| 1 | CIVIL WORK |
| 2 | Earth work excavation for foundation in all classes of soils and sub-soils and to full depth as may be directed except in hard rock requiring blasting including initial leads and lifts and refilling the sides of foundation with excavated earth in 150 mm layers well watered, rammed and consolidated including depositing surplus earth within the godown or inside compound in places shown with initial lead of 10 mts and initial lift of 2 mts. Clearing, eveling the site, shoring, strutting, bailing of water wherever necessary etc., complete complying with standard specification and as directed. |
| 3 | Supplying and filling in foundation with Gravel in layers of not exceeding 150mm thick well watered, rammed and consolidated including watering etc., complete complying with standard specification and as directed. |
| 4 | CEMENT CONCRETE 1:5:10(one cement, five sand and ten aggregate)using 40mm gauge hard broken granite stone jelly for foundation including mixing by mechanical means de-watering side shuttering , strutting, wherever necessary including curing etc., complete complying with standard specifications and as directed. |
| 5 | upplying and laying of Ready mix 15 Grade for the following grade of concrete having characteristic strength not less than specified in the IS 456 - 2000 using Ordinary Portland cement with minimum cement content of 366 Kg / cum confirming to IS 8112. Coarse aggregate having a specific gravity of 2.60 using 20 mm down graded hard blue granite broken stone jelly and fine aggregate without fly ash as per IS 383 - 1970 (2007) with suitable water cement ratio not less than 0.45 of water quality confirming to IS 456 - 2000 including use of plasticizer of approved make & dosage of required grade at all location and levels with specified high workability as per IS 1199 - 1959 (2004). The initial & final setting time confirming IS 12269 - 1987 (2004) .The admixtures affecting the quality and strength of the confirm IS 9103 - 1979 [ usual admixture - Air entraining & water reducing In foundation and basement. |
| 6 | Supplying, fabricating and placing in position MS/RTS grills for reinforcement for all R.C.C.works including cost of steel, labour for straightening, bending, cranking, tying grills with 18 gauge galvanized binding wire and placing grills in position complete complying with standard specification and as directed. |
| 7 | Providing FORM WORK for centering the soffits of all reinforcement concrete work including strutting to the required (3 metre) height with mild-steel sheets of size 90cmx60cm 10 gauge stiffened with welded mild steel angles of size 25mmx25mmx3mm laid with country wood joist of average of size 10cmx6.50cm at about 90cm centres with casurina props of 13cm dia at 75cm centre to centre with all nails coir,wedges complete and removing the form work after necessary curing period as directed by the corporations officers. The rates should inclusives of cutting , bending, welding , charges of M.S sheets, M.S. angles etc., CompleteRectangular beams, floor slab, tie beams, lintels, landing slab, loft etc., |
| 8 | BRICK WORK in cement mortor 1:5(one cement, five sand) using best quality Country bricks of size 8\" 3/4\"x4 ¼ x 2 ¾ “ for walls including cost of scaffolding curing, finishing etc., complete complying with standard specification and as directed by the departmental officers. |
| 9 | PLASTERING with cement mortor 1:3 (one cement and three sand) 10mm thick including cost of scaffolding, finishing, curing etc., complete complying with standard specification and as directed. |
| 10 | PLASTERING with cement mortor 1:5 (one cement and five sand) 12mm thick including cost of scaffolding, finishing, curing etc., complete complying with standard specification and as directed. |
| 11 | Painting the walls with two coats of Interior / Exterior emulsion paint of first class approved quality and colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed. |
| 12 | Supplying, fabrication and fixing of M.S pipe for vertical stanction and forming truss used with M.S Rectangular section and necessary M.S.angles for cleat for purlins M.S square pipe has to be fabricated as per the corporation specification and as directed by the departmental officers. |
| 13 | Supplying and laying of High profile colour galvalume sheet (as per ISI Standard) with combination 55A1:43 4Zn:1:6SI of TCT bent type 0.47mm thick not less than 150 GSM and standard width of 1.06m with yield strength of 550 MPA made from high tensile/ CR sheets of approved quality for roofing with necessary fixing arrangements like 65m and long hexagonal head screws with EPDM rubber seal etc., complete, complying with standard specification and as directed by the departmental officer. (Test certificate for quality should be furnished on receipt of material at site) |
| 14 | Supplying and fixing of 40 X 6mm G.I Flat over the galvalume sheet roofing which is placed on the top of Purlin in the longitudinal direction to avoid the lifting of roofing during heavy wind. The rate is inclusive of GI screws 75mm length with rubber and aluminium washer, drilling hole over GI Flat to hold the sheet and purlin with necessary adhesive flashing tap directly over the galvalume sheet including labour charges for fixing, conveyance, loading, unloading and cutting etc. complete as directed by the departmental officers. |
| 15 | Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) |
| 16 | Supply and installation of 10 KVA 3 Phase Kirloskar make Diesel generator with engine model 3R550NA 4G1 liquid-cooled, 3-cylinder genset. Frequency Hz50 Power Factor lagging 0.8 VoltageV230 (1Ø) & 415 (3Ø)Governing class (As per ISO 8528 Part-V) G2DG Set Noise level at 1 meterd BA < 75 (Genset with canopy) Fuel tank capacity (Standard DG set) Ltrs 32µ Weight of genset with canopy (approx.) ^Dry Kg 585 Wet (w/o fuel) Kg 590 Overall dimensions of genset ^Length mm 1800 Width mm 760 Height mm 1050 Electrical Battery Starting Voltage Volts -DC12.ENGINE Model3R550NA 4G1Rated output (Prime Continuous rating as per ISO 8528-1) kW11HP15Cooling system Liquid No. of cylinder Number 3 Cubical capacity2Ltrs1.65Bore x Strokemm86 x 94Rated SpeedRPM1500AspirationNA/TC/ TANALube Oil change periodhrs.500Lube oil Sump Capacity (max) Ltrs 5.95 Coolant Capacity (Engine + Radiator) Ltrs 3.78.ALTERNATORInsulation Class Class H Alternator Efficiency (at 100% load) 0.8 pf**%82.6Max Voltage Dip at Full Load 0.8 pf lagsec < 20 %Max Time to build up rated voltage at Rated RPM< 2 sec, provided engine reachthe rated speed etc., complete complying with standard specification and as directed by the departmental officer. |
| 17 | Supply and clamping of 3 x 1.5 Sq.mm PVC LTUG armoured copper cable on post or on wall with MS clamps.(for lights power supply) etc., complete complying with standard specification and as directed by the departmental officer. |
| 18 | Supply and laying of 2 x 16 sq.mm sized PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 Mtr Putting 0.15mt layer of sand and covering the three sides of the cable with bricks and refilling the earth to make good etc., complete complying with standard specification and as directed by the departmental officer. |
| 19 | Supply and fixing of brass cable gland for 2 x 16 sqmm PVC armoured LTUG cable with earth connection etc., complete complying with standard specification and as directed by the departmental officer. |
| 20 | Provision for Earth work using JCB machine for cable laying work at hard /rocky soil .The cost includes hire charge of machine, fuel charges and other incidental charges, etc., complete complying with standard specification and as directed by the departmental officer. |
| 21 | Earthing as per PWD standard with an earth Electrode of 2Mtr Class -B G.I pipe of dia not less than 32mm complete with necessary masonary work etc., complete complying with standard specification and as directed by the departmental officer. |
| 22 | Supply and fixing of 3phase 500 Volts / 63A automatic phase shifted switch units and suitable MS angle iron works etc., complete complying with standard specification and as directed by the departmental officer. |
| 23 | Supply and fixing of 32A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with Earth connection only etc., complete complying with standard specification and as directed by the departmental officer. Please Enable Macros to View BoQ information |