| 1 | SH: Construction of 2(two) Residential Staff Quarters |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m |
| 3 | a) Loose/Soft soil. |
| 4 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 5 | Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level |
| 7 | a) 1 : 5: 10( 1 cement : 5 c/sand : 10 graded stone aggregate. 40mm. nominal size). |
| 8 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 ( 1 cem : 2 c/and : 4 gr st aggrt 20 mm n/size) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 10 | a) Foundation footings, bases of columns etc. and mass concrete. |
| 11 | b) Columns, pillars, posts and struts (square rectangular or polygon in plan). |
| 12 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Providing and laying in position of specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: |
| 14 | a) 1:1.5:3 ( 1 cement : 1.5 c/sand : 3 graded stone aggregate 20mm. Nominal size). |
| 15 | R.C.C. work in beams suspended floors, roofs, having slope up to 15 landing, balconies, shelves, chajjas, lintels bands, plain windows sills, staircases and spiral staircases and spiral staircases up to floor five level excluding the cost of centerring, shutering, finishing and reinforcement with |
| 16 | a) 1:1.5:3 ( 1 cement : 1.5 c/sand : 3 graded stone aggregate 20mm. Nominal size). |
| 17 | R.C.C. work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, Pillars piers, abbutment, posts and struts etc. upto floor five level excluding cost of centering, shuttering, finishingand reinforcement : |
| 18 | a) 1:1.5:3 ( 1 cement : 1.5 c/sand : 3 graded stone aggregate 20mm. Nominal size). |
| 19 | Steel Reinforcement for R.C.C. work i/c straightening, cutting,bending, binding all complete. nd placing in position complete . |
| 20 | a) Thermo mechanically treated bars |
| 21 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in:cement mortar 1:4 (1 cement :4 coarse sand |
| 22 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in cement mortar 1:4 (1 cement :4 coarse sand |
| 23 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.Hot finished welded type tube |
| 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 25 | a) First class Uningthou wood |
| 26 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 27 | Providing wood work in frame of false ceiling partition etcsawn & put in position |
| 28 | a) Tolhao wood |
| 29 | Providing and fixing ISI marked oxidised MS sliding door dolts with screws etc. completed |
| 30 | a) 250 x 16 mm |
| 31 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 32 | a) 200 X 10mm. |
| 33 | b) 150 x 10mm |
| 34 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : |
| 35 | a) 100mm |
| 36 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 38 | a) Fixed to openings /wooden frames with rawl plugs screws etc. |
| 39 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20mm nominal size stone aggregate |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer),with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (lcement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 41 | a) Size of Tile 500x500 mm |
| 42 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (1 cement : 3coarse sand) finished with a floating coat of neat cement.(18mm thick) |
| 44 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : |
| 45 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : |
| 46 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately): i) White face insulating board (12mm thick) |
| 47 | Providing and fixing 20 mm plank as eave board with |
| 48 | a) Tolhao/ uchane |
| 49 | 12mm Cement Plaster 1 :4 ( 1 Cem : 4fine sand) |
| 50 | 15 mm cement plaster on rough side of single or half brick wall of mix :1:4(1 cement: 4 coarse sand) |
| 51 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 52 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 53 | a) Water thinnable cement primer |
| 54 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. |
| 55 | a) Two or more coats on new work- |
| 56 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 57 | 20 mm thick plank walling ( tolhao local best quality) and tolhaw wood beading 62mm x12mm i/c fitting and fixing with necessary screw and nails complete( frame work to be paid seprarately) |
| 58 | SH: Construction of 2(two)Septic Tank & Soak Pit |
| 59 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 60 | a) All Kinds of soil |
| 61 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 62 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 63 | a) 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 64 | b) 1:2:4( 1 cement : 1 coarse sand : 2 stone agtt 20 mm nominal size |
| 65 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in:cement mortar 1:4 (1 cement :4 coarse sand |
| 66 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in cement mortar 1:4 (1 cement :4 coarse sand |
| 67 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 68 | a) Suspended floors, roofs, landings, balconies and access platform. |
| 69 | Steel Reinforcement for R.C.C. work including straightening , cutting,bending and placing in position and binding all complete. |
| 70 | a) Thermo-mechanically treated bar. |
| 71 | R.C.C. work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, Pillars piers, abbutment, posts and struts etc. upto floor five level excluding cost of centering, shuttering, finishingand reinforcement : |
| 72 | a) 1:1.5:3 ( 1 cement : 1 .5c/sand : 3 graded stone aggregate 20mm. Nominal size). |
| 73 | 15 mm cement plaster on rough side of single or half brick wall of mix :1:4(1 cement: 4 coarse sand) |
| 74 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. i) Semi rigid pipe |
| 75 | a) 32mm dia |
| 76 | b) 40mm dia |
| 77 | SH: Installation of 2(two) WS & SI |
| 78 | Providingand fixing water closet squatting pan (Indian type W.C. pan ) with 100 mmsand cast Iron P or S trap, 10 litre low levelwhiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 79 | a) White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests |
| 80 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 81 | a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 82 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 83 | Kitchen sink with drain board |
| 84 | a) 510x1040 mm bowl depth 225 mm |
| 85 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 86 | a) 100 mm diameter |
| 87 | Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms |
| 88 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 89 | Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete |
| 90 | a) 10 litre (full flush) capacity-white |
| 91 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 92 | Flexible pipe |
| 93 | a) 40 mm dia |
| 94 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 95 | Providing and fixing toilet paper holder: |
| 96 | a) C.P. brass |
| 97 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 98 | a) Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 99 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 100 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 101 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 102 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 104 | Concealed work, including cutting chases and making good the wall etc. |
| 105 | a) 15 mm nominal outer dia Pipes |
| 106 | b) 25 mm nominal outer dia Pipes |
| 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 108 | External work |
| 109 | a) 50 mm nominal outer dia Pipes |
| 110 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 111 | a) 15 mm nominal bore |
| 112 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 113 | a) 15 mm nominal bore |
| 114 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 115 | 15 mm nominal bore, 98 mm long, weighing not less than 75 gms |
| 116 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 117 | Providing and fixing PTMT extensionnipple for water tank pipe,fittings of approved quality and colour |
| 118 | a) 25mm nominal bore, weighing not less than 62 gms |
| 119 | Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. |
| 120 | Slip Coupling/ Socket |
| 121 | a) For 22.22 mm outer dia pipe |
| 122 | Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. |
| 123 | Male Thread Tee |
| 124 | a) For 15.88 mm outer dia x 15 mm nominal dia threaded |
| 125 | b) For 22.22 mm outer dia x 15 mm nominal dia threaded |
| 126 | Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. |
| 127 | Female Thread Tee |
| 128 | a) For 15.88 mm outer dia x15 mm nominal dia threaded |
| 129 | b) For 22.22 mm outer dia x 15 mm nominal dia threaded |
| 130 | Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. |
| 131 | Female Thread Connector/ Adapter |
| 132 | a) For 15.88 mm outer dia x 15 mm nominal dia threaded |
| 133 | b) For 22.22 mm outer dia x 15 mm nominal dia threaded |
| 134 | Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge |
| 135 | Male Thread Connector/ Adapter |
| 136 | a) For 15.88 mm outer dia x 15 mm nominal dia threaded |
| 137 | b) For 22.22 mm outer dia x 20 mm nominal dia threaded |
| 138 | Providing and Placing Fire Extinguisher 4kg ABC type |
| 139 | SH: Providing IEI for 2(two) Quarters |
| 140 | Wiring for light point/Fan point/Exhaust Fan point/Call bell point with 1.5 mm 2 PVC insulated copper conductor single core cable in PVCinsulated casing copper with modular plate size,G.I box and earthing the point with 1.5 mm2 PVC insulated copper conductor single copper conductor single core cable etc. as reqd |
| 141 | a) Group - A |
| 142 | b) Group - C |
| 143 | Wiring for light point/power plug with 2 x 4 mm2 PVC insulated copper conductor single core cable in PVC casing and capping along with 1 no. 4 mm2 PVC insulated copper conductor single core cable for loop earthing etc. as reqd. |
| 144 | Wiring for circuit/sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable in PVC casing and capping etc. as reqd. |
| 145 | a) 2 x 1.5 mm2 + 1 x 1.5 mm2 earth wire |
| 146 | b) 2 x 2.5 mm2 + 1 x 2.5 mm2 earth wire |
| 147 | c) 2 x 4 mm2 + 1 x 4 mm2 earth wire |
| 148 | S/F 3 pin 5 amp ceiling rose on the existing juinction box/wooden block i/c connection etc. as reqd |
| 149 | S/F brass batten/angle holder i/c connection etc. as reqd. |
| 150 | S/F 48” sweep (1200 mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regular etc as reqd. (Make Bajaj / Usha or similar) |
| 151 | Supplying & Fixing stepped type electronic fan regulator on the existing modular plate switch box l/c connection but excluding modular plate etc. as reqd. |
| 152 | S/F 20 W LED tube ultra Havells |
| 153 | S/F 15 W Classy LED Bulb Havells |
| 154 | S/F (following way,) single/double pole and neutral, sheet stell MCCB distribution board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, detachable gland plate, interconnection,phosphatized and powder painted including earthing etc as reqd.(but without MCB/RCCB/Isolator). |
| 155 | a) 2 way single door |
| 156 | Supplying and fixing 5 amp to 32 amp rating 230 V B series MCB for lighting and other load for (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd. |
| 157 | b) Single pole and neutral |
| 158 | 10 sq.mm ISI marked, FR PVC insulated, single core copper conductor cable |
| 159 | S/F Maru Deluxe USS combine |
| 160 | S/F of modular switch box with cover complete |
| 161 | a) 8 modules |
| 162 | b) 4 modules |
| 163 | Supply and fixing (following modular type switch / socket) on the existing modular switch box/ connection but excluding modular plate etc as reqd |
| 164 | a) 3 pin 5/6 amps socket outlet |
| 165 | b) 5/6 amps switch |
| 166 | S/F 60 amp/63 amp 500V porcelain fuse unit (Kit-Kat) |