| Sl. No. | Item Description |
| 1 | Attending sewage line/ manholes blockages complaints by cleaning of sewage line/ manholes blockages (including WC, Urinal, Kitchen and bathrooms) systematically using necessary tools mechanical pump and/ or manually such as by rodding, passing rope knots, bamboo fanti and disc of required size (with safety measure for gas etc) flushing with water the pipe until water clear the flow of sewage from both side between two adjacent manhole/ gully traps or WC/ NT of any size or depth, taking out sludge in semi liquid stage/ roots of tree etc including all water effluences etc and removing all materials from the site of work to outside MD land in closed vehicle and depositing in earth pit of suitable size including supply of sprinkling bleaching powder and covering sludge with earth after removal of blockage etc complete all as specified and as directed.Notes : (i) These complaints shall be attended on day to day basis with sufficient manpower and tools. (ii) Quoted rate shall deemed to be inclusive of earthwork & excavation, sprinkling sufficient bleaching powder including transporting the sludge & other materials in closed vehicle. |
| 2 | Taking out (desilting) silt, bricks bats, debris, liquid waste, sludge in solid/ semi solid state fromthe manholes of depth not exceeding 1.0 m, including pumping out sludge wherever necessary, sludging, diverting the flow in the drain, if necessary and staking the removed silt/ sludge & deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting inside the manholeand taking similar safety measures and removing the sludge to outside MD land in closed vehicle and cleaning the manholes with clean water etc complete all as directed. |
| 3 | All as per item No. 2 here-in-above but for manholes /grease/ gully traps of depth exceeding 1.00 m but not exceeding 2.00 m. |
| 4 | All as per item No. 2 here-in-above but for manholes of depth exceeding 2.00 m but not exceeding 4.50 m. |
| 5 | Cleaning of 100 mm bore blocked Sewage lines in any depth by pressure Jet by using mechanical/ hydraulic pressure using Vehicle type hydraulic methods or modern methods and/ or manually such as by rodding, passing rope knots, bamboo fanti and disc of required size (with safety measure for gas etc) from manholes to manholes or manholes to cleaning eye or cleaning eye to clean eye until the smooth flow of sewage line is restored including taking out sludge in semi liquid stage including all water effluences etc re-fixing manhole cover and removing all materials from the site of work to outside MD land in closed vehicle and depositing in excavated earth pit of suitable size including supply and sprinkling bleaching powder and covering sludge with earth after removal of blockage etc complete all as directed.Note : Quoted rate shall deemed to be inclusive of earthwork & excavation, sprinkling sufficient bleaching powder including transporting the sludge & other materials in closed vehicle. |
| 6 | All as per item No. 5 here-in-above but 150 mm bore sewage line. |
| 7 | All as per item No. 5 here-in-above but 200 mm bore sewage line. |
| 8 | Taking down cement plaster of any description on PCC/stone surface/brick surfaces including raking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 9 | Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 10 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MoD land complete all as directed. |
| 11 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as directed. |
| 12 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 13 | Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed. |
| 14 | Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets complete all as specified and as directed. |
| 15 | Demolition and breaking up drain pipes (Salt glazed stone ware, AC or Reinforced concrete) of 150 mm internal dia set in cement mortar including bedding and haunching complete all as specified and as directed |
| 16 | All same as per serial item No. 15 here-in-above, but 200 mm bore. |
| 17 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stackingserviceable tiles at site andremoval of entire debris as ordered outside MoD land complete all as specified and as directed. |
| 18 | Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed. |
| 19 | Taking down chowkat or frame with shutters (including grills, fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed. |
| 20 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed. |
| 21 | All as per item No. 20 here-in-above but exc 1.5 m and not exc 3.0 m in depth -do- |
| 22 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed. |
| 23 | Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed. |
| 24 | M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface. |
| 25 | M&L for preparing surface and filling Moorum / red bajri in road side berms or paving and similar works, laid in thickness not exc 15 cm, spread, levelled and rammed to required gradient and camber including watering complete all as specified and as directed. Note : Measurement shall be taken after compaction. |
| 26 | M&L for providing and injecting chemical emulsion for post construction Anti Termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling holes 12mm dia upto 300mm deep and 300mm centre to centre and plugging holes in CM 1:2 complete all as specified and as directed. |
| 27 | M&L for post construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litres per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same to match with the existing finish complete all as specified and as directed. |
| 28 | M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 29 | M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets and the like including weathering, slightly rounded, chamfered angle and throating as directed including useand waste of form work (straightor curved) all exposed surface of concrete finished fair complete all as specified & as directed. |
| 30 | M&L for cement concrete 1:2:4 type B0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets and the like including weathering, slightly rounded, chamfered angle and throating as directed including useand waste of form work (straightor curved) all exposed surface of concrete finished fair complete all as specified & as directed. |
| 31 | M&L for factory madepre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed. |
| 32 | M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:4) complete all as specified & as directed.Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule. |
| 33 | M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinthbeams, base of columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified & as directed.Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 34 | M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) in columns, pillars, piers, posts, struts and the like complete all as specified & as directed.Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 35 | Supply only Integral Water Proofing Compound (ISI Marked). |
| 36 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified & as directed. |
| 37 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified & as directed. |
| 38 | S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows, ventilators & partitions, with one or more rebates including joining cleat for fixing, etc. complete all as specified and as directed. |
| 39 | S&F aluminium powder coated (minimum thickness of powder coating 50 micron) doors shutter, aluminium section weighing 0.55 Kg/m (minimum)including necessary joining cleats, glazing clips, ruber neoprene packing, powder coated handles 2 Nos in each door, hinges, powder coated aluminum snap beading screws etc. complete all as specified and as directed.Note: Glass shall be measured and paid for seperately. |
| 40 | S&F aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/m (minimum) including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed.Note: Glass shall be measured and paid for seperately. |
| 41 | M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed. |
| 42 | All as per serial item No. 41 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders. |
| 43 | S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed. |
| 44 | S&F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete conforming to Fe 290 (Gde E-165) complete all as specified and as directed. |
| 45 | S&F 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including MS powder coated (white) snap Grid of size 605x605 mm frame work using 24mm x 32mm x 0.7mm main ‘Tee’ runner to be interlocked, 24mm x 32mm x 0.70mm cross ‘Tee’ and 24mm x 32mm x 0.70mm angles fixed to wall for ceiling including necessary supporting hanger with 2 to 3 mm dia GI wire (upto 3.5m long adjustable) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 24x7mm size 60mm long for securing frame work to ceiling suspended @ 1200mm centre to centre both way with PVC rawl plug with & including 6mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer’s instructions, with & including painting the ceiling board with two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer on ceiling with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of false ceiling work including testing on completion as ordered complete all as specified & as directed. |
| 46 | S&F 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board of minimum size 605 x 605mm fixed to existing frame work with screws as in false ceiling fixed as per manufacturer’s instructions, with & including painting the ceiling board with two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer on ceiling complete all as specified & as directed. |
| 47 | Material and labour for complete removal of existing water proofing treatment of any description or any other type of treatment over roof slab, parapets, chimney stacks, etc including cement plaster over RCC roof and cleaning the surface with wire brushes and washing with water, removing of insolvent materials and removing & depositing the debris, rubbish, etc outside MoD land, brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer\"s instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is cured with water for 7 days & completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 160 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed.Notes: (i) WPC shall be measured & paid for separately as ‘Supply only’. (ii)The work shall be carried out only through manufacturer or their authorised applicator and contractor shall submit a written guarantee of the manufacturer/authorised applicator for the effectiveness of WPT for 10 years from the date of completion of contract. (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps. |
| 48 | M&L for 18 to 20mm thick machine cut mirror polished Kota stone slab of minimum size 550 x 550mm, laid in floors over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.Note : Quoted rate shall deemed to be inclusive of cement screed bed/bedding layer. |
| 49 | M&L for machine cut mirror polished Kota stone 15 to 18mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.Note : Quoted rate shall deemed to be inclusive of rendering (as screed bed). |
| 50 | M&L for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 20mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 51 | M&L for 16 to 18 mm thick granite slab (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. |
| 52 | M&L for 75 mm thick plain cement conctere 1:3:6,type C1 (using 20 mm graded crushedstone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed.Note : Plinth protection shall be of width as directed and shall belaid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision. |
| 53 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm gradedcrushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed. |
| 54 | M&L for average 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in levelling course, floors, etc finished fair & even complete all as specified and as directed. |
| 55 | M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work. |
| 56 | M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.Notes: (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work. |
| 57 | M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed.Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work. |
| 58 | M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE. |
| 59 | M&L for machine pressed coloured chequered cement concrete tiles of size 295x295x25 mm thick with grey cement and pigments, set and jointed in neat cement slurry in floors and pointed with coloured cement to match the shade of tiles and laying over & including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.Notes: (i) Quoted rate shall deemed to be inclusive of cement screed. (ii) Colour & design / pattern of tiles shall be got approved from GE before incorporation in the work. |
| 60 | M&L for precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Kerb block (Kerb Stone), factory casted, with plain fair faces, size 10cm x 30cm each or as directed, including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, fixed in position to the required line, level and curvature including making drainage opening wherever required, complete all as specified & as directed.Note : Shape & size of Kerb blocks shall be as approved by the GE. |
| 61 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer\"s instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as \"Supply only\". |
| 62 | M&L for Rendering 20 mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work of walls with WPC mixed @ minimum 2% by weight of cement or as per manufacturer instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as \"Supply only\". |
| 63 | M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed. |
| 64 | M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed. |
| 65 | M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified and as directed. |
| 66 | M&L for preparation of old surfaces of ceilings including scraping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying one coat of white wash complete all as specified and as directed. |
| 67 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed. |
| 68 | M&L for preparation of old decorated surfaces of walls including cornices etc (plastered or unplastered) of any description, rubbing, scrappingby hand held sander / long handle sander and washing and applying one coat of oil emulsion distemper (OBD) of approved shade/tint by mechanicalmeans/ auto roller including filling undulations with white cement based wall care putty mixed with multi purpose mixer complete all as specified and as directed. |
| 69 | M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed. |
| 70 | M&L for preparation of old decorated surfaces of wall including cornices etc (plastered or unplastered)of any description, rubbing, scrappingby hand held sander / long handle sander and washing and applying one coat of cement based paint of approved shade/tint by mechanical means complete all as specified and as directed. |
| 71 | M&L for preparation of old decorated surfaces of walls including cornices etc (plastered or unplastered) of any description, rubbing, scrapping by hand held sander / long handle sander and washing and applying one coat of plastic emulsion paint of approved shade/tint by mechanicalmeans / auto roller including filling undulations with white cement based wall care putty mixed with multi purpose mixer complete all as specified and as directed. |
| 72 | M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over & including 1mm thick water proof wall care putty suitable for exterior surfaces exposed to weather as per manufacturer\"s instructions complete all as specified and as directed. |
| 73 | M&L for preparation of old decorated surfaces of walls including cornices etc (plastered or unplastered) of any description, rubbing, scrapping by hand held sander / long handle sander and Jet pressure washing and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm applied by mechanicalmeans i.e Airless spray complete all as specified and as directed. |
| 74 | M&L for preparation of new concrete/plastered surfaces of Kerb stones, decorative wall and the like and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) in alternate panels in different shade/tint with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer\"s instructions complete all as specified and as directed.Note : Painting to Kerb stones, decorative wall, etc in alternate shade/tint as approved by Engineer-in-Charge shall be carried out. |
| 75 | M&L for two coats of fiber reinforced elastomeric liquid applied waterproofing membrane paint (‘SmartCare Damp Proof’ ofMake ‘Asian Paints’ or equivalent make as approved by GE) over and including self priming coat on existing plastered surfaces including necessary preparation of surfaces complete all as per manufacturer\"s instructions and as directed. |
| 76 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed. |
| 77 | S&F 5mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections exceeding 0.5 Sqm in each pane complete all as specified & as directed. |
| 78 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed. |
| 79 | M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed. |
| 80 | M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed. |
| 81 | S&F in repairs ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe or brass ferrule of 20 mm bore and fixed (minimum weight 210 gms) complete all as specified and as directed.. |
| 82 | S&F in repairs 15 mm bore bib tap long nose with wall flange, fancy type, cast copper alloy, chromium plated, long shank screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. PIS-09 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 83 | S&F in repairs 15 mm bore two way bib tap fancy type, brass, chromium plated with flange and aerator, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. PIS-12 H or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 84 | S&F in repairs CP ABS body Health Faucet with 1 mtr SS Chrome plated tube & hook wall mounted type complete all as specified and as directed.Make:Prayag Cat No. BEA-97 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 85 | S&F in repairs 15 mm bore pillar taps, fancy type, CP cast copper alloy, with capstan heads, with long screwed shanks and fly-nuts, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" screwed for iron pipe complete all as directed. Make : Prayag CatNo PIS-02 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 86 | S&F in repairs 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed. Make: Prayag Cat No. PIS-10 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 87 | S&F in repairs chromium plated 110mm square over head ABS shower with SS Arms & Flange, swivel joints fixing to steel pipes etc complete all as directed. Make : Prayag CatNo BS-72N or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 88 | S&F in repairs grating square 140 mm size of stainless steel and fixed complete all as specified & as directed. |
| 89 | S&F in repairs PVC connections 15mm dia, 450mm long with PTMT nuts & washers at both ends. |
| 90 | S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed. |
| 91 | S&F in repair 110mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 92 | S&F in repair 110mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed. |
| 93 | S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm/ suitable fastener bolts, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed. |
| 94 | S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., complete all as specified & as directed. |
| 95 | S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified and as directed. |
| 96 | S&F in repairs plastic water closet seat, white, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device complete all as directed. |
| 97 | M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore drain pipe complete all as specified and as directed.Note : Drain pipe shall be measured and paid for separately. |
| 98 | All as per serial item No. 97 here-in-above, but for 200mm bore pipe -do- |
| 99 | M&L for Reinforced concrete pipe 150 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed. |
| 100 | M&L for Reinforced concrete pipe 200 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed. |
| 101 | M&L for cutting into existing manholes/Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), reforming benching as required and finishing surface even & smooth for 150mm bore pipe complete all as specified and as directed. |
| 102 | All as per serial item No. 101 here-in-above, but for 200 mm bore pipe -do- |
| 103 | M&L for cement concrete (Quality Concrete) work in pavement/hard-standing of flexural strength 40 Kg per square centimeter in field using 400 Kg of cement per cubic metre, thickness of concrete 25 cm or less,including necessary form work for laying in bays between joints & contraction, expansion joints/or between the two contraction joints, finishing surface of concrete roads, pavements, pavings etc by brooming whilst the concrete is green, complete all as specified & as directed.Notes :-(i) The construction, dummy (contraction) & expansion joints shall be measured separately under respective items.(ii) Design mix shall be approved by GE before execution of the work. In case, quantity of cement as per actual design mix works out less than 400 Kg per cum of concrete, then minimum cement as 400 Kg/Cum of concrete shall be used without any extra cost to Govt. In case cement as per actual design mix is more than the 400 Kg/cum of concrete, the actual quantity as per design mix shall be used in the work without any extra cost to Govt. |
| 104 | M&L for forming Construction joints 30mm deep x 10mm wide, filled with sealing compound Grade \"A\" complete all as specified. |
| 105 | Supply and fixing Cat Eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. \"DA 972\" of make‘DARK EYE’ (or equivalent of make GREENLITE / 3M / TATA BP / Avery Dennison / Alexis / Oscar / DEV / Surya / Sharp Eyez/ Sinor Infrastructure) fixed with and including MS stud of suitable size as per manufacturer’s instructions complete all as specified and as directed including dismantling and taking out old unserviceable / broken road stud / cat eye of any type. |
| 106 | S&F Solar road Stud of size 125mm x 125mm x 25mm (shank 60 mm), aluminium alloy shell, electronically operated automatically turns ON at night and turns OFF at day, high efficiency mono crystalline solar panel 2.4 V / 0.3 Watt, one Ni-Mh or Ni-Cd rechargeable battery (1.2 V / 1600 MA), six super bright LEDs with 10000 to 18000 mcd (Millicandela), view distance upto 1000m, flash rate 2 Hz, capable to withstand weight upto 10 tonne, unbreakable poly carbonate clear facing designed for maintenance free operation, 100% water proof design according to IP-65, Red or Amber colour, complete all as specified and as directed includingdismantling and taking out old unserviceable / broken solar road stud of any type.Note :- Solar road Stud shall be of Model “DA 110 (DHRUV)’ of make‘DARK EYE’ or equivalent of make GREENLITE / 3M / TATA BP / Avery Dennison / Alexis / Oscar / DEV / Surya / Sharp Eyez/ Sinor Infrastructure as approved by GE. |
| 107 | S&F road safety Convex Mirror circular of size 1000mm dia made of one piece polycarbonate lens with hood for road turning, intersection, curves, ‘T’ junction, etc, unbreakable & strong, mounted on & including 2.50 metre long vertical pole made out of 80mm bore mild steel medium grade pipe duly painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide zinc chrome primer, fixed with adjustable clamp, pole fixed in plain cement concrete 1:2:4 Type B1 (using 20mm graded crushed stone aggregate) block of size 450mmx450mmx600mm deep including necessary excavation, RFR & removal in any type of soil, complete all as specified and as directed including dismantling of old unserviceable / broken mirror with pole of any type & size.Make – 3M / Dark Eye / Greenlite / TATA / Avery Dennison / Alexis / Oscar / DEV / Surya / Sharp Eyez / ABS Engineering / Cats eye as approved by GE. Notes : (i) Amild steel base plate of size 250mm x 250mm x 3mmshall be welded at bottom of pole. (ii) All steel & iron surfaces other than powder coated shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide zinc chrome primer. |
| 108 | Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed. |
| 109 | Taking down existing post top lantern of any description and S&F new 45W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj \"BGCTN 45W LED WW\" or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 110 | Taking down existing post top lantern of any description and S&F new 25W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj \"BGCTN 25W LED WW\" or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 111 | Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 50 Watt LED Flood Light fitting, IP-65 rated with high pressure die cast aluminium housing, powder coated, CCT 5700K, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system and testing on completion complete all as directed.Make : Bajaj \"BJFL 50W LED\" or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 112 | Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 150 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed. |
| 113 | Taking down existing bollard light fitting and S&F new 9/10 Watt LED Bollard light fitting with opal PC diffuser and IP-65 protection with inbuilt LED, made in die cast aluminium housing Frosted polycarbonate diffuser, CCT 3000K complete with all standard accessories fixed as per manufacturer\"s instructions and making necessary electrical connections including testing on completion complete all as directed.Make: Bajaj Model \"TULIP\" Cat No. BGBOM 1000 9W LED WW or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 114 | S&F in repairs MCB SP 6 to 32 Amp, 50 Hz, AC supply, 10 kA \"C\" Curve with proper size lugs complete all as directed.Make: Legrand Cat No. 4085 87 to 4085 95 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 115 | S&F in repairs MCB SPN, 16 Amps, 10 kA, \"C\" Curve, 230 Volts, 50 Hz, AC supply including electric connection & testing complete all as specified and as directed. |
| 116 | S&F in repairs MCB TP, 32 Amps, 10 kA, \"C\" Curve, 415 Volts, 50 Hz, AC supply including electric connection & testing complete all as specified and as directed. |
| 117 | S&F in repairs MCB TPN 32 Amp, 415 V, 50 Hz, AC supply, 10 kA \"C\" Curve with proper size lugs complete all as directed. Make: Legrand Cat No. 4086 80 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 118 | S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply, 10 kA \"C\" Curve with proper size lugs complete all as directed. Make: Legrand Cat No. 4086 83 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 119 | S&F in repair Power Contactor, 3 Pole, AC1 rating - 45 Amp, including necessary connections for incoming and outgoing complete all as specified & as directed.Make : L&T Type ML3 Cat No. SS90721 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 120 | S&F in repairs Astro digital time switch, 1 Out put 16 A, 1 channelmounting in existing panel, suitable for switching ON/OFF light and other electric devices according to the rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/or fixed preset times and also suitable for daily astronomical calculation of the sunrise/sunset time based on the entered location or location coordinate complete all as directed. Make: Legrand Cat No. 4126 54 or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 121 | Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 122 | Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 123 | Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 6 sqmm 2 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. |
| 124 | Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed. |
| 125 | M&L for Galvanized iron tubing, 50mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.Note :- Excavation & earthwork shall be measured & paid for separately. |
| 126 | M&L for cutting of existing PCC floor / hardstanding / Interlocking tiles path / WBM road with soling & premix carpet of any description for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed including re-setting of interlocking tiles/ Paver block (where required) complete all as directed. |
| 127 | M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal ofsurplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. |
| 128 | M&L for wiring of panel in Incinerator control panel from Relay and auxiliary contacts complete by using 2.5 sq.mm copper cable of colour code from auxiliary contacts to Relay including fault finding & taking out old wiring etc complete all as specified and as directed. |
| 129 | M&L for painting to various components of incinerator of capacity 10 kg/hr including primary chamber, secondary chamber, Quencher, Venture Scrubber, Packed bed Scrubber motors, blowers and pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of heat resistance spray paint sustain capacity upto 700 degree Celsius over a coat of red oxide primer including marking with radium sticker as per existing type and size complete all as specified and as directed. |
| 130 | S&F in repair heating coil of heating capacity 1050º Celsius, fitted in Primary/ Secondary chamber suitable for 10 kg capacity BMW Incinerator manufactured by M/s Aravali Thermal Power Ltd. |
| 131 | S&F Contactor, 85A, TP, 415 Volts and taking out existing unserviceable contactor including electrical connections complete all as specified and as directed. MakeLegrand/ Schneider/ C&S/ ABB/ Siemens |
| 132 | S&F Contactor, 32A, TP, 415 Volts and taking out existing unserviceable contactor including electrical connections complete all as specified and as directed. MakeLegrand/ Schneider/ C&S/ ABB/ Siemens |
| 133 | S&F in repair MCCB, 4 Pole, 200 Amps, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type including electric connection & testing complete all as specified and as directed. |
| 134 | S&F in repair MCCB, 4 Pole, 160 Amps, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type including electric connection & testing complete all as specified and as directed. |
| 135 | S&F in repair MCCB, 4 Pole, 120 Amps, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type including electric connection & testing complete all as specified and as directed. |
| 136 | S&F in repair MCCB, 4 Pole, 100 Amps, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type including electric connection & testing complete all as specified and as directed. |
| 137 | S&F in repair selector switch in existing panel complete all as directed. |
| 138 | S&F in repairs push botton with LED indicator, 240 V AC colour Red/Yellow/Green. Make: ESBEE or equivalent in TEKNIC / TELEMEACHNIQUE / used by OEM/ makes mentioned in Appendix \"B\" here-in-after. |
| 139 | S&F in repair contactor relays of DC control voltage of 12 Volt type complete all as directed as per site requirement. |
| 140 | S&F in repair electronic timer of 215/240/360/415 Volt 3 to 120 Sec complete all as directed. Make: L&T/C&S/Schneider or equivalent in makes mentioned in Appendix \"B\" here-in-after. |
| 141 | S&F in repair Ammeter, digital type, panel board mounting square type range 0 to 150 and 200 Amps, CT ratio 200/5 complete all as specified & as directed. |
| 142 | S&F in repair Volt meter, digital type, panel board mounting square type range 0 to 500 Volts complete all as specified & as directed. |
| 143 | S&F in repairs 4 Sqmm 3 core PVC insulated, PVC Sheathed, multistranded copper conductor flexible cable of 1100 Volt grade (ISI marked) with suitable lugs etc complete all as specified & as directed. |
| 144 | M&L for comprehensive maintenance and repairs of micro processor based controlled VVV frequency drive, electric driven Lift with ARD, Goods lift of capacity 1000 Kgs. installed at Dwarka Building serving ground plus 2 floors incl examining, adjusting, lubricating, greasing and replacement of u/s parts like hooter, fire switches, indication, emergency light, low voltage relay complete all as directed by Engineer-in-Charge.Note: (i) Comprehensive maintenance, repair and replacement of all spare parts and components fitted by KONE will be original parts or components fitted will be of equal quality and functionality as on when required shall be carried out only through authorised service agency of OEM under strict supervision of well experienced and qualified staff.(ii) The make of spares shall be shown as suitable for the existing system and shall be provided by authorized manufacturer\"s.(iii) The rates deemed to includes for all items which are not considered in schedule but the same is essential for smooth & efficient functioning of the lift costing less then Rs 400/- i.e. fuse, thumbles, connectors etc.(iv) The contractor shall keep all spares reqd for unserviceable spares parts replacedwill be properties of the OEM and also the routine maintenance and attend the defects immediately. In case of major defects it shall be attended within 24 hrs failing which penal recovery @ 1000/- per day will be charged.The decision of GE will be final & binding in this regard. |
| 145 | Item No. 144 Contd/-(v) The total Nos of Visit for normal servicing in general basis are 11 Nos (Monthly basis) and also Breakdown service covered during normal working hours(vi) spares parts listed in item No.36 to 42 will be measured and paid under relevant items separately as ordered.(vii) Contractor will be liable for defective unserviceable provide below mentioned items Sl No. (a) to (w) as and when required for maintenence of Lift or in breakdown condition for smooth & efficient functioning of Lift as per OEM requirement . The rates of spares & fitting deemed to be included in the quoted rates.(a) Drive module, KDL16R 20A 400V(b) LCECCBe Assembly(c) PCB, LCECPU NC Board V3F18(d) ENCODER, MX D37.3 L2=4500(e) Land Operating Panel, LOP-CB Assembly(f) LCE PCB Assembly(g) LCE CEB assembly(h) LCE COB Assembly(j) LCECIB,New LON Protocol. (k) Pit switch Sssembly, 1 NC 230VAC(l) UPS Device, 600VA 230V 1 PH (m) PCB,LOP230 Saftey Chain interface 1.2 |
| 146 | Item No. 144 Contd/-(n) AMD D10 Motor assembly (o)AMD D10 Spare Module ( Parallel ) - G03(p) AVD7S assembly (q)Transformer, Drive 1 230V, 50/60HZ(r) Switch Contact, Slack rope Device(s) Switch Door contact 230VAC 2A(t)Tension weight, swing Arm OL35 (u)TL Jones Curtain of Light(v) Toothed Belt, Drive1 W = 12mm (w)Pully, Toothed belt D38.8mm W = 19.8mm |
| 147 | Supply and Fix in repair ARD batteries 7 AH 12 Volts |
| 148 | S&F in repair ELCB 4 Pole three phase, 40 Amps 415 V, 50Hzof breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed |
| 149 | S&F in repair ELCB 2 Pole single phase, 25 Amps 230 V, 50Hzof breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed |
| 150 | S&F in repairCar Blower Fan single phase supply 230 V ,50Hz for 1000 Kg capacity Lift all as specified and directed |
| 151 | S&F in repairCar LED Light single phase supply 230 V ,50Hz for 1000 Kg capacity Lift all as specified and directed |
| 152 | M&L for comprehensive maintenance and repairs of Automatic Rescue Device process based controlled ACVVF drive control, stainless steel mirror finish, simplex collective selective control system electric driven Passenger lift, 6 passenger maximum of capacity 408 kgs, speed 1.00 mtr/ sec, Model - Meta 100 MRL of Make - Thyssenkrupp (TK Elevator), serving ground plus 1 floor including examining, adjusting, lubricating, greasing and replacement of unserviceable parts like hooter, fire switches, indication, emergency light, low voltage relay complete all as directed by Engineer-in-Charge.Note: (i) Comprehensive maintenance, repair and replacement of all spare parts and components fitted by TK Elevator will be original parts or components fitted will be of equal quality and functionality as on when required shall be carried out only through authorised service agency of OEM under strict supervision of well experienced and qualified staff.(ii) The make of spares shall be shown as suitable for the existing system and shall be provided by authorized manufacturer\"s.(iii) The rates deemed to include for all items which are not considered in schedule but the same is essential for smooth & efficient functioning of the lift costing less then Rs. 400/- i.e. fuse, thumbles, connectors etc.(iv) The contractor shall keep all spares required for unserviceable spares parts replaced will be properties of the OEM and also the routine maintenance and attend the defects immediately. In case of major defects it shall be attended within 24 hrs failing which penal recovery @ 1000/- per day will be charged.The decision of GE will be final & binding in this regard. |
| 153 | Item No. 150 Contd/-(v) The total Nos of Visit for normal servicing in general basis are 11 Nos (Monthly basis) and also Breakdown service covered during normal working hours.(vi) Spares parts listed here-in-after under relevant items will be measured and paid under relevant items separately as ordered.(vii) Contractor will be liable to provide items as and when required for maintenance of Lift or in breakdown condition for smooth & efficient functioning of Lift as per OEM requirement. The rates of spares & fitting deemed to be included in the quoted rates. |
| 154 | Supply and Fix in repair ARD batteries 6 AH 12 Volts |
| 155 | S&F in repair ELCB 4 Pole three phase, 32 Amps 415 V, 50Hzof breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed |
| 156 | S&F in repair ELCB 2 Pole single phase, 16 Amps 230 V, 50Hzof breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed |
| 157 | S&F in repairCar Blower Fan single phase supply 230 V ,50Hz for 408 Kg capacity Lift all as specified and directed |
| 158 | S&F in repairCar LED Light single phase supply 230 V ,50Hz for 408 Kg capacity Lift all as specified and directed |
| 159 | M&L for carried out water testing report as per IS-10500:2012 with all required water container by Govt Authorised laboratory and submit Bactriological & Chemical report for 02 Nos. Sample (i.e. RO Plant Water & Potable Water) |
| 160 | M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing. |
| 161 | S&F in repairs 10mm thick chequered type insulating electrical rubber mat of size 4 x 8 ft (ISI Marked) complete all as specified & as directed. |
| 162 | M&L for Distribution Chart of Electric Supply System of size 150cm x 90cm made of 3mm thick PVC/ Acrylic sheet, chart prepared and painted with different colour code as directed by Engineer-in-Charge, with suitable aluminium framing, fixed on wall with appropriate screws, complete all as directed.Note :Letters/matter etc for Distribution Chart shall be given by the Engineer-in-Charge. The lettering font & style, layout of electric supply lines, etc shall be as directed by Engineer-in-Charge. |
| 163 | M&L for Glow sign board of size 2.00m x 1.00m x 0.15m, out door type, totally enclosed with locking arrangement, front side made of 5mm thick milky white / coloured acrylic sheet with letters/matter/logo/sign by overlay colour film (colour as approved by Engineer-in-Charge) pasted over sheet, all other box work made out of 22 gauge thick galvanized iron sheet and 40mm x 40mm x 5mm MS angle iron frame work, with & including suitable LED light fittings 1x10 watt - 4 Nos, prewired, with & including all standard accessories as per standard trade practice including making electric connections with suitable size multistranded copper conductor cable, including two coats of synthetic enamel painting of approved tint over a coat of zinc chrome primer after preparation of steel surfaces of MS frame work, fixed on Padestal/wall/Gate placed over parapet/chajja etc or other location by grouting/placing appropriately as directed by Engineer-in-Charge, complete all as specified & as directed.Note :Letters/matter/logo/sign etc for sign board shall be given by the Engineer-in-Charge as per location of sign board. The lettering font & style, lightning work, etc shall be as directed by Engineer-in-Charge. |
| 164 | S&F Galvanized Mild Steel fire bucket of 10 litre capacity conforming to IS 2545, Mild steel black sheets used to be conforming to Grade st 34 or Grade st 42 of IS 1079, mild steel rod used for top and bottom handle confirming to IS 226, mild steel wire used stiffening top rim confirming to IS 280, Bucket shall be stamped or embossed on its side with the manufacturer and its capacity, duly painted with two coats of synthetic enamel paint (outer surfaces in Red Colour & inner surfaces in White Colour) over a coat of red oxide zinc chrome primer all as per the relevant IS code complete all as specified & as directed. |
| 165 | S&F fie bucket stand of load bearing capacity 50 kg for holding fire buckets 4 Nos. filled with water or sand and stand made up of MS angle 50 x 50 x 6mm of size 6\"x5\"x3\", 18 SWG MS sheet, duly painted with two coats of synthetic enamel paint (Red Colour) over a coat of red oxide zinc chrome primer all as per the relevant IS code complete all as specified & as directed. |
| 166 | Taking up or down old rusted/ worn out GItubing & connections of 15 mm bore fixed in any position and S&F new 15 mm bore galvanized steel water tubing medium grade (ISI Marked) with & including all necessary fittings (ISI Marked) such as bend, tee, elbow, etc laid in trenches/ floors or fixed on wall and ceiling complete all as specified and as directed. Note : Excavation & earthwork shall be measured & paid for separately. |
| 167 | All as per serial item No. 163 here in above but 20 mm bore. |
| 168 | All as per serial item No. 163 here in above but 25 mm bore. |
| 169 | All as per serial item No. 163 here in above but 40 mm bore. |
| 170 | All as per serial item No. 163 here in above but 50 mm bore. |
| 171 | All as per serial item No. 163 here in above but 80 mm bore. |
| 172 | S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed. |
| 173 | S&F in repairs 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed. |
| 174 | S&F in repairs 40mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed. |
| 175 | S&F in repairs 50mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed. |
| 176 | Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete all as specified & as directed. |
| 177 | Attending day to day water supply complaints such as no water supply/ low water supply and water leakage from GI tubing/ UPVC (Sch 80) Pipes & fittings/fixtures of 15 mm to 25 mm bore by checking the nature of defects and rectification work to be carried out by replacing requisite materials, testing complete on completion of work, excavating in any type of soil, returning, filling and disposal of surplus soil if any as directed. Notes : (i) Material such as GI tubing/ UPVC (Sch 80) Pipes & fittings, valve, etc and excavation/ earth work required for rectification work shall be measured and paid under relevant items.(ii) Excavation & earth work required for rectification work shall be measured and paid under relevant items.(iii) Minor stores such as washers, taflon tape, small size nuts, bolts, clamps, etc shall be provided by the contractor and cost thereof shall be inclusive in quoted rates. The decision of Accepting Officer will be final and binding regarding extent to which the items can be considered as minor.(iv) Requisite T&P and transportation for tradesman to rectify the defects shall be contractor’s responsibility.(v) The contractor / his representative shall collect the complaint slip from MES complaint cell / concerned JE E/M every day at 9.00 AM and deposit the complaint slip duly signed by the users to concerned JE E/M after rectification of complaint. |
| 178 | All as per serial item No. 174 here in above but for 40mm to 50mm bore. |
| 179 | All as per serial item No. 174 here in above but for 80mm to 100mm bore |
| 180 | M&L for construction of Valve Chamber of internal size 1200x1200x1200mm including necessary excavation & earth work in any type of soil, 150mm thick PCC 1:4:8 type D2 in foundation extended 150mm alround beyond external face of walls, 230mm thick brick work with old size fly ash bricks in CM 1:4, 15 mm thick plaster in CM 1:4internally and externally flush pointed in same mortar as work proceeds, 150 mm thick PCC coping all round in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) over walls, flooring shall be 40 mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate.Top cover shall be made out of MS sheet 3.00 mm thick fixed in angle iron frame made out of angle iron size 40x40x6 mm with two number of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed including dismantling of old existing unserviceable vale pit chamber.Note : Any minor modification where required at site shall be deemed to be included in the quoted rates. The decision of GE shall be final and binding regarding extent to which the change can be considered as minor. |
| 181 | All as per serial item No. 177 here-in-above but of internal size 900x900x900 mm -do- |
| 182 | All as per serial item No. 177 here-in-above but of internal size 600x600x600 mm -do- |
| 183 | M&L for removing of Window/ Split type AC unit 1.0/ 1.5 / 2.0 TR capacity of any make from existing position and servicing the same by complete cleaning the dust including supply and replacement of damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor by oiling/ greasing, changing of damaged knobs, painting the old painted surfaces with one coat of synthetic enamel paint, setting of grills alignment complete including refixing in original position, testing & commissioning all as directed. |
| 184 | M&L for taking out rotary type compressor unit (uncut) from the split type Air Conditioner of any make, 1 ton capacity and replacing the sealed unit as per existing model with reconditioned sealed unit including the following all as specified and as directed. (a) Connection to suction/ discharge pipe with necessary repair and brazing.(b) Replacing the capillary tubes of existing size and copper liquid filter.(c) Flushing of entire system before gas charging.(d) Gas charging and testing after complete replacement including installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed. |
| 185 | All as per item No. 181 here-in-above, but for 1.5 ton capacity. |
| 186 | M&L for taking out Condenser unit from the split type Air Conditioner of any make and type,1.0 ton capacity and replacing the same with copper Condenser unit including necessary connection and testing after complete replacement as specified and as directed. |
| 187 | All as per item No. 183 here-in-above, but for 1.5 ton capacity. |
| 188 | S&F in repair fan motor suitable for Split Air Conditioner of capacity 1.0/ 1.5/ 2.0 ton complete all as directed. |
| 189 | S&F in repair blower motor suitable for Split Air Conditioner of capacity 1.0/ 1.5/ 2.0 ton complete all as specified and as directed. Make: Suitable for carrier /Voltas /LG /Blue star/ Amtrex spilt AC as per manufacturers make. |
| 190 | M&L for taking out defective burnt fan motor from the Split/ Window Air Conditioner of capacity 1.0/ 1.5/ 2.0 Ton, dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding, over hauling the motor by replacing the clamps, nuts, bolts and rubber rag etc for smooth working of motor, re-assembling the motor and testing the motor at medium and full load complete all as directed. |
| 191 | S&F in repair blower for 1.0/1.5/2.0 ton capacity split Air Conditioner/ Inverter type Split Air Conditioner complete all as directed. Make: Suitable for carrier/ Voltas/ LG/ Blue star/ Amtrex spilt AC as per manufacturers make. |
| 192 | S&F in repair overload protector relay suitable for Window type AC of 1.5/ 2.0ton capacity including necessary electric connections, lugs, insulation tape etc complete all as specified and as directed. Make: AEI/ Shriram or make as approved by GE. |
| 193 | S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one single pole MCB 20 Amps, \"C\" Curve complete all as directed. |
| 194 | S&F in repair remote circuit suitable for split type AC 1.0/1.5/2.0 Ton capacity as per existing make/ model complete all as specified and as directed. |
| 195 | S&F in repair of air filter set suitable for split type AC of 1.0/ 1.5/ 2.0 tone capacity of any make and type complete all as specified and as directed. |
| 196 | S&F in repair of swing motor for 1.0/1.5/2.0 ton capacity split type AC of different types and makes, Each make of motor shall be same as original complete all as specified and as directed. |
| 197 | S&F in repair Fan Blade suitable for split type AC of capacity 1.0/1.5/2.0 ton complete all as directed. |
| 198 | S&F in repair contactor for split type AC, 1.0/ 1.5/ 2 Ton capacity as per existing make and capacity/ model etc complete all as directed. |
| 199 | S&F in repair of PVC drain pipe of 15 mm dia 1.5 mtr length suitable for Split AC 1.0/ 1.5/ 2.0 ton capacity including necessary connection and fittings etc complete all as specified and as directed. |
| 200 | S&F in repair factory made MS powder coated stand for outdoor unit of split type AC 1.0/ 1.5/ 2.0 ton capacity complete all as specified and as directed. |
| 201 | S&F in repair service valve suitable for split AC of capacity 1.0/ 1.5/ 2.0 ton complete all as specified and as directed. |
| 202 | S&F in repair suitable size insulated copper tubings (suction line & liquid line) suitable for 1.0/ 1.5/ 2.0 TR capacity split AC all as per AC manufacturer’s recommendation complete all as specified and as directed.Note :-01 run of suction line copper tube & 01 run of liquid line copper tube and insulation shall be measured as one run length for payment purpose. |
| 203 | M&L for taking out Split type Air Conditioner of capacity 1.0/ 1.5/ 2.0 ton and re-fixing the same in existing or new location as directed by Engineer-in-Charge including making opening in the wall by cutting drilling, hammering the wall for placing ducts, pipes etc. and making good to match with existings specification and testing the same after re-fixing complete all as directed. |
| 204 | Supplying and charging refrigeration gas F-22 or R-22 including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed. |
| 205 | Supplying and charging refrigeration gas R-32 including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed. |
| 206 | Supplying and charging refrigeration gas R-410 including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail