| 1 | Dismantling of asbestos cement corrugated sheets as in roof coverings complete all as specified and directed. |
| 2 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (AZ-150) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete as specified and directed. |
| 3 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick (AZ-150)of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete as specified and directed. |
| 4 | Dismantling Framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 5 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 6 | Demolition of Concrete in ground floors and pavings including floor tiles n exc 15 cm thickness (below or above ground level) complete all as specified and directed . |
| 7 | M&L For Cement concrete 1:4:8 type D-2, ( using 40 mm graded stone aggregate)as in foundations, filling and mass concrete etc. Complete as directed. |
| 8 | M&L Brick work using sub class old bricks straightor curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 9 | M&L 15mm thick cement plastering on concrete surfacesin CM (1:4) finishing surfaces even and smooth without using extra cementcomplete all as specified and as directed. |
| 10 | M&L preparing newly plastered surfaces of wall and applying complete wall with1.0 mm Wallputty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed . |
| 11 | M&L Preparation of newly plastered or unplastered surfaces on wall surfaces and applying two coats of cement base paint completeall as specified. |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 13 | S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etcFe 410 W (Gde E - 250 quality) complete all as specified and directed . |
| 14 | All as per item no 13 but febrication only complete all as specified and directed. |
| 15 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of Old steel surfaces complete all as specified and directed. |
| 16 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed. |
| 17 | S& F forPlates (plain or chequered) Fe 410-W (GdeE- 250) quality A channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed. |
| 18 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair complete all as specified and directed |
| 19 | M & L Machine cut Kota stone slab flooring 18-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick Cement Mortar 1:6 incl dismantling of existing kota stone Incl Screed bed complete all as specified and directed by Engr-in-Charge. |
| 20 | M & L Machine cut Kota stone slab flooring 18-22mm thickin riser of steps, skirting, dado and pillar laid over over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 15 mm thick Cement Mortar 1:6 incl dismantling of existing kota stone Incl Screed bed complete all as specified and directed. |
| 21 | S & F Powder coated aluminium two/three track frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws,etc complete all as specified.Note : (i)Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item.(ii) Item shall be paid as per weight of aluminium section (iii)The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight.(iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. |
| 22 | S&F 5mm thick tinted glass in aluminium doors & windows with rubber packingincluding hacking out old broken glass complete all as specified and directed by . (any thickness, size from aluminium beading ) complete all as specified and directed. |
| 23 | S&F in Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding/Staples directed . |
| 24 | S & F 5 MM thick ACP Sheet fixed to aluminium frame work complete as specified and as directed |
| 25 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete all as specified and directed . |
| 26 | S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed . |
| 27 | S&F 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed. |
| 28 | Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches, ceiling roses, pendent, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed. |
| 29 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 30 | M & L for point wiring using approved colour coding as per IS with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 31 | (a) One light point controlled by one way switch 5 Amps |
| 32 | (b) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 33 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 34 | S & F switch piano flushtype, single pole, one way and 5/6 Amp single complete. |
| 35 | S & F socket outlet multipurpose with provision of 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete. |
| 36 | S & F ceiling rose, surface bakelite with 3 terminals, ISImarked for batten fitting complete all as specified. |
| 37 | S & Fmodular white cover plate with frame 3 module |
| 38 | S & Fmodular white cover plate with frame 6/8/12 module |
| 39 | S & Fmodular metal flush box for 3 module |
| 40 | S & Fmodular metal flush box for 6/8/12 module |
| 41 | S & F for sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 42 | S&F in replacement of MCCB 4 pole, 100 to 125 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed.Make :Havells/ L&T /Legrand |
| 43 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 44 | S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 45 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 46 | M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 47 | S&F in replacement of LED panel light fitting 36 watt LED (2x2 ft), LED panel fitting, including LED in white230 volt energy saving environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP-65 luminaire with PC housing in opal finish suitable for wet location with brighness LEDs with all accessories internally prewired and including connected with twin core twisted flexible wire copper conductor cable with suitable size complete all as specified and directed. |
| 48 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note: GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 49 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm x 3.5 Core passing through DWC HDPE / in trench including necessary connection with lugs and cable gland etc complete all as specified and directed. |
| 50 | Excavation in trenches n.exc 1.5 mtr wide and 1.5 mtr in depth in hard/dense soil for taking up/ laying of cable and getting out complete all as specified and directed. |
| 51 | Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 52 | Removing surplus soil to a distance n.exc 50 mtr and making good the disturbed surfaces complete all as specified and directed. |
| 53 | Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. |
| 54 | Supply and laying for brick of common burnt clay, sub class \"B\" old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. |
| 55 | Galvanised iron steel tubes, ISI marked light grade of size 40mm bore for cable protection along the poles under road under drains complete all as specified. |
| 56 | Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. |