| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | By Mannual Means |
| 3 | Carriage of materials ie Earth, Sand, Lime, Morrum manure or sludge From site including stacking, loading and unloading etc complete with all lead and lift.( For 5 Km) |
| 4 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). |
| 5 | Providing and Laying of Interlocking M-30 grade Concrete Block Pavements having thickness 60 mm as per drawings and as per IS 15658:2006.and materials conforming to MoRTH Specification Clause 602 with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks. |
| 6 | Category \"A\" : Dentated units to key into each other on all four faces Zigzag shape as per IRC:SP:63-2004 |
| 7 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: |
| 8 | Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 9 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : |
| 10 | Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 11 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRTH specification Clauses 1313, 1411 and 2206.6 |
| 12 | 50 mm thick |
| 13 | Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : |
| 14 | Flush / Ruled/ Struck or weathered pointing. |
| 15 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 16 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 17 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 |
| 18 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 19 | Plaster on new surface on walls in cement sand mortar 1:6including racking of joints etc. complete fine finish : |
| 20 | 12mm thick . |
| 21 | Plaster on new surface on walls in cement sand mortar 1:6including racking of joints etc. complete fine finish : |
| 22 | 20mm thick . |
| 23 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 24 | New Plastered Surface (three or more coats) |
| 25 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 26 | Old Plastered Surface (two or more coats) |
| 27 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 28 | Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 29 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 30 | Old work (One or more coats ) |
| 31 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : |
| 32 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 33 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) |
| 34 | Cold twisted deformed bars (IS : 1786)./ Hot rolled deformed bars (IS : 1139). |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 36 | One or more coats on old work. |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 38 | Two or more coats on new work |
| 39 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 40 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 41 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 42 | Steel work in built up tubular trusses including cutting, hoisting (height upto 10 m)fixing in position and applying a priming cout of approved steel primer, welded and bolted including special shaped washers ete. complete. |
| 43 | Hot finished welded type tubes. |
| 44 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 45 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 46 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 47 | M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 48 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 49 | Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughout in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: |
| 50 | Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointing with cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : |
| 51 | Fine dressed & machine cut edges 30-35 mm thicksand stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI. |
| 52 | Pink sand stone (Bansi Paharpur stone) |
| 53 | P & F Stone cladding/Flooring works dressed bansi paharpur stone 25mm thick in traditional style used in cladding/Flooring with pattern over 25 to 50 mm thick base in CM 1:6 including pointing with cement mortar 1:2 (cement : 2 stone dust) matche the shade of stone with joint thickness upto 1.5mm as per direction of engineer-in-charge. |
| 54 | Single piece of stone element with carving work in Bansi Paharpur stone includes stone pillar, stone base, todies and thabi etc carving work as per direction of engineer in charge |
| 55 | Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10 m height with 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be securedto the backing by means of cramps which shall be paid separately) Exposed face Machine cut |
| 56 | Providing and fixing of Bansi Paharpur stone Dasa (size 150×300mm) carving as per approved design& drawing and direction of engineer-in-charge |
| 57 | Providing and fixing expansion hold fastenrs on C.C/R.C.C. surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 6 MM |
| 58 | Grinding of existing floor with |
| 59 | 60, 80, 120 and 360 No. Carborundum stone including cost of wax polishing complete : |
| 60 | Add extra for mirror polishing on existing marble work/ Kota stone flooring work where ever required to give high gloss finish complete. |
| 61 | Repair of rolling shutter with replacement of shutter spring incl. removal of old spring in the existing rolling shutter incld. Cost of new spring |
| 62 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design |
| 63 | 500 (-do-) for toilet |
| 64 | Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 801.3.1, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and MoRTH Specification Clause 801 |
| 65 | 600 mm x 600 mm square |
| 66 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to code IS : 15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 67 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to code IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 68 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 69 | South (Red) for toilet HE & SHE & TICKET COUNTER |
| 70 | 1501 Cm2 to 3600 Cm2 Tiles |
| 71 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 72 | Granite/Kota Stone Work |
| 73 | Half Edge moulding |
| 74 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 75 | For area of each slab from 2001 to 5000 Sq.Cm |
| 76 | Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 77 | Grade 304 |
| 78 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). |
| 79 | For fixed portion |
| 80 | Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 81 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). |
| 82 | Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 83 | Add Extra for shutters of sliding aluminum windows |
| 84 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) |
| 85 | With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835. |
| 86 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. |
| 87 | Prelaminated particle board with decorative lamination on both sides. |
| 88 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. |
| 89 | Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 90 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 91 | Providing and Fixing corrugated colour G.I sheet having thickness 0.50mm roofing fixed with G.I.J or L Hooks bolts and nuts 8mm dia meetr with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect. |
| 92 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: |
| 93 | New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 94 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision |
| 95 | New Work |
| 96 | Old Work |
| 97 | P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. |
| 98 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: |
| 99 | Size 580x440mm. |
| 100 | P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. |
| 101 | Flat Back (large) or half stall size 610x400x80mm. |
| 102 | P & F Flush Pipe of approved make with complete fittings for high level flushing cistern: |
| 103 | G.I. `B` class (Concealed) 25mm. |
| 104 | G.I. `B` class (Concealed) 32 mm. |
| 105 | P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make. |
| 106 | For 1 Urinal |
| 107 | P & F C.P. brass Doom Waste Coupling 40 mm dia. |
| 108 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : |
| 109 | Size 580 mm x 450 mm |
| 110 | P & F Extension Pipe for bib cocks of approved quality/make. |
| 111 | C.P. brass of Heavy & Superior quality 50x15mm(-do-) 150 X 15mm. |
| 112 | P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. |
| 113 | Providing & fixing C.P.flange for 15mm dia taps. |
| 114 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. |
| 115 | 110 mm dia |
| 116 | 160 mm dia |
| 117 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 118 | Coupler (socket) |
| 119 | 110mm dia |
| 120 | 160 mm dia |
| 121 | Reducer 110 X 75 mm |
| 122 | 75mm dia |
| 123 | 110mm dia |
| 124 | 160 mm dia |
| 125 | Plain Tee |
| 126 | 75mm dia |
| 127 | 110mm dia |
| 128 | 160 mm dia |
| 129 | Bend 45 |
| 130 | 75mm dia |
| 131 | 110mm dia |
| 132 | 160 mm dia |
| 133 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) |
| 134 | 20mm nominal size |
| 135 | 25 mm nominal size |
| 136 | Providing and fixing premium quality Angular stop cock 15mm with wall flange complete as per sample approved by Engineer in charge |
| 137 | Providing and fixing premium quality Two way Bib cock 15mm with wall flange complete as per sample approved by Engineer in charge |
| 138 | Providing and fixing 3-layer PP-R (Polypropylene random coplymer ) pipes SDR 7.4 UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings including trenching, refilling and testing of joint complete as per direction of Engineer - in charge. (EXTERNAL WORKS) |
| 139 | P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. |
| 140 | Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble. |
| 141 | P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor: |
| 142 | Size 450x350mm |
| 143 | P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make: |
| 144 | C.P. Pillar cock Elbow action, 15 mm nominal bore. |
| 145 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: |
| 146 | P.V.C.heavy duty, 15mm nominal bore. |
| 147 | C.P. Brass bib cock,15mm nominal bore. |
| 148 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: |
| 149 | C.P. Brass 15mm nominal bore. |
| 150 | P & F 15 mm. Dia Connection Pipe of approved quality/make : |
| 151 | (-do-) 450mm. |
| 152 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : |
| 153 | Gun-metal 15mm nominal bore. |
| 154 | Providing and fixing calcium silicate board false ceiling at all heights including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the calcium silicate board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting of thickness of calcium silicate board as below:- |
| 155 | 8 mm thick |
| 156 | Providing and fixing Mandana Cobble Stone flooring work dressed stone 100mm thick in hound finished with pattern as per approved design over 25-50mm thick base in CM 1:6 incl. pointing with cement sand mortar 1:2 (1 Cement:2 sand)match the shade of stone with joint complete in all respect as per direction of engineer-in-charge & Architect with all lead & lift. |
| 157 | Providing and fixing combination stone flooring for pathways having both edges of border 40-50 mm black Kadappa stone of size 825 mm x 400 mm, laid in 20mm thick cement mortar 1:4 as per approved Drawing including centre part of path having shahbad brown antique finish of size 400 mm x 400 mm & in centre longitudinal every fourth stone of black kadappa of size 400 mm x 400 mm having fine finish jointing with white cement using pigments to match the stone shade etc. complete in all respect as per drawing design & specifications and as per direction of Engineer-in-charge & Architect with all lead & lift. Thickness of stone 40-50mm. |
| 158 | Renewing glass panes and refixing existing wooden fillets : |
| 159 | 4mm thick plain glass panes. |
| 160 | Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase and making good and painting exposed portion of the clamps complete. Please Enable Macros to View BoQ information |