| 1 | Clearing Jungle including Uprooting of rank, Vegetation, Grass,brush Wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 mtr. Outside the periphery of the Area Cleared. As per DSR Code No. 2.31 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas ( exceeding 30 cm in depht, 1.5 m width as well as 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out and disposal of excavated earth lead up to 50 m and for lift,as directed by Engineer-in-charge. All kinds of soil. As per DSR Code No. 2.6.1 |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, dides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and for all lift. As per DSR Code No . 2.25 |
| 4 | Providing and Laying in Position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to Plinth level: 1:5:10 (1 cement :5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) as per DSR code No. 4.1.11 |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). As per DSR Code No-5.1.2 |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand). As per DSR Code No- 6.1.2 |
| 7 | Centering and shuttering including stutting, propping etc. and removal of form for Lentels, beams, plinth beams, girders, bressumers and cantilevers, As per DSR Code No- 5.9.5 |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Level. As per DSR Code No-5.3 |
| 9 | Centering and shuttering including stutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access plateform. As per DSR Code No- 5.9.3 |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per DSR Code No.- 5.22.6 |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ). As per DSR Code No 6.4.2 |
| 12 | 12 mm thick cement plaster of mix 1:6 ( 1 cement : 6 fine sand ) As per DSR Code No 13.1.2 |
| 13 | 12 mm cement plaster 1:3 ( 1 cement : 3 Coarse sand ) Finished with a Floating cost of neat Cement. As per DSR Code No 13.9.1 |
| 14 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) As per DSR Code No-13.46.1 |
| 15 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface. As per DSR Code No-13.80 |
| 16 | Providing and Fixining Angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x5 mm flat pleces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-in-charge. As per DSR Code No.10.31 |
| 17 | Providing and Fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fitting complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for digonal braces and central cross price. As per DSR Code No.10.5.2 |
| 18 | Painting with synthetic enamel paint of approved brand and manufature of required colour to give an even shade : Two or more coals on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. As per DSR Code No.13.62.1 |
| 19 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded Stone) finished with floating cost of neat cement, including cement slurry but excluding the cost of nosing of steps etc.40 mm.thick floor 20 mm nominal size stone aggregate. As per DSR Code No. 11.3.1 |
| 20 | Providing and Fixing 18mm thick gang saw cut. Mirror polished, premoulded and preplolished, machine cut for kitchn platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cemen : 4 coarse sand ), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm. As per DSR Code No. 8.2.3.2 |
| 21 | Providing and Laying of interlocking concrete Block Pavment having thickness 80 mm as per drawing and technical specification clause 1504( Exlusive GSB) |
| 22 | Earth work excavation by mechanical means ( hydraulic excavatory) / manual means over areas ( exceeding 30 cm in depth, 1.5 m in width as wall as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and for all lift, as directed by Engineer-in-charge. all kinds of soil. As per DSR Code No.2.6.1 |
| 23 | Providing and Laying in Position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to Plinth level: 1:5:10 (1 cement :5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) as per DSR code No. 4.1.11 |
| 24 | Providing and Laying Ceramic glazed floor tiles of size (300x300) mm thickness to be specified by the manufacturer of 1st quality conforming to IS : 15622 of approved make in colours such as white, lvory, Grey, Fume Red Broun, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 Coarse sand), joint with grey cement slurry @ 3.3 kg/sqm including pointing the joint with white cement and matching pigment etc. complete. as per DSR code No. 10.37 |
| 25 | Providing and fixing 1st Quality Ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacture), of approved make in colours shades excepd burgundy, bottle green, black of any size as approved by Engineer-in charge, in skirting, risers of steps of any dodos, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 Coarse sand), and joint with grey cement slurry @ 3.3 kg/sqm including pointing with white cement mixed with pigment of matching shade complete. as per DSR code No. 8.31 |
| 26 | Providing and Laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skiting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6mm thickness, including grouting of joints (payment for grouting of joints to be made separately), size of tile 600x600 mm. per DSR code No. 11.47.2 |
| 27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand). As per DSR Code No- 6.1.2 |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Level. As per DSR Code No-5.3 |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per DSR Code No.- 5.22.6 |
| 30 | Providing and fixing water closet squatting pan ( Indian type W.C.Pan) with 100 mm |
| 31 | Providing and fixing white viteous china pedestal type (Europeantype) |
| 32 | Providing and fixing white viteous china flat back or wall comer type. |
| 33 | Providing and fixing white viteous china pedestal for wash basin complete. |
| 34 | Providing and fixing of steel sink with out drainage board 530x345 mm. |
| 35 | Providing and fixing chlorinated polyvinyl chloride (C.P.V.C.) pipes. |
| 36 | Providing and fixing chlorinated polyvinyl chloride (C.P.V.C.) pipes. |
| 37 | Supply of C.P. bib cock heavy quality (Gem mikadeo/Encess\"s willams) |
| 38 | Providing and Placing on terrace (at all floor levels) polythylene water supply. |
| 39 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR-22 E&M Code no. 1.10.1 Light Point |
| 40 | Supplying and Wiring of submain 2 number 4.0 sqm. FR PVC insulated. |
| 41 | Same as DAR No. 1 but for 5 amp plug point with piano type switch. |
| 42 | Erection and testing of ceiling fan regulator for room height up to 3.5 mm. |
| 43 | Providing and fixing of Hexagonal Fan box with hexagonal side of approx 80mm in length etc. |
| 44 | Supply and fixing of LED Tube Light with batten suitable for up to 1x22 amp. |
| 45 | Construction of recess distribution board of all sizes including etc. |
| 46 | Supplying and fixing of flush/surface mounting distribution board complete. |
| 47 | Supplying and fixing of 240 volts L series miniature circuit breaker 9 K.A. etc. |
| 48 | Supply and fixing of power plug with 15 A / 250 v flush type switch etc. |
| 49 | Supply and fixing of 6 Amp. To 32 Amp. DP MCB (10 KA) C Curve as S.I. No. 1009. |
| 50 | Supply and fixing of recess / surface / pendent mounting round 6 watt 8 watt etc. Please Enable Macros to View BoQ information |