| 1 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed. |
| 2 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 3 | Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 4 | Taking down ceiling fan/ exhaust fan/Geysers of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard of AGE E/M complete for refixing.complete all as specified and directed. |
| 5 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts gradeISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches,including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable with casing caping as surface to match with existing finish complete all as specified and directed for the following :- |
| 6 | (a) One light point controlled by one, one way switch 5 Amps |
| 7 | (b) One fan point/ wall mountedfan point controlled by one, one way switch 5 Amps and regulator |
| 8 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 9 | (d)One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 10 | Description all as per item No 5 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. complete all as specified and directed. |
| 11 | Description all as per item No. 5 here in before butusing 4.0 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of4.0 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) |
| 12 | S & F modular switch piano flushtype, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 13 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 14 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 15 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 16 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified |
| 17 | S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 18 | S & Ffor metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Ampsincluding removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed |
| 19 | S & Fmodular white cover plate with frame 3 module |
| 20 | S & Fmodular white cover plate with frame 6/8 module |
| 21 | S & Fmodular metal flush box for 3 module |
| 22 | S & Fmodular metal flush box for 6/8 module |
| 23 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 24 | S & F for sheet metal enclosure MCBDBTPN4 way Vertical type with 200 Amps suitable for MCCB 125 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 25 | Supply and fix 4 Pole MCCB 100 to 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and as directed. |
| 26 | S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 27 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 28 | S & Ffor MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 29 | Re-fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories complete all as specified and as directed. |
| 30 | Re-fixing of wall mounted fanof 250 mm sweep made of plastic/steel bodycomplete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core fromforconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed. |
| 31 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, poly coabonate, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. . |
| 32 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired andnecessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. |
| 33 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connected to earthing point complete all as specified and as directed. |
| 34 | Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPEinsulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of sizecomplete all as specified and directed and including taking down existing cable any type.(a) 3.5 core x 70 Sqmm |
| 35 | Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as per & directed. |
| 36 | Returning filling including spreading levelling watering & well Ramming in layers not Exc 25 cm complete all as spfd & directed. |
| 37 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. |
| 38 | M&L for bricks common burnt sub class B designation for protection of cable complete all as specified and directed. |
| 39 | M&L for natural local river sand for cable protection. |
| 40 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete. |
| 41 | M & L for anodised aluminium snap grid frame work for false ceiling all as specified and as directed. |
| 42 | S&F 4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling. |
| 43 | Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 44 | M&L for rendering 10mmthick in ceiling on brick work or concrete surfaces in CM (1:3), finished even and smooth without using extra cement all as specified and directed. |
| 45 | M&L for rendering 10mm thick internal wall surfaces on fair faces of brick work or concrete in CM (1:6) as directed by Engr-in-charge. |
| 46 | M & L for preparation of new plastered/decorated wall surfaces and applying two coats of distempering with oil bound distemperas per manufacturer instruction white or tinted complete all as specified and directed. |
| 47 | M&L for two coats of oil bound distemper on newly plastered surfaces of celling including prepration of surfaces complete all as specified and directed. |
| 48 | M & L for applying a thin layer of 0.50mm thick white wall care putty over newly plastered surface toprepare the surface even and smooth complete all as specified and directed. |
| 49 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement) complete. |
| 50 | M & L for preparation of new plastered/decoarated wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 51 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing from the site. |
| 52 | M & L for providing 75mm thick PCC (1:3:6) type C-1, (using 20 mm graded aggregate) as sub base flooring complete and finishing surfaces even and smooth without using extra cement complete. |
| 53 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 54 | M&L for vitrified Ceramic tiles light shed 8 mm thick (square/ rectangular) polished, area of each tiles notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM (1:6) complete. |
| 55 | All as per ser item No 15 above but as in vertical surfacesin skirting and dado including rendering/screeding including cement mortar (1:4) , 10 mm thick complete. |
| 56 | S & F sandwiched hollow PVC wall Lining/panelling consisting of 5mm thick Plain designer colour PVC sheet but single side prelam PVC sheet used instead of plain colour sheetinclusive of solvent cement and fixing at site on wall/PVC frame etc complete all as per specified and directed. |
| 57 | M & L for preparation of old decorated surfaces including brooming down or steel wire brushing complete of walls and applying one coat of distempering with oil bound distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 58 | M & L for applying a thin layer of 0.50mm thick Birla white putty/JK white wall care putty on wall surfaces including removal of existing treatment and making the surface uniform and smooth complete all as specified and directed. |
| 59 | M & L for Preparation of old decorated surfaces of ceiling and applying one coat of distempering with oil bound distemper as per manufacturer instructions white or tinted complete all as specified and directed. |
| 60 | M&L for one coat of exterior weather coat paintwhite or tinted on walls or fascia of roof or chajjas on old decorated prepared plastered/painted surfaces of bldg all as specified & directed. |
| 61 | M & L for Cement concrete type B-0, (1:2:4) (12.5 mm graded aggregate), 25 mm thick in flooring etc complete all specified and as directed |
| 62 | M&L for preparation and filling of pitting/cracks (including V groove cutting of cracks/deepening) on surfaces with crack seal and finishing the surfaces as per existing treatment complete all as specified and directed. |
| 63 | Taking down chowkhats or frames not exc 1.5 Sqm (without taking shutters from the frame). |
| 64 | Taking down chowkhats or frames exc 1.5 Sqm but exc 4.0 Sqm (without taking shutters from the frame). |
| 65 | S&Faluminum frame powder coated for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed. |
| 66 | S&F anodised aluminium door shutter with powder coating (minimum thickness of powder coating 50 micron) aluminium sections weighing not less than 1.0 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door,anodised aluminium hinges, snap beading, screws,etc complete all as specified |
| 67 | S&Fany colour, aluminum window and ventilator shutters, powder coated sliding/side hung type with sash bars, aluminium section weighing not less than 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, ruber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 68 | S&F10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed. |
| 69 | S & F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified. |
| 70 | S&F in replacement aluminium (die cast body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width andweight between 61 to 80 Kg complete all as specified as directed. |
| 71 | S & F 100 mm long mortice latch with two levers(vertical type), mild steel body complete all as specified and directed. |
| 72 | S&F galvanised stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples or screw complete all as specified and directed. |
| 73 | Hacking out old broken glass (any the size quality or description) from wooden and steel frames glazed complete all as specified and directed. |
| 74 | S & F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or rubber beading in squares of any size complete all as specified and directed. |
| 75 | S&F Sheet glass 5.5 mm thickness, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 76 | M&L 6 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice laminationfixed with screws/beading to timber/aluminium frame work or as required on site including fixing arrangement complete all as specified and directed. |
| 77 | S & F in repair 20mm bore cut to length as required stainless steel decorative draphery rods with brackets and decorative finails as requiredcolour complete all as specified and directed. |
| 78 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples or screw complete all as specified and directed. |
| 79 | Taking down existingaluminium partition and re-fixing in same place after repair/replace the defective jointing cleats/screws all as specified and directed. |
| 80 | Taking down existingdoor shutter with frame area exceeding 1 Sqm & n exc 2.5 sqm and re-fixing in same opening after repair/replace the defective jointing cleats/screws complete all as specified and directed. |
| 81 | M & L for providing water proofing treatment over cleaned roof surface with super thermo APP modified polymeric membrane comprising of followings :- (i). Complete removal of existing roof treatment by picking, sweeping clean and washing down with water to remove dust etc from plastered / roof surface / walls and filling the crackes with sealing compound grade \"A\" .(ii) Rendering / screed bed 15 mm thick in cement mortor (1:4) mixed with liquid water proofing compound as per manufacturer\"s instructions andfinished the surface fair and even. (iii) Applying evenly a coat of bitumen based primer conforming to IS-3384-1965 @ 0.30 Kg/Sqm.(iv) Applying 3 mm thick APP modified polymeric membrane with non polyster reinforcement of approved make, weight not less than 3.50 Kg/Sqm laid with gas torch and fastedon roof surface with roller. The over laps 100mm and shall be sealed by torch application as per manufacture instructions including vertical surfaces after cutting necessary grooving and making good with PCC 1:2:4 type B-O with sika latex power as per manufacture instructions.(v) Applying two coats of bituminous anticorrosive multi purposealuminium coating (super silver shield) @ 150 gm/sqm per coat over polymeric membrene. Note :- WPC shall be measured and paid separately. |
| 82 | Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. |