds/Venation blind shall be cold rolled formed U shape 23mm high × 25 mm wide with flanged edges. It shall be made of heavy gaze 0.56 mm galvanized steel, Slates shall be made of virgin Al. alloy (having 3.5–4.5% of Mg. Content of width 25mm the slat shall have dust guard paint coating, the chord lock shall be of thick tomized steel and shall be securely attach in the head rail. It shall provide locking arrangement of the cord. Tilt rod shall be made of galvanized steel it shall have a D shaped with an average cross section with diameter of 6mm to achieve minimum torsional deflection. |
| 47 | Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. |
| 48 | Supplying and Fixing fixed wire gauge of 14 mesh × 24 gauge to the metal frame of rolled section by metal beading 20×3mm with suitable screw at not exceeding 150mm distance. |
| 49 | P&F PVC Storage Tank ISI Marked (IS:12701) indicating the BIS license No.), of approved make with cover, 25 mm dia 1M long G.I. over-flow pipe & 25cm long washout pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity. |
| 50 | 2000 litres capacity. |
| 51 | Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed : All kinds of soil |
| 52 | Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: All kinds of soil Pipes cables, etc. exceeding 80mm dia but not exceeding 300mm dia. |
| 53 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 54 | Providing & Fixing of ward robe shutters made out of 19mm thick BWP block board ISI of superior quality make with following details : Front side finishing with 1mm thick superior quality mica approved make and 0.8mm thick approved shade mica in the inner side. Covering with teak wood beading 25×12mm all the sides of shutter & 35×12mm on outer frame for making good the wall joint including heavy brass S.S. fittings (Handle 200mm 2 Nos., Tower Bolt 150mm 2 Nos., Brass Lock 1 Nos., Magnetic Catcher 2 Nos., Brass Hinges 75×40×2.5 mm 6 Nos., SS Hanger Rod 20mm dia) complete as per drawing and design approved by Engineer in Charge. |
| 55 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. |
| 56 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) For area of each slab from 901 to 2000 Sq.Cm : |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 20mm nominal size |
| 58 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 59 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Coupler (socket) 110mm dia |
| 60 | Plain Tee 110mm dia |
| 61 | Bend 87 .5 110mm dia |
| 62 | Vent Cowel 110mm dia |
| 63 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 580 mm × 450 mm |
| 64 | 460 dia for counter top |
| 65 | Add extra for using 25mm GI waste pipe instead of PVC waste pipe |
| 66 | P & F 1st quality WVC pedestal for wash basin. |
| 67 | Labour charges for removing W.C. pan (any type) of all sizes with care including all necessary fittings P or S trap. |
| 68 | Labour charges for removing and re-fixing of urinals (all type & sizes) including all per & sizes) including all necessary fittings. |
| 69 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (large) or half stall size 610×400×80mm. |
| 70 | P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make. For 2 Urinals |
| 71 | Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor. Double Syphonic European W.C. with mounted W.V.C. flushing cistern of 10 litre capacity complete with all necessary internal fittings with Hydraulic seat cover. |
| 72 | P & F Liquid Soap Container with brackets complete of approved make: C.P. brass |
| 73 | P & F Soap Dish or Tray of approved quality/make C.P. brass heavy and superior quality. |
| 74 | P & F Twin- peg of approved quality / make C.P. brass (heavy)Superior quality |
| 75 | P&F Looking Mirror 5mm thick of approved make with ornamental frame size 50×12 with 6mm Ply Board on Back Side Complete as per approved sample |
| 76 | P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Engineer-in-Charge |
| 77 | Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge Swan neck pillar cock 15 mm nominal size |
| 78 | Bib Cock with long thread 15 mm nominal size |
| 79 | Stop cock long thread |
| 80 | P & F Toilet Shelf of approved quality/make: W.V.C. (I.S.: 2556 Mark) Size 550 mm |
| 81 | P & F Towel Rail or Ring of approved quality/make: C.P. brass Towel Rail elbow type with concealed screws size 600 mm (Heavy duty). |
| 82 | C.P. Brass Towel Ring revolving type |
| 83 | P & F Toilet Paper Holder with rod of approved quality/make: C.P. brass heavy & Superior quality. |
| 84 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : Mosaic fine polished kitchen sink size 600×450×200mm. |
| 85 | P & F Gun-metal Non-return Valve or Check Valve (IS : 778 Make) of approved make, superior quality: 25mm nominal bore. Horizontal |
| 86 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS (IS:9537 P-III) virgin material PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder / 3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E-04, E-05 & E-07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Short point (up to 3 mtr.) |
| 87 | Medium point (up to 6 mtr.) |
| 88 | Long point (up to 10 mtr.) |
| 89 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS (IS:9537 P-III) PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E-04, E-05 & E-07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR On board |
| 90 | Short point (up to 3 mtr.) |
| 91 | Medium point (up to 6 mtr.) |
| 92 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, minimum width of switch toggle (PUSH PART) should not less then 20mm, including all as per pre approved by Engineer in charge, making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 10A one way switch |
| 93 | 16 A one way switch With Led Indicator |
| 94 | 6/16 A shuttered socket |
| 95 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. ½ Module |
| 96 | 4 Module |
| 97 | 8 Module |
| 98 | 12 Module |
| 99 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable (steel rope), cotter pin with 3×1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. 1400 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5) |
| 100 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5) |
| 101 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including all as per pre approved by Engineer in charge, making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 5 step fan regulator 2 Module 360 degree rotating |
| 102 | P&F 1.2mm thick G. I. / M.S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 1.2 mm thick M.S. Sheet boxes 300mm×375mm× 75mm |
| 103 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including all as per pre approved by Engineer incharge, making connections, testing etc. as required. For additional technical parameters of product /work refer Annexure \"A\" attached with this BSR RJ-11 telephone jack Double line |
| 104 | USB Charger 1 A - 1 M with BIS mark |
| 105 | RJ-45, Cat 6 computer jack with shutter |
| 106 | T.V. coaxial socket |
| 107 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 108 | Modular MCB 6 A to 32 A SP |
| 109 | Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable with 0.5mm thick Solid Annealedre Copper Conduct or as per IS:8130 / 84 telephone cable confirming to TEC specifications GR/WIR 06/03, March-2002 in existing pipe/open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 5 pair |
| 110 | SITC of Pressure boosting pump with 24Ltr. MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON/OFF system, 2900RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect. Appropriate type test certificate / OEM shall have submit NABL/CPRI/ERDA accrediated lab type test certificate be for execution. All as per pre approved by Engineer in charge. For additional technical parameters of products / work, refer Annexure \"A\" attached with this BSR. 1.5 HP (37 - 20) Mtr., (24 - 48) LPM |
| 111 | S&F following sizes (dia.) of ISI marked virgin material MMS (IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 25 mm |
| 112 | 40 mm |
| 113 | P&F of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load & site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, min. phase termination capacity of 35sqmm, conductor line load reversibility, IP-20 contact protection & fitted in existing distribution board/sheets, min. electrical operation 20000 upto 20A rating & 10000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre |
| 114 | approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating |
| 115 | 125 A rating |
| 116 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type TPN phase selector Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439 - 1&3 powder painted with reversible door (for double door DB only ) complete with 100 amp. insulated copper bus bar/ shorting link , neutral link, earth link, color coded interconnecting wire set of suitable rating and din bar, masking sheet provided with 3 nos. 63 Amp rotary switches, 3 nos. rocker switches for phase identifications etc. making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall |
| 117 | have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Double door. IK-09 and IP-43 with Metal end box 4Way (Incomer 8, Outgoing 4+4+4) |
| 118 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a), (b), (c), (d), (e), (f), (g), (h) as below: |
| 119 | (a) Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness, required hardware, concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 120 | (c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp) and by solid bus bar (>63 amp) control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned. Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra) |
| 121 | (d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. |
| 122 | (e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100×50×5 mm (to be paid Extra) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. |
| 123 | (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. |
| 124 | P&F of BIS approved Current Transformer as per PWD specification for electrical Works, ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection, with all necessary support in existing panel including connection etc. as required CT Ring Type Tape Wound/ Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (min.), including all necessary support in existing panel including connection etc. as required. All as per pre approved by Engineer in charge. All as per pre approved by Engg.-in-charge. For additional technical parameters of products/ work, refer Ann-A attached with this BSR. Ring type tape wound CT C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA |
| 125 | Supplying and Fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. Electrolytic grade Aluminium bus bar 6010 grade |
| 126 | Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct-Ammeter / CT operated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. Three phase Ammeter with Inbuilt Selector Switch |
| 127 | Three phase Voltmeter with Inbuilt Selector Switch |
| 128 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. Red/yellow/Green colour |
| 129 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings, conforming to IS/IEC 60947 P-2:2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55º and without derating upto 40º, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking |
| 130 | capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55º and without derating upto 40º, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp=8 KV, rated insulation voltage 690 V. provision for UVR, shunt trip, earth fault trip, door interlock, pad lock & rotary handle, including making connections etc. as required. |
| 131 | OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 4 pole MCCB with Thermal Magnetic release 125 Amp, 25 kA, adjustable O/L & adjustable S/C setting, |
| 132 | 250 Amp, 35 kA, adjustable O/L & adjustable S/C setting, |
| 133 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 70.0 Sqmm 3.5 core |
| 134 | 10.0 Sq. mm 2 core |
| 135 | Supplying and drawing FRPV Cinsulated & unsheathed flexible copper conductor as per PWD specification for Electrical Works with ISI marked (IS:694) and as per IS8130:2013 of 1.1kV grade. Wire should be made from 99.90% purity copper, class 5 str and ing in acc. to IS:8130 / IEC60228 for lower watt loss, oxygen free for less chances of oxidization, insulation PVC type A/C/D, flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part5, inexisting surface or recessed PVC/MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 1×1.5 sq.mm |
| 136 | 1×2.5 sq.mm |
| 137 | 1×4.0 sq.mm |
| 138 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm×600mm×3.0mm by embodying 3 mtr. below the ground level with 20 mm dia G.I. \"B\" class watering Pipe, including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, & Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top dia 225 to 260 mm, Bottom dia 300 to 350 mm & Height 250 to 300 mm & embodying the pipe complete with alternate layers salt & coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurement book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. |
| 139 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. 300 mm sweep (900/1400 RPM) |
| 140 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10%, P.F.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report |
| 141 | from OEM shall be submitted. All as per pre approved by Engineer-in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. 1170mm (±10%) LED batten with min. lumen output 2200 lm |
| 142 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Square SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency >85%. System Lumen efficacy of ≥ 110lm / watt, THD < 10%, Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintained till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on |
| 143 | on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. Surface Mounting (with extruded alumn. Housing) Minimum lumen output 1950 lm |
| 144 | Providing & Fixing of IP20, 2\"x2\" LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non-yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt, THD <10%, p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). |
| 145 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .Surface Mounting Minimum lumen output 3600 lm |
| 146 | Supply & erection of Galvanized Iron pole with galvanizing done in singled lipping (Average coating thickness Min. 65 Microns) Swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate, The pole shall be made from steel tube & Pipe (IS:1141, Fe410) including excavation of the pit & filling the same with CC of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40cm dia upto 114.3 mm outer dia & 50cm beyond 114.3 mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry with 32mm dia \"B\" class GI cables leaves complete as required of following ht. & designation. (See Table P-02 for specs) All as per pre approved by Engg.-in-charge for add. tech. parameters of products / work, refer Annexure \"A\" attached with this BSR 7.5 Mtr. (410 SP-5) |
| 147 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I/ IS:7098 P-I of 1.1KV with electrolytic grade Copper made of copper rods confirming to IS613-1964, of purity>99.7%, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe / open duct / cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product/ work refer Annexure \"A\" attached with this BSR 1.5 Sq. mm 2 core |
| 148 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stabilization report submitted for UV cover) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each. The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety, Power Factor >0.95 driver Efficiency >85%, THD(I) <10% Humidity 10% to 90% RH Working Temp -5ºC to 45ºC driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with |
| 149 | minimum 70% lumen maintained, CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark / Name Engraved / Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. LED Street Light fixture with Minimum lumen output 7500 lm |
| 150 | Supply, Installation, & Testing of 19\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Single mode glass Fiber Optic Cable Patch panel/LIU loaded with flangless / screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wall mount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. 24 Ports |
| 151 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection, testing, etc. as required. For specification of Wiring accessories refer Chapter E-07 related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 152 | Supply, Installation, Testing & Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit (IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr. (IDU to ODU), copper power cable upto 3.5 Mtr. (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V ±10% with low & high voltage cutoff & 50 hz, single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engg-in-charge. For add. tech. parameters of products/ work, refer Ann.\"A\" attached with this BSR. 1.5 TR ISEER not less then 4.6 |
| 153 | Supply, installation, testing & commissioning of interconnecting copper refrigerant piping of DHE Grade C12200-ASTM B68, B75, chemical composition of copper % -99.0 Min & Phosphorus % -0.015 to 0.040. For Annealed copper tube - Tensile strength = 210 Mpa with elongation %=40 Min. Ink Mark Brand Printing on Hard Tubes should be present duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified \"Class O\" in Fire Propagation as per BS 476 Part 6 including chase cutting and filling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered |
| 154 | with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. 38 mm O.D., wall thickness ≥ 1.4mm (insulation – 19 mm thick) |
| 155 | Providing & Fixing of IS : 4985- 2000 Class-4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. 20 mm |
| 156 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 50 mm dia per running inch length |
| 157 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 158 | SITC of 55\"\" 4k Resolution or Better LED TV with remote control and wall mount unit / floor stand complete with making connections etc. as required. |
| 159 | Labour charges for dismantling of surface/ recessed switch board of any size and depositing the same with listing of material in store. |
| 160 | Labour charges for dismantling of switch accessories like switch, socket, ceiling rose, holder and depositing the same with listing of material in store. |
| 161 | Labour charges for dismantling of wiring in existing conduit of following size and depositing the same with listing of material in store.up to 2.5 sq. mm. wire |
| 162 | 4/6 sq. mm. wire |
| 163 | 10 sq. mm. wire Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |