| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.For thickness of tiles 10 mm to 25 mm |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 4 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:In cement mortar |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 meters lead : Of area of 3 sqm. and below |
| 6 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) including all lifts,leads,carriage of the material. |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cementand matching pigments etc. complete.Size of tile 600x600 mm |
| 9 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thicknessto be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 10 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes reparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 11 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 12 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (18mm Thick) |
| 13 | Providing edge moulding to 18 mm marble stone /granite stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge (Granite Work) Double moulding |
| 14 | Providing and fixing Lockable sliding Atdrop 250-300mm long of approved quality (Godrej/ Link/Ramson or equivalent) with necessary screws etc. complete. |
| 15 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand).including all lifts,leads,carriage of the material. Complete job |
| 16 | Renewing glass panes, with wooden fillets wherever necessary : Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) |
| 17 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. |
| 18 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m Sq. on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size |
| 20 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 21 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 22 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations: footings, bases of columns etc. for mass concrete. |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 25 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position including welding etc and applying a priming coat of approved steel primer all complete. Including welding and bolt cost |
| 26 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including all lifts,leads and carriages complete job |
| 27 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work. |
| 28 | Finishing walls with Acrylic smooth exterior paint of required shade: Old work (two or more coats applied @ 1.67 liters/10sqm on existing cement paint surface) |
| 29 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 30 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick |
| 31 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 33 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood |
| 34 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 35 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws(35mm Thick) |
| 36 | Extra for providing and fixing flush doors with decorative veneering instead of non-decorative ISI marked flush door shutters conforming to ISI: 2202 (Part-I) On one side only |
| 37 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 38 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 150x10 mm |
| 39 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.125 mm |
| 40 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 41 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:18.2.1 W.C. pan with ISI marked white solid plastic seat and lid. |
| 42 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereverrequired:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mmCP Brass single hole basin mixer |
| 43 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 44 | Providing and fixing of PVC connection for wash basins, geysers etc. |
| 45 | Providing and fixing toilet paper holder :CP Brass |
| 46 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 47 | Providing and fixing of Health Faucet / jet spray with plastic flexible pipe 8 mm dia, 1.5 m long, wall hooked complete as required, including necessary Accessories ,installation charges and complete in full respect as per the directions of Engineerin- charge. |
| 48 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 49 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 50 | Providing and fixing of water heater (geysers) (Havells/ Hindware/ Jaquar/ Venus or equivalent) including cost of dash fastenerc with nuts and washers 50 LTRS |
| 51 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 52 | Providing and fixing of \"15mm size chromium plated cast brass wall / Sink mixer with bend pipe for head shower of approved quality. (Hindware/ Jaquar/ Kerrovit/ Asian/ Marc or equivalent) with flange quality & make as approved by Engineer in charge (including bend, Shower, arm etc) |
| 53 | Providing and fixing UV stabilised UPVC pipes, Type B as per IS:13592 for soil, waste, rain water and vent, including all fittings with or without access i.e Clean out plug, bends, junctions, cowls, offsets, couplers, connectors, heavy duty Metal pipe clamps with rubber seal/clips//holders etc. and jointing with heavy duty solvent cement, complete as per manufacturer\"s specifications and making good the same, complete as directed by the Engineer-in-Charge. (vertical pipes can be jointed through rubber O rings) |
| 54 | 50mm outer dia. |
| 55 | 75mm outer dia. |
| 56 | 110mm outer dia. |
| 57 | 160mm outer dia. |
| 58 | Providing and fixing multi inlet uPVC floor trap with minimum 50mm water seal of self cleaning design with 110 mm outlet consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc, complete including cost of cutting and making good the walls and floors wherever required and as directed by Engineer in charge. (The inlet diameter shall be 32mm, 40mm or 50mm as per site requirements) |
| 59 | Providing and fixing SS grating with frame including fixing to the floor with cement mortar.100mm dia |
| 60 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 61 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 62 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 63 | Internal work-exposed on wall with clamps at 1.00 meterspacing |
| 64 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 65 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 66 | PN-16 pipe , 40mm OD(SDR-7.4) |
| 67 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 68 | 15 mm nominal bore |
| 69 | 20 mm nominal bore |
| 70 | 25 mm nominal bore |
| 71 | Providing and fixing PPR Unions |
| 72 | PPR Union 25mm |
| 73 | PPR Union 32mm |
| 74 | PPR Union 40mm |
| 75 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) : |
| 76 | 90x80 cm |
| 77 | 60x60 cm |
| 78 | 45x45 cm |
| 79 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc complete.For pipes 250 to 300 mm diameter |
| 80 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 Gthickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth toline and level including necessary supports, scaffolding etc. as requiredand also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete.12.47.1 Including providing and fixing expanded metal of size 5.25mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thicknessnot less than 10 mm |
| 81 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in-charge (Frame work shall be paid for separately).12mm thick commercial ply conforming to S : 1328 BWR type |
| 82 | Manufacturing of single bed (6\"-6\"x3\"-0) x1\"-2\" size box type manufactured out of 18 mm ISI brand plywood (ply to ply) with base and top of box with requisite wooden supports as required. The head side shall be 2\"-6\" and foot side 0\"-6\" above the top surface of the box as per the design and drawings provided by the Engineer in Charge. The headside, footside and two side to be fixed with 4 No. bed bolts. The rate shall include 75mm bolts.The rate shall also include 75mm wide 12mm thick ply lipping and finished with 0.8mm thick dulmica on all expoded sides and all required wooden beedings as per design and all hardware fittings including hinges. Please Enable Macros to View BoQ information |
| 83 | Manufacturing of single bed (6\"-6\"x3\"-0) x1\"-2\" size box type manufactured out of 18 mm ISI brand plywood (ply to ply) with base and top of box with requisite wooden supports as required. The head side shall be 2\"-6\" and foot side 0\"-6\" above the top surface of the box as per the design and drawings provided by the Engineer in Charge. The headside, footside and two side to be fixed with 4 No. bed bolts. The rate shall include 75mm bolts.The rate shall also include 75mm wide 12mm thick ply lipping and finished with 0.8mm thick dulmica on all expoded sides and all required wooden beedings as per design and all hardware fittings including hinges. Please Enable Macros to View BoQ information |