| 1 | NOTES :-In case description of any two or more items of the schedule ‘A’ is same and the tenderer quotes different rates for such items, only lowest rate of such items will be considered for acceptance and subsequently payment will be made upon execution of the items accordingly. |
| 2 | Dismantling wallandceilingboards(fibre,pulp, insulation, etc.) orinsulationboards/slabs/ blankets, any thickness, includingcover fillets complete all as directed |
| 3 | S&F GI powder coated snap grid frame work of size 600X600mm having Main Tee of 24X32mm, Cross Tee 24X26mm and L angle of 24X24mm for false ceiling along with Hangers 2 mm dia GI (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. |
| 4 | M&L False ceiling of 8mm thick gypsum ceiling tiles with front PVC laminated & back Aluminium foil, Ceiling board of dimension 595X595mm with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre grid (Frame work of ceiling shall be measured and paid separately).Make:Diamond, Everest or Equivalent. |
| 5 | Demolition of cement concrete (Reinforced) of any description andin anypositionnot otherwise specifically provided for |
| 6 | S & F Solid PVC Wall Lining consisting of5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing atsite on PVC frame as per specifications and drawing |
| 7 | S & F 5mm thick PVC sheet fillet of width35mm for wall paneling inclusive offixing on to wall to make PVC Frame asper specification and drawing. |
| 8 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar,complete all as directed |
| 9 | M&L Brickwork with fly ash bricks, straight or curved on plain exc 6m mean radius, built in cemrent mortar 1:4 complete all as specified and as directed. |
| 10 | Taking down Chowkhats or frames with shutters exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and as directed. |
| 11 | S & F 2nd class HW Plain, solid, straightchowkatsand frames, wrought, framed rebatedon the solid , rounded or chamfered,put together with glue pinnedatjoints,suppliedandfixed complete all as specified and directed |
| 12 | S & F 35mm thick Plain framed, panelledshutter (two panel) with lock rail and panel of 9 mmB.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated complete all as specified and directed |
| 13 | S&F 200 mm size Aluminium tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed |
| 14 | S&F 150 mm size extruded aluminiumdoor handlesfabricated type complete all as specified and as directed |
| 15 | S&F 200mm long Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 16 | S&F mild steel helical door spring rat tail rod model including roller plate complete 300 mm long complete all as specified and as directed |
| 17 | S&F 140 mm longfloor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and as directed |
| 18 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 19 | M & L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed |
| 20 | M&L Rendering 15 mm thick in CM 1:6 onbrick massonry surfaces of walls, finished even and smooth with out using extra cementall as specified and directed. |
| 21 | M&L preparation of newly plastered surfaces of walls including cornices and applying two coats of oil bound distemper over a coat of primer and chalk whitingwith using of all fixtureswhich are necessary for execution of work and leaving premise,clean and tidy all asspecified & directed |
| 22 | M&L for two coats of Oil bound distempering over a coat of primer over 3mm thick wall putty withwhite or tinted on walls complete all as specified and as directed. |
| 23 | M & L for taking down and refixing in other opening for chowkhats orframes withshutters (withouttaking off shuttersfrom the frames) not exc. 1.5sq. m each |
| 24 | M & L for taking down and refixing in other opening for chowkhats orframes withshutters (withouttaking off shuttersfrom the frames)exc. 1.5sq. m but not exc 4 Sqm each |
| 25 | Demolition of unreinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 26 | M&L 75 mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and directed |
| 27 | M&L for Rubberised chequered cement concrete tiles30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floorswith grey cement and pigment laid over 15mm thick cement screed bed 1:6 complete all as specified and directed. |
| 28 | M&L sand filing under floors including watering and consolidation all as specifide and directed |
| 29 | M&L Rubberised Machine pressed precast concrete interlocking paverblock any shape and sizeconfirming to IS 15658-2006 of 80 mm thickness M-40Gradeall as specified and directed |
| 30 | Removing excavated/demolished material exc 250 m n.exc 500m or out of MOD land and depositing where directed at a level n.exc 1.5 km above the starting point. |
| 31 | S&F false ceiling at all heights withsemi perforated 12mm thick micro tegular edged GRG (Glass Fiber Reinforced Gypsum ) fire resistant false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than2%, humidity resistance of 99%, NRC 0.5-0.75 as per IS 8225:1987, Non combustable as per BS 476 (part 4 )-1970 and light reflectance 85% min to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @120 grams per sqm including both sides) comprising of main -T runners ofsize 15 x 32 mm of length 3000mm, cross -T of size 15x32 mm of length1200mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm , suspended from ceiling using galvanised mild steel items ( galvanising @ 80 gms per sqm) i.e. 50mm long, 8 mm outer diameter M6dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the helpof plastic rawl plugs at 450 mm center to center and 40mm long dry wall SS screws all as specified and directed by Engr-in -charge.Make : Diamond,Gyproc or equivalent |
| 32 | Taking down carefully existing unserviceablealuminum/copperpoint wiring (light, fan, socket or power) of any description & in anyposition complete including all fittings& fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etcincluding taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed |
| 33 | Taking down distribution boards / main switches/Earth plug sockets of any type, size and capacity and refixing the same with all necessary electrical connections both wiring and cable complete all as specified and directed by Engr-in-charge |
| 34 | Taking down MCBs, metal clad plug of any type, size and capacity complete all as specified and directed by Engr-in-charge |
| 35 | Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces all as specified and as directed. |
| 36 | Material and labour for Disconnecting of air conditioners along with stabilizers and accessories and refixing the same after the work is complete all as specified and directed by Engr-in-charge. |
| 37 | M&L for point wiring with 1.5 Sqmm (nominal area) multi stranded copper conductor, single core, FR-LSH PVC insulated & unsheathed cable in accordance with IS 694 with proper colour coding, 1100 volts grade drawn in ISI marked MMS non-metallic PVC conduit of size not less than 20mm dia conforming to IS 9537:latest, concealed type terminated in sunken type GI sheet metal flush boxes of 16 Gauge (i.e. 1.6mm thickness) including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FR-LSH PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE FOR ITEM NO. (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes and pvc conduitsto required depth & making good the disturbed surface in CM 1:4 including core cutting wherever required and finishing the surface to match with the existing surface. If the building is stone masonry, diamond tools must be used to cut the surfaces. In case the flush box needs to be installed on surface, prior approval must be taken from the Engineer-in-charge and surface modular boxes made of FR grade ABS of minimum 1mm thickness with rounded corners need to be used instead of metal flush boxes.(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A\".(iii) The quoted rates shall be deemed to be inclusive for provision and installation of conduits, covering sunken boards/terminal boxes / junction boxes of any shape and size modular white colour cover plate with frame and modular metal flush box. All metal boxes and plates to be of the same make as the switches mentioned in this schedule. |
| 38 | One light point controlled by one; one way switch. |
| 39 | One buzzer point controlled by one; one way switch. |
| 40 | One fan/exhaust fan point controlled by one, one way switch |
| 41 | One 3 pin socket outlet 5 amp point on the independent board |
| 42 | All as per item No.36here-in-before butwith 2.5 sq mm size FRLSH PVC insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board. |
| 43 | All as per item No. 36 here-in-before butwith 4 sq mm size FR-LSH PVC insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3pin socket outlet for ACs and geysers |
| 44 | Cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills, sunshades, shelves, lintels, etc.;and cutting chases for concealed water tubing or concealed conduitwiring, etc. and making good, cutting not exceeding 10cm girth complete all as specified and as directed by the Engineer-in-charge |
| 45 | S&F ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specifiedanddirected. |
| 46 | Supply and fix modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge. |
| 47 | Supply and fix modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge. |
| 48 | Supply and fix modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
| 49 | Supply and fix modular socket, 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge |
| 50 | Supply and fix modular fan regulator 100 W 2 module, socket type and capacitive type all as specified and directed by Accepting officer |
| 51 | S&F modular metal flush box 1/2 module complete including taking down the existing and depositing to E/M store and any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. |
| 52 | S&F modular metal flush box 3 module complete including taking down the existing and depositing to E/M store and any civil work required to make good the disturbed surface all as specified and directed by Engr-in-charge. |
| 53 | S&F modular metal flush box 12 module including taking down the existing and depositing to E/M store and any civil work required to make good the disturbed surface complete all as specified and directed by Engr-in-charge. |
| 54 | S&F modular metal flush box 18 module including taking down the existing and depositing to E/M store and any civil work required to make good the disturbed surface complete all as specified and directed by Engr-in-charge. |
| 55 | Supply and fixing of modular cover plate white with frame complete for1/2 module including taking down the existing and depositing to E/M store complete all as specified and directed by Engr-in-charge. |
| 56 | Supply and fixing of modular cover plate white with frame complete for3 module including taking down the existing and depositing to E/M store complete all as specified and directed by Engr-in-charge. |
| 57 | Supply and fixing of modular cover plate white with frame complete for12 module including taking down the existing and depositing to E/M store complete all as specified and directed by Engr-in-charge. |
