| 1 | Dismantling manually/ by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge : bituminous road |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as wellas 10 sqm on plan) including getting out and disposal of excavated earthlead upto 50 m and for all lift, as directed by Engineer-in-charge. All kindsof soil |
| 3 | Demolishing cement concrete manually/ by mechanical means includingdisposal of material within 50 metres lead as per direction of Engineer - in -charge. Nominal concrete 1:3:6 or richer mix (including equivalent designmix) |
| 4 | Demolishing cement concrete manually/ by mechanical means includingdisposal of material within 50 metres lead as per direction of Engineer - in -charge. Nominal concrete 1:4:8 or leaner mix (including equivalent designmix) |
| 5 | Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m aboveground level and removal of rubbish up to a distance of 50 m outside theperiphery of the area cleared. |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement :4 coarse sand) |
| 7 | Supplying and filling with Coarse sand (zone IIl) including watering,ramming, consolidating and dressing complete. |
| 8 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20 mmthick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shadepigment using white cement |
| 10 | Providing and laying tactile tile (for vision impaired persons as perstandards) of size 300x300x9.8 mm having with water absorption less than0.5% and conforming to IS:15622 of approved make in all colours andshades in for outdoor floors such as footpath, court yard, multi modalslocation etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4coarse sand) in all shapes & patterns including grouting the joints withwhite cement mixed with matching pigments etc. complete as per directionof Engineer-in-Charge. |
| 11 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarsesand (zone-IIl) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources) |
| 12 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. In gratings, frames, guard bar,ladder, railings, brackets, gates and similar works |
| 13 | Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer all complete. |
| 14 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing withcement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In75x75 mm deep chase |
| 15 | Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-Charge) of totalcoated thickness 0.50 mm (base metal of minimum 0.45 mm thickness withtotal coating thickness of 0.05mm) with zinc coating 120 grams per sqm asper IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sideof the sheet and polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratches duringtransportation and should be supplied in single length upto 12 metre or asdesired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete uptoany pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shapewherever required. |
| 16 | Providing and fixing precoated galvanised steel sheet roofing accessories oftotal coated thickness 0.50 mm (base metal of minimum 0.45 mm thicknesswith total coating thickness of 0.05 mm) with Zinc coating 120 gram persqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns using selfdrilling/ self tapping screws complete : Flashings/ Aprons.( Upto 600 mm) |
| 17 | Providing and fixing precoated galvanised steel sheet roofing accessories oftotal coated thickness 0.50 mm (base metal of minimum 0.45 mm thicknesswith total coating thickness of 0.05 mm) with Zinc coating 120 gram persqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer onboth side of the sheet and polyester top coat 15-18 microns using selfdrilling/ self tapping screws complete :Crimp curve |
| 18 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted withspecial shaped washers etc. complete. Hot finished seamless type tubes |
| 19 | Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade: Two or more coats on new workover an under coat of suitableshade with ordinary paint of approved brand and manufacture |
| 20 | Removing dry or oil bound distemper, water proofing cement paint and thelike by scrapping, sand papering and preparing the surface smoothincluding necessary repairs to scratches etc. complete. |
| 21 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqmand under, including cutting the patch in proper shape, raking out jointsand preparing plastering the wall surface with white cement basedpolymer modified self curing mortar, including disposal of rubbish, allcomplete as per the direction of Engineer-In-Charge. |
| 22 | Providing and applying white cement based putty of average thickness1mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 23 | Applying priming coats with primer of approved brand and manufacture,having low VOC (Volatile Organic Compound ) content. With waterthinnable cement primer on wall surface having VOC content less than 50grams/litre. |
| 24 | Finishing walls with Acrylic Smooth exterior paint of required shade : Oldwork (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cementpaint surface. |
| 25 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete |
| 26 | Distempering with 1st quality acrylic distemper (ready mixed) having VOCcontent less than 50 gram/litre, of approved manufacturer and of requiredshade and colour all complete to achieve even shade and colour: New work(two or more coats) over and including water thinnable priming coat withcement primer having VOC content less than 50 gram/litre. |
| 27 | Steel reinforcement for R.C.C. work includingstraightening, cutting. bending, placing in position and binding all completeupto plinth level.Themo Mechanically Treated bars of grade Fe-500D ormore |
| 28 | Diluting and injecting chemical emulsion for POST CONSTRUCTIONAL antitermitetreatment (excluding the cost of chemical emulsion) :Along theexternal wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including drilling and plugging holes etc.: WithChlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 29 | Providing and laying four courses water proofing treatment with bitumenfelt over roofs consisting of first and third courses of blown bitumen 85/25or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre ofarea for each course, second course of roofing felt type 3 grade-I (hessianbased self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea sized gravel spread at 6 cubic decimeter persquare metre, including preparation of surface but excluding gradingcomplete with : Bitumen felt (hessian base) type 3 grade I conforming toIS : 1322 |
| 30 | Providing and laying PVC sheet of 125 micron. |
| 31 | Providing and fixing partition upto ceiling height consisting of G.I. frameand required board, including providing and fixing of frame work made ofspecial section power pressed/ roll form G.I. sheet with zinc coating of 120gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floorand ceiling at the spacing of 610 mm centre to centre with dash fastener of12.5 mm dia meter 50 mm length or suitable anchor fastener or metalscrews with nylon plugs and the studs 48 mm wide having one flange of 34mm and other flange 36 mm and 0.50 mm thick fixed vertically withinflanges of floor and ceiling channel and placed at a spacing of 610 mmcentre to centre by 6 mm dia bolts and nuts, including fixing of studs alongboth ends of partition fixed flush to wall with suitable anchor fastener ormetal screws with nylon plugs at spacing of 450 mm centre to centre, andfixing of boards to both side of frame work by 25 mm long dry wall screwson studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixingchannel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each)to be provided at the horizontal joints of two boards, fixed to the studsusing metal to metal flat head screws, including jointing and finishing to aflush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats ofprimer suitable for board as permanufacture’s specification and directionof engineer in charge all complete.66 mm overall thickness Partition with 8 mm thick double skin CalciumSilicate Board made with Calcareous & Siliceous materials reinforced withcellulose fiber manufactured through autoclaving process withCompressive Strength 225 kg/sqcm,Bending Strength 100 kg./ sq.cm |
| 32 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillartaps, 32 mm C.P. brass waste of standard pattern, including painting offittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mmC.P. brass pillar taps |
| 33 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C.waste fittings complete. Flexible pipe 32 mm dia |
| 34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply and all CPVC plain & brassthreaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cementand testing of joints complete as per direction of Engineer inCharge. Internal work - Exposed on wall 15 mm nominal dia Pipes |
| 35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints completeas per direction of Engineer in Charge. External work 20 mm nominal diaPipes |
| 36 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ringconforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Singlesocketed pipes. 110 mm diameter |
| 37 | Providing & fixing false ceiling at all heights with GRG (Glass FibreReinforced Gypsum) false ceiling tiles of Size 595x595 mm of approvedtexture, design and patterns having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85%(minimum) to be laid in true horizontal level suspended on inter-lockingmetal T-Grid of hot dipped galvanised iron section of 0.33 mm thick(galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mmof length 1200 mm and secondary intermediate cross-T of size 15x32 mmof length 600 mm to form grid module of size 600 x 600 mm, suspendedfrom ceiling using galvanised mild steel items (galvanizing @ 80 grams persqm) i.e. 50 mm long, 8 mm outer diameter M-6 dashfasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and Lshapelevel adjuster of size 85x25x2 mm. Galvanised iron perimeter wallangle of size 24x24x0.40 mm of length 3000 mm to be fixed onperiphery wall / partition with the help of plastic rawl plugs at 450 mmcenter to center and 40 mm long dry wall wood screws. The work shall becarried out as per specifications, drawing and as per directions of theEngineer-in-Charge. With fully perforated 12 mm thick micro tegular edgedor 10 mm thick square edged GRG false ceiling tiles. |
| 38 | Providing laminated veneer lumber conforming to IS:14616 and TAD-15:2001 (Part B) in factory made frames of doors, windows, clerestorywindows and other frames, wrought framed and fixing in position withhold fast lugs or with dash fasteners of required dia & length (hold fast lugsor dash fastener shall be paid for separately). |
| 39 | Providing and fixing 35 mm thick factory made laminated veneer lumberdoor shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixingwith butt hinges of required size with necessary screws, all complete as perdirections of Engineer- in-charge and panelling with panels of :(Note:- Butthinges and necessary screws shall be paid separately) 12 mm thick prelaminatedparticle board (decorativelamination on both sides) grade -1, medium density flatpressed, three layer particle board FPT- | or graded woodparticle board FPT- I, conforming to IS : 3087, bonded withBWP type synthetic resin adhesive as per IS : 848 andpre-laminated conforming to IS : 12823, Grade 1, Type - Ilmarked. |
| 40 | Providing and fixing bright finished 100 mm mortice lock with 6 leverswithout pair of handles of approved quality for aluminium door, withnecessary screws etc complete as per direction of Engineer- in-charge. |
| 41 | Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): With floatglass panes of 8 mm thickness (weight not less than 20 kg/sqm.) |
| 42 | Centering and shuttering including strutting, propping etc. and removal ofform for Foundations, footings, bases of columns, etc. for mass concrete |
| 43 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) |
| 44 | Providing and fixing factory made precast RCC perforated draincovers,having concrete of strength not less than M-25, of size 1000 x450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos crosssectional T.M.T. hoop bars, including providing 50 mm dia perforations @100 to 125 mm c/c, including providing edge binding with M.S. flats of size50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. |
| 45 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size) |
| 46 | Providing and laying in situ seven course water proofing treatment withAPP (Atactic poly-propylene) modified Polymeric memberane over roofconsisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th &6th courses of bonding material @ 1.20 Kg/sqm, which shall consist ofblown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5thlayers of roofing membrane APP modified Polymeric membrane 1.5 mmthick of 2.25 Kg/sqm weight consisting of five layers prefabricated withcentre core as 20 micron HMHDPE film sandwiched on both sides withpolymeric mix and the polymeric mix is protected on both side with 20micron HMHDPE film. 7th, the top most layer shall be finished with bricktiles of class designation 10 grouted with cement mortar 1:3 (1cement :3fine sand) mixed with 2% integral water proofing compound by weight ofcement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand)and finished neat (item of laying brick tiles shall be paid for separately). |
| 47 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length and jointedtogether at the end by end locks, mounted on specially designed pipe shaftwith brackets, side guides and arrangements for inside and outside lockingwith push and pull operation complete, including the cost of providing andfixing necessary 27.5 cm long wire springs manufactured from high tensilesteel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25mm M.S. laths with 1.25 mm thick top cover |