| 1 | Dismantlingof plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed by Engr-in-charge. |
| 2 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and directed. ( zinc coating 275) |
| 3 | S& f Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts or screws complete all as specified and directed |
| 4 | All as per item No 3 but plain sheets as in riges and roof covering,eaves gutter all as specified and directed |
| 5 | S&F Plain, Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as spd and as drected by Engr-in-Charge |
| 6 | M &L for False ceiling of 4 mm thick non asbestos tiles (600x600mm grid)fixed usingGl frame work for seamlessceiling comprising of Glperimeter channnel 0.55 mmthick with two unequal flangesof 20 and 30 mm and web of27 mm fixed to surroundingwall using nylon sleeves andscrews at 450 mm centre tocentre/intermediate channel0.9 mm thick having two equalflanges of 15 mm each and webof 45 mm suspended fromsoffit at approx 900 mm centreto centre with Gl cleat andsteel expansion fasteners withand including ceiling sectionof 0.55mm thickness having kurledweb of 50 mm and flange of26 mm each with lips of 10.5mm fixed to the intermediatechannel with connecting clipsacross the intermediatechannel at 457 mm centre tocentre.Hangers 6 mm dia. G.I. (upto1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm longincluding taking down existing ceiling board & grid work etc of any type/pattern complete all as specified |
| 7 | S&F 600 x 450mm bevelled edge mirror of selected quality glass 5mm tyhick polished mounted on 6mm thick AC building board fixed to wallsin repairall as spd and directed |
| 8 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed. |
| 9 | M&L for Rendering 15 mm thick in two layers (10+5) on fair facesor other than fair faces of brick work, concrete sruface,stone masonaryin cement mortar (1:6), finished even and smooth without using extra cement completeincluding taking down cement plasteron brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises all as specified and directed by engr-in-charge.Note: Necessary additional dubbingif required will be done by contractor and nothing extra cost is admissible in this account.all as specified and directed. |
| 10 | M&L for Rendering 15 mm thick in two layers (10+5) on other than fair faces of brick work,stone masonary surface, concrete surface in cement mortar (1:4), finished even and smooth without using extra cement complete including taking down cement plasteron brick walls or stone walls of any description etc all as specified and directed by engr-in-charge.Note: Necessary additional dubbingif required will be done by contractor and nothing extra cost is admissible in this account. |
| 11 | M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and directed. |
| 12 | M&L forpreparing new plastered surface of walland appying two coat of cement base paint mixed with silicon based water repellent compound over a coat of primer by roller/brushcomplete all as specified & as directed by Engineer-in-Charge. |
| 13 | M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed. |
| 14 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, rubbish off the premises complete all as specified and directed |
| 15 | Cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair incl making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified |
| 16 | M&L forPCC 1:2:4 Type B1 (using 20 mm graded crushedstone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , fillet, gola, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 17 | M & L clean sawn second class soft-wood in frame work scantlings or frame work for false ceiling including dismantling all as specified and directed |
| 18 | M & L clean sawn 20 mm thick with butt jointsecond class soft wood boarding, supplied & fixed with nails in any situation (except flooring and skirting) including dismantling all as specified. |
| 19 | Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil all as specified and directed by engr-in-charge |
| 20 | M & L 4 mm thick non asbestos cement plain building boards, fixed to timber framework with nails or screws including dismantling of board fixed in repair all as specified and directed |
| 21 | M & L second class soft wood exc 3sqcm not exc 6sqcm Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or screws and painting two coat of synthetic enamel paint over a coat of pink primer in repair including dismantling all as specified and directed |
| 22 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches,pillars, etc, in any situation all as specified and directed |
| 23 | M & l for brick work with sub class\"B\" bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6)all as spd and directed |
| 24 | All as per item no 23 above but except stone or brick built in CM (1:6)all as spd and directed |