Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 05-01-2026 |
| Sl. No. | Item Description |
| 1 | Earth work in surface excavation exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Supplying and Filling in Plinth with Sand Under Floors including watering ramming consolidating and dressing complete |
| 4 | Clearing grass and removal of Rubbish upto the distance of 50 m outside the area of periphery cleared |
| 5 | Supplying chemical emulsions in sealed containerincluding delivery at site Chlorpyriphos/Lindane Emulsifiable concentrate of 20% |
| 6 | Diluting and Injecting chemical for Post constructional anti termite treatment Excluding the cost of chemical emulsionTreament of Soil under existing floors using chemical emulsion @ 1 litre per hole,300 mm apart using 12 mm dia drilling holes and plugging with CM1:2 to match esisting floorWith Chlorphyros/Lindane E.C20% with 1% concentration |
| 7 | Treatment at point of contact of wood work by chemical emusion chlorpyriphos/Lindane in oil or kerosene based [email protected] per holes, by drillng 6 mm dia holes, at downward angle of 45 degrees@150 mm centre to centre and sealing the same |
| 8 | Providing and Laying cement Concrete 1:4:8(1cement:4 coarse sand(Zone-III):8graded stone aggregate 40 mm nominal size derived from natural resources) |
| 9 | Providing and Laying cement concrete in Retaining Walls Return Walls inlcuding attached pilasters,columns, piers, abutments, pillars posts struts, buttress,strings or laces courses, parapet,coping,bedblocks,anchorblocks,plain window sills fillets,sunken floor etc upto floor level five, excluding the cost of centreing shuttering and finishing1:3:6(1cement:3 coarse sand(Zone-III): 6graded stone aggregate 20 mm nominal size derived from natural resources) |
| 10 | Providing and Laying cement concrete in Retaining Walls Return Walls inlcuding attached pilasters,columns, piers, abutments, pillars posts struts, buttress,strings or laces courses, parapet,coping,bedblocks,anchorblocks,plain window sills fillets,sunken floor etc upto floor level five, excluding the cost of centreing shuttering and finishing1:1.5:3(1cement:1.5coarse sand(Zone-III): 3graded stone aggregate 20 mm nominal size derived from natural resources) |
| 11 | Centering and Shuttering including strutting propping etc and removal of formwork for walls including attached pilasters,buttresses, plinth,string courses etc |
| 12 | Centering and Shuttering including strutting propping etc and removal of formwork for Foundation, Footings and Bases of columns For mass concreting |
| 13 | For columns,abutmnets, posts,Pillars, Abutments |
| 14 | Suspended floors roofs landingsbalconies and access platforms with waterprrof ply 12mm thick |
| 15 | Lintels beams bressumers girders and cantilevers with water prrof 12 mm thikc ply |
| 16 | Stair except spiral stair case |
| 17 | Providing and Laying Damp Proof Course 50 mm thick with cement concrete1:2:4(1cement:2 coarse sand(Zone-III): 4graded stone aggregate 20 mm nominal size derived from natural resources) |
| 18 | Making Plinth Protection 50 mm thick of cement concrete1:3:6 over 75 mm thick bed of Dry Brick Ballast 40 mm nominal size well rammed and consolidated and grouted with Fine Sand including necessary excavation, levelling, & dressing and finishing the top smooth |
| 19 | Providing and Laying in Position ReadyMix or site batched design cement concrete for reinforced cement concrete using coarse aggregate and fine aggregate derived from natural resources,OPC/PPC/Portland slag cement admixtures in recommended proportions as per IS 9103 to accelerate retard strength of concrete,toimprove durability,workability without imparing strength of concrete,including puming of concrete to laying, curing, carriage, for all leads, but excluding cost of centering, shuttering, reinforcement and finishing, as per directions of Engineer-Incharge for following grades of concrete.Extra cement to the extent of 10% of minimum specified cement content shall be payable seperately. Incase the cement content of Design mix is more than 110% of specified minimum cement content, the contractor has the discreation to either redesign the mix or bear the cost of extra cementAllworks upto plinth level concrete of grade M-25 with minium cement content of 330kg/cum |
| 20 | All works above plinth level upto Floor 5concrete of grade M-25 with minium cement content of 330kg/cum |
| 21 | Add for using extra cement in the item of Design mix over and above the specified cement content therein |
| 22 | Providing & doing Brick work with common burnt clay bricks FPSnon modularin below foundation of class designate 75 in foundation and plinth in CM1:4 |
| 23 | Providing & doing Brick work with common burnt clay bricks FPSnon modularin below foundation of class designate 75 above plinth in CM1:4 |
| 24 | Half Brick Mansonary with common burnt clay bricks non modular with class deignate 7.5 in super structure above plinth level upto level V in CM1:4 |
| 25 | Providing and Fixing 18 mm thick gang saw cut mirror plshed,premoulded and prepolished,machine cut for Kitchen Platforms,vanity counters,window sills,facias and similar locations of required size approved colour or texture laid over 20 mm thick base cement mortar 1:4(1 cement:4 coarse sand) joints treated with white cement,mixed with matching pigment,epoxy toch ups including rubbing curing,moulding of edges, polishing to give high gloss finish etcGranite stone slab of all colours except black, cherry or ruby red area of slab over 0.50 sqm |
| 26 | Providing edge moulding to 18 mm thick marble stone counters including machine polishing to give high gloss finish etc |
| 27 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 28 | Providing wood work in doors of windows, celestry windows, door frames, wroughed framed and fixing in position,with hold fast lugs and dash fastners, of required dia and length (Hold fast lugs or dash fastners to be paid seperatel) |
| 29 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters: |
| 30 | Extra for providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters confirming to IS2202 part 1 |
| 31 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 32 | Extra for cutting rebate in flush door shutters |
| 33 | Providing & Fixing IS 12817 Stainless steel butt hinges heavy weight with stainless screws complete 125X64X2.50 mm |
| 34 | Providing and Fixing ISI Marked Stainless steel handles 250 mm long 10 mm thick of good quality with necessary screwsas approved by Engineer In Charge |
| 35 | Providing and Fixing ISI Marked Stainless steeltower bolts 250X10 mm Barrel type with necessary screwsof good quality as approved by Engineer In Charge |
| 36 | Providing and Fixing ISI Marked Stainless steel door latch/aldrop 250X10 mm Barrel type with necessary screwsof good quality as approved by Engineer In Charge |
| 37 | Providing & Fixing hanging type door stopper stainless steel including screws |
| 38 | Providing and fixing aluminium extruded section body tubular typeuniversal hydraulic door closer (having brand logo with ISi, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door widthfrom 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 39 | Providing & Fixing Ismarked Aluminum Butt Hingesanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc100X63X3.2 mm |
| 40 | Providing & Fixing Is marked Aluminum Tower bolts barrel typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc250X10 mm |
| 41 | Providing & Fixing Is marked Aluminum Handles typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm |
| 42 | Providing & Fixing Is marked Aluminum Door Stopper typeanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 43 | Providing & Fixing of Aluminum Pull Bolt lockanoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 44 | Providing and Fixing brass finished 100 mortise lock and latch with six leversISI marked with screws etc |
| 45 | Providing & Fixing of Aluminum casement stays anoidic coating not less than grade AC10 as per IS1868 transpared or dyed to required colour or shade with necessary screws etc125mm Twin Rubber Stopper |
| 46 | Providing and Fixing Fly Proof Stainless steel grade 304 to windows and celestry windows using wire guage with average width of aperture 1.4 mm in both directions with wire of dia0.50 mm all complete with 12mm mild steel u beading |
| 47 | Providing & Fixing MSSheet Door Frame of 40X40X6 mm agnle iron3 mm gusset plates at the Junctions,and corners 25 mm dia pulley including all necessary fittings and primer coat of approved steel primer using MS agnles40X40X6 for diagonal braces |
| 48 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 49 | Marble Stone Flooring with 18 mm thick as per sample of marble approved over20 mm thick base of cement mortar 1:4 laid and jointed with grey cement slurry including rubbing and polishing complete Udaipur Green Marble |
| 50 | Extra for prefinishednosing to treads of steps of marble stone |
| 51 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 52 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50%Grey cement |
| 53 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 54 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. (a) Size of Tile 600x600 mm |
| 55 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % andonforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 56 | Grouting the joints of Flooring having joints of 3mm width using epoxy grout of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardnerand 0.20kg of resin per kg including filling grouting and finishing complete as per directions of Engineer In Charge size of tile 600mmX600mm |
| 57 | Providing and laying flamed finish Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade includingrubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. |
| 58 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) |
| 59 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) |
| 60 | 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) |
| 61 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 62 | Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 63 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 64 | Varnishing with varnish of approved brand and manufacture, two or more coats of glue sizing with copal varnish over an under coat of copal varnish over an under coat of flatten varnish |
| 65 | Painting with black anti corrosive bitumin paint |
| 66 | Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 67 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 68 | Providing & Fixing White Vitreous China Pedestal Type Water Closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 69 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever requiredWhite Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 70 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 71 | Providing and Fixing of Health Faucet(CP Brass/SS) with 1 m long flexible tube as approved by Engineer-In-Charge |
| 72 | Providing and Fixing mirror of superior class 600X450mm beveled edge mirror of approved quality complete with 6 mm thick hard board ground fxed to wooden cleats with brass screw and washers complete. |
| 73 | Providing & Fixing 600X120X5mm glass shelf with edges round off supported on anodised aluminium angle frame with CP brass brackets and guard rail complete fixed with 40 mm long screw rawl plug etc complete. |
| 74 | 600 mm long towelSS rail with total length of 645 mm, width 78mm and effective height of 88 mm, weighing not less than 190gms. |
| 75 | Providing and Fixing Drain Pipe PVC for Urinals Heavy Duty as approved by EIC |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.his includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints , cutting, chases making good the wall complete as per direction of Engineer in Charge. Internal work concealed work cutting chasing and making good the wall.20 mm nominal dia pipes |
| 77 | Providing and fixing C.P. brass bib cock of approved quality conforming IS 8931 15mm nominal bore |
| 78 | Providing and fixing C.P. brass bib cock long body of approved quality conforming IS 8931 15mm nominal bore weight not less than 810 gms |
| 79 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 80 | Supply and Installing at site uPVC piping system using Solvent Cement ISI Marked [As perIS4985]with Heavy duty ISI Marked special fittings, Plain Bends ,Door bends, Coupler ,Reducers, Single Tees ,Door Tees, Double Tees, Reducing Tees, Plain, Ys, ,Door Ys, Double Ys, Elbows , Door Elbows,Floor traps(P,S type) etc. Adapters, Air vents, Clamping with GI UClamps as required for firmly installing the pipes. Testing of the system for leakage and Air tightness Complete 75 mm dia pipe(type B soil and Vent pipes) |
| 81 | Supply and Installing at site uPVC piping system using Solvent Cement ISI Marked [As perIS4985]with Heavy duty ISI Marked special fittings, Plain Bends ,Door bends, Coupler ,Reducers, Single Tees ,Door Tees, Double Tees, Reducing Tees, Plain, Ys, ,Door Ys, Double Ys, Elbows , Door Elbows,Floor traps(P,S type) etc. Adapters, Air vents, Clamping with GI UClamps as required for firmly installing the pipes. Testing of the system for leakage and Air tightness Complete 100 mm dia pipe(type B soil and vent Pipes) |
| 82 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal Dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 83 | Extra depth for Manholessize 90X80 cm With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 84 | LayingNon Pressure NP2 Class ( Light Duty ) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1: 2 ( 1 Cement: 2 fine sand) incuding testing of joints and inlcuding trenching ( 750 mm deep) and refiling etc as required etc and connecting it with sewer/manhole : 150mm dia pipe |
| 85 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than4.50 kg and frame to be not less than 2.70 kg as per standard design: 150X100mm size P type |
| 86 | Providing and fixing Sand Cast Iron grating for Gully trap 100 mm |
| 87 | Providing and Fixing SS grating 100 mm (lockable)(100 mm/75mm) dia for floor trap |
| 88 | Makinfg Soak Pit 2.5m dia 3 meter deep with 45X45cm dry brick honey comb shafts with bricks and SW drain pipe 100 mm dia meter 1.8m long complete as per Standard design with common burnt clay FPS non modular bricks pf class designate 75 |
| 89 | Providing and Fixing Float glass panes 4mm thick. |
| 90 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion |
| 91 | For Openable Portion shutters of doors windows and ventilatorsFor shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 92 | Providing and fixing 12 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides. |
| 93 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-chargecomplete. Upto 5mm width and 5 mm depth |
| 94 | Providing & Fixing aluminium casement window fastner of required length for aluminium windows with necessary screws etc Anodised (AC15) Aluminium |
| 95 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.With Average thickness of 120 mm and minimum thickness at Khurrah as 65 mm |
| 96 | Providing and laying water proofing treatment to vertical and horizontalsurfaces of depressed portions of W.C., kitchen and the like consisting ofIst course of applying cement slurry @ 4.4 kg/sqm mixed with waterproofing compound conforming to IS : 2645 in recommended proportionsincluding rounding off junction of vertical and horizontal surface.IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand)mixed with water proofing compound in recommended proportionincluding rounding off junction of vertical and horizontal surface.IIIrd course of applying blown or residual bitumen applied hot at 1.7kg. per sqm of area.IIIrd course of applying blown or residual bitumen applied hot at 1.7kg. per sqm of area. |
| 97 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 98 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. dia upto 25 mm |
| 99 | Steel Reinforcement in RCC Works including straightening, cutting, bending and Fixing in Position, and Binding all complete upto plinth level TMT bars of FE500 or more grade |
| 100 | Steel Reinforcement in RCC Works including straightening, cutting, bending and Fixing in Position, and Binding all complete above plinth level TMT bars of FE500 or more grade |
| 101 | Steel work in built up tubular (Round,Square or hollow sections), trusses including, cutting hoisting fixing in position, and applying a priming coat of approved steel primer,including welding with special shaped washersElectric resistance or induction welding tubes |
| 102 | Steel work in built up sections/ framed sections including cuting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel etc In gratings, frames, guard bars, railings, brackets, gates and similar works |
| 103 | Finishing with Epoxy Paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including approcpiatepriming coat, prepration of surface, etc complete.On Steel work |
| 104 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 105 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 106 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2X6 sq. mm earth wire |
| 107 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 108 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x1.5 sq. mm |
| 109 | Do as above for 6x1.5 sq.mm |
| 110 | Do as above for 9x1.5 sq.mm |
| 111 | Do as above for 3x2.5 sq.mm |
| 112 | Do as above for 6x2.5 sq.mm |
| 113 | Do as above for 9x2.5 sq.mm |
| 114 | Do as above for 3x4 sq.mm |
| 115 | Do as above for 6x4 sq.mm |
| 116 | Do as above for 9x4 sq.mm |
| 117 | Do as above for 3 x 6 sq. mm |
| 118 | Do as above for 6 x 6 sq. mm |
| 119 | Do as above for 9x6 sq.mm |
| 120 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 121 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 122 | Do as abovefor 15/16 A switch |
| 123 | Do as above for3 pin 5/6 A socket outlet |
| 124 | Do as above for6 pin 15/16 A socket outlet |
| 125 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 126 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 127 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 128 | Do as above for 3 Module (100mmX75mm) |
| 129 | Do as above for 4 Module (125mmX75mm) |
| 130 | Do as above for 6 Module (200mmX75mm) |
| 131 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 132 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 133 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 134 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep |
| 135 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N |
| 136 | do as above for 125 A TP&N |
| 137 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 8 way (4 + 24), Double door |
| 138 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle pole |
| 139 | Do as above for Single pole and neutral |
| 140 | Do as above for Triple pole and neutral |
| 141 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 142 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 143 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 144 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 145 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 146 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 147 | Supplying and laying 25 mm X 5 mm G.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) |
| 148 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |
| 149 | Supplying,Installation,Testing&Commissioningof LEDRecessed/surfaceDownlighter(Round/ square/Rectangular)SMDtypeoffollowingbody material with PMMA andprismatic diffuser and construction as per IS : 10322 with driver as per the requirementwithDriverefficiency>85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50Cto400C,internalsurge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95,IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker shouldbebelow5%), lifetime(LED,Driver& electrical circuitry), of minimum50000 Burning Hours with70% of initial Lumenmaintained till life ends,CCT 3000°K/4000°K /5700°K/ 6500°K(As per ANSI Bin),SDCM(Standard DeviationColourMatching)<3,Maximumpower consumption should not more thanthespecified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/Embossing/Screenprintingon housing Complete in all respect i/c external connections with1.5sq.mmFRLS/HFFR,PVCinsulated copper conductor single core cable and earthing etc. asrequiredwithMinimum5yearOEMwarranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test reportand all testing requiredforLEDfixturesasperBISshallbe submitted. Shape size and CCTshall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminiumhousingsuchthatLEDjunction temperature shall not rise above 90°C)Powdercoateddiecast/Extrudedaluminium Body including trim12-15 watt |
| 150 | Supplying,Installation,Testing&Commissioningof LED surface mounted Batten light of following body materialandconstructionasperIS:10322with driver(Replaceable)aspertherequirementwith Driverefficiency>85%,OperatingvoltageAC140- 270 Volt,frequency 50/60 hz, Operating temp range-5°Cto40°C,internalsurgeprotectionof2.5KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould bebelow5%),lifetime(LED,Driver&electrical circuitry),ofminimum 50000BurningHours with 70% of initial Lumen maintained till life ends,CCT 3000°K /4000°K /5700°K /6500°K(AsperANSIBin),SDCM(StandardDeviationColour Matching) <3,Maximum power consumption should not more than the specified rating and FixtureshallbeofrelevantBISstandard. Manufactures Word Mark/ Name Engraved/ Embossing/Screenprintingonhousing.complete inallrespecti/c external connectionswith1.5sq mm FRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum5yearOEMwarranty. Systemlumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Testreport andalltestingrequiredforLED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermalmanagement: heatsinkofaluminiumhousingsuchthatLED junction temperature shall not rise above 90°C).Powdercoateddiecast/Extrudedaluminium Body (Thickness > 1.20 mm)18-22 watt |
| 151 | Supply of 1200 mm , sweep 3 blade ceiling fans, suitable for 230V , 50 Hz single phase AC Supply |
| 152 | Supply of 300 mm sweep heavy duty metal body Exhaust fan with all acessories suitable for operation 230 V AC Supply 50 Hz with louvers/shutters complete with frame 300 mm Exhaust Fan 900 rpm |
| 153 | Main Distribution Panel (Normal supply )MS Sheet thickness 1.6 mmCRCA Coated dust and verminproof paintSwitchgear Make-L&T, Schneider, HavellsFloor Mounted TypeIncomer1 no 200 Amp FP mouldedCase Circuit Breaker of 35 KA(lcs value) with T/M release of O/L, S/C & E/F protection.Instruments1 no 0 to 500 volts digital volt meter (96 mm square) with selector switch.1 no 0 to 500 volts digital volt meter (96 mm square) with selector switch.I no 0 to 400 Amp digital ammeter (96 mm square) with selector switch at CT\"s.I set of energy analyser with basic parmeters like frequency, KW, KVA,KVAR, power Factor, harmonica analyser etcshall be with RS 485 port for communication and BMS compatible MODBUS output protocol.Bus Bars400 Amp TPN bus barsof aluminum alloy.2 nos 105AMp TP moulded case circuit breaker with T/M release and 35KA(LCS value) with nutural link On/off Indicating lamp. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy