| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: as per DSR. No. 4.1.10 |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:5:10 (1 cement: 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources) , as per DSR No.4.1.10 |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand), as per DSR No.6.2.2. |
| 4 | Filling available excavated earth in trenches, sides of foundation etc. in layers consolidating all deposited layer by ramming and watering , as per DSR No.2.25. |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) required for proper Completion of work as per DARNo.6.4.2. |
| 6 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). as per DSR No. 4.11 |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). as per DSR No. 5.3 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform etc. required for proper Completion of work as per DSR No.5.9.3 |
| 9 | Reinforced cement concrete work in walls including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fromnatural sources)as per DSRNo.5.2.2 |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. as per DAR No.5.22A.6Hard drawn steel wire. as per DAR No.5.22A.2 |
| 11 | SAME AS ABOVE |
| 12 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). as per DSR No.9.1.1 |
| 13 | 15 mm cement plaster on the rough side of singleor half brick wall of mix : 1:6 (1 cement: 6 coarse sand) for Proper completion of work, as per DSR No.13.5.2 |
| 14 | 12 mm cement plaster on the inner side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) for Proper completion of work, as per DSR No.13.4.2 |
| 15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. As per DSR 11.41.2 |
| 16 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Kiln seasoned and chemically treated hollock wood 35 mm thick shutters. As per DSR 9.5.2.1 |
| 17 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 Itr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sgm for proper Completion of work as per DSR 13.47.1 |
| 18 | Colour washing to give an even shade; interior colour of required shade: New work (Two or more coats) with base coat of white washing with lime for proper Completion of work as per DSR 13.39.1 |
| 19 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs etc as directed by Engineer-in-Charge and consisting of :. for proper Completion of work as per DAR No.22.7.1 |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C , As per DSR(E&M) 1.10.3 |
| 21 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required 32A TP&N As per DSR(E&M) 2.1.1 |
| 22 | Providing and fixing aluminium handles, ISI marked, anodized transparent or dyed to required coloured or shade, with necessary screws etc. complete as per DSR 9.100.1 |
| 23 | Providing and fixing factory made glazed shutter conforming to IS; 14616 and TADS 15:2001, using 4mm. thick float glass pane for doors, windows with butt hinges necessary screws, all complete with directions od engineer in charge DSR 9.10.1 |
| 24 | Providing and fixing aluminium tower bolt, ISI marked, anodized transparent or dyed to required coloured or shade, with necessary screws etc. complete as per DSR 9.97.1 |
| 25 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door , As per DSR(E&M) 2.4.3 |
| 26 | CONTIGENCIES 1% Please Enable Macros to View BoQ information |