| 58 | Supply and fixing of modular cover plate white with frame complete for18 module complete all as specified and directed by Engr-in-charge. |
| 59 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roofceiling including connecting up with driver three core flexible copper conductor cases of suitable size and depositing the existing light fittings to MES E/M store and refixing the rest of the lights complete all as specified and directed by Engr-in-charge |
| 60 | S & F 4ft 20W LED batten tubelightsurface/wall mounted with powder coated Aluminium housing, high optically efficient polycarbonate diffuser, inbuilt electronic driver duly wired upto terminal block, luminous efficiency > 100 lm/watt, surge protection upto 4kV, 440V High voltage protection, power factor > 0.95, CRI > 80 all as specifiedanddirected. |
| 61 | S&F MCB single pole, 6 to 32 Ampsin `C’ series having current rating 10 KA complete all as specified and directed. |
| 62 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories without remote, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated as per latest BEE norms in vogue at the time of supply with brushless direct current motor (BLDC) including fan hooks and mounting arrangement to ceiling complete all as specified and directed by Engineer-in-Charge. |
| 63 | S & F call bell, ding dong AC 230 Volt single pole complete as specified. |
| 64 | Supply and laying Non-metallic PVC conduit MMS grade conforming to IS 9537:latest, FRLS, dia 20mm including all accessories and hardware complete all as specified and directed by the Engineer-in-charge.Note: Cost of cutting chases shall be measured and paid separately under relevant item of this schedule. |
| 65 | S&F in replacement 400mm swing wall fan, 4star, smooth oscillation, copper motor with remote control, 72 speeds, plastic body complete all as specified and directed |
| 66 | Supply and fixing angular Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by the Engineer-in-charge |
| 67 | Supply and fixing 0.5-Watt B22D Base LED Bulb, 50lumens, round shape, 3000K, CRI not less than 70, 220-240Volts, 50HZ complete all as specified and directed by the Engineer-in-charge. Note: Colour of the light shall be red and green as specified by the Engineer-in-charge |
| 68 | Supply, installation, fixing, testing and commissioning AC Split type, Intellisense inverter technology compressor, Five star energy saving unit, single phase, cooling capacity 1.5 TR, including Remote Control unit,Plasma filter for better indoor air quality with minimum 5 star rating electric driven and split AC copper condensing unit (outdoor unit) fixed onsuitable size perforated angle iron frame for mounting condensing units as required and evaporator grouted in side room at suitable height with provision of outlet PVC pipe for draining out condensed water up to floor level and gas connection by soldering or brazing including extra copper pipe duly insulated by insulated material & gas where as required and testing after installation complete all as specified and directed by Engineer-in-Charge.Make : Carrier/ Daikin/ Havells/ Voltas |
| 69 | Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directedby Engineer-in-Charge.Make : Sinetrac/Microtech/V Guard Industries Ltd/VINITEC/ Power one Micro System (POWER ONE) / India Techno Indus (Spectron) |
| 70 | Supply and fixingsheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated single pole MCB 10 KA, \"C\" curve complete all as specified and directed by Engineer-in-Charge. |
| 71 | M&L for submain wiring with 2 x 4.0 Sqmm and 1x 4.0 sqmm earth wire FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Conduit/ casing capping maintaning the colour coding as per electric rules and all required accessories of suitable size consealedion wall/roofcomplete all as specified and directed by Engineer-in-Charge.Note:Two runs of 4.0 Sqmm copper cable, one run 4.0 Sqmm copper cable for earth wire and one run of PVC conduit shall be measured as one unit length. |
| 72 | M&L for submain wiring with 2 x 6.0 Sqmm and 1x 6.0 sqmm earth wire FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Conduit/ casing capping maintaning the colour coding as per electric rules and all required accessories of suitable size consealedion wall/roofcomplete all as specified and directed by Engineer-in-Charge.Note:Two runs of 6.0 Sqmm copper cable, one run 6.0 Sqmm copper cable for earth wire and one run of PVC conduit shall be measured as one unit length. |
| 73 | Supply and fixingsheet metal enclosure powder coated forMCB DB SPN08 way double door with IP-42 protectionwith Din rail and busbar complete all as specified and directed by by Engineer-in-Charge. |
| 74 | Supply and fixing MCB SPN, 40 to 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply and fixing MCB single pole, 6 to 32 Ampsin `C’ series having current rating 10 KA complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply and fixing UPS for 30 min back up Singlephase AC input 160 to 260 V and out put 230 ± 1% of capacity 3 KVA complete all as specified and directed by Engineer-in-Charge. |
| 77 | Excavation in trenches,not exceeding 1.5m wide and not exceeding 1.5m in depth in any type of soil for foundations etc or for shafts, well cess pits, manholes, pier holes etc but not exceeding 10 sqm on plan and n exc 1.5 m in dpeth and getting out |
| 78 | Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soil complete all as specified and directed |
| 79 | Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed |