| 1 | : C-1.2 Material (ERP NO- 282124 |
| 2 | 11 KV Pin Insulator Polymer Composit (5 KN) |
| 3 | Erection Cost Of 11 KV Pin