| 1 | Dismantling of asbestos cement (corrugated or semi-corrugated) sheet as in roof covering complete all as specified and directed. |
| 2 | Demolition of cement concrete (un-reinforced)in ground floor and paving n. exc 15 cm thick below or above ground level & dispose off debris upto a distance n. exc. 50 mtrswhere directed complete all as specified and directed. |
| 3 | Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) complete all as specifiedand directed |
| 4 | Taking down cement plaster of any description on brickwalls, etc including raking out joints, hacking for key scrubbing down with water etc and removing of rubbish to a distance exc 50 mtr and not exe 100mtr at low lying area complete all as specified and directed. |
| 5 | S&F forPre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws as complete all as specified and directed |
| 6 | S&F For mild steel sheet 1.25 mm thickness and 150 mm dia gutter galvanised class 3 half round with rounded edges as complete all as specified and directed. |
| 7 | Plain Cement Concrete Type C 2 1:3:6 (using 40 mm gradedstone aggregate) in foundations, filling and mass concrete.Complete all as specified and directed. |
| 8 | M&L 100 mm thick Cement concrete type B 1, 1:2:4 (using 20 mm graded stone aggregate) in sub base of flooring/ hard standing finishing the surface even and fair complete all as specified and directed |
| 9 | M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound grade \"A\" for 100mm thick concrete slab.Complete all as specified and directed. |
| 10 | M&L for rendering 15 mm thick ( External surface) fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and smooth without using extracement complete all as specified and directed |
| 11 | M&L for rendering 15 mm thick (Internal surface) on fair faces of brick work or concrete surfaces on walls in CM 1:6. finishing even and smooth without using extracement complete all as specified and directed |
| 12 | M&L for prepration of newly plastered , unplastered surfaces of wall and applying two coats of cement base paint of shade as approved over a coat of cement primer complete all as specified and directed. |
| 13 | M&L for completely removing the existing treatment from wall and applying two coats of cement base paintover a coat of cement primer on wall including preparation of surfaces.complete all as specified and directed. |
| 14 | M&L for preparing newly plastered surfaces of walls and applying three coats of white wash.complete all as specified and directed. |
| 15 | M&L for preparing old surfaces of walls by brooming down or by steel wire brushing and applying one coat of white wash.complete all as specified and directed. |
| 16 | S&F for steel rolling shutters thickness of laths in 1.25mm with out ball bearing as specified including top cover anchoring rod and staple and one shop coat of primer erected in position as indicated complete but grsr operated type with chain wheel and hand chain complete all as specified and directed. |
| 17 | S&F for powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors , windows , ventilators and partition ( fixed portions ) with extruded built up standard tubular sections/ appropriate Z section and other section of approval make conforming to IS 733 and IS : 1285 fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions i.e, at top bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium section shall be smooth rust freestraight mitred and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing / paneling C.P. brass / stainless steel screws complete as per architectural drawings and the direction of Engineer - in - charge. |
| 18 | M & L for painting over steel surfaces of any description, over 10cms in width or girth not otherwise described, with one coats of synthetic enamel paint , old painted surfaces incl preparation of old painted surfaces complete all as specified and directed |
| 19 | Taking down Rolling shutter inclu complete all ass exc 15 sqm n exc 35 sqm ) complete all as specifiedand directed |
| 20 | Takingup or downsteel tubing 20 mm bore and connections, including cleaning for refixing or removal to store, complete all as specified and directed . |
| 21 | Dismantling water tanks Exc 500 Ltrs & not exceeding 2000 Ltrs and S&F rotational moulded polythene, two layers, water storage tank 1000 Ltrs capacity, closed top, cylindrical, hoisted and fixed in position including minor repairing complete all as specified and directed . |
| 22 | S & F in repair20mmbore ball brass valves high pressure with polythene float and flynut complete,Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. . |
| 23 | S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. |
| 24 | S & F 20 mm bore Galvanized Steel tubes, medium grade with all fittings forwater supply pipes etc., laid in walls and ceiling orlaid in floors . |
| 25 | M & L for painting over steel surfaces of any description, over 10cms in width or girth not otherwise described, with two coats of synthetic enamel paint , over a coat of red oxide zink chrome primer incl preparation of new or previously untreatedsurfaces complete all as specified and directed |
| 26 | S&F 110mm bore PVC (SWR) pipes single socketed Pressure rating @4Kg/Sq cmlength \"medium grade \" with rubber ring joint,laid in trenches or in floor with dash ture nut and bolt at every 2 mtrs length complete all as specified and directed by Engineer-in-charge(Make Supreme, Finolex, Prince) |
| 27 | Taking down carefully copper/aluminium point wiring from woodenbattan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc ) and making good disturbed surfaces of walls, floor etc. |
| 28 | Taking down old DBs includingexisting MCCBs and connected items of any make and type from the site and making good surface complete all as specified and directed. |
| 29 | Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. |
| 30 | Taking down old unsv light fitting,Security light , hanging light etc of any size and make from the site and making good surface complete all as specified and directed. |
| 31 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall& including stove enamelled steel conduitFRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and its also including various sizes of module plates in gray/white colour also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly complete all as specified and as directed |
| 32 | One light/fan point controlled by one way switch ( switch to be measured and paid separtely) |
| 33 | -ditto- as above item No 31.00 but copper conductor 2.5 sqmm for 15 amp socket outlet. |
| 34 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall& including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and its also including various sizes of module plates in gray colour also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly complete all as speccified and as directed |
| 35 | One light/fan point controlled by one way switch ( switch to be measured and paid separtely) |
| 36 | One 05 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 sqmm cable as earth wire connected to common earth and to earth duly socket & switches to be measure and paid separately |
| 37 | -ditto- as above item No 32.00 but Same board. |
| 38 | -ditto- as above item No 32.00 but copper conductor 2.5 sqmm for 15 amp socket outlet. |
| 39 | M & L for power point with insulated stranded copper conductor cable 4 Sqmm single coretwo run and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to earth dolly complete (socket and switches to be measured and paid separately) |
| 40 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 41 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with indicator modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 42 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 43 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 44 | Suppy & fixing MCB Protected Socket 20 Amps , PVC Plastic Base (white) with Plug top & MCB SP 20 amps complete all as specified and directed.. |
| 45 | M&L ceiling rose 3 terminal PVCpolycorbonate,isolated body complete all as directed by EIC. |
| 46 | S & F in repair LED batten luminaire surface mounted ,4 feet system wattage 20 Watts with lifetime of 50000 burning hours . CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6000 to 6500K, surge protection 2.5KV , IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker freeandincluding connecting up with PVC sheathed suitable sizecopper conductor flexible wire from ceiling rose to fitting fixed with 5 years of replacement warranty on fittings completeallas specified and directed. |
| 47 | Supply and fixing Highbay luminaire with pressure die-cast housing, integrated PC optics and 150 lm/W eficacy. 4 kV in-built and 10 kV external surge protection. IP66 ingress protection with additional safety chain 230 V AC indoor type with thermal management in multiple optics with impact and corrosion resistant complete all as directed by EIC. |
| 48 | S&F 30W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarieshould more than 110lm/W. The color temperature is 6000 to 6500 K with a color rendering index of 70. The luminaire is IP:66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision ofsuitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 49 | M & L Submain wiring with three run single core 10 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100volts grade in concealedNew PVC conduit 25 mm dia ISI marked alongwith one run of 10 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed.Note: Three runs of 10 sqmmcable and one run of PVC conduitshall be measured as one RM. |
| 50 | M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100volts grade in concealedNew PVC conduit 25mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed.Note: Two runs of 6 sqmmcable and one run of PVC conduitshall be measured as one RM. |
| 51 | Material & Labour for sub main wiring with two run of 4 sqmm size PVC insulated multi stranded copper conductor fire retardanr cable(Nominal area) and one run of4 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing cappingof required size complete all as directed by EIC. Note: Two runs of 6 sqmmcable and one run of PVC conduitshall be measured as one RM. |
| 52 | Material & Labour for sub main wiring with two run of 2.5 sqmm size PVC insulated multi stranded copper conductor fire retardanr cable(Nominal area) and one run of2.5 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing cappingof required size complete all as directed by Engr-in-charge.Note: Two runs of 6 sqmmcable and one run of PVC conduitshall be measured as one RM. |
| 53 | S & F Recess/ceiling mounting as suitable in existing fitting ultra slim 36 W LED 2x2 edge-lit tile in Aluminium Extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as specified and directed. |
| 54 | Taking down wall mounting fan any type,dismanlting blades and removing fan and blades submitted to E/M store. |
| 55 | M & L,Rewinding Exhaust/wall mounting fan of sweep 600 mm with suitable gauge copper winding wire (super enamelled)including all insulating materialafter necessary heat varnishing testing etc. complete all as specified and directed by EIC. |
| 56 | S& F wall fan (air circulating fan) complete with all accessories, 230 V,200 W, 600 mm sweep, copper winding , min air delivery 15000 CMH, with speed 1440 RPM, noise level 64 dB no abnormal noise at normal operating condition complete all as directed by EIC. |
| 57 | S &f ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep copper winding min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as directed by EIC. |
| 58 | S&F in replacement of sheet metal enclosure for VT DB TPN, MCCB DB TPN 4 way,with 200 A rated bus bar, double door with 100 Amp,25 KA,TP MCCB adjustable thermal and fixed magenetic release as incomer (Vertical type double door,100 Amps MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of Epoxy powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box with provision for 4 Pole 100 amp MCCB as incomer and SP/TP MCBs as outgoings complete all as specified and directed by EIC |
| 59 | M&L distribution board SPN8 way with 200 Amp rated bus bar double door complete all as directed by EIC |
| 60 | S & F in repair amp rating 415 V 10 KA\"B\" curve MCB TPN 63 A current currying capacity in the MCB DB complete with connection testing and commissioing complete all as specified and directed by EIC |
| 61 | S & F in repair amp rating 240V 10 KA\"B\" curve MCB SPN 32-40 A current currying capacity in the MCB DB complete with connection testing and commissioing complete all as specified and directed by EIC |
| 62 | S & F in repair amp rating 240V 10 KA\"B\" curve MCB SP 6-32 Amp current currying capacity in the MCB DB complete with connection testing and commissioing complete all as specified and directed by EIC. |
| 63 | M&L earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to galvanised earth lead wire 4 mm dialead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt with precast chamber complete, PCC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. |
| 64 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core,including GI tubing. |
| 65 | Excavation in trenches not exc 1.5m wide and not exc 1.5M depth for laying of cables,GI pipe lines etc getting out including forming bottom surfaceto required level and gradient in hard/dense soil.complete all as specified and directed. |
| 66 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm inhard/dense soil. complete all as specified and directed. |
| 67 | Removing excavated material/soil to a distance not exceeding 50mand depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. |
| 68 | M & L for sand cushioning with dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed.Note : Punned thickness only shall be measured and paid. |
| 69 | M & L Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class \"B\" laid across the cable complete all as specified. |
| 70 | M&L for road cutting/hard standing/plinth for cable laying in protection pipe with size of trench not more than requirementcomplete all as specified and directed. |
| 71 | M & L for GI Pipelight grade 40 mm dia (cable protection pipe) complete from wall, road crosing, pole etc all as directed. |