| 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: NOTE rate quoted inclusive of scaffolding charges at all heightsG.S. Sheet or Similar |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 500 m and for all lift |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 4 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:Channels, angles, tees and flats, M.S/G.I mesh |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.00 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 M sand) |
| 6 | 15 mm cement plaster on rough side of single or half brick wall of mix including scaffolding at all heights:1:4 (1 cement: 4 M sand) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 M sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)Make: JINDAL or its equivalent |
| 9 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)(Plain /Pin Headed glass) MAKE: SAINT GOBIAN OR MODI |
| 10 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubesMake: Apollo/TATA/Vizag |
| 11 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shapeMAKE: JSW |
| 12 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)MAKE: JSW |
| 13 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. Make: TATA, APOLO or its equivalent |
| 14 | Laying Vitrified tiles in floor (antiskid) in different sizes (thickness to be specified by the manufacturer) in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 M sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.(Tiles will be supplied departmentaly) Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600x600 mm |
| 15 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mmMake: Leticrete, Asian Paints or FOSROCK |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.MAKE: asian - apcolite gloss enamel OR Nerolac – synthetic enamel OR Dulux - Gloss enamel |
| 17 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel worksAsian/Delux or its equivalent |
| 18 | Providing and applying whitecement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Make: JK Wall putty/ Birla Wall Care |
| 19 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)MAKE: asian (Apex) or Nerolac |
| 20 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Voatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour:Two coatsMAKE: asian/ NEROLAC/ Dulux |
| 21 | Providing and fixing in position Stainless Steel Turbo ventilators of approved design including cutting the roof sheet to the requird size, sealing the gap with appropriate sealant long with polycarbonate transparent sheet (thickness as specified by the engineer incharge), etc complete.Make: Any ISI brand |
| 22 | Supplying, Installation, Testing & Successful Commissioning of IP65 30 Watts LED Focus Light (Day Cool Light) complete with internal wiring, upto 1 metre length of any standard make rated 3 core copper wire etc., ready to use suitable to fix on wall / ceiling and to work with 230V Single Phase, 50Hz AC Supply. Make:Please refer Special Electrical Conditions under Tender Document File. |
| 23 | Supplying, Installation, Testing & Successful Commissioning of IP65 50 Watts LED Focus Light (Day Cool Light) complete with internal wiring, upto 1 metre length of any standard make rated 3 core copper wire etc., ready to use suitable to fix on wall / ceiling and to work with 230V Single Phase, 50Hz AC Supply. Make:Please refer Special Electrical Conditions under Tender Document File. |
| 24 | Supplying, Installation, Testing & Successful Commissioning of 16 Modular PVC BOX along with Modular Base & Cover Plate for Modular Switches and Sockets in recess / wall using suitable hardwares etc. as required, making good the damage in case of recess fixing for plastering etc., as per directions of Engineer In-Charge. Following Modular items a) 5/6 Amp Switch - 2 Nos;b) 3/5 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 15/16 Amp Switch - 2 Nos; d) 6 pin 15/16 Amp Socket Outlet - 2 Nos and e) 20 Amps, 2 Pole, \"C\" Curve, 10kA, 230V Mini MCB - 1 No; Internal wirings for 5 Amps Switch & Socket with 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire; for 15 Amps Switch & Socket with 6.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire, 4.0 sq.mm Green Colour for Earthing Loop and terminate all the wires using suitable size Copper Lugs as required to be provided. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 25 | Supply,Installation, Testing and Successful Commissioning of 12 Inch Dia, 300 mm sweep, industrial type ready to useHeavy Duty Exhaust Fan having Bird Cage with 1.5 FRLS PVC insulated, copper conductor, single core cable and to fix with required size of MS frame duly painted with one coat of primer and 2 coats of paint, suitable hardwares etc., and provide one no. of 3 Pin 5/6 Amps ISI make Socket along with Gangbox and 3 Pin 5/6A Amps ISI make Plugtop as required. Make for All:Please refer Special Electrical Conditions under Tender Document File. |
| 26 | Supplying and fixing of heavy-duty metal bus bar chamber of 100 Amps, 415 Volts grey painted, complete with tinned copper bus bars, insulators, copper lugs for cable terminations, and all necessary connections as required.outdoor type |
| 27 | Supply, Installation, Successful Commissioning and Testing of LT Double Door IP55 Indoor Panel Boxmade out of 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of red oxide & 2 coats of Siemens Gray colourpaint and consisting of items as mentioned in a) to h). Newly laid 4 x 50 sq.mm XLPEAluminium UG Cable shall be terminated as Incoming to 250A MCCB. The Output from the 250A MCCB shall be connected to 4 x 250A range Individual Copper Cable / Copper Bus-Bars. From the Bus-Bar, input shall be tapped for 4 x 63 Amps 4 Pole MCB - 4 nos, 3 x 32 Amps 4 Pole MCB, 3 x 32 Amps 2 Pole MCB through rated FRLS multistrand copper wire using suitable type of lugs and standard colour code of wiring, neatly dressed. All new / existing out-going Cables / Circuits to be connected to this LT Panel. A Separate Aluminium Bus-Bar for connecting the Sub-Circuits Earth Wires in the Panel and extended for 2 Inches outside the Panel on both sides, for connecting Bare Copper Wires from the Earthpit should be provided. 4 Nos of plate cutting for fixing glands, entry and exit of Copper / UG Cable(s), Cable Alley are to be made available. The panel shall be have individual hinges with locking arrangement doors for each MCB / RCCB / MCCB distribution chamber within the compartment. The LT Box shall be mounted on the floor with total stand height of 0.75-1.5 Feet grouted to the floor, doors on front with locking arrangements. The stand portion from the floor on all 4 sides shall be suitable covered with removable type metal sheet (screwed to the stand) painted with same colour as of LT Box. All visible Bus-Bars inside the Panel shall be suitably covered with the 6mm Hylem sheets from. 6\" x 6\" water proof vents shall be provided on both the sides of the Panel, covered with wire mesh from inside. Important:All incoming / outgoing armoured cables / Sub-Main Circuits shall be terminated with suitable size copper / aluminiumlugs (for copper cables / wires, coppler lugs and for aluminium cables / wires, aluminium lugs). During connections, if any Incoming / Outgoing cables is / are need to be extended, part of the work (Cable/ Wires for extension of connection will be provided by CSIR-CFTRI).S.No: a), f), h) g) Make: Any ISI Brand; S.No: b) to e)Make: UG Cable Make:Please refer Special Electrical Conditions under Tender Document File. . Panel Design: As per Engineer In-Charge. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker.a) Copper Bus Bar of size 50mm x 5 mm insulated with fire proof tape, 415v, 250Amps, mounted on Bus Bar Insulators. - 04 Nos.b) 250A, 36KA, 4Pole MCCB - 01 No. c) 32Amps, 4pole MCB - 03 Nos.d) 63 A, 4Pole MCB - 04 Nos.e) 32A, 2pole, 10kA, 230v MCB - 03 Nos.f) RYB LED Phase Indication Lamps with Fuse Unit for Input and Output - 2 Sets.g) HT Rubber Mat of 6\" x 3\" - 01 No.h) Aluminium Earth Bus-Bar 50mm x 5mm - 01 No. |
| 28 | Labour charges for digging upto 8 feet of depth below ground level, including hard soil, rocks, cement surface etc.,if any encountered, fixing the Item No:20, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:20 as required, already estimated under S.No.20). |
| 29 | Dismantling & taking down Old light Fittings / related wirings, hardwares etc., after carefully disconnecting the incoming electrical input and insulating the same, depositing all the old materials in an organised manner to the Auction / Electrical Section Store Yard or as per the advise of the Electrical Officer In-Charge of the Project without any damage. For every Toilet it is the responsibility of the contractor to disconnect the incoming supply , insulate the same while caring Civil works . After the complition with new electriacl equipment reconnecting , however engineer in charge will advise for the source of power supply |
| 30 | Wiring for circuit / submain wiring with 4 X 25 sq. mm + 2 X 16 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class suitable size PVC conduit as required. Make: Please refer Special Electrical Conditions under Tender Document File. Note: All start & end point of the wires are to be terminated with \"Cu\" Lugs of suitable type and size. |
| 31 | Supplying of 4 Core x 50.0 sq. mm PVC insulated and PVC sheathed / XLPE aluminium armoured conductor cable of 1.1 KV grade. To lay the cable as per Item No:23 , 24 , 25 & 26. UG Cable Make:Please refer Special Electrical Conditions under Tender Document File. |
| 32 | Supplying, Installation, Testing & Successful Commissioning of 8 Modular PVC BOX along with Modular Base & Cover Plate for Modular Switches and Sockets in recess / wall using suitable hardwares etc. as required, making good the damage in case of recess fixing for plastering etc., as per directions of Engineer In-Charge. Following Modular items a) Socket type 32 Amps Mini MCB - 1 Nos; b) 15/16 Amp Switch - 4 Nos; c) 6 pin 15/16 Amp Socket Outlet - 1 Nos andInternal wirings forfor 15 Amps Switch & Socket with 6.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and 6.0 sq.mm FRLS Multistrand, Single Core Copper Wire, 4.0 sq.mm Green Colour for Earthing Loop and terminate all the wires using suitable size Copper Lugs as required to be provided. Make: Please refer Special Electrical Conditions under Tender Document File. |
| 33 | Supplying, Installation, Testing & Successful Commissioning of 63 Amp, 415V AC, 4 Pole MCB, having 30mA sensitivity \"C\" Curve, 10kAfixed in ExistingMetal Bo., including connections etc. as required. Make: Please refer Special Electrical Conditions under Tender Document File.In the item No:15 |
| 34 | Wiring for circuit / submain wiring alongwith earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.Make: Please refer Special Electrical Conditions under Tender Document File |
| 35 | Wiring for circuit / submain wiring alongwith earth wire with 2 X 4 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.Make: Please refer Special Electrical Conditions under Tender Document File |
| 36 | Wiring for circuit / submain wiring alongwith earth wire with 4 X 6 sq. mm + 2 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.Make:Please refer Special Electrical Conditions under Tender Document File. |
| 37 | Supplying and fixing 30A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioing etc. as required. Make:Please refer Special Electrical Conditions under Tender Document File. |
| 38 | Supplying and fixing 20A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioing etc. as required. Make:Please refer Special Electrical Conditions under Tender Document File. |
| 39 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.Make:Please refer Special Electrical Conditions under Tender Document File. |
| 40 | Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. Note: Masonry enclosure size is 1.5 Feet x 1.5 Feet x 1.5 Feet.As per IS 3043, charcoal/ coke and salt should be refilled with 50 Kg each per earthpit. The copper plate has to be tinned, connected copper flats have to be brazed and only SS nut, bolts and washers to be used. |
| 41 | Providing and laying earth connection from earth electrode with 4.00mm dia copper wire in 15mm G.I. pipefrom earth electrode including connection with copper thimble excavation and refilling as required. |
| 42 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 43 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 44 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 35 sq. mm and upto 95 sq. mm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 45 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mmMS flat clamp) |
| 46 | Providing, laying and fixing 100 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trench ( 75 cm deep) and re-filling etc. as requiredG.I Pipe Make: Please refer Special Electrical Conditions under Tender Document File. |
| 47 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 x 50 sq. mm (35mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Brass Compression Gland and Aluminium LugsMake: Please refer Special Electrical Conditions under Tender Document File. Note: Each means lugs for all leads at one end of the UG Cable. |
| 48 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. Water bound macadam. |
| 49 | Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tampling complete. |