| 1 | Dismantling of /Demolition of floor hearth or wall tiling including cement mortar bedding (but not backing coat) and removing rubbish off the premises all as directed. |
| 2 | Demolition of cement concrete as in ground floors and in paving n. exc 15cm thickabove ground floors complete all as specified and directed. |
| 3 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. complete all as specified and as directed. |
| 4 | M&L precast cement concrete block masonry with solid block, type C-1,1:3:6 mix ( using 20mm graded aggregate), exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 5 | M&L rendering 20 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:4, complete all as specified. |
| 6 | M&L 25 mm thick cement concrete as in Sub-base in cement concrete type B0 1:2:4 using 12.5mm graded stone aggregate as in floor, finished fair and even or any where as required, complete all as specified and as directed. |
| 7 | S&F Non - skid coloured ceramic tiles of size7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, skirtings etc set and jointed in neat cement slurry and pointed in white or coloured cemert to match including screed bed or bedding layers of mortar 15mm thick for laying floor finishes in CM 1:4 complete all as specified and as directed. |
| 8 | M&L non-skid ceremic tiles coloured 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles including for screed bed (or) bedding layer of morter 15 mm thick for laying floor finishes CM (1:4) complete all as specified and directed. |
| 9 | M&L for 75mm thick plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed. |
| 11 | S&F Steel work in tubular trusses inculding special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 graded St 240 complete all as specified & directed. |
| 12 | Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 13 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl nanital or similar pattern roof covering. |
| 14 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 15 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/ridges/cladding to wall, fixed with self tapping screws/Aluminium screws complete all as specified and directed. |
| 16 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc.1.50sqm & not exc 4.00 sqm each and removing from site complete all as specified and directed. |
| 17 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n exc.1.50sqm with shutter and removing from site complete all as specified and directed. |
| 18 | S&F 35mm thickFlush shutters, solid core construction, with particle board core and plywood face panels, commercial type with both faces are covered with decorative face veneer with lipping/frame to match, all as specified & directed by Engr-in-Charge. |
| 19 | M&L mild steel workin framed work to Door Chowkats (angle in any section as desired),grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doorsand similar work conforming to Fe 290 Gde E-165 |
| 20 | S&F second class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 21 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates, shutters etc including joining cleat for fixing etc. complete all as specified |
| 22 | S&F Anodised aluminium window andventilator shutters, fixed type without sash bar, aluminium sectionweighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, side locks etc. complete all as specified |
| 23 | S&F of 4.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as directed. |
| 24 | S&F 300 mm size MS door spring including roller and roller plate by means of welding or screwing down complete all as directed. |
| 25 | S&F aluminium handles, cast type, anodised of size 150 mm all as specified & directed. |
| 26 | S&F Aluminium anodised, barrel tower bolts of extruded section 150mm long complete all as specified and directed . |
| 27 | S&F aluminium alloy, anodised, sliding door bolt 150mm long with hasp, stapple (bolt type) and fixing clips of sheet, cast or extruded sections complete all as specified and directed . |
| 28 | S&F 125 mm size, mild steel butt hinges, medium weight cold rolled complete all as specified and as directed. |
| 29 | M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new or previously untreatedwooden surfaces exc 10cm girth or girth incl preparation of new wooden surfaces complete all as specified and directed. |
| 30 | M &L for preparing old previously treated steel surface of any description not other wise described over 10 cm in width or girth and applying one coat of synthetic enamel paint in existing pattern complete all as specified and directed. |
| 31 | M&L painting two coats of synthetic enamel paints over a coat of red oxide primer on newsteel surfaces exc 10cm girth includingpreparation of surfaces complete all as specified and directed. |
| 32 | M & L for complete removal of existing panits on wall panel/ plastered surface and prepartion of new or previously untreated wall panel/plastered surafce any description over 10 cm grith or width not otherwise described and painting with two coat of synthetic enamel paint over a coat of alkali resistant primer by complete all as specifed and directed |
| 33 | S&F in repair Stainless Steel Curtain Rail/ Rod having 24mm Outer dia and 1.0mm Wall thickness including Brackets, Side Holders and Rings, etc. and Fixed-in-repairs, complete all as specified and as directed.NOTE :- (a)Stainless Steel Decorative Finials and Stainless Steel Brackets will be provided for Each Length of Curtain Rail/ Rod and Cost of the same will deemed to be included in the Quoted Unit Rate.(b)Only Length of Curtain Rail/ Rod will be Measured for Payment. |
| 34 | S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as dpecified and as directed. |
| 35 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) orinsulation boards/slabs/ blankets, any thickness, including cover fillets |
| 36 | M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screws and S & F ofAnodised aluminium snap grid frame work of size 605 x 605 mm in Ceiling, all as per specification and drawing of MES Schedule for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 37 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick set, jointed with white & grey cement in equal proportion and no pigment set, jointedand pointed in neat cement slurry in floors laid over & including 15mm thickscreed or bedding layer in cement mortar 1:4, over 50mm thick cement concerte type B-2(1:2:4)(40mm graded aggregate) in sub base complete all as specified and as directed. |
| 38 | S& F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 39 | Taking down cement plastering of any description on brick / stone/ concrete wall / ceiling surfaces of any description incl racking out joints hacking for key, scrubbing down with water etc. |
| 40 | M & L rendering 20 mm thick plastering on brick wall or concrete surfaces in cement mortar 1:4 by finished fair and even complete all as specified. |
| 41 | M&L for preparation ofnew plastered surfaces of wall and appling two coats cement base paint over one coat of whitewash all as specified. |
| 42 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings suchasswitches,ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 43 | Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 44 | M & L for Point wiring for one light point controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socket, shaddle etc including 1.5mm thick MS sunken/PVC terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 45 | All as per item 44.00 above but for ceiling fan point wiring |
| 46 | All as per item 44.00 above but for 5A point on (Same Board) with other switches |
| 47 | All as per item 44.00 above but for 5A point on Independent Board |
| 48 | All as per item 44.00 above but with 2.5 sq mm size PVC insulated and unsheathed 1100 volts grade single core stranded( multistrand ) copper conductor cable for 3/6 pin socket outlet 15 amp on one independent board. |
| 49 | S&F Switch Piano 6 Amp, Single Pole, Flush type, 1-way, 230 Volt AC and Connecting up, complete all as specified and as directed. |
| 50 | S&F Socket outlet 6 Amp, 5 Pin, Multi-plug, Flush type, 230 Volt AC, complete all as specified and as directed. |
| 51 | S&F Switch Socket Combination 6 Amp, 5 Pin, Multi-plug, Flush type, 230 Volt AC, complete all as specified and as directed. |
| 52 | S&F Switch Socket Combination 6/16 Amp, 2 in 1 3 Pin, Multi-plug, Flush type, 230 Volt AC, complete all as specified and as directed. |
| 53 | S&F Ceiling Rose 65x50mm, 3 Terminals, Surface Bakelite suitable for 230 Volt AC and Connecting up, complete all as specified and as directed. |
| 54 | S&F Ceiling Fan Regulator 230 Volt AC, Electronic, Rotary Steppedtype, 230 Volt and connecting up, complete all as specified and as directed. |
| 55 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 56 | S&F LED Luminaire 600x600 mm, 35/36 Watt, 220 Volt AC Recessed type with High efficiency PMMA Diffuser Soft Glare Free Light complete with Driver, Holders, LED Lamp suitable for Roof Ceiling, Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/ out Unserviceable Light Fitting, complete all as specified and as directed. |
| 57 | S & F LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specifiedand directed. |
| 58 | S & F Angle Holder, PVC/Polycarbonate type with back plate including LED Bulb, 15 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. |
| 59 | Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc and including one coat of spray painting with approved paint after preparation of surfaces and writting MES No. etc and testing complete all as specified and directed. Note : (i) The cleaning, servicing, oiling, rubber real, greasing and lubricating of ceiling fans has to be carried at site itself and expdr cost deemed to be included in the quoated rates.(ii) Cost of hanging hook/extended MS Pipe/Rod required to be fixed properly deemed to be included in the quoated rates. |
| 60 | S&F Sheet Metal Enclosure for DB\"s when MCBs to be used 8-way, SPN, 240 Volt, Single Doors, IP-43 Protected, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up, including Taking down Unserviceable Sheet Metal Enclosure of any description, complete all as specified and as directed. |
| 61 | S&F MCB 32Amp to 63Amp, Single Pole & Neutral, \"C\" Curve, 50 Hz, 10 kA, 240 Volt and Connecting upincluing Taking down/out Old Unserviceable MCB of any description, complete all as specified and as directed. |
| 62 | S&F MCB 6Amp to 32Amp, Single Pole, \"C\" Curve, 50 Hz, 10 kA, 240 Volt and Connecting up incluing Taking down/out Old Unserviceable MCB of any description, complete all as specified and as directed. |
| 63 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connectedto GalvanisedEarth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion,including Taking down/out Old Unserviceable Earthing (03 Nos Only)of any description complete all as per specified and as directed. |
| 64 | S&F PVC rectangular block for mounting, switches, sockets, fan regulators etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm x 50 mm deepall as specified & directed. |
| 65 | S&F PVC rectangular block for mounting, switches, sockets, fan regulators etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm x 50 mm deepall as specified & directed. |
| 66 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core 16sqmm cable flat or circular |
| 67 | S&F House service bracket (hook type completewith 3.0m long G.I. pipe 40mm dia Med.grade, two nos90 degree bends. M.S. hook and stay or guy |