| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed |
| 2 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 3 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 4 | M&Lfor glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 5 | M&L 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 6 | Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 7 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even andrough (as in levelling course) to receive the topping layer complete all as specified and directed. |
| 8 | M & L for Vitrified Ceramictiles light shade polished (square / rectangular) of 10mm thick, area of each tilenot exc. 0.36sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed. |
| 9 | M & L for Vitrified Ceramictiles light shade polished (square / rectangular) of 7 to 8mm thick, area of each tile exceeding 0.42 sqm but not exc. 1.00sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed. |
| 10 | Demolition of brickwork built in cement or cement lime mortar including all quoins, arches pillar etc complete all as specified and directed. |
| 11 | M&L Brick work with flyash bricks, straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 12 | Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 13 | M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed. |
| 14 | M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed . |
| 15 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 16 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 17 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of wateretc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories.) (Area not exceeding 2.00 sqm) |
| 18 | Providing and fixing factory made uPVC white colour fixed or lovoured window/ ventilator made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profileOnevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick,galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories) (Area not exceeding 1 sqm each) |
| 19 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm longfasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing withselected quality glass.(Note: The unit rate quoted by contractor includes cost of glass and panel and includes all other connected accessories) |
| 20 | S & FPowder coated three track Aluminium sliding window with frame not less than 1.8 mm thick excluding aluminium grill and including 4 mm thick tinted glass, beading & necessary rubber packing, locking & opening arrangement, all fitting and fixture complete all as specified and directed. |
| 21 | S&F 7mm thick aluminium grills of make \"Decogrill\" model DG 104 surrounded by aluminium \"C\" channel with mesh size 75 X 75mm all as specified and directed. |
| 22 | S&FStainless steel wire cloth. 0.36mm nominal dia of wire and averagewidthof aperture1.40mm and fixed with stainless steel wire staples,complete all as specified and directed. |
| 23 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube in opening as per specification and shown on drg SSR Part-II 2010 ,complete all as specified and directed. |
| 24 | S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement , as per specification and shown on drawing in SSR Part-II (2010) ,complete all as specified and directed. |
| 25 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 26 | S&F Flush shutters 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed. |
| 27 | M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 28 | Taking down shutter of any description area exceeding 1 sqm but n exc 2 sqm each and removing to store complete all as specified and directed. |
| 29 | Taking down shutter of any description not exceeding 1 sqm each leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 30 | Taking down shutter of any description exceeding 1 sqmbut not exiding 2 Sqmeach leaf and refixing, in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 31 | M&L Second class hard woodplain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 32 | S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, brackets for WHB, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 33 | M&L for Cutting holes in brick walls exc half brick but not exc one brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and makinggood dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as requiredcomplete all as specified and directed. |
| 34 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. |
| 35 | S&F 100 mm long aluminium handles cast type, anodized complete all as specified and directed |
| 36 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 37 | S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 38 | S&F in repair 100 mm long aluminium anodized handles fabricated typecomplete all as specified and directed |
| 39 | S&F in repair 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. |
| 40 | S&F in repair 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 41 | S&F in repair 75 mmButt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed |
| 42 | S&Fin repair 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 43 | S&F in repairs 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 44 | Hacking out old broken glass (any thickness, size quality or description) form wooden frames or stone, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. |
| 45 | S&F 3 mm thick sheet glass ordinary quality and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 46 | S&F 3 mm thick figured glass pin headed type and gazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 47 | S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed. |
| 48 | S&F in repairs 18/19 mm thick high density PVC/ WPC solid fibre board with prelaminated PVC sheet as Kitchen cupboard and frame including taking down the old cupboard shutters and removing to store complete all as specified and directed. |
| 49 | S&F in repair 50 mmButt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type E-12 complete all as specified and directed |
| 50 | S&F continuous (piano) hinges of width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised complete all as specified and directed |
| 51 | S & F magnetic catcher catcher with nut and screw of mild steel bright finish all as specified and directed |
| 52 | S & F40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 53 | S & Fin repair40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 54 | S & F in repair hasp and stapple safety type aluminium anodised 75 mm long with mild steel hinge pin including bolt to hinge plate fixed with screw complete all as specified and directed. |
| 55 | S&F in repairs 15 mm dia Curtain rods, mild steel, chromium plated with fixing brackets complete all as specified and directed. |
| 56 | S&F in repair SS Curtain rodBracket fancy type for curtain rod 25 mm dia of any colour as approved complete all as specified and directed. |
| 57 | S&F in repairfloor door stopper of aluminium alloy body and tongue, anodised, over all length of cover plate 140 mm with hard drawn steel spring fixed in door etc complete all as specified and directed. |
| 58 | S & F in repair bevelled edge Looking mirror of any size without frame of selected quality glassmounted on wall with chromium plated stainlessscrews complete all as specified and directed |
| 59 | S&F in repairsingle door PVC cabinet mirror of size 300 mm x 450 mm with internal shelves all as specified and directed |
| 60 | S & F in repair sheetGlass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed.. |
| 61 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 15 mm bore of pipe complete all as specified and directed. |
| 62 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 20 mm bore of pipe complete all as specified and directed. |
| 63 | S&F GI tubes medium grade (ISI marked)with all fittingsfixed complete to walls, ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed. |
| 64 | S&F GI tubes medium grade (ISI marked)with all fittings fixed complete to walls, ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed. |
| 65 | Supplying and laying as in repair of CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections all as specified and directed by Engr-in-charge. |
| 66 | Supplying and laying as in repair of CPVC pipes 32mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections all as specified and directed. |
| 67 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed. |
| 68 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed. |
| 69 | S&F in repairChromoium plated Bib cock with flanges Quarter turn 15 mm bore complete all as specified and directed. Make-Jaquar , Cera & equivalent as approved by GE andEngineer in Charge. |
| 70 | Taking down bib tap /wash basin tap/pillar tap/stop cock/mixture tap and refixing the same after repair and replacement of washer only for 15 mm bore size without replacing spindles complete all as specified and directed. |
| 71 | Taking down bib tap /wash basin tap/pillar tap/stop cock/mixture tap and refixing the same after repair and replacement ofspindles for 15 mm bore size complete all as specified and directed. |
| 72 | S & F in repair Brass chromium plated wall mixer non-telephonic shower arrangement with connecting legs & wall flanges for 15 mm bore of pipe all as specified and directed.Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge. |
| 73 | S & F in repair Brass chromium platedhole bidet mixer (Basin mixer) with pop-up waste system with 300 mm long braided hoses complete all as specified and directed. Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge. |
| 74 | S & F in repair Brass chromium plated Sink mixer with raised J shaped swinging spout (Wall mounted model) with connecting legs & Wall flangescomplete all as specified and directed.Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge. |
| 75 | S&F in repairChromoium plated angular stop cock for 15 mm bore complete all as specified and directed.Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge. |
| 76 | S&F in repairChromoium platedTwo-way angular stop cock for 15 mm bore complete all as specified and directed. |
| 77 | S&F in repair, 15 mm bore stop cock, cast copper alloy with long shank and cup (concealed type) fancy type chromium plated screwed down high pressure with crutch & butterfly handle screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 78 | S&F in repair 15 mm bore stop cock, cast copper alloy screwed down high pressure with crutch & butterfly handle fancy type chromium plated screwed both ends for iron pipe and fixed complete all as specified and directed |
| 79 | S&F in repair pillar tap cast copper alloy with capstan head chromium plated crewed down high pressure with or without lettered hot or cold with long screwed sharks and ply nuts 15 mm dia complete all as specified and directed |
| 80 | S & F in repair bottle trap chromium plated for WHB as per approved quality all as per specified and directed. |
| 81 | S&F in repairPVC waste pipe for WHB etc all as specified and directed. |
| 82 | S&F in repairs 32 mm bore dia waste coupling of(min weight 32 mm-45 gm of PTMT) (half or full threaded) etc complete all as specified and directed |
| 83 | S&F in repair CP grating 100 mm dia with waste hole (minimum weight 40 gm) complete all as specified and directed |
| 84 | S & F in repair CP Jet spray for 15 mm bore all as specified and directed. |
| 85 | S & F in repairs Hand shower (Health faucet) with 1 mtr long Easy flex tube in crome finish & wall hook Make-Jaquar , Cera as approved by GE and Engineer in Charge. |
| 86 | M&L in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mmincluding supply & fixing of brass chromium plated coupling 32 mm etc complete all as specified and directed. |
| 87 | M&L in repair Wash down water closet vitreous china white pedestal pattern with \"P\" or \"S\" trap including connecting to outgoing drain pipe & to flushing pipe excluding flushing cistern and flush pipe complete all as specified and directed. |
| 88 | S&F in repairs plastic water closet seat cover, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 89 | M&L in repairs vitreous china squatting pan , ‘Orissa’ Pattern, size 580 X 440 mm white, with integral foot rests etc. complete all as specified and directed. |
| 90 | S & F in repair Kitchen sink made of stainless steel 1 mm thick with plug washer and waste pipe incl bedding fixing cantilever brackets and connetction union to pipe overall size 915 X 460mm bowl size 405X 355 mm complete all as specified and directed |
| 91 | S& F in repair 1 mm thick stainless steel plate rack of size 900X600X200 incl fixing with rawal plug and screws complete all as specified and directed. |
| 92 | S & Frotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position including dismantling of old u/s water tankand removing to storecomplete all as specified and directed |
| 93 | S & Frotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed |
| 94 | S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 95 | S&F ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 96 | S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 97 | S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 98 | S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 99 | S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 100 | S&F in repairs, PVC valveless symphonic action type low levelflushing cistern, 10 ltrs capacity with inlet, ball valve, float and handle including bracket complete all as specified and directed |
| 101 | S & F in repair internal fitting for low level flushing cistern (Syphon) complete all as specified and directed. |
| 102 | S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cistern.Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge.complete all as specified and directed. |
| 103 | S & F in repair 125 mm dia chromium plated shower rose ofwith or without swivel joint incl fixing to steel pipe complete all as specified and directed. |
| 104 | S&F in repair PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed. |
| 105 | S&F in repairs CP anodised tubular tower rail, 20 mm dia, D type, 60 cm long between flanges etc. |
| 106 | S & F in repair 75 mm PVC(SWR) floor trap with grating incl jointing with solvent cement complete all as specified and directed |
| 107 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 20 mmbore dia of pipe complete all as specified and directed. |
| 108 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for iron pipe of 25 mmbore dia of pipe complete all as specified and directed. |
| 109 | S & F in repair Soap dish any type fixed to plug with chromoium plated brass screw complete all as specified and directed. Make-Jaquar , Cera & equivalent as approved by GE and Engr-in -Charge . |
| 110 | S & F in repair corner glass shelfwith brackets complete all as specified and directed. Make-Jaquar , Cera & equivalent as approved by GE and Engr-in -Charge . |
| 111 | S & F in repair double coat hook complete all as specified and directed. Make-Jaquar , Cera & equivalent as approved by GE and Engr-in -Charge . |
| 112 | S&F in repairs door seal with aluminium beading and 50 mm wide rubber sealcomplete fixed to aluminium/ Wooden doors complete all as specified and directed. |
| 113 | M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered wall surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 114 | M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand papercomplete all as specified and directed. |
| 115 | M&L for applying 2mm thick Birla / JK Putty in two layers on old Ceiling surfaces including complete removal of existing Ceiling finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed. |
| 116 | M&L preparation of old painted surfaces and applying one coat of white wash on walls complete all as specified and as directed. |
| 117 | M&L preparation of old painted surfaces and applying one coat of white wash but on ceiling complete all as specified and as directed. |
| 118 | M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed. |
| 119 | M&L for preparation of newly plastered surfaces of ceilings and apply three coat of white wash complete all as specified and directed. |
| 120 | M&L preparation of old painted surfaces and applying one coat of oil bound distemper on walls complete all as directed. |
| 121 | M&L for Complete removal of existing treatmentand applying two coats of OBD over a coat of alkali resistant primer on wall complete all as directed by Engineer-in-Charge. |
| 122 | M&L for applying two coats of oil bound distemper on Ceiling surfaces over & includingon prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 123 | M&L for preparation of old wood or wood based surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 124 | M&L preparation of old decorated wooden painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 125 | M&L for preparation of old steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 126 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 127 | M&L applyingonr coats Cement based paint on old decorated wall surfaces,includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 128 | M&L applying two coats Cement based paint on old decorated wall surfaces,includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 129 | M & Lfor2 coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, ofrequired shade and colour ( Plastic Emulsion Paint )complete, as per manufacturer\"s specification afterPreparation of plastered surface including a coat of primer on prepared surfaces including, rubbing with sand paper and applyin complete all as specified and directed. |
| 130 | M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 131 | M&L for Rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed. |
| 132 | M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces,second layer (finishing coat)mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer\"s instructions and finish the surfaces even and smooth without using extra cement complete all as specified and directed.Note:Liquid WPC will be measured and paid separately. |
| 133 | M&L Water proofing treatment on \"Non approachable / non accessible and approachable roof\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete (i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm(ii)Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces complete all as specified and directed. (iii) Laying evenly over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction complete all as specified and directed.(iv) Applying two coats of bituminous aluminium paintincluding preparation complete all as specified and directed. |
| 134 | Taking down eaves gutters and rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. |
| 135 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed. |
| 136 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 137 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed. |
| 138 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 139 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110 mm PVC pipe complete all as specified and directed. |
| 140 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 75 mm PVC pipe complete all as specified and directed. |
| 141 | S&F PVC(SWR) bends, any radius of 110 mm bore without access door complete all as specified and directed. |
| 142 | S&F PVC(SWR) bends, any radius of 110 mm bore with access door complete all as specified and directed. |
| 143 | M/L PVC(SWR) Tee of110mm dia etc complete all as specified and directed. |
| 144 | S&F PVC(SWR) bends, any radius of 75 mm bore without access door complete all as specified and directed. |
| 145 | S&F PVC(SWR) bends, any radius of 75 mm bore with access door complete all as specified and directed. |
| 146 | S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 110 mm dia with access door complete all as specified and directed. |
| 147 | S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 75 mm dia with access door complete all as specified and directed. |
| 148 | S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 149 | S&F in repairs PVC (SWR)floor trap of diameter of outlet 75 mm, plain with gratingincluding jointing with solvent cement 75mm dia etc complete all as specified and directed. |
| 150 | S&F in repairs PVC (SWR) \"P\" trap for 110 mm dia etc complete all as specified and directed. |
| 151 | M&L for providing water proofing treatment over cleaned roof surfaces with super thermo APP modified water froofing membran comprssing of following :-(i)Removing of existing treatments including cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces/wall and filling of crack with sealing compound etc. (ii) Bitumen based primer conforming to IS 3384-1965 at 0.30 kg per sqm.(iii) One layer of super thermolay APP modified water proofing membran with non polyster reinforcement of approved Make 3mm thick and minimum weight @ 3.50 Kg/sqm laid with gas torch and fasted on roof surfaces with roller. The over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with PCC 1:2:4 type B0 with sika latex power all as per manufacturer instructions.(iv) Applying two coat of bituminous anti-corrosive multi-purpose aluminium Coating (SuperSilverShield) @ 0.15 kg/sqm per coat over bitumen layers. |
| 152 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed. |
| 153 | S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:-(a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls.(b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span).(d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling. |
| 154 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and usingbleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning,etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 155 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 500 ltr n.exc 1000 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using with bleaching powder @ 0.50 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning,etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 156 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, includingfixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 157 | S&F in repairs door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight between 36 to 60 Kg of aluminium (Die cast) body complete all as specified and directed. |
| 158 | S & F in repair Europian WC floor mounted cascade pattern vitreous china with dual core flushing cistern incl all fitting flush pipe etc make Hindware cat 92048(starwhite) or equivalent of specified make complete all as specified and directed. |
| 159 | S&F in repairs Stainless Steel Towel Rack 600 mm long with Lower Hangers but with 3 hooks.Make :- jaquar Cera & equivalent as approved by GE and AGE. |
| 160 | S & Frepair Over head Shower 100 mm round shape single flow (ABS body chrome plated with gray face plate ) with rubit cleaning system complete all as specified and directed. |
| 161 | S & F in repair chromium plated towel ring with bracket complete all as specified and directed. |
| 162 | Hacking out old broken glass (any thickness, size, quality or description)from metal frameincluding punching or drilling out old glazingpins/springclipsandprovidingand fixing new onesor stone, concrete or brick surrounds, glazed with putty or fixed with bead all as specified and directed |
| 163 | M&L 12 mm Toughned glass as in hinged doors , parttions automatic door and similar work incl cutting to shape , drilling holes required . |
| 164 | M&L in repairs for vitreous china wash basin, white,flat back, size 550 x 400 mm with pedestalincluding supply & fixing of brass chromium plated coupling 32 mm etc complete all as specified and directed. |
| 165 | S & F in repair Brass chromium plated wall mixer fancy typewith telephonic shower arrangement with connecting legs & wall flanges for 15 mm bore of pipe all as specified and directed.Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge. |
| 166 | S & F in repair Brass chromium plated fancy typehole bidet mixer (Basin mixer) with long bodypop-up waste system with 300 mm long braided hoses complete all as specified and directed. Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge. |
| 167 | S & F in repair Brass chromium plated Sink mixer with raised swan shaped shaped swinging spout (Wall mounted model) with connecting legs & Wall flangescomplete all as specified and directed.Make-Jaquar , Cera & Parrywareequivalent as approved by GE andEngineer in Charge. |
| 168 | Day to day complaints forrelated to carpenter works like door easing, door repair, kitchen cup board repair, window/door wire mesh/glass pane repair, refixing of building hardware etc by deploying carpentor and mazdoor. Note : (a) The complaints related to carpenter works, plumbing works, cement works and welding works against serial item Nos 198 to 200 shall be completed in 48 hours time after lodging/ receipt of complaints. Contractor shall ensure that all the complaints shall be attended and completed within above prescribed schedule/ time period, failing which, a penalty at the rate of double the quoted rate for that particular trade work/complaint per day till the satisfactorily completion of complaint shall be levied on the contractor and recovery for the same shall be affected from contractor\"s dues. (b)Complaint slip and complaint register etc. shall be provided by the contractor without any extra cost to the department and cost there of shall be deemed to be included in quoted rates by the contractor against respective items.(c) Necessary transportations, tools, plants, ladders, including nails, screws, PVC washers, brass spindle, for bib taps/ stop cocks/ pillar cocks, cotton thread, Jumper valves, white lead, flush washers, internal fitting of low level flushing cistern, nipple, tee, elbow, plug, socket, reducer (GI/UPVC), M-seal, glass putty, hinges, handle, tower bolt, aldrop,stopper, cement, white cement, sand other similar minor accessories required to complete the jobs/complaints shall be provided by the contractor without any extra cost to the department and cost there of shall deemed to be included in quoted rates by the contractor against respective item of schedule \"A\". |
| 169 | Day to day complaints forrelated to plumbing works like repair/refixing of Bib tap, Stop cock, Angle cock Connection pipes, waste pipes, Flush tank, Flush pipe,Shower, Pvc tank, ball valves, towel rail ,WHB,EWC, waste coupling, Grating,Pillar tap etc.by deploying plumber and mazdoor. Note : (a) The complaints related to carpenter works, plumbing works, cement works and welding works against serial item Nos 198 to 200 shall be completed in 48 hours time after lodging/ receipt of complaints. Contractor shall ensure that all the complaints shall be attended and completed within above prescribed schedule/ time period, failing which, a penalty at the rate of double the quoted rate for that particular trade work/complaint per day till the satisfactorily completion of complaint shall be levied on the contractor and recovery for the same shall be affected from contractor\"s dues. (b)Complaint slip and complaint register etc. shall be provided by the contractor without any extra cost to the department and cost there of shall be deemed to be included in quoted rates by the contractor against respective items.(c) Necessary transportations, tools, plants, ladders, including nails, screws, PVC washers, brass spindle, for bib taps/ stop cocks/ pillar cocks, cotton thread, Jumper valves, white lead, flush washers, internal fitting of low level flushing cistern, nipple, tee, elbow, plug, socket, reducer (GI/UPVC), M-seal, glass putty, hinges, handle, tower bolt, aldrop,stopper, cement, white cement, sand other similar minor accessories required to complete the jobs/complaints shall be provided by the contractor without any extra cost to the department and cost there of shall deemed to be included in quoted rates by the contractor against respective item of schedule \"A\". |
| 170 | Day to day complaints for related to cement works like repair to floors/ wall plaster in patches/ filling of holes, tiles repairs etc. by deploying mason and mazdoor.Note : (a) The complaints related to carpenter works, plumbing works, cement works and welding works against serial item Nos 198 to 200 shall be completed in 48 hours time after lodging/ receipt of complaints. Contractor shall ensure that all the complaints shall be attended and completed within above prescribed schedule/ time period, failing which, a penalty at the rate of double the quoted rate for that particular trade work/complaint per day till the satisfactorily completion of complaint shall be levied on the contractor and recovery for the same shall be affected from contractor\"s dues. (b)Complaint slip and complaint register etc. shall be provided by the contractor without any extra cost to the department and cost there of shall be deemed to be included in quoted rates by the contractor against respective items.(c) Necessary transportations, tools, plants, ladders, including nails, screws, PVC washers, brass spindle, for bib taps/ stop cocks/ pillar cocks, cotton thread, Jumper valves, white lead, flush washers, internal fitting of low level flushing cistern, nipple, tee, elbow, plug, socket, reducer (GI/UPVC), M-seal, glass putty, hinges, handle, tower bolt, aldrop,stopper, cement, white cement, sand other similar minor accessories required to complete the jobs/complaints shall be provided by the contractor without any extra cost to the department and cost there of shall deemed to be included in quoted rates by the contractor against respective item of schedule \"A\". |
| 171 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removingmaterials to store forkeeping in safe custody or for taking credit (credit for above items should be made for conditions separately )and including making good the disturbed surfaces to match with existing surface and colour shade with puttyfor smooth finishing without andulations complete all as specified and directed Note:- All old unsv credit materials should be deposited in MES yard day wise after completed of the job, the same material will beissued to contractorthrough gate passas schedule of credit against after completion of the work. |
| 172 | Material and labour for cutting chasing,pinning ofbrick/ stone/concrete wallat any height wall cutting and chases for concealedwiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 173 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed,multistranded,single core, coppercable 1100 volts grade cablesdrawn through in PVCConduit 20/25 mm dia medium grade ISI marked (MMS) at any height/places and all accessoriesare concealedinwalls / roofs / floors / ceiling etc. including suitable arrangements for flush mounting modular MS/GI boxes as per site requirement/suitable for modular top cover and framefor fixing of modular switches,sockets,fan regulators, blank plate etc andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with coppercable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directedfor One light point controlled by one 10amps switch. |
| 174 | All as per item no. 173 but for Onefan point controlled by one switch 10 amps, and oneregulator. |
| 175 | All as per item no. 173 but forOneexhaust fan point controlled by one 10 amps switch . |
| 176 | All as per item no. 173 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . |
| 177 | All as per item no. 173 but forOne 5 pin 6 amps socket point controlled by one 10 amps switch on same board . |
| 178 | All as per item no. 173 but forOne bell/buzzer point controlled by onebell push. |
| 179 | All as per item no. 173 but forOne light point controlled by two 2 way switches/bed switch point |
| 180 | All as per item no. 173 but forpoint wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm incl circuit wiring complete all as specified and directed for One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switchon independent board. |
| 181 | All as per item no. 180 but for One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on same board. |
| 182 | All as per item no. 173 but for point wiring with 4.0 sqmm and earth conductor of size 4 sqmm incl circuit wiring complete all as specified and directed. |
| 183 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed,multistranded,single core, coppercable 1100 volts grade cablesdrawn throughPVCcasing and caping 20/25 mm width double locking medium grade ISI marked (MMS) at any height and all accessories such as Tee,bend,short piece & elbow on surface on walls / roofs / floors / ceiling etc. including providing suitable arrangements for flush mounting modular MS boxes as per site requirement/suitable for modular top cover and framefor fixing of modular switches,sockets,fan regulators, blank plate etc andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with coppercable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directedfor One light point controlled by on switch |
| 184 | All as per item no. 183 but forOnefan point controlled by one switch and regulator |
| 185 | All as per item no. 183 but for One exhaust fan point controlled by one switch. |
| 186 | All as per item no. 183 but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 187 | All as per item no. 183 but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 188 | All as per item no. 183 but for One bell point controlled by one bell push. |
| 189 | All as per item no. 183 but forOne light point controlled by two 2 way switches. |
| 190 | All as per item no. 183 but forpoint wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm and incl providing circuit wiring complete all as specified and directed for One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switchon independent board. |
| 191 | All as per item no. 183 but for One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board. |
| 192 | All as per item no. 183 but for point wiring with 4.0 sqmm and earth conductor of size 4 sqmm incl providing circuit wiring complete all as specified and directed. |
| 193 | Supply & fixing and fixing in repairs modular type switch 10 Amps, single pole,1way,1 module,240V,AC,ISI Markedcomplete all as specified and directed. |
| 194 | Supply & fixing and fixing in repairs modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, ISI Markedcomplete all as specified and directed. |
| 195 | Supply & fixing and fixing in repairs modular type bell push 6 Amps,1 module, single pole, 240 volts,AC,ISI Marked complete all as specified and directed. |
| 196 | Supply & fixing and fixing in repairs modular type switch 16 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed. |
| 197 | Supply & fixing and fixing in repairs modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,ACISI Marked complete all as specified and directed. |
| 198 | Supply & fixing and fixing in repairs modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module,240V,ACISI Markedcomplete all as specified and directed |
| 199 | Supply & fixing and fixing in repairs red color lighting indication lamp 6 Amps, single pole,240volts,AC,50 Hz suitable for 1 moduleISI Marked complete all as specified and directed. |
| 200 | Supply & fixing and fixing in repairs modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 0 to 4/5 steps,ISI Markedcomplete all as specified and directed. |
| 201 | Supply & fixing and fixing in repairs call bell AC, 230 Volts single pole, multi music typeISI marked, complete all as specified and directed. |
| 202 | Supply & fixing and fixing in repairs call bellding dong AC, 230 Volts single pole, multi music typeISI marked, complete all as specified and directed. |
| 203 | Supply & fixing and fixing in repairs angle lamp holder, insulated body with back plate for batten fittingscomplete all asspecified and directed. |
| 204 | Supply & fixing and fixing in repairs ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed. |
| 205 | Supply and fixing, in repairs 20 watt LED pride plus NXT batten white decorative type,high quality materials,240V,50Hz, and slim integrated body,easy to install,PC diffuser and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. |
| 206 | Supply and fixing, in repairs 40 watt LED pride plus NXT batten, warm light decorative type,high quality materials,warm or white colour, ,240V,50Hz, and slim integrated body,easy to install,125 lm/w,PC diffuser and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. |
| 207 | Supply and fixing, in repairs20 watt LED batten nicolaus glamtube dual or tricolour integrated design, easy to install,efficency,125 lm/w,PC diffuser and robust housing, high quality materials,pre-wired and connect with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. |
| 208 | Supply and fixing , in repairs 36 wattsLED supernovalight fitting high wattage complete,energy efficient, Warm /White colour,integrated design, easy to install,PC diffuser, high quality materials,pre-wired incl connect with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed |
| 209 | Supply &fixing, in repairs 40 watt LED light fitting in tricolor or duallighting warm/light white/milk white lighting, high quality materials and intergrated design, PC diffuser, warm or white colour,reliable and robust housing structure, easy to install, efficency 125 lm/wnecessary arrangements for fixing with LED fitting to ceiling rosecomplete all as specified and directed. |
| 210 | Supply & fixing , in repairs 20 watts LEDAustra mirror light fitting,contemporary designdecorative LED lighting with extruded polycarbonate, environmentalfriendly, energy efficient, easy to install,PC diffuser, high quality materials,pre-wired incl connect with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. |
| 211 | Supply & fixing, in repairs glaze model type wall mountinglight fitting 9 watt and incl LED lamp(White/Warm) decorative type,in durable plastic body & designer mesh in gold finish incl connect with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed . |
| 212 | Supply & fixing , in repairs floret model type wall mountinglight 9 watt and incl LED lamp(White/Warm) decorative type,in durable plastic body & designe incl connect with LED fitting to ceiling rose and incl removing old unserviceable fitting complete all as specified and directed . |
| 213 | Supply & fixing, in repairs sana model type wall mountinglight 9 watt and incl LED lamp(White/Warm) decorative type,in durable plastic body & designe incl connect with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed . |
| 214 | Supply & fixing, in repairs city-2 model type wall mountinglight 9 watt and incl LED lamp(White/Warm) decorative type,in durable plastic body & designeincl connect with LED fitting to ceiling roseand incl removing old unserviceable fitting complete all as specified and directed . |
| 215 | Supply & fixing, in repairscity-3 model type wall mountinglight 9 watt and incl LED lamp(White/Warm) decorative type,in durable plastic body & designe incl connect with LED fitting to ceiling rose and incl removing old unserviceable fitting complete all as specified and directed |
| 216 | Supply &fixing , in repairs globe model type wall mountinglight 9 watt and incl LED lamp(White/Warm)decorative type,in durable plastic body & designe incl connect with LED fitting to ceiling roseand incl removing old unserviceable fitting complete all as specified and directed . |
| 217 | Supply &fixing , in repairs SS housing model type wall bracket light 9 watt and incl LED lamp(White/Warm)decorative type,in durable plastic body & designe incl connect with LED fitting to ceiling roseand incl removing old unserviceable fitting complete all as specified and directed . |
| 218 | Supply &fixing , in repairs energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired ofluminaires including LED light driver and connected with LED fitting to ceiling rose terminaland incl removing old unserviceable fitting complete all as specified and directed. |
| 219 | Supply &fixing , in repairs LEDbldg secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionand including removing of old unserviceable item complete all as specified and directed. |
| 220 | Supply and fix GI bracket pipe of size 25 to 32 mm diaas suitable medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirementwith hot or coldbending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixedonwall surfaces and including providingsuitable fabricate galvanised flat ironclamps of 20X4 mm thick-02 Nossuitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed |
| 221 | Supply &fixing , in repairs 60-70 Watt LED fitting energy saving,environmental friendly,long lifewith SMD LEDs aslight source with driver included, light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. |
| 222 | Supply &fixing , in repairs in sheet metal enclosurewith DD type,415 volts AC,TPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection and includingremoving old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 223 | Supply &fixing , in repairs in sheet metal enclosure double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection and includingremoving old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed.. |
| 224 | Supply &fixing , in repairssheet metal enclosure, , double door, 240 volts AC,SPN,DB, 16 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 225 | Supply &fixing , in repairssheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 12 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 226 | Supply & fixing in repairssheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 227 | Supply & fix andfixing in repairs andsheet metal enclosure, D/D, 240 volts AC,SPN,DB, 4 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP,and MCB SP as outgoingforIP 43& IP54 DBs protection nd includingremoving old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 228 | Supply & fix andfixing in repairs mini MCB,32 A,DP \"C and motor starter with socket including with suitable sunken box in concealed/surface and internally connected properly suitable for cooking electrical appliancesincluding protection and includingremoving old unserviceable items and making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 229 | Supply & fix andfixing in repairsMCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed. |
| 230 | Supply & fix andfixing in repairsMCB SPN 32 to40 Amps 10 KA,\"C\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 231 | Supply & fix andfixing in repairsMCB SPN 40 to63 Amps 10 KA,\"C\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 232 | M & L for sub main wiring complete in repairs with 2 run of 10 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn drawnthroughand including PVC conduit in concealed ISI marked medium grade(MMS) accessories such as Tee,corner, overlaping connector etcand including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 233 | M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 4.0 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 234 | M & L for sub main wiring complete with 2 run of 1.5 sqmm single core copper conductor (ISI marked)cable1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 1.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 1.5 sqmm single core copper conductor cable and one run of 1.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 235 | Supply & fix andfixing in repairs suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20Amps, 10KA \"C \"series, 230 Volts,50Hzsuitable for AC\"s/Geysers complete all as specified and directed. |
| 236 | Supply & fix andfixing in repairsMCCB,125 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washersand including removing old unserviceable itemcomplete all as specified and as directed. |
| 237 | Taking down old unsv ceiling fan from existing location and supply and fix ceiling fan with blades, down rods, and connected accessories, 230 V, 1200 mm sweep, with squirrel cage induction motor, anti dust painted, dust free,high speed. Star ratedcomplete all as specified and directed. |
| 238 | Taking down old unsv exhaust fan from existing location and supply and fix new exhaust fan, steel body AC single phase.230Volts of size 300 mm sweep with blades and frame with louvers complete all as specified and directed. |
| 239 | Taking down old unsv exhaust fan from existing location andsupply and fix new exhaust fan, steel body AC single phase.230Volts of size 150 mm sweep with blades and frame with louvers complete all as specified and directed. |
| 240 | Taking down old unsv exhaust fan from existing location andsupply and fix new exhaust fan, steel body AC single phase.230Volts of size 200 mm sweep with blades and frame with louvers complete all as specified and directed. |
| 241 | Taking down old unsv exhaust fan from existing location andsupply and fix new exhaust fan, steel body AC single phase.230Volts of size 250 mm sweep with blades and frame with louvers complete all as specified and directed. |
| 242 | Taking down old unsv exhaust fan from existing location andsupply and fixing newexhaust fan made of sturd engineering plastic complete with louvers shutters, voltage 230v,50hz,rpm 1200 copper winding of sweep 250 mm complete all as specified and directed. |
| 243 | Taking down old unsv exhaust fan from existing location andsupply and fixing newexhaust fan made of sturd engineering plastic complete with louvers shutters, voltage 230v,50hz,rpm 1200 copper winding of sweep 200 mm complete all as specified and directed. |
| 244 | Taking down old unsv wall fan from existing location and supply and fixing wall fan 450 mm sweep, 50 watts with double string, low noise, air delivery 70CMM, RPM-1320, overload thermal protector, 240 volts, 50 Hz complete all as specirfied and directed. |
| 245 | Taking down old unserviceable geyses of any capacity from work site at any height and deposit to MES store yard for safe custodyand Supply and fix new electric water heater, storage type steel body/plastic body with copper inner tank and heating element upto2 KW capacity 25 litres, BEE 5 star rated complete with all accessories such as safety valve,thermostat, NRV, Hot waterand Cold waterheavy duty connection pipes-02 Nos,holefasterns-04 Nosand necessary accessories as per site requirement etc.complete all as specified and directed. |
| 246 | Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron strip of size 32 X 6 mmfrom earth electrodeto test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value completeall as specified and directed. |
| 247 | S&F for PVC non-metalic rigid conduit incl boxes,junctions boxes 1 to 4 way & terminals but incl of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers lock nuts,saddles,pipes hookes etc ISI marked heavy duty of size 20/25 mm dia for LAN,telephone and TV connections cablesincluding cutting,chasses and making good disturbed surfaces to match with existing surfaces with plaster/putty and including removing of old unserviceable item complete all as specified and directed. |
| 248 | Cutting the existing surface wall of brick/stone masonary and making round hole at any height suitable for fixing 200 to 450 mm sweep exhaust fan including providingnut,bolt and washers after grouting in PCC and including 3 mm dia 5 cm apreature size GI jali and properaluminium frameto avoid insect protection fix at inner surface of wall andmaking good the disturbed surface area complete all as specified and directed. |
| 249 | Supply and fixing TVsockets one module with top cover plate and inner frameincluding all necessary accessories and including removing of old unserviceable item complete all as specified and directed. |
| 250 | Supply & fix andfixing in repairs Telephone socket(RJ11) one module with top cover plate and inner frameincluding all necessary accessories and including removing of old unserviceable item complete all as specified and directed. |
| 251 | Supply & fix andfixing in repairscopper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade 3 core ;2.5 sqmm and including electric connection through PVC conduit in concealed/casing caping in surface from ceiling fan to ceiling roseand including removing old unserviceable item complete all as specified and directed. |
| 252 | Supply & fix andfixing in repairs neo LED strips 24 watt 6000k ,240Volts ,standard length ,single phase with uniform light distribution and long lasting adhesive for perfect cove light,colour as per required andincluding all connected accessories suitable for proper fixing as per site requirement and removing old unserviceable fitting complete all as specified and directed. |
| 253 | Supply & fix andfixing in repairs LED wall mounted bldg secruity light fitting of capacity 35 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection and including removing of old unserviceable item complete all as specified and directed. |
| 254 | Supply & fix andfixing in repairs20 watts LED post top lantern made in cast aluminium spigot housing with decorative opal polycarbonate diffser and IP65 protectionand providing suitable fixing arrangements such as necessary GI pipe at post top/pillar and civil work, lugs,glands,nuts,bolts and washers andincluding removing old unserviceable itemcomplete all as specified and directed. |
| 255 | Supply & fix andfixing in repairs 40 watts LED post top lantern made in cast aluminium spigot housing with decorative opal polycarbonate diffser and IP65 protectionand providing suitable fixing arrangements such as necessary GI pipe at post top/pillar and civil work, lugs,glands,nuts,bolts and washers andincluding removing old unserviceable itemcomplete all as specified and directed. |
| 256 | Supply & fix andfixing in repairs LED flood light light fitting of capacity 170 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP-65 protection and including removing of old unserviceable item complete all as specified and directed. |
| 257 | Supply & fix andfixing in repairs LED flood light light fitting of capacity 120 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP-65 protection and including removing of old unserviceable item complete all as specified and directed. |
| 258 | Supply & fix andfixing in repairs LED flood light light fitting of capacity 100 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP-65 protection and including removing of old unserviceable item complete all as specified and directed. |
| 259 | Supply & fix andfixing in repairs LED flood light light fitting of capacity 70 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP65 protection and including removing of old unserviceable item complete all as specified and directed. |
| 260 | Supply and fixing and in repairsgalvanised metal flush box 1/2 module,ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 261 | All as per item No-260 but formetal box 3 module |
| 262 | All as per item No-260 but formetal box 4/5 module |
| 263 | All as per item No-260 but formetal box 6 module |
| 264 | All as per item No-260 but formetal box 8/9 module |
| 265 | All as per item No-260 but formetal box 12 module |
| 266 | All as per item No-260 but formetal box 16 module |
| 267 | All as per item No-260 but formetalbox 18 module |
| 268 | Supply and fixing in repairs modular white/wood/glazed type cover plate with frame 1 module,ISI marked and suitable for existing type as per site requirement and incl screws,washears etc and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 269 | All as per item No-268 but for modular white/wood/glazed type cover plate with frame 2 module |
| 270 | All as per item No-268 but formodular white/wood/glazed type cover plate with frame3 module |
| 271 | All as per item No-268 but formodular white/wood/glazed type cover plate with frame4/5 module |
| 272 | All as per item No-268 but for modular white/wood/glazed type cover plate with frame6 module |
| 273 | All as per item No-268 but formodular white/wood/glazed type cover plate with frame8/9 module |
| 274 | All as per item No-268 but formodular white/wood/glazed type cover plate with frame12 module |
| 275 | All as per item No-268 but formodular white/wood/glazed type cover plate with frame 16 module |
| 276 | All as pAll as per item No-268 but for modular white/wood/glazed type cover plate with frame18 module |
| 277 | Supply and fixing in repairs 2.5 mfd capacitor,240volts, 50Hz and including removing old unserviceable item complete all as specified and directed. |
| 278 | Taking down and Hanging only ceiling fan, wall fans after cleaning and connecting up including provision of cable from ceiling rose/switch socket or connector to fan and including providing necessary accessoriescomplete all as specified and as directed. |
| 279 | Taking down and fitting only exhaust fanafter cleaning and connecting up including provision of cable from ceiling rose or connector to fan and including providing necessary accessoriescomplete all as specified and as directed. |
| 280 | Fixing only and connecting electric meters 10-60 Amps any type single or three phase complete all as specified and directed and including providing necessary accessoriescomplete all as specified and as directed. |
| 281 | Taking down carefully existing electric meters of any type/capacity from work site and deposit to MES store yard/ Charge holder without damage for safe custody and supply and fixingsingle phase electronic meters temper proof LCD display with polycarbonate cover 230Volts,10-60 Amps, accuracy class-I,50Hz, confirming to IS-13779,IP-54,with parameters to show data,time current reading,load,PF,voltage and KWH including connected necessary items for functioning complete all as specified and directed. |
| 282 | Taking down carefully existing electric meters of any type/capacity from work site and deposit to MES store yard/ Charge holder without damage for safe custody and Supply only three phaseelectronic meters temper proof LCD display with polycarbonate cover 415Volts,10-60 Amps, accuracy class-I,50Hz, confirming to IS-13779,IP-54,with parameters to show data,time current reading,load,PF,voltage and KWH including connected necessary items for functioning complete all as specified and directed. |
| 283 | Supply and fixing copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade 3 core ;0.75/1.0 sqmm and including electric connection from ceiling fan to ceiling roseand including removing old unserviceable item complete all as specified and directed. |
| 284 | Supply and fix in repairs of PVC round cover blanking plate as per site requirement with screws of existing fan junctions/ wiring junctions boxes etc |
| 285 | Supply and fixing 1 or 2 module fan regulator piano switch type/socket type as per site requirement, electronic, stepped type, 100/120 Watts,240Volts,AC,ISI marked complete all as specified and directed. |
| 286 | Supply and fixingswitch piano type, 6 Amps, flush mounted,1 way, 240 volts,ISI markedand including removing old unserviceable item complete all as specified and directed. |
| 287 | Supply and fixing bell push6 Amps,240 volts, ISI marked and including removing old unserviceable item complete all as specified and directed. |
| 288 | Supply and fixingswitch socket outlet6Amps,5 pin,flush type 240 volts,ISI marked and including removing old unserviceable item complete all as specified and directed. |
| 289 | Supply and fixing switch socket combination 6Amps,5 pin, flush type 240 volts,ISI marked and including removing old unserviceable item complete all as specified and directed. |
| 290 | Supply and fixing switch socket combination 6/16Amps,6pin 240 volts withneon indicator type,ISI markedand including removing old unserviceable item complete all as specified and directed. |
| 291 | Supply and fixing switch socket combination 6/16Amps,6pin ,240 volts,ISI marked and including removing old unserviceable item complete all as specified and directed. |
| 292 | Supply and fixing junction boxe topplastic round cover,four terminals and including removing old unserviceable item complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail