| 1 | M & Lbrick work with sub class \"B\" bricks straight or curved on plan exc 6 m mean radius built inCM1 : 6 including demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar complete all as specified and as directed. |
| 2 | M&L for cutting chasesin brick walls, pinning in, making good to facings where required and pointing in CM 1 : 3 to ends, or edges of landings steps, cills, and cutting chases for concealed water tubing or conduit wiring etc and making good cutting excedding 20 cm girth complete all as specified and directed. |
| 3 | S&F mild steel in joist channel, angle or T section, fixed independently, without connecting plate ect (cut to ordenary length i.e, within 20mm of the length indicated). of Gde Fe 410-W (Gde- E-250) Qty-A including dismantling of old iron scrap complete all as specified. |
| 4 | S & F Rolled sections as in main & cross beams, hip & jack rafters, purlins where connected to common rafters & running rails & guides for sliding doors, fixed with angles cleats or other connecting plates conforming to Fe-410-W (Gde E-250) Quality A including dismantling of old iron scrap complete all as specified and directed. |
| 5 | S&F in repair Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified. |
| 6 | S&F in repair Pre-Painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, ridges etc fixed with self tapping screws complete all as specified. |
| 7 | S &F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; largehasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as specified and directed |
| 8 | M & L for preparation of newly steel surface of any description over 10cm width or girth, not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 9 | M & L 15 mm thick rendering on fair faces of brick work or concrete surface in cm 1:4 to be finished even and smooth withoutusing extra cement and including WPC @ 3% total weight of cement including taking down cement plaster from brick walls including raking out joints, hacking for key, scrubbing down with water to receive plaster removal of rubbish off the premises etc. Note: WPC should be measured & paid Separately. |
| 10 | M & L 10 mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 as in internal walls to be finished even and smooth withoutusing extra cement . |
| 11 | M&L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper on walls over a coat of 1mm thick wall care putty, complete all as specified and directed. Note : Contractor shall obtain approval of Engr-in-charge before carry out OBD over putty. No work shall be carry without obtainning approval of Engr-in-charge after execution of putty work. |
| 12 | M&L for Preparing newly plastered surfaces of walls and applying two coats of Acrylic smooth exterior paint of required shade (Two or More coat applied @ 1.67ltr/10Sqm and including priming coat of exterior primer applied @ 2.20Kg/10Sqm) complete all as specified and directed. |
| 13 | M & L for preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified. |
| 14 | M & L for preparing old decorated surfaces of walls and and applying two coats of Acrylic smooth exterior paint of required shade : (Two or More coat applied @ 1.67ltr/10Sqm and including priming coat of exterior primer applied @ 2.20Kg/10Sqm) complete all as specified. |
| 15 | M&L for 40mm thick cement concrete type B0 using 12.5 mm graded aggregate in floors including demolition of cement concrete of any description in any position, concrete filling as in sunken floor complete all as specified and directed. |
| 16 | M &LPCC1:7:12 typeF 2with bricks as infillingofsunken slab after laying carrying out required tests for CI pipes joints WPT including demolition of cement concrete of any description in any position, concrete filling as in sunken floor complete all as specified and directed. |
| 17 | M&L for Roughening surfaces of old concrete by sweepping clean and washing downwith water to remove dust complete all as specified & directed. |
| 18 | M&L for 15mm thick rendering in in fair faces of brickwork CM 1:3 withfinishing the surfaceseven and smooth without using extra cement complete all as specified & directed. |
| 19 | M&L for applying two coats of hotbitumen 85/25 grade @ 1.70 Kg/Sqm over vertical surfaces and floor of sunken slab after laying all CI connection branch pieces etc after covering joints with PCC 1:2:4 mixed with WPC complete all as specified & directed. |
| 20 | S&F GI spouts 40mm dia projecting atleast 10 cm clear of the wall. |
| 21 | Supply only intergal water proofing compound complete all as specified and directed by Engr-in-Charge |
| 22 | S & F in repairs110 mm dia, PVC (SWR) single socketed rain water pipe in any length with rubber ring joints fixed to walls complete all as specified and directed |
| 23 | S & F in repairs 75 mm dia, PVC (SWR) single socketed rain water pipe in any length with rubber ring joints fixed to walls complete all as specified and directed |
| 24 | S&F110mm bore PVC (SWR) branch pipe, single Y equal or unequal with access door complete all as specified. |
| 25 | S&F 75mm bore PVC (SWR) branch pipe, Double Y equal or unequal with access door complete all as specified and directed. |
| 26 | S & F 110 mm bore PVC (SWR) bend of any radius complete all as specified and directed. |
| 27 | S & F 75 mm dia, PVC bend of any radius complete all as specified and directed. |
| 28 | S & FPVC ( SWR ) vent cowl 110 mm bore complete all as specified and directed. |
| 29 | M&L for rendering 10 mm thick plaster in cement mortar (1:4) on concrete surfaces such as chajjas, roof slab,finishing the surfaces even and smooth, mixed with integral water proofing compound @ 2% by total weight of cement, Preparing & cleaning of fully dried cement plastered surface and preparation ofplastered surface of roofincluding cleaning the surface by using wire brush/ pressure hose and applying high performance polyurethane liquid membrane roof casting cold applied in two coats @ 1.5 Kg/Sqm applied with spray/brush an elongation of 300% to 700%and tensile strength of not less than 3N/Sqmm as per ASTM D412 and ASTM D2370, crack bridging ability of 3.5 mm as per ASTM C 1305, shore a hardness of not less than 60as ASTM D 2240. The item includes epoxy prime applied @ 0.15 Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet complete as per manufacturer\"s instructions and sound engineering practice, including taking down/scraping out existing old tarfelt bituminous compound including sweeping, cleaning, washing down to remove dust etc and removing debris to outside defence landcomplete all as specified as directed. (NOTE :- WPC shall be measured and paid separately.)Note- (a) Before roof treatment work, all GI pipes, tanks, solar water heater equiptments etc will be removed/dismantled properly and will be fixed in same position after roof treatment work and cost will be deemed to included in quoted rate and no extra amount will be paid on this account. (b) The work will be executed upto max height of 03 storey building, cost of scafolding to be deemed to be in quoted rate and no extra payment will be made on this account. |
| 30 | M&L for PCC (1:2:4) type Bo using 20 mm graded stone aggregates mixed with integral waterproofing chemical PIDI PROOF-LW mixed in proportion of 200ML/50Kg cemet of DR fixit of pidilite industries Ltd or STP No.1 (Liquid)of STP Ltd in proportion 200ML/50Kg cement as in padding on roof surfaces for correcting /making proper slope on roof, chajjas, roof kerbs/benching rounded or chamfered on edges including use and waste on form work surface finished fair and even without using extra cement complete all as specified and directed. Note- (a) Before roof treatment work, all GI pipes, tanks, solar water heater equiptments etc will be removed/dismantled properly and will be fixed in same position after roof treatment work and cost will be deemed to included in quoted rate and no extra amount will be paid on this account. (b) The work will be executed upto max height of 03 storey building, cost of scafolding to be deemed to be in quoted rate and no extra payment will be made on this account. |
| 31 | S & F in repair vitreous china squatting pan \"orissa\" pattern, size580 x 440 mm white , with integral foot rests (excluding flushing cistern and flush pipe)incl connection to trap, and to flushing pipe, anti syphonage pipe, etc complete incl making good to floor. |
| 32 | S & F of Stack clamps out of 50 mm by 5mm flat iron and 16 mm diaround iron stays, incl bolts and nuts and securing ends of stays to wall or roof for 75/110 mm bore pipe complete all as specified and directed. |
| 33 | S & F in repairCI nahani trap dia of outlet 75mm ISI marked having wt not less than 6.5 Kgs including joining to waste pipe fixed in cement concrete (1:2:4) typeB-1 with cementslurry/jute yarn etc complete and testing for water tightness, complete all as specified and directed. |
| 34 | M&L Non - skid Ceramic Colured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 15mm thick CM 1:6 complete all as specified and directed. |
| 35 | S & F of polished kota stone slab of size 250 x 250 x 20 mm thick in corner shelves including fixing, cutting and moulding complete all as specified and directed. |
| 36 | GI wire netting 0.90 mm dia and 12 mm mesh lathing to wall, ceilings, incl all laps, cutting and wastes in patches complete all as specified and directed. |