| 1 | Earthwork in excavation by manual means upto a depth of 2 m below the existing ground level for foundation trenches of foundations footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils(b) In ordinary rock (Soft rock/ medium rock/ hard shale) |
| 2 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.(b) Stone soling(i) 100 mm |
| 3 | Plain cement concerte floor base in prop 1:3:6 laid in alternate bays as specified with coarse aggregate of size 13 mm to 32 mm including dewatering if necessary, and curing etc complete.(c) 100 mm thick in prop 1:3:6 |
| 4 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layer not exceeding 20 cm thickincluding breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m(a) With available excavated earth. |
| 5 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement : 6 course sand : 12 graded stone aggregate 20 mm niminal size) up to plinth level with:(a) Cement mortar 1:6 (1 cement : 6 course sand) |
| 6 | Supplying, fitting and fixing in position reinforcement bars upto 1st floor level, conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurements for the same is required)(b) Thermo - Mechanically Treated Bars |
| 7 | Shuttering/ FormworkCentering and shuttering including strutting, propping etc and removal of form for all heights complete and as directed by Engineer incharge. |
| 8 | 4.4) Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel) |
| 9 | 4.3) Slabs, roofs landings, balconies and access platform, shelves (using steel) |
| 10 | 4.5) Columns, pillars, piers, abutments, post and struts (using steel) |
| 11 | Providing and layingin position specified grade ofReinforced Cement Concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: (b) M20 or Prop. 1:11/2:3 (1 cement : 1 1/2 course sand : 3 graded stone aggregate 20mm nominal size. |
| 12 | Reinforced cement cocrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts ans struts etc. above plinth level upto first floor level, excluding cost of centering, shuttering, finishing and reinforcement.(b) M20 or 1:1/2:3 (1 cement: 1/2 coarse sand: 3 graded stone aggregate 20mm nominal size) |
| 13 | Extra over item no. 6.2 to 6.8 above for each subsequent floor or part thereof above the first floor level.(b) M20 or 1:1/2:3 (1 cement: 1/2 coarse sand: 3 graded stone aggregate 20mm nominal size) |
| 14 | Brick work in cement mortar with first class brick in super structure above plinth level up to first floor level in all shapes and sizes:(a) Cement mortar 1:4 (1 cement : 4 course sand) |
| 15 | Extra over item no.7.3 above for each subsequent floor or part thereof above the first floor level.(a) Cement mortar 1:4 (1 cement : 4 course sand) |
| 16 | Cement plaster in fine sand15 mm cement plaster on the rough side of single or half brick wall of mix:(a) 1:4 (1 cement : 4 fine sand) |
| 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approvedmake contormingtols:733andls:1285,fixingwith dash fasteners of required diameter and size,including necessaryfillingupthegapsatjunctions,i.e.attop,bottom andsideswithrequiredEPDMrubber/ neoprenegasketetc. Aluminiumsectionsshallbe smooth,rust free,straight,mitred andjointed mechanicallywherever required including cleat angle, Aluminium snapbeadingforglazing/panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawingsandthedirectionsofEngineer-in-charge.Glazing, and panelling to be paid for separately) |
| 18 | Providing & fixing glazing in aluminium door,window,ventilator shutter and partitions etc with EPDM rubber/ neoprene gasket etc, complete as architectural drawings and direction of engineer incharge.(a)With float glass pandes of6.0mm thick glass panes. (weight not less than 15kg/sqm) |
| 19 | (b)With float glass pandes of4.0mm thick glass panes. (weight not less than 10kg/sqm) |
| 20 | Providing and fixing :Double action hydraulic spring |
| 21 | Providing and fixing: Twin rubber stopper |
| 22 | Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred& jointed with self- driven self tapping screws of size 38x4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia. & length anchor fastener as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 23 | Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The stiles & rails shall be of size 75x30 mm having wall thickness 5 mm. The stiles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side and rails shall be reinforced with M.S. tubes of size 33x17x1 mm, painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the stiles and the rails with a cavity, to receive single piece extruded 5 mm PVC sheet as peanel. The stiles and rails will be mitred cut and joint with help of PVC solvent cement & self-driven self tapping screws. Single piece extruded solid PVC lock rail of size 100x30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle pf the lock rail & fixed with stiles with the help of PVC Solvent cement & self driven self- tapping screws of size 100x8 mm complete as per manufacturer\"s specifications and direction of Engineer-in-charge.(a)Non decorative finish |
| 24 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mmand braced with flat iron diagonals 20x5 mmsize with top and bottom rails of T-iron 40x40x6 mm, with 40mm dia. steel pulleys, complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of approved steel primer. |
| 25 | Cement concrete floor topping 1:1:2 (1cement : 1 coarse sand : 2 stone aggregates finished with a floating coat of neat cement including cement slurry, complete .(ii) 20 mm thick |
| 26 | Providing ceramic Antiskid Tiles of approved quality size, shape not less than 8 mm on floor, skirtung over a cement mortar bed 15 mm thick of 1:3 (1 cement: 3 coarse sand) complete at all level as specified and directed.(a) Normal range |
| 27 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours and shades of any size as approved by the Engineer-in-charge, in walls, skirting, risers of steps and dados, over 12mm thick bed of Cement mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 Kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(a) Normal Range |
| 28 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 liter low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with allfittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 29 | Providing and fixing wash basin with CI brackets, 15mm C. P. brass pillar taps, 32mm C. P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:(g) White Viterour China Flat back wash basin size 450x300 mm with single 15mm C. P. brass pillar tap |
| 30 | Providing and fixing soil, waste and vent pipes:(a) 100 mm diameter(i) Sand cast iron S & S pipe as per IS: 1729 |
| 31 | Providing and fixing soil, waste and vent pipes:(a) 100 mm diameter(i) Sand cast iron S & S pipe as per IS: 1729 |
| 32 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete with sand cast iron S&S as per IS: 1729:(a) 100 mm dia. |
| 33 | Providing and fixing G.I pipes complete with G.I fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall(i) 15mm diameter nominal bore |
| 34 | Providing and fixing brass bib cock of approved quality:(a) 15 mm nominal bore |
| 35 | Providing and fixing brass bib cock of approved quality:(a) 15 mm nominal bore |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC Plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipe & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work- Exposed on wall(i) 15 mm nominal outer diameter Pipes |
| 37 | Providing and fixing G.I. Union in G.I pipe including cutting and threading the pipe and making long screws etc. complete (New work):(a) 15 mm nominal size |
| 38 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I brackets and stainless steel plug 40 mm, including painting the fitting and brackets, cutting and making good the walls wherever required:(a) Kitchen sink with drain board(i) 510x1040 mm bowl depth 250 mm |
| 39 | Providing and fixing M.S. grills of required pattern in frames of windows, etc. with M.S. flats, square or round bars, etc. including priming coat with approved steel primer all complete.(a) Openable |
| 40 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces:Water thinnable cement primer. |
| 41 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 42 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufactures specifications, including scaffolding(c) Painting Steel work with Deluxe Multi surface Paint to give an even shade. Two or more coats applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manudacture. |
| 43 | Finishing walls with textured exterior paint of required shade, including scaffolding:(a) New work (Two or more coats applied @ 3.28 kg/10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm. |
| 44 | Item no.1 Extra for carriage including loading and unloading all charges complete beyond the initial lead (Umeitto 132KV Nongpoh SS) 36-5=31 Km |
| 45 | 1.3 carriage of stone aggregate |
| 46 | 1.3 carriage of sand |
| 47 | Making 2.15 height partition with both side 6mm thick plywwood at the lower half portion and 6mm thick glass panes at the upper remaining portion, fixed on wooden frame (0.05x0.075)m. Glass is fixed with Tita Champa beading including 2(two) coats of primer and enamel paint of best quality complete as directed. |
| 48 | Providing flush door of 35mm thick wooden frame, provided with 12mm thick plywood at the lower panell and 6mm thick glass panes at the upper panell of the door, complete with chowkat including mortice lock, hydraulic door closer and two coats of primer and synthetic enamel paint of best quality complete as directed. |