| 1 | Note :The unit rate quoted by the tenderer under Col No (13) of Sch `A’ (BOQ) unless specifically mentioned otherwise such as labour only/fixing only,for all items of works shall be deemed to be including cost of all materials, labour, tools and plants, testing and commissioning of work in position complete as required for entire completion of work. |
| 2 | Dismantling the entire roof covering including brick tiles/ concrete tile of any thickness, mud phuska, mud plaster and water proofing treatment any number of layers or thickness etc. of any description upto RCC roof slab and cleaning the surface including flashings and junction of parapets, etc. with wire brushes and water to the entire satisfaction of Engineer-in-charge including removing the retrieved material to a place earmarked by civic body and applying neat cement slurry @ 3.00 kg/ Sqm , complete all as specified and directed by Engineer-in-Charge. Notes:- (i) The quoted rate shall deemed to be included for necessary temporary arrangement of water supply from existing connection to toilets, bathrooms and kitchen for convenience of the occupants staying in quarters until completion of entire roof treatment and no any extra payment(ii) Dismantled material should be removed manuallyusingstairall as directed by Engineer-in-Charge. |
| 3 | Plain cement concrete , (1:2:4) type B-0,using 12.5 mm graded mechanically crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throatingin andincluding demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removal of rubbish to a place earmarked by civic body ,complete all as specified and directed by Engineer-in-Charge. Note :Use and waste of form work shall deemed to be included in the quoted rate . |
| 4 | Plain cement concrete, 1:2:4) type B-0 , using 12.5 mm graded mechanically crushed stone aggregates as in roof kerb or mud stops in and including mixed with acrylic base liquid water proofing compound s per manufacturer’sinstructions including all necessary formworkin andincluding demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removal of rubbish outside MoD land ,complete all as specified and directed by Engineer-in-Charge.Notes:-(i)Quoted Rate of above item is inclusive the cost ofWPC and nothing extra shall be admissible on this account.(ii) Use and waste of form work shall deemed to beincluded in the quoted rate . |
| 5 | Plain Cement concrete type B-0, 1:2:4 by using 12.5mm graded mechanically crushed stone aggregateas in roof padding to maintain the required slopeor to prepare gola etc icluding weathering slightly ropunded or chamfered angles and throating as directed in and including mixed with acrylic base liquid water proofing compoundper manufacturer’sinstructions including necessary form work in andincluding demolition of (un-reinforced) cement concrete of any description or as roof padding and coveringg concretein any position not otherwise specifically provided forand remove all the debris to a place earmarked by civic body , complete all as specified and directed by Engineer-in-Charge. Notes:-(i)Quoted Rate of above item is inclusive the cost ofWPC and nothing extra shall be admissible on this account.(ii) Use and waste of form work shall deemed to be included in the quoted rate . (iii) Padding concrete shall be laid to maintain the required slope with thickness at lower end and at ridge as directed by Engineer-in Charge.(iv) Contractor shall provide leveling bench mark at ridge level and up to edges with distances as directed by Engineer in Charge |
| 6 | Rendering 10 mm thick in cement mortar (1:3), as on fair faces of concrete surfaces finished the surfcae even and smooth without using extra cementmixed with liquid water proofing compound as per manufacturer’sinstructions,complete all as specified and directed by Engineer-in-Charge. Note:- Quoted Rate of above item is inclusive the cost ofWPC and nothing extra shall be admissible on this account. |
| 7 | Preparation of newly plastered/RCC surfaces, making the surface completely dry and applying a coat of bitumen primer, having density in range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 70 to 160 CPS, manufactured by same manufacturer @ 0.4 ltr/sqm shall be applied and after drying of primer for 24 hours apply APP modified prefabricatedwater proofing membrane with non - woven polyster reinforcement, 3mm thick superior multipolymeric, weighing not less than 3.00 kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyetylene (MHHDPE) film consisting of five layers laid with torching application to the surface comeplete and sealing the side as well as end laps with torch (overlaps should not be less than 10cm in longitudinal direction and 15cm in traverse direction and shall be bonded with bitumen primer and levelled by heating the overlaps with brutane torch) ,complete all as specified and directed by Engineer-in-Charge. |
| 8 | Cement concrete tiles 25cm x 25cm x 22 mm thick machine pressed bedded on 20 mm thick screed bed in cement moratr 1:4,set jointed and pointed in neat cement slurry in floors, and cut and polished with grey cement and no pigment etc ,complete all as specified and directed by Engineer-in-Charge. |
| 9 | Water proofing treatment to sunken portion of WCs,bath room etc by applying cement slurry mixed with acrylic based polymer modified cementious compound coating of make as approved by GE:-(a) Roughening of surfaces of old concrete floor/slab by wire brushing,sweeping,cleaning and washing down to remove all loose dust etc,and brushing neat cement slurry @ 3.00 Kg/Sqm on floor/roof surface.(b) 15 mm thick screed plaster on RCC slab in cement mortar 1:4 in and including using water proofing compound @ 3.00% by weight of cement and finishing the surface even and smooth without using extra cement.(c) First layer of slurry of cement @ 0.488 Kg/Sqm.This followed layer will be allowed to air curing for 4 hrs.(d) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with acrylic based polymer modified cementious composite compound @ 0.126 Kg/Sqm this layer will be allowed to air cure for 4 hrs followed with water curing 48 hrs.Note:-Quoted Rate of above item is inclusive the cost of WPC and nothing extra shall be admissible on this account. |
| 10 | Plain cement concrete (1:2:4) type B-1 using 20 mm graded mechanically crushed stone aggregates using integral water proofing compound @3% by weight of cement as in padding concrete to sunken floor, Coving /gola to junction of the floor and virtical walls including chamfering on edges,necessary form work in andincluding demolition of (un-reinforced) cement concrete of any description or as roof padding and coveringg concretein any position not otherwise specifically provided forand remove all the debris to a place earmarked by civic body ,complete all as specified and directed by Engineer-in-Charge.Note: Quoted Rate of above item is inclusive the cost ofWPC and nothing extra shall be admissible on this account. |
| 11 | Steel water tubing 40 mm bore medium grade ISI marked galvanized as in spout for sunken floor fixed as in wall with inside and fixed with wire netting and external end bevelled edge at 45 degree, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Plain cement concrete(1:5:10), type E-2, using 40 mm graded mechanically crushed stone aggregates and finished the surface rough as filling and mass concrete (Sunken portion)in andincluding demolition of (un-reinforced) cement concrete of any description or as roof padding and coveringg concretein any position not otherwise specifically provided forand remove all the debris to a place earmarked by civic body,complete all as specified and directed by Engineer-in-Charge. |
| 13 | Uprooting completely natural vegetation/ plants, stems of trees (upto 30cm girth) grown up on walls, parapets or in roofor any part of building upto 10 metre (Ground +2 storey) and making good the damaged/ disturbed portion and filling holes in cement mortar (1:3) or PCC (1:2:4) type B-0 using graded crushed stone aggregate to match with the existing surface , complete all as specified and directed by Engineer-in-Charge. |
| 14 | First qualityglazed ceramic colouredtiles of450x300x7 mm thick laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste ofhoney like consistancy and pointed in white or coloured cement to match the shadeof tiles in andincluding dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removal of rubbish to a place earmarked by civic body ,complete all as specified and as directed by Engineer -in-Charge.Notes :- (i) Design, pattern and colour of tiles will be as approved by GE. (ii) Tile work to be executed in any position or in any patches or as per site requirement. |
| 15 | First quality, Non skid ceramiccoloured tiles, 7 to 8 mm thick joint free (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white or coloured cement with pigment to match the shade of tiles in andincluding dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) andremoval of rubbish to a place earmarked by civic body ,complete all as specified and as directed by Engineer -in-Charge.Notes :- (i) Design, pattern and colour of tiles will be as approved by GE. (ii) Tile work to be executed in any position or in any patches or as per site requirement. |
| 16 | Steel water tubing, 15 mm bore medium grade ISI Marked, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors in and includingtaking up or down existing unservicable tubing and connections, cleaning for re fixing or removal to store, complete all as specified and directed by Engineer-in-Charge.Notes: (i) Servicable steel water tubingretrived from taking down of this item shall be used after proper cleaning and washing of old GI tube under item No.16.00 below. Nothing extra payment will be paid on this account .(ii) Fittings & specials as required shall be provided by the contractor. Contractor\"s rate shall be deemed to include the cost of fittings provided. |
| 17 | Re-fixing of servicable steel water tubing of 15 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling in and including taking up or down servicable steel water tubing and connections ,complete all as specified and directed by Engineer-in- Charge.Notes: (i) Servicable steel water tubingretrived from taking down ofNo.15 above and this item shall be used after proper cleaning and washing of old GI tube under this.Nothing extra payment will be paid on this account .(ii) Fittings & specials as required shall be provided by the contractor. Contractor\"s rate shall be deemed to include the cost of fittings provided. |
| 18 | Steel water tubing, 20 mm bore medium grade ISI Marked , galvanized with all fittings and fixed complete to walls, ceiling or laid in floors in and includingtaking up or down existing unservicable tubing and connections, cleaning for re fixing or removal to store, complete all as specified and directed by Engineer-in-Charge.Notes: (i) Servicable steel water tubingretrived from taking down of this item shall be used after proper cleaning and washing of old GI tube under item No.18.00 below. Nothing extra payment will be paid on this account .(ii) Fittings & specials as required shall be provided by the contractor. Contractor\"s rate shall be deemed to include the cost of fittings provided. |
| 19 | Re-fixing of servicable steel water tubing of 20 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling in and including taking up or down servicable steel water tubing and connections ,complete all as specified and directed by Engineer-in- Charge.Notes: (i) Servicable steel water tubingretrived from taking down ofNo.17 above and this item shall be used after proper cleaning and washing of old GI tube under this.Nothing extra payment will be paid on this account .(ii) Fittings & specials as required shall be provided by the contractor. Contractor\"s rate shall be deemed to include the cost of fittings provided. |
| 20 | Rotational moulded PVC, tripple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. including Ball valve high pressure of PTMT with epoxy coated aluminium door and high density plastic ball screwed for 20mm dia iron pipe and fixed (minimum wieght 20mm 210gms) in and including dismantling PVC water tanks exc 250 ltr but n. exc 500 ltr capacity by disconnecting existing water connection and removal from site,complete all as specified and directed by Engineer-in- Charge. |
| 21 | Rotational moulded PVC, tripple layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. including Ball valve high pressure of PTMT with epoxy coated aluminium door and high density plastic ball screwed for 20mm dia iron pipe and fixed (minimum wieght 20mm 210gms) in andin and including dismantling PVC water tanks exc 500 ltr but n. exc 1000 ltr capacity by disconnecting existing water connection and removal from site,complete all as specified and directed by Engineer-in- Charge. |
| 22 | Ball valve high pressure of PTMT with epoxy coated aluminium door and highdensity plastic ball screwed for 20mm dia iron pipe and fixed 20mm 210gms/25mm 455gms/40mm 690gms ) and fixed as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Angle cock, 15 mm borefancy type chromium plated cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Bib cock long body with flange,15 mm bore fancy type cast copper alloy Chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Pillar cock, lobg neck fancy type cast copperalloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l\"ettered \" \"HOT\" or \"COLD\" with long screwed shanks and fly-nuts , screwed for iron pipefixed as in repair , complete all as specified and directed by the Engineer in -Charge. |
| 26 | Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 20 mm bore dia fixed as in repair , complete all as specified and directed by the Engineer in -Charge. |
| 27 | Vitreous China squating pan, \"Orissa\"pattern, size 580x440mm white, with integral foot rests, including 100mm cast iron \"P\" or \"S\" trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor fixed as in repair , complete all as specified and directed by the Engineer in -Charge.Note :- Qty andRates are inclusive of for both P type and S type Traps as on actual required basis on ground |
| 28 | Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc including 100mm cast iron \"P\" or \"S\" trap complete including making good to floor fixed as in repair , complete all as specified and directed by the Engineer in -Charge.Note :- Qty andRates are inclusive of for both P type and S type Traps as on actual required basis on ground |
| 29 | PVCvalveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level fixed as in repair , complete all as specified and directed by the Engineer in -Charge. |
| 30 | PVC connections 15mm size with PTMT nuts of length 600 mm fixed as in repair , complete all as specified and directed by the Engineer in -Charge. |
| 31 | Hand shower (Health foucet) cast copper alloy chromium plated with and including 8mm dia 1.25 meter long CP flexible tube and with hook fixed as in repair , complete all as specified and directed by the Engineer in -Charge. |
| 32 | Disconnecting existing tanks of capacity exceeding 250ltrs but n. exceeding 500ltrs, draining out of water, setting a side( or lowering if required) for repair/cleaning and removing accumulated sluge/dirt scales from tank bottom, side and from mouths of circulating pipes of service tanks located on roof of building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enemel paint on black ground \"Cleaned on (date)\" height of words100mm, and hoisting if required, refixing and reconnecting in position after cleaning,complete all as specified and directed by Engineer-in- Charge. |
| 33 | Disconnecting existing tanks of capacity exceeding 500ltrs but n. exceeding 1000ltrs, draining out of water, setting a side( or lowering if required) for repair/cleaning and removing accumulated sluge/dirt scales from tank bottom, side and from mouths of circulating pipes of service tanks located on roof of building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enemel paint on black ground \"Cleaned on (date)\" height of words100mm, and hoisting if required, refixing and reconnecting in position after cleaning,complete all as specified and directed by Engineer-in- Charge. |
| 34 | PVC (SWR) pipes 110 mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets and making good the mouth of rain water pipe with PCC 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates and finished the surfaces even and smooth with cement mortar 1:3 including taking down old pipes,complete all as specified and directed by Engineer-in- Charge. |
| 35 | PVC (SWR) bends any radius 110mm borefixed with solvent cement in any position as per site requirement fixed as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 100mm bore of pipe fixed as in repair , complete all as specified and directed by Engineer-in-Charge. |
| 37 | Note :Schedule of creditto be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse. |