| 1 | Complete removal of existing water proofing treatment from top of roof and canopies/ chajjas of buildings including removing the debris outside of MD land and earthing strip, electric cable complete all as specified and directed.Note :-Earthing strip and cable to be refixed at the same place after execution of APP. |
| 2 | Material and labour for PCC 1:2:4, Type B0 (using 12.50mm graded stone aggregate) in roof kerbs and padding or mud stops, rounded or chamfered on edge complete all as specified and as directed. |
| 3 | Material and labour 10mm thickrendering in CM 1:3 on roof slab/canopies/ chajjas with water proofing compound @ 3 % of weight of cement and making plastered surfaces to receive water proofing treatment (finished fair and even) complete all as specified and as directed.Note:- Water proofing compound will be measured and paid for seperately as supply only. |
| 4 | Supply only integral water proofing compound complete all as specified and as directed. |
| 5 | Material and labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed. |
| 6 | Material and labour for preparing, clean and dry plastered roof surfaces and applying APP modified water proofing membrane mineral finish with non woven polyster reinforcement/mat not less than 3mm thick having weight not less than 3kg/Sqm including and surface painting, with a layer of blown grade bitumen confirming to IS :3384applied@ .250 kg per sqm, all as per manufacturers instructions complete all as specified and as directed. |
| 7 | Dismantling of cement concrete any description and in any position complete all as specified and directed. |
| 8 | Dismantling of stone slabsin floor apron etc laid bedded and pointed in cement mortar and removing to out side MD land complete all as specified and directed. |
| 9 | Material and labour for 25mm thickPCC 1:2:4, type B0(using12.5 mm graded stone aggregate ) as in sub floors as in level course complete all as specified and directed. |
| 10 | Material and labour for machine cut Kota stone slab flooring 20-25mm thick and over and including 15mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and mirror polishing and cut as per local trade practice and cut to shape of required size complete all as specified and directed. |
| 11 | Material and labour for kota stone slab 20-25mm thick in riser of steps skirting, dado and pillar laid over cement screed and jointed including 10mm thick rendering in CM(1:4) complete all as specified and directed. |
| 12 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing dismantled tiles to outside MD land and rubbish off the premises complete all as specified and directed. |
| 13 | Material and labour forglazed ceramic coloured tiles, 350X250X7mm/ 450X350X7mm thick in size, set on vertical surfaces such as skirting, dado, etc,over and including 10mm thick rendering in cement mortar 1:3set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles, complete all as specified and as directed. |
| 14 | Taking down chowkhat ofany description not exceeding 1.5 sqm each complete all as specified and as directed. |
| 15 | Taking down chowkhat ofany description exceeding 1.5 sqm and not exceeding 4 sqm each complete all as specified and as directed. |
| 16 | Forming jambs, etc, to openings (to foregoing item), including cutting, tooting and properly bonding into work, also facing, jointing and pointing to match existing work in CM 1:4, complete all as specified and directed. |
| 17 | Supply and fix powder coated aluminium frame of standard section for doors,and partitions withdoublerebates including joining cleat for fixing etc. complete all as specified and directed. |
| 18 | Material and labour for powder coatedaluminium door shutters, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws,hinge type B-21 100mm long (3 No.) suitable handle (2 No.)complete all as specified. Note :- Glass / Wiremesh shall be measured and paid seperately. |
| 19 | Material and labour for sheet glass 4.8 mm thick ordinalry quality and glazing with aluminium beeds in squareexceeding 0.50 sqm in each pane complete all as specified and directed. |
| 20 | Supply and fix steel rolling shutters of thickness 1.25mm , with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete push pull or manual type including gear operated type with bevel gear box and crank handle complete all as specified and directed. |
| 21 | Supply and fix for Safety lever locks mild steel with 4 levers for rolling shutter complete all as specified & as directed by engr-in-charge |
| 22 | Supply and fix for ball bearing for rolling shutter complete all as specified and directed. |
| 23 | Material and labour for two coats of sythentic enamel paint on new steelpainted sufaces including prearation of surfaces10 cm width or girth including one coat of red oxide zinc primer complete all as specified & as directed. |
| 24 | Supply and fix powder coated aluminium, three track sliding window frame of section size 92.00x 31.75x1.3mm comprising of one No of fly proof shutter and two nos of glazed shutter frames of section size 40x18x1.3mm thick with necessary joining cleats, glazing clips, rubber gasket, anodised aluminium snap beading and connected locking arrangement complete all as specified and directed. Notes:- (i) Glass filling in panels of windowa and aluminium wire mesh/wire cloth shall be demed to be included in the quoted rate for the item. (ii) Aluminium alloy wire cloth in panels ofwite gauzed shutter shall be0.45mm nominal dia of witer and avg width of aperture 1.40mm, fixed with aluminium wire staples. (iii) Glass filling in panels of glazed shutter shall be 4mm thick tinted sheet glass. |
| 25 | Supply and fix in repair, aluminum anodised grill of 7 mm dia rod square, rectangular, circular or similar type of shape aperture not exceeding 7.00cm in length or width fixed with H or F channel 38 mm x 12 mm x 1.30 mm complete all as specified and as directed.Make :-Sec No 8778, Grill No 20 of Decoare or equivalent |
| 26 | Dismantling of brick work or PCC blocks/stone masonarybuilt in cement mortar complete all as specified and directed. |
| 27 | Material and labour for pre-cast cement concrete 1:3:6,type C-1 (using 20mm graded crushed stone aggregate) as in block masonery exceeding 10cm in width with solid block masonery with solid blocks, setting in CM 1:6 complete all as specified and directed. |
| 28 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water,with and including removing to outside MD landetc.complete all as specified and directed. |
| 29 | Material and labour for 5mm thickrendering in CM 1:3 on ceiling surface finished fair and smooth without using extra cement complete all as specified and directed. |
| 30 | Material and labour10mm thick rendering in CM 1:6 on fair faces of brick or concrete surfaces complete all as specified and directed. |
| 31 | Material and labour for 15mm thickrendering in two layer, 1st layer of 10mm thick in CM 1:4 and second layer of 5mm thick in CM 1:4with WPC @ 3% of by weight of cement on fair faces of brick/concretesurfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 32 | Material and labourfor preparation of newly plastered and unplastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed. |
| 33 | Material and labourfor preparation newly plastered and unplastered surfaces of wall and applying two coats of white washing complete all as specified and directed. |
| 34 | Material and labourfor preperation of new plastered surface of wall and applying two coats of 100% premium acrylic emulsion paint ( Weather Proof)camoufaulage pattern having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 35 | Material and labourfor repairing the edge/corner of chajja /roof/projection down ward type and similar work by using cement concrete 1:2:4, type B0 (using 12.50 mm graded stone aggregate) including necessary formwark & 5mm thick cement plaster in CM 1:4 to match with existing surface complete all as specified and directed. |
| 36 | Supply and fix 0.9 mm galvanized steel wire chicken mesh, of size 25 x 25 mm with staple as in plastering complete all as specified and directed. |
| 37 | Material and labourfor 75mm thick PCC 1:2:4, type B-2 (using 20mm graded stone aggregate) as in sub base of floor and path, plinth protection etc.complete all as specified and directed. |
| 38 | Material and labourfor 100mm thick PCC 1:2:4 type B-2 (using 20mm graded stone aggregate) as infloor and path, etc. complete all as specified and directed. |
| 39 | Material and labour for forming contraction (Dummy) joints 75 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade \"A\" in plinth protection complete all as specified and directed. |
| 40 | Material and labour for forming constructionjoints 30 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade \"A\" in plinth protection complete all as specified and directed. |
| 41 | Taking down copper/aluminum point wiring (light, fan, socket or power) complete and including (fitting and fixture such as switches, socket ,ceiling rose ,pendent ,regulators,light fittings, etc to be measured separetaly) Note:- Job including for taking out old gutties,screw,nails,casing caping/conduit etcand making good to disturbed surface of wall ,floor etc including to match with the existing surface. |
| 42 | Material and labourfor point wiring with 1.5 sqmm FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor drawn through PVCconduit with all accessories concealed in thewall /roofsetc and incl provision of 1.5 sq mm PVC insulated and unsheathed copperconductor as earth continuity conductor and connected to common earth dolly complete all as specified and directed for following:- |
| 43 | One light/fan point controlled by one switch. |
| 44 | One socket 3 pin outlet 5 amp on independent board. |
| 45 | One 3 pin socket outlet 5 amp on the same board with other switches. |
| 46 | All as per serial item number 42.00 here-in-before but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sqmm 2.5 sqmm copper cable as earth continuity conductor complete all as specified and directed. |
| 47 | Supply & fix moduler switch 1 way 6A 1 module complete all as specified and directed. |
| 48 | Supply & fixmoduler switch 1 way 16A 1 module complete all as specified and directed. |
| 49 | Supply & fix ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified and directed. |
| 50 | Supply & fix moduler socket 6A/16A, 2/3 pin combined,2 module complete all as specified and directed. |
| 51 | Supply & fix moduler socket 6A 2/3 pin combined,2 module complete all as specified and directed. |
| 52 | Supply & fixmoduler fan regulator 120 W. 2 module complete all as specified and directed. |
| 53 | Supply & fixmoduler white cover plate with frame. 3 module complete all as specified and directed. |
| 54 | Supply & fixmoduler white cover plate with frame. 6 module complete all as specified and directed. |
| 55 | Supply & fix moduler metal flush box 3 module complete all as specified and directed. |
| 56 | Supply & fixmoduler metal flush box 6 module complete all as specified and directed. |
| 57 | Supply & fixLED light fitting 1x20watt , 220V, AC decorative box type with driver, holder,including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed. |
| 58 | Supply and fixsub main wiring drawing through PVC conduit concealed in wall/roof with four single core 4 sq mm and two run of 4 sqmm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradecomplete all as specified and directed. |
| 59 | Supply and fixsub main wiring drawing through PVC conduit concealed in wall/roof with two single core 4 sqmm and one run of 4 sqmm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade complete all as specified and directed. |
| 60 | Supply and fixMCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wallcomplete all as specified and directed. |
| 61 | Supply and fixMCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wallcomplete all as specified and directed. |
| 62 | Supply & fix415V 10KA \"C\" curve Miniature circuit breaker(MCB) ofTriple pole and neutral 63 ampsComplete with connection testing and commissioning complete all as specified and directed. |
| 63 | Supply & fix240V 10KA \"C\" curve Miniature circuit breaker(MCB) ofSingle pole and neutral 32 ampsComplete with connection testing and commissioning complete all as specified and directed. |
| 64 | Supply & fix240V 10KA \"C\" curve Miniature circuit breaker(MCB) ofSingle pole 5 to 32 ampsComplete with connection testing and commissioning complete all as specified and directed. |
| 65 | Supply and hanging /fixing in repair ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of \"B\" class insulation, single phase, minium 26W (± 10%), Temperature rise 40 degree maximum without remote with and including operative based capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and directed. |
| 66 | Supply & fixin repair/replacement of LED flame proof well glass in die cast aluminum housing with heat resistant toughened glass, 70watt , IP65 protected and including all accessories, connecting up with flexible copper conductor 1.5 Sqmm 3core covered with flexible metal conduit of suitable size complete all as specified and directed. |
| 67 | Supply and fix flameproof weatherproof distribution board aluminum die cast alloy in LM6 material sheet metal enclosure incl MCB 32Amp SPN(Incomer) and 04 Nos SP 6-32 Amp(Outgoing) terminal, wiring and incl all fitting accessories etc complete all as specified and as directed. |
| 68 | Supply and fix flame proof/ weather proof exhaust fan,single phase,230 volt 450mm sweep, 0.25HP motor suitable for wall mounting with louvers complete all as specified and directed. |
| 69 | Supply and fixin repair switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed |
| 70 | Material and labour for sub main wiring with 3 run single core multistranded copper conductor cable, of size 1.5Sqmm, PVC insulated, unsheathed, FRLSH drawn through and including heavy duty ERW steel conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete including taking down old sub main wiring complete all as specified and directed.Note:- 02 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment. |
| 71 | Supply & fixaesthetically designed LED security light luminiareis of 35 watts system wattage for energy saving having IP 66 degree of protection,with minimum system efficiency as>85%,made ofpressure die casting aluminum housing power coated in graphite grey andheat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light Fitting should have operating voltage range of 120-270 VAC,THD<10%,P.F>.95 The fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including 40mm dia GI pipe light grade of 1.5mtr length with necessary clamp & nut bolts complete all as specified and directed. |
| 72 | Material and labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 73 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M indepth for laying of LT UG cable pipe line, etc in soft / loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 74 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed. |
| 75 | Removing excavated material (Soil) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point all complete all as specified and as directed. |
| 76 | Material and labour for clean dry river sandin trenches/ ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified. Note:- Punned thickness shall be measured and paid separately. |
| 77 | Supplying and laying unreinforced precast cement concrete cable covers, Class LV, Type- 1, Flat, size 250 mm x 150 mm x 40 mm in trenches for cable protection, embossed with \"LT 1100 VOLTSELECTRIC\" on the top surface complete all as specified and as directed. |
| 78 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm, 3.5 Core complete all as specified and directed. |
| 79 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm, 2 Core complete all as specified and directed. |
| 80 | Supply and fix 4 pole MCCB63 Amp, 50Hz , 415 V with rupturing capacity 25KA complete all as specified and directed. |