| Sl. No. | Item Description |
| 1 | Dismantling/ demolition ofpolymeric water proofing membranesingle layer with and including plaster, PCC, Padding, brick coba etc on roofs complete including removal of materialand debris away from the site etc complete all as specified and directed. |
| 2 | M&L for Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jet to remove dirt and loose particles. Brush apply a bond coat ofPidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface complete all as specified and directed. |
| 3 | M&L for Laid to fall roof screed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10% by weight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water. Level the repair mortar and finish with trowel. Moist cure should be done for 7days. Air cure screed for 7days, before application of roof top coat coating system etc complete all as specified & directed. |
| 4 | Apply one coat ofCipoxy 16D primer in the ratio 1:1 spreading at the rate of 0.200 kg-0.250 kg /sqm in complete dry condition where moisture contain below 7% (should be checked with moisture meter)Allow the primer coat to dry for 6 to 8 hours. Apply 1st coat ofRoofseal Classic without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4 to 6 hours. Apply the second of chemical with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 4-6 hours after application. Check to see no void surface is left untreated / uncoated.Allow the system to air cure for 7 days minimum etc complete all as specified & directed. |
| 5 | Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 6 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed. |
| 7 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed |
| 8 | M&L for Providing and Repairing the damaged concrete portion / Surface preparation with single component ready to use, repair mortar SMARTCAE REPAIR MORTAR capable of applying 15-20 mm avg. thick in single layer initially by hand and finishing with trowel, carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surfacecomplete all as specified and directed |
| 9 | M&L for 10-12mm thick smart care ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions )over interior surface of wall complete all as specified and directed. |
| 10 | Preparingnewly plastered surfaces of walls and applying two coats of oil bound distemper over 3mm thick wall care putty on wall complete all as specified and directed. |
| 11 | M&L for complete removal of extg treatmentof oldplastered surfaces of wall and applying two coat of oil bound distemper with roller on old decorated wall surfaces over 3 mm thick white putty complete all as specified and directed. |
| 12 | Material & Labour forpreparingnewly plastered surfaces of wall, applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including putty over new surface of wall complete all as specified and directed. |
| 13 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm including puttycomplete removal of existing treatment old wall surface complete all as specified and directed. |
| 14 | M&L for applying three coats of white wash on wall including preparation of new plastered or un-plastered surfaces of walls, complete all as specified and directed. |
| 15 | M & L for Preparingold plastered surface to prepare the surface even and smooth and two coat of white wash on ceiling complete all as specified and directed. |
| 16 | M&L for appliyng 3mm thick wall care putty on wall /ceiling complete all as specified and directed |
| 17 | Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Paymentfor providing grooves shall be made separately). |
| 18 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 19 | M&L for applying polymer modified primer on steel reinforcements which is a blend of portland cements, graded filters, corrosion inhibiting additive and re-dispersible polymers in powder form that when fixed with water forms slurry for application by brush to cover exposed reinforcement. The product shal achieve an adhesion bound strength of 1 Mpa to steel. It has got a pot life of 30 minutes @ 300 C. the touch dry time shall be 10-15 minutes @ 300 C. The mixed density shall be 2.01 - 2.05. The water / powder ratio by weight shall be 0.3. It shall achieve coverage of 2 kg / sqm @ 1.0 mm thickness, applying on visible reinforcement surface to from a continuous film not less than 1 mm thick complete all as specified and directed |
| 20 | M& L for Providing and fixing on ceiling /wall /column by duly welding MS wire mesh weighting not less than 1kg/sqm before fixing ,surface should be cleaned and should not be free from dirt ,oil grease etc complete all as specified and directed. |
| 21 | M&L for external plastering of brick / concrete surface of wallusing fiber reinforced polymer modified repair mortar. The product shall be a single component thixotropic fiber reinforced polymer modified repair mortar needing only addtion of water at site which can be applied by trowel. It is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking. It is recommended for repair situations requiring application of mortar upto 18-20 mm thickness in one layer. Cement and sand can be used for finishing the surface. complete all as specified and directed. |
| 22 | M&L for applying two component amine cured epoxy mastic coating as bonding agent between old and new surface of wall and ceiling surface using light brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern. It should be based on a 100% epoxy formulation and contains no solvents or water diluents. Apply two coats with brush or squeeze to the existing surface, working well into the substrate complete all as specified and directed. |
| 23 | M&L One coat of epoxy resin (FAIR BOND EP) on old concrete surface @ 0.30 kg/Sqm including preparation of surface as per as per manufacturer\"s instruction and applying 25 mm thick on ceiling, beams, chajjas & facia surface etc (average thickness) of cement and sand (fine grit) in ratio 1:4 mixed with chloride free sprey concrete plasticiser (spray crete) as per manufacturer\"s instruction with guniting machine of pressure capacity not less than 5kg per Sqm and finished the surface even & smooth in CM 1:4 plaster min. 10 mm thick complete all as specified &as directed . |
| 24 | Dismantling asbestos cement (corrugated semi corrugated etc ) sheets in roof covering above 12 to 15 m height complete all as specified and directed. |
| 25 | S&F for pre- painted galvatume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of and colour having tensilestrength of 550 Mpa as in roof covering/cladding towall, fixed with selftapping screws up to a height of 12 to15m complete all as specified and directed |
| 26 | S& F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 27 | Dismantling timber scantlings 40 sq. cm and over in section, in any position |
| 28 | S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming toFe-290 Gde-E-165 including for drilling the members for site, fitting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats connections complete all as specified and directed. |
| 29 | S&F joist, channel, angle or tee sections fixed independently without connecting platges, etc (cut to ordinary length) including welding to other steel members of Fe 410 Gde complete all as specified and directed. |
| 30 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-290 grade E-165 including for drilling the members for site, Fabrication, fitting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting connections complete all as specified and directed. |
| 31 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete , including taking out, cleaning of flase ceiling and handling removing to store or stacking for reuse all as specified and directed. |
| 32 | S&F anodised aluminium/GI snap grid frame work for false ceiling all as specified of grid 605 x 605 including GIhangersof suitable dia and fixed to purlin/rafters as specified. |
| 33 | S&F 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 34 | Solid PVC Wall Lining consisting of5mm thick Plain colour PVC sheetinclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 35 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 36 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed. |
| 37 | M&L 25 mm thickPCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base of flooringfinished even and fair without using extra cement complete all as specified & directed. |
| 38 | M&L for coloured glazed ceramic tiles (Digital & designer Pattern)in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10mm thick rendering in CM 1:3 on brick wall complete all as specified and as directed . |
| 39 | M & L for Vitrified tiles 10mm thick light shade (square/rectangular) area of each tileexceeding 0.42 sqm but n exc 1.00sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchin floor over and including 15mm thick cement screed bed of CM (1:6) complete all as specified & directed. MAKE: Johnson/Kajaria/Somany . |
| 40 | M&L colour vertified ceramic tiles 10 mmthick (square/rectangular) area of each tile exceeding not exc. 0.36Sqmas in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in CM (1:4)complete all as specified and directed.(toilet,bath,kitchen, passage floor) |
| 41 | M&L non skid joint free coloured tiles(1st quality/premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.11Sqm but not exc. 0.18 Sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6)complete all as specified and directed. |
| 42 | M&L Granite 20 mm thick in steps, pillars, window cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rounding edges of stone slab one edge and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and as directed. |
| 43 | Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings, kerbs, benching and the like, including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete. |
| 44 | Taking up or down 15mm bore steel tubing and connection complete all as specified and directed. |
| 45 | Taking up or down 20 mm bore steel tubing and connection complete all as specified and directed |
| 46 | Supply and fixing 20 mm bore galvanised tubesmedium grade , with all fitting and fixed complete to walls and ceilings,roofs or laid in floors complete all as specified. |
| 47 | Supplying and laying 20 mm outer diameter of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 48 | Cutting chases for pining in for GI pipe ,codute complete all as specified and directed. |
| 49 | Dismantling Water tanks, open or closed, hoisted and fixed in position complete all as specified and directed. |
| 50 | S&F 500 Ltr Rotational moulded polyethylenewater storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed. |
| 51 | S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight- 210 gm) complete all as specified and directed. |
| 52 | S & F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as spd and dir. |
| 53 | S&F in repair PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed |
| 54 | S&F in repairs Vitreous China wash hand basin white flat back size 550x400mm including cutting for and pinning in ends of brackets or erecting stand , 32 mm dia Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 45gms/40mm-60 gm) and32 mm PVC flexible waste pipe 800mm long etc complete all as specified and directed. |
| 55 | S&F in repair 15mm bore, brass chromium plated pillar cock (foam flow & Long bend ) screwed down for pipe and fixed complete all as specified and directed. |
| 56 | S&F in repairs 800x600 mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 57 | S&FTowel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimumweight 90gms). |
| 58 | S&F CP soap dish brass chromium plated, size 100 x 60mm, fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed. |
| 59 | S&FSheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 60 | S&F in repair full stall typeVitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) cistern, trap and waste pipe) complete all as specified and directed. |
| 61 | S& F in repairsingle piece EWCwith UF seat cover hinges,fixing accessories set,cistern fittings,rim Less tornado flushing size 360 680x750 mm complete all as specified and directed. |
| 62 | S & F in repairsHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.ompleted all as specified and directed. |
| 63 | S & F in repairs 20 mm bore chromium plated fancy bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 64 | Supply and fixed in repair angular valve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed. |
| 65 | S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall and floor complete all as specified and directed. |
| 66 | S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall and floor complete all as specified and directed. |
| 67 | S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed. |
| 68 | S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed. |
| 69 | S & F 110 mm bore PVC (SWR) bends with access door of any radius complete all as specified & directed. |
| 70 | Taking down Chowkhats or frames not exc. 1.5 sq. mbut (without taking off shutters from the frames each complete all as specified and directed. |
| 71 | Taking down Chowkhats orframes exc. 1.5 sq. m but n. exe 4 sqm (without taking off shutters from the frames each complete all as specified and directed. |
| 72 | S&F powder coated aluminium partition of specified aluminium section top rail and middle rail 2.36 Kg/RM, bottom channel 2.59 Kg/RM including aluminium beads rubber gasket and 5mm thick frosted glass in upper portion and 12 mm thick prelaminated particle board, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination complete all as specified and directed. |
| 73 | S&F powder coatedanodized aluminium door & framewith reqd size of aluminium sections weighing not less then 0.55 kg/m or as per site requirement including 5 mm thick tinted glass coloured in half portion andin other half portion 4 mm thick ACP sheet of any colour complete and fixed with anodized aluminium snap beading, glazing clips, joining clips, screws and 02 Nos of aluminium handle on each door shutter, aluminium anodized tower bolt 200mm long 02 Nos on each shutter andlock device complete with double keys for each lock, 01 No Hydraulic door closer for each shutter complete all as specified and directed with following specifications:- (a) Aluminium door frame = 101.50x44.45mm(b)Aluminium style/top & middle rails of shutter = 83.5x44.45mm(c) Aluminium bottom rail of shutter = 114.50x44.45mm(d) Aluminium door frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed. |
| 74 | S & F powder coatedAnodised aluminium three track sliding window made of extruded profiles with reqd size of aluminium sections weighing not less then0.55 kg/m or as per site requirementincluding necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and plain glass on two shutters and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixedwith stainless steel wire staples on one shutters with two nylon roller on each shutters including star lock handle complete all as specified and directed by Engineer-in-charge |
| 75 | S&F aluminium anodised grill (DG 104) 10mm x 5 mm thick on Deco grill or equivalent fixed with \"F\" section approved make complete all as specified and directed. |
| 76 | S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron) weighing 0.55 Kg/M or frame size as per ground requirement complete all as specified |
| 77 | Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m or as per site requirement includingnecessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specifiedcompleteallasspecified and directed. |
| 78 | S&F 4 mm thick sheet glass plain/frosted ordinary quality and fixed with aluminum beading and gaskit suitable for aluminum frames in squares not exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 79 | S&F in repairs Stainless steel drapery rods, 20mm internal diameter including decorative type brackets and PVC curtain rings 8 Nos per RM including fixing arrangement with drilling holes in walls, brackets etc complete all as specified and directed. |
| 80 | PCC 1:3:6 C-2 (using 40mm graded crushed stone aggregate) as in plinth protection, path ( 75 mm thick ) finished cement concrete surface even and smooth without nusing extra cement all as specified. |
| 81 | M&L for Preparation of New or previously untreated steelsurfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide. |
| 82 | S & FFramed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 |
| 83 | S&F Door closer (aluminium ectruded section)hydraulically regulated, designationNo. 3,universal type, suitable for door shutters of 851 to 1000 mm in widthand of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 84 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 85 | M&L Cement concrete 100 mm thicktypetypetypeD-2, 1:4:8(40mm graded aggregate) Stone Aggregate as in sub base of floor etc complete all as specified and directed. |
| 86 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer throughvibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sandcomplete all as specified and directed. |
| 87 | Taking down carefully copper/aluminium point wiring on batten/ PVCconduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed. |
| 88 | M&L for concealed point wiring for one light point/fan point/bell point controlled by one switch (using red, black and green colour coding) complete with 1.5 sqmm unsheathed and multi stranded copper conductor single core FRLSH PVC insulated, 1100 volts PVC insulated unsheathed cable with proper colour codingdrawn in through and including PVC concealed conduit not less than 25 mm dia ( medium duty, ISI marked) with all fittings and accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc.,including pressed steel powder coated sunken terminal box suitable for modular switch socket including provn of 1.5 sqmm single core FRLSH PVC insulated multi standed copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ ceiling/ floors etc by using CM (1:3) complete all as specified and as directed.NOTE:- Modular switches/ socket/ regulator shall be measured and paid separately under appropriate item. |
| 89 | All as per item No-2 here in before but for One socket outlet 5/6 Amps on independent switch board controlledby one switch completeit with 2.5sqmm unsheathed and multistranded copper conductor single core, complete all as specified & directed. |
| 90 | All as per item No-2 here in before but for One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete it with 2.5 sqmm unsheathed and multistranded copper conductor single core, complete all as specified & directed. |
| 91 | All as per item No-2 here in before but using2.5 sqmm PVC FRLSH insulated stranded copper conductor cable andfor one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed.NOTE-For item no 2 to 5 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light fittings shall be measured and paid for separately under appropriate item of schedule A.(iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 25 mm dia (medium grade).(iv) The rate of all type of conduit, fittings, rawl plugs etc deemed included in items. |
| 92 | All as per item No-5 above but using 4.0 sqmm PVC FRLSH insulated stranded copper conductor cable and for one socket outlet 3/5/6 pin, 15/16A controlled by one way switch on an independent board complete all as specified and directed. |
| 93 | Supply and fix modular switch single pole, one way 5/6 Amps 1 module, complete all as specified and directed. |
| 94 | Supply and fixing modular switch 15/16 Amps single pole one way, one module, complete all as specified and directed. |
| 95 | Supply and fix modular socket outlet 3 pin 5/6 Amps, complete all as specified and directed. |
| 96 | Supply and fix modular socketmultipurpose 3/5 pin 15/16 Amps combined 2 module, complete all as specified and directed. |
| 97 | Supply and fix modular step type, 2 module electronic fan regulator heavy duty 120watts 240 volts,complete all as specified and directed. |
| 98 | Supply and fixing modular cover plate with metal frame (inner and outer) 2 module for mounting switch and sockets all as specified and as directed. |
| 99 | Supply and fixing modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets all as specified and as directed. |
| 100 | Supply and fixing modular cover plate with metal frame (inner and outer) 4 module for mounting switch and sockets all as specified and as directed. |
| 101 | Supply and fixing modular cover plate with metal frame (inner and outer) 6 module for mounting switch and sockets all as specified and as directed. |
| 102 | S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed. |
| 103 | Supply & fix commissioning and testing of complete power cum starter unit compressing of ON/OFF switches socket 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 20 Amps load bearing capacity complete all as specified and directed. |
| 104 | Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed. |
| 105 | Supply and fixing LED Bulb 15 watt, colour temp-6500K, lum output-945lm, Base cap- B22 single phase, 230 Volts AC supply suitable for lamp holdercomplete all as specified and directed. |
| 106 | Supply and fixing LED luminaire fully diffused, 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light, extruded aluminium housing 11.5mm depth only,edge lit LED panel with light output of 3000 lumen, 25000 hrs life class, 4000k Neutral white light, complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete as specified and directed. |
| 107 | Supply and fixing 20W Inverter LED batten of size 4 ft with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 108 | Supply and fix LED sensor batten 20W size 4 ft, 2000lm power saving LED lighting, smart motion and ambient light sensor, less energy consumption – Lesser Electricity bill & Higher savings Convenience - Bright & Efficient light source with 100lmn/. Complete all as specified and directed. |
| 109 | S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresnel diffuser with silicon gaskets for IP-65 protection, power consumption of 35 W and system efficiency > 100lm /W, in built electronic driver pre-wired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, CRI > 70, ambient temperature range 0-450c, THD<10%, colour temperature 5700K, surge protection cm 3.5KV 50000burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low voltage safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 25 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall all as specified and directed. |
| 110 | Supply & fix focus light have 38 degree narrow beam angle light distribution, Aluminium die cast housing, with 12 W LED, 1200 lumen, round in shape,colour temp (3000k, 6000K), length-158mm, Width-103mm, Dia-73mm, Height-128mm including connecting up with three flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 111 | Taking down care fullysub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor . |
| 112 | M&L forsub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:-Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 113 | M&L forsub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:-Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 114 | Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces. |
| 115 | Supply and fix in replacement MCB DB vertical type 4 way VTPN sheet metal enclosure415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable tiesfor cable management suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mounting type double door factory fabricated completewithout MCB & MCCB but with enclosure blank plate complete all as specified and directed . |
| 116 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 12 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. |
| 117 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. |
| 118 | S&F MCCB of rating 100 Amp, 4 pole, 415 V, AC fixed type with breaking capacity 16 KA DPX³ 160 type, as per ICE- 60947-1 Ics 100% of Icu, Adjustable tripping: 0 - 0.3 - 1 - 3s with adjustable 70% to 100% and thermal magnetic release to be fixed in existing LT panel for taking In coming electric connection for VTPN DB complete all as specified and directed at site. |
| 119 | Supply and fixing in replacement MCB SPN240V,50 Hz, 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity SPN 40 to 63 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed. |
| 120 | Supply and fixing in replacement MCB SPN240V,50 Hz, 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity SPN 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed. |
| 121 | Supply & fix in replacement MCB SP, 40 Amps, \"C\" Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. |
| 122 | Supply & fixMCB SP, 6 to 32 Amps, \"C\" curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI markedcomplete all as specified & directed. |
| 123 | Supply and fix electric water heater, of capacity 25 Ltrs vertical storage type, outer body of the heater is made with tough ABS material with special inner tank coating that prevents corrosion and rusting and results in a long tank life energy-efficient and HeatingElement upto 2 KW (copper tube)-Spiral Type Multiple safety systems for protection against dry heating, overheating and overpressure, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece (hot & cold of length upto 450 mm long withto be fixed on wall withfastener mild steel 100 mm long x 10 mm dia with expansion type split pin and bolts complete for hanging of geyser all as specified and directed. |
| 124 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and directed. |
| 125 | Supply and fix ceiling fan, 1400mm sweep, minimum 245 CFM, 230 V, BEE 5 star rated, BLDC(brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts,bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm stranded copper conductor 3 core flexible cable cord complete all as specified and directed. |
| 126 | M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanized steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mmformed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Loose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 . |
| 127 | Supply and fix drawn 2 pair conductor of size 0.5 Sqmm armoured telephone cable, copper PVC insulated and over all screened with tinned copper net and PVC insulated complete all as specified & directed (For Telephone). |
| 128 | Supply and fix dish TV cable cordof size 1.5 Sqmm solid copper conductor triple insulated steel wire mess inner sheathing earth continuity conductor, coaxial cables and over all PVC sheathed circular complete all as specified & directed. |
| 129 | Supply & Fix Cable telephone outlet socket switch type flush mountedRJ-11 including modular cover plate and metal flush boxcomplete all as specified & directed. |
| 130 | Supply & Fix Cable TV outlet socket switch type flush mountedincluding modular cover plate and metal flush boxsuitable for TV cable cord connection complete all as specified & directed. |
| 131 | M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any height or in any position from existing bldg and deposit it to E/M yardincluding replacement of three core flexible copper conductor cable from ceiling rose to fan connector block of size 0.75 Sqmmand hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed at site by Engr-in-Charge. |
| 132 | Supply and fix 2 Core X 1.00/1.50 sq.mm. Copper Conductor,PVC Insulated, Twisted pair, Unshielded with Polyester Tape + Nylon Thread & PVC Outer sheath of grey colour. 2 Core X 1.00 Sq.mm. Copper Conductor,PVC Insulated, Twisted pair, Unshielded with Polyester Tape + Nylon Thread & PVC Outer sheath of grey colour for PA addressing system complete all specified and directed |
| 133 | Disconnecting& taking up or down existing unserviceable UG cable/service wire aluminium conductor including GI wire any size and type, complete all as specified and directed. |
| 134 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core. |
| 135 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soilcomplete all as specified and as directed by Engineer-in-Charge. |
| 136 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. |
| 137 | Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge. |
| 138 | Supplying and laying un-reinforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable. |
| 139 | M&L for sand cushioning dry fine for cable cushioningbelow and abovethe cable complete all as directed at site by Engr- in-Charge. |
| 140 | Supply and fixing GI Pipe 40mmLight grade , for cable protection laid in trench under road or pathor fixed on pole or wall with clamps with all fittings complete all as specified and as directed at site. |
| 141 | Supply and fix \"Medium Grade\" galvanized iron tubes with all fittings such as tees bends elbow etc laid in trenches of25 mm bore complete all as directed |
| 142 | Supply and fix \"Medium Grade\" galvanized iron tubes with all fittings such as tees bends elbow etc fixed on walls/ floors of 20 mm bore complete all as directed |
| 143 | Supply and fix gun metal gate valve of 20mm bore with iron wheel head screwed both ends for iron pipe and fixed of following sizes complete all as directed. |
| 144 | Taking up/down for 25mm bore old GI pipes and connections complete all as specified and directed. |
| 145 | Taking up/down for 20mm bore old GI pipes and connections complete all as specified and directed. |
| 146 | Material and labour for drilling and tapping cast iron water mains (in position) for branch connections of the internal 25mm dia complete all as specified and directed. |
| 147 | Excavation in trenches not exc 1.5m width and n. exc 1.5m in depth and getting out for laying of pipes etc in any type of soil complete all as directed. |
| 148 | Returning filling in incl spreading leveling watering and well ramming in layers n.exc 25cm in any type of soil complete all as directed. |
| 149 | Removing excavated material n.exc 50m and depositing where directed at a level n. exc 1.5m above starting point complete all as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail