| Sl. No. | Item Description |
| 1 | Demolition / taking down of existing old tarfelt , water proofing membrane, water proofing plaster of any description any type over RCC roof including any roof tiles, cement mortar screed, concrete screed of any thickness, for fixing of angle iron for water tank postion, complete all as specified and as directed. |
| 2 | 15mm thick Scread bed on roof / concrete surfaces incl parapet etc in cement mortar 1:3 and finished even and smooth without using extra cementand mixed with waterproofing compound as per manufacturers instructions. (Note. WPC shall be measured and paid separately). |
| 3 | Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement) |
| 4 | Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course: Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course :APP (Atactic Polypropylene) modified polymeric membrane, 5 layered,3 mm thick weight not less than 3.0 Kg/Sqm with 150 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions.(ii) Covered fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).Note : (i) Quoted rates are inclusive of all of the above work.(ii) Water proofing treatment shall only be carried out by the authorised personal of the Company and proper record of the same shall be maintained. |
| 5 | Sunken Floor treatment :- Taking down old treatment/ floor tiles/ PCC and Providing & laying of water proofing treatmentto sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementitious composite compound of make as approved including demolition and filling of sunken floor.(a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours.(b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/ Sqm his layer allowed to air cure for 4 Hours.(c). 50mm thick PCC at the bottom of slab and slopeshall be 1:20 toward the corner of outer wall and GI pipe of 50mm dia (Med grade) be inserted at corner projecting outside 20 cm . (d).15 mm thick plaster in CM 1:3 mixed with WP Compound shall be provided while concrete is green.(e) Joints of trap/WC/Soil pipes shall be properly sealed with sealing compound.Note :- (i). Concrete for sunken slabs shall be mixed with WP compounds asmanufacturdrs instructions before carrying out water proofing treatment the sunken slabslab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested (Water proof compound rate will not be paid separately).(ii).Only floor area shall be measured for payment purpose.(iii). Treatment shall only be done from approved manufacturer & name of manufacturer required to be approved from GE before treatment. |
| 6 | Plain Cement Concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as inroof kerb, padding , finished surface even and fair,complete all as specified and directed. |
| 7 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed. |
| 8 | Dismantling of timber scantling in framed work 40sqcm and over in section, as in any position, complete all as specified & directed. |
| 9 | Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed. |
| 10 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed. |
| 11 | Dismantling of timber scantling in fillets, rails, posts, rafters, purlins, etc under 40sqcm in section, as in any position, complete all as specified & directed. |
| 12 | Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality \"A\" complete all as specified and as directed. |
| 13 | Mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, and similar works, complete all as specfied. |
| 14 | Pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 15 | Pre-painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified and as directed. |
| 16 | GI frame work with size of grid 605 x 605mm for ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centreintermediate channel 0.9mm thick having two equal flanges of 15mm each web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including celing section (n.exc 1.2m length) of 0.55mm thickness having kruled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 centre to centre with support of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and complete all as specified and directed. |
| 17 | Non asbestos fibre cement building boards 4mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws, complete all as speciified and directed. |
| 18 | Demolition of brick work or stone boulder masonarybuilt in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed. |
| 19 | Brick work with old size sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified. |
| 20 | Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified. |
| 21 | Taking down cement plaster of any description including raking outjoints, hacking for key, scrubbing down with water etccomplete all as specified and directed. |
| 22 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises,complete all as specified. |
| 23 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished the surface even and smooth without using extra cement, complete all as specified & directed. |
| 24 | Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 25 | Rendering 15mm thick in cement mortar (1:6) on fair faces of the brick work or cement concrete surfaces, finishing the surface even and smooth without using extra cement, complete all as specified. |
| 26 | Preparation of newly plastered surfaces of walls and applyingtwo coat of oil bound distemper over one coat of primer on plastered surfaces, complete all as specified and directed. |
| 27 | Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified. |
| 28 | Preparation of old plastered surfaces on walls and applying two coats of oil bound distemper completeall as specified and directed. |
| 29 | Preparation of old plastered surfaces of ceiling and applying two coats of white wash, complete all as specified. |
| 30 | Preparation of old painted surfaces with complete removal ofexisting treatment & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm old surefaces of walls complete all as specified and directed. (i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/(ii) The work may be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same. |
| 31 | Preparation of newly plastered surfaces & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed.(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/(ii) The work may be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same. |
| 32 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed. |
| 33 | -Ditto- all as srl item No 32 above but reinforced as in chajjas shelves, roof slab and cover slab etc., reinforcement cut to facilitate demolition. |
| 34 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over with mirror cut polishing 100mm wide marble patti/border all around over and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed.Note:-(Size of Kota Stone slab shall be 52 cm x 52 cm). |
| 35 | -Ditto all as per item No 34here-in-beforebut in skirting/dado incl 10mm thick rendering CM 1:4 complete all as specified and directed. |
| 36 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc.set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15 mm thick screed bed in cement and sand mortar 1:4,complete all as specified and directed. |
| 37 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc.set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15 mm thick screed bed in cement and sand mortar 1:6,complete all as specified and directed. |
| 38 | Ditto all as per Item No 37 here-in-before but as skirting including 10mm thick plaster in CM 1:6 complete all as specified and directed. |
| 39 | Glazed ceramic coloured tiles 450x300x7mm thick on vertical surfaces such as skirting, dados and risers to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick rendering in CM 1:4 finished even and fair to receive tiles, complete all as specified and directed. |
| 40 | Granite flooring (of any type) 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, moulding & polishing laid over & including 15mm thick screed bed in CM 1:4, complete all as specified. |
| 41 | Providing cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate), 50 mm thickas in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight), complete all as specified and as directed. |
| 42 | 25mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base/ floor finishing surface even and fair, complete all as specified. |
| 43 | Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:4including formwork/scaffolding work upto height 7.00mtr & applying two coats of exterior emulsion weather proof paint (Apex) as reqd over one coat of primer above ground level of bldg complete all as specified and as directed. |
| 44 | RCC (1:2:4) type B-0 (using 12.5mm graded aggregate) as in Chajjas and Balcony/Landing work if any complte all as specified. |
| 45 | Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including supports, overhangs, etc. complete all as specified and directed. |
| 46 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified. |
| 47 | Reinforced cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate ) as inslabs supported on walls, beams and columns in floor,roofs,landings,balconies,canopies,shelves, deck slabs and in similar works, complete all as specified . |
| 48 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Vertical , Horizontal or sloping)sidesincluding sup- ports, overhangs,for fair finished surface of concrete etc. complete all as specified and directed. |
| 49 | Taking down chowkhats or frameswith shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed. |
| 50 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each complete all as specified and as directed. |
| 51 | Taking down shutters of any description nexc 01 sqm each, complete all as specified and directed. |
| 52 | Mild steel framed workas in door or gate of angle or other section with gusset plate, rail braces complete drilled for fixing of steel sheeting or other covering . door etc to be prepared for hanging of sliding with grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed . |
| 53 | Pressed steel frames for doors with one or more rebates of size 125x60mm including necessary fixing lugs, hinges, lock strike plates complete, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed. |
| 54 | Pressed steel frames for doors with one or more rebates of size 105x60mm including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed. |
| 55 | PCC 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in filling of roof kerbs or pressed steel frame as inparapet coping, roof kerbs or in lintels upto 1.5 m clear span, cills, plinth courses, string courses, coping, kneelers etcall as specified and directed. |
| 56 | Plain Cement Concrete 1:3:6, type C-1 (using20 mm graded crushed stone aggregate), for fixing of hold fast, copings, plinth bands bed blocks kerb or mud stops,rounded or chamfered angles and edges, including necessary form work complete all as specified and directed. |
| 57 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing, complete all as specified and directed. |
| 58 | Factory made solid panel PVC door shutter/ cupboard shutter/ kitchen cabinets 30mm thick style wooden texture consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading andjointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed. |
| 59 | 35 mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 199 (Part-I).Flush door shutter shall be internally lipped as per clause 8.52.2 of SSR-2009 Part-I complete all asspecified and directed. |
| 60 | 35mm thick 2nd class hard wood Glazed and Skeleton shutters, open rebated and prepared to receive glass, gauge etc devided into square with sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed. |
| 61 | Pre laminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter, 12 mm thick. (Kitchen cup board/covered bottom shelf of cooking platform) fixed in repairs complete all as specified and directed. |
| 62 | Pre-laminated particle board, exterior grade, laminated on one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame and necessary item like hasp and staple , in repairs as cupboard/Alimirahshelve and shutter, 18/19 mm thick, complete all as specified. |
| 63 | External teak wood lipping 6 mm thick fixed with nails for 18/19 mm thick board, complete all as specified. |
| 64 | 03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and as directed. |
| 65 | 04mm thick figured (frosted) glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and as directed. |
| 66 | Galvanised mild steel wire cloth 0.56 nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire staples, complete all as specified. |
| 67 | Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed. |
| 68 | 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed. |
| 69 | Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and as directed. |
| 70 | 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and as directed. |
| 71 | 300mm Mild steel ordinary rat tail helical door springs including roller and roller plate fixed, complete all as specified. |
| 72 | Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length of cover plate 150mm , all as specified and directed. |
| 73 | Curtain rod ,20 mm dia Stainless steel ,chromium platedfixed with CP bracket, incl taking down of old curtain rods, complete all as specified. |
| 74 | Steel windows glass/gauzedshutters (Box type) factory madeof size 79mmx39mm,16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1517/15 Sh No 1/1 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item |
| 75 | Factory made box type steel ventilators top hung shutter shutters glass/glazed including guard bars ,hinges,steel handle,tower bolt and steel peg stay,complete with or without glazing bars ,devotiled or welded,including one coat of red oxide primer complete shown as drawing No (CEUZ/TD/1517/15 Sh No 1/3 to 3/3) |
| 76 | Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 77 | Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paintof Ist quality over a coat of pink primer,complete, all as specified. |
| 78 | Vitreous china squatting pan \"Orissa Pattern\" size 580 x 440 mmin white colour with integral foot rest incl lime mortor, \"P\" trap fixed in repairs, incl making good dismantled floor with PCC 1:2:4 B-0, complete all as specified and directed. |
| 79 | PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed. |
| 80 | Vitreous china wash basin, white, flat back, size 550x400mm including waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets and waste pipe etc., fixed in repairs complete all as specified and as directed. |
| 81 | Vitreous china wash down water closet pan pedestal pattern in white colour with \"P\" or \"S\" traps excluding seat cover, flushing cistern and flush pipe fixed in repairs complete all as specified and directed. |
| 82 | CP central hole basin mixer with popup waste system with 450mm long braided hoses (15mm cartridge size) fixed in repairs all as specified. |
| 83 | Supply only PVC connection 15mm size with PTMT nuts on both ends of length 600mm |
| 84 | S & F in repair CP angle valve/stop cock (weight not less than 0.40Kg of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore complete all as specified and directed. |
| 85 | S & F in repair 15 mm CP Bib taps (Long body and weight not less than 0.40Kgfancy type chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 86 | Brass chromium plated fancy type wall mixture for mixing of hot and cold water supply screwed down includingconnecting leg & wall flange for iron pipe 15 mm bore fixed in repaircomplete all as specified and as directed. |
| 87 | Corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf with chromium plated bracket guard complete all as specified and directed. |
| 88 | Chromium Plated stainless steel towel rail 20mm dia \"D\" type 60 cm longbetween flanges complete all as specified and directed. |
| 89 | Brass chromium plated shower rose 125mm sizewith or without swivel joints, with arm any size, including fixing to steel pipe or union complete all as specified and directed |
| 90 | 600mm x 450mm size bevelled edge mirror with border, selected quality 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 91 | Vitreous china Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), with brass grating and union for discharge pipe fixed in repairs, complete all as specified. |
| 92 | Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed. |
| 93 | Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed. |
| 94 | Mild steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 95 | Mild steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 96 | Dismantling water tanks and removing to storeof cap exc 500 but n.exc 1000 ltr all as specified. |
| 97 | Rotational moulded polyethylene 03 layer water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed. |
| 98 | Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms) complete all as specified. |
| 99 | 20mm bore gun metal glove or gate valve with iron wheel head screwed both end for iron pipe and fixed in repairs,complete all as specified and as directed. |
| 100 | Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), including all fittings, heads , shoes bends, swan-necks etc .including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed. |
| 101 | 110mm bore PVC SWR Type-B pipes(pressure not less than 6 kg /cm2) single socket in any length with rubber joints fixed tro wall etc all as specified and directed. |
| 102 | 110mm diaPVC (SWR) Type-B pipes single socketed in any length with rubber ring joint laid in trenches or in floor all as specified and directed |
| 103 | 75mm bore PVC SWR Type-B pipes(pressure not less than 6 kg /cm2) single socket in any length with rubber joints laid in floors/trenches etc all as specified and directed. |
| 104 | 75 mm diaPVC (SWR) Type-B pipes single socketed in any length with rubber ring joint laid in trenches or in floor all as specified and directed |
| 105 | PVC SWR bends any radius 110 mm bore incl access door, completeall as specified. |
| 106 | PVC (SWR) bends any radius 75mm dia complete all as specified and directed. |
| 107 | PVC (SWR) branch piece, single (single T) equal or unequal ordinary or inverted of 75 mm bore pipe provided with oval access door, complete all as specified and directed. |
| 108 | PVC (SWR) 110mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door all as specified and as directed. |
| 109 | PVC (SWR) 75mmjunction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch all as specified and as directed. |
| 110 | PVC cowls 75mm as in repairs complete all as specified and directed. |
| 111 | PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement in repairs complete all as specified. |
| 112 | Stack clamps out of 50mm x 5mm flat iron and 16mm dia round stays, including bolts and nuts and securing ends of stays to wall or roof of 100mm bore of pipe complete all as specified and as directed. |
| 113 | Stack clamps out of 50mm x 5mm flat iron and 16mm dia round stays, including bolts and nuts and securing ends of stays to wall or roof of 75mm bore of pipe complete all as specified and as directed. |
| 114 | Broken stone boulder hardcore of guage nexc 63mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface, complete all as directed. |
| 115 | 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, finished fair & even complete all as specified and directed. |
| 116 | Sand cushioning in flooring below interlocking tiles laid in layers 25mm thick complete all as specified and directed. |
| 117 | Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006)60mm thick,M-35 grade , in paths and hardstanding,with grey cement and coloured pigment, laid tightly overand joints filled with dry sand. (Colour and pattern as approved by GE) complete all as specified and directed. |
| 118 | Precast factory made chequered designer tiles (Rectified interlocking tiles)300x300 mm glazed top (Laqquere finished)made in white cement and pigment base of thickness not less than19 mm indifferent colour and pattern (compressive strength not less than 250 Kg/SqCm) setand jointed in neat cement slurry(colour and pattern as per sample kept in GE office as approved by GE)including 15 mm thick screed bed in CM 1:4 all as specified and directed. |
| 119 | Removing surplus soilto distance not exceeding50 m and depositing where directed at a level notexceeding 1.5 m above the starting pointcomplete all asspecifiedand directed . |
| 120 | Demolition and breaking up drain pipe 150mm dia (salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar/concrete complete all as specified. |
| 121 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 122 | Excavation in trenches not exceeding1.5 m wideand not exceeding 1.5 m deep for laying cable or foundation including gettingout in any type of soil complete all as specified and directed. |
| 123 | Plain Concrete bed to drain pipes in PCC 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed. |
| 124 | RCC classNP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed. |
| 125 | Precast cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) including necessary form work complete all as specified and directed. |
| 126 | Mild steel TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 127 | Returning filling including spreadingwateringand well ramming in layers not exc25cmcomplete all as specifed & directed. |
| 128 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cementt concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, internal dia of pipe in 150mm, complete all as specified and directed. |
| 129 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed. |
| 130 | Point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor theOne light point/fan /bell pointcontrolled by one switch.(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) |
| 131 | One light point controlled by one switch |
| 132 | One 3 pin 5 amps socket point controlled by one 5 amps switch on independent board |
| 133 | One 3 pin 5 amps socket point controlled by one 5 amps switch on same board |
| 134 | All as per item No 130 above but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- (a) One 6 Pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board. |
| 135 | Modular type switch 06 Amps, single pole,1way,1 module,240V, ISI Markedcomplete all as specified and directed. |
| 136 | Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and directed. |
| 137 | Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. |
| 138 | Modular type socket 16 Amps, 2/3 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI MarkedComplete all as specified and directed . |
| 139 | Angle lamp holder, insulated body with back plate for LED lamp including removing old unsv itemcomplete all asspecified and directed. |
| 140 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 141 | LED light fitting 1x20W, 4 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose as approved by GE fixed in repairs complete all as specified and directed. |
| 142 | LED light fitting 1x10W, 2 feet, 220V, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver LED fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose as approved by GE fixed in repairs complete all as specified and directed. |
| 143 | LED INVERTER batten 20 watt 4 feet with square profile and poly carbonate channel lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hoursand connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed. |
| 144 | LED bulb 12 watts, 240Volts,50Hzpin type andincluding removing old unserviceable itemcomplete all as specified and directed. |
| 145 | LED secruity light fitting of capacity25 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. |
| 146 | Supply & fixing in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board 8 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 100Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed. |
| 147 | MCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked fixed in repairs complete all as specified and directed. |
| 148 | MCB single pole & neutral 40 to 63 amps 240 volts 10 KA \"C\" series fixed in repair, complete all as specified. |
| 149 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 150 | Exhaust fansingle phase metal body, AC 230 Volt, 50 Hz, 900 RPMof size 300mm sweep with louvers shutter complete with all accessories including connecting up from ceiling rose complete all as specified and directed. |
| 151 | Sub main wiring complete with 2 runs of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLS type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLStype as earth continuity conductor connected to common earth dollyincluding making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 152 | Ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing and deposit with MES store yard all as specified and directed. |
| 153 | Vertical double door TPNin replacementare fitted with Bus bar neutral link, blanking plates of 4 way(4+12) with suitable for incomming MCCB 4 pole\"G\" frame,having isolated neutral bar, mechanical impact strength IK09, door earthing suitable for MCCB upto 125 Amp, complete all as specified. |
| 154 | MCCB 04 pole 415 volts 16 KA, 63 Amp adjustable thermal & fixed magnetic setting type suitable for TPN vertical loadline DB mentioned at ser No 15 here in before fixed in replacement, complete all as specified. |
| 155 | Supply and fixing in replacementelectric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. |
| 156 | S&F Exhaust fansingle phase PVC/Sturdy engineering plastic body 230V 50 Hz of size 250mm sweep ISI marked with louvers shutter complete with all accessories including connecting up from ceiling rose complete all as specified and directed. Note: Old unsv exhaust fan shall be deposited in MES yard.Make:- Cat part No refresh air SPS of Havellsor its Equivalent cat part of make as specified in list of make here- in after. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail