| 1 | NOTE: Schedule ‘A’ Part - ItoPart -IXare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 |
| 2 | Total amount of Sch \"A\" Part - I (BUILDING WORKS) |
| 3 | Total amount of Sch \"A\" Part - II(SITE CLEARANCE/ AREA DEVELOPMENT/ EXCAVATION AND EARTHWORK) |
| 4 | Total amount of Sch ‘A’ Part - III (INTERNAL ELECTRIFICATION WORKS) |
| 5 | Total amount of Sch ‘A’ Part - IV (INTERNAL WATER SUPPLY) |
| 6 | Total amount of Sch ‘A’ Part - V (SEWAGE DISPOSAL) |
| 7 | Total amount of Sch ‘A’ Part - VI (ROAD/ PATH) |
| 8 | Total amount of Sch ‘A’ Part - VII (EXTERNAL WATER SUPPLY) |
| 9 | Total amount of Sch ‘A’ Part - VIII (EXTERNAL ELECTRIFICATION WORKS) |
| 10 | Total amount of Sch ‘A’ Part - IX (HOT WATER SUPPLY) |
| 11 | SCH \"A PART - X(Miscellaneous B/R and E/M works for Sch \"A\" Part-II to Part-IX)Note: This schedule is not pre-priced by MES and the rate indicated as \"Rs 0.00\" under Col 5 signifies this fact only |
| 12 | Rechargeable LEDBulb 9 W, 220 V, white color all as specified and as directed. |
| 13 | GIPipe (medium grade, ISI Marked) 32 mm dia ,1.5 mtr long ,bend to shape for street light fitting bracket ,with 2x pairs of MS clamps of suitable length of size 40x5 mm of MS flat iron with nuts bolts and washer and taking out old one including connection with street light complete all asdirected. |
| 14 | 40W Tube insect catcher electric insect killer indoor type (fly swatter) with complete connection complete all asspecified and directed. |
| 15 | Duct type chimney with inbuilt exhaust fan , from opening top of kitchen platform opening 1.5m x .6m with all insulation and fitting complete all asspecified and directed. |
| 16 | M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 20mm outer dia 22/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge. |
| 17 | All as per Srl item No 16 above, but of size 25 mm dia. |
| 18 | Supply, Installation, testing & commissioning ofself supportingtotally enclosed double door at front, LT feeder pillar box compartmentalized design, dust and varmin proof of size 600 mm(Height) x 600 mm(Length) x 450 mm(Width)suitable for 440 Volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprene rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Chromium plated and nuts, bolts ;and washers etc. The panel shall be synthetic enamelled paintedand the control circuit diagram shall bewith colour code solid conductorcopper 1.5 sqmm cable for easy identification including incoming/outgoing cable holes at the bottom, complete after taking down the old unserviceable one.The Panelshall be emmbeded with 75 x 6 mm MS Angle Iron frame and to be grouted with PCC foundation (1:2:4 )type B2 upto a height of 50 cm from normal ground level complete all as specified and directed by Engr in charge and comprising of the following. |
| 19 | (a) Aluminium bus bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable sizeof brass nut, bolts and washer with heat shrinkable PVC sleeving.The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB TPN, 63 A, 10 KA, with breaking capacity of 25 KA, Make : L & T/Havells - 01 No.(c) MCB of TPN, 40, 10 KA,Make : L & T/Havells - 03 Nos.(d) LED Indicating lamps for Main Supplyindicating R\", Y\" B\"- 01 Set of 3. (e) Digital Voltmeter (Make AE/L&T) - 01 No.(f) Current Transformer havingRatio 400/5, 15 VA- 01 Set of 3.(g) Digital Ammeter ( Make(AE/L&T) - 01 No. |
| 20 | Supply and fix Stand Alone Heater with heating capacity of25000 Kcal/Hr with 2 HP blower motor and complete accessories:-(a) No of Passes - 04 Passes, (b) Hot Air Temp- 80 Degree C, (c) Process Air Flow at STP (1.2 Kg/m3 air density)- 80 Degree C, (d) Thermal Efficiency - 90%(e) Fuel Type - Diesel/Kerosene, (f) Max Fuel Consumption (HSD) - 1.2 kg/hr (on full load however fuel consumption will vary depending on process temperature and air requirement)(g) Electricity Supply - 415±6%, 50Hz±3%, 3 Phase, 4 wire, (h) Fuel filter and tank - Provided, 10 Ltr(j) Burner - burner fitted with imported(k) Blower Fan - Double inlet backward curved centrifugal fan suitable for high pressure upto 80mmwc(l)Blower Motor -FHP, Standard make (ABB/Siemens/Equivalent) for up to 25000 Kcal/hrs size(m) Drive - Belt driven through taper lock pulleys and belt to adjust RPM as per process air flow and pressure requirements, (n) Temperature Control - Automatic through digital temperature controller(o) Control Panel- Pre-wired powder coated control panel with user friendly audio-visual controls, safeties, interlocks, MCB, overload relays, timers and alarm hooter(p) Blower fan guard, (q) Outer Body - Fabricated out of mild steel duly insulated from inside and 1 Mtr exhaust pipe of aluminium sheet 1.6 mm.Make: Alfatherm/Jevica/Equivalent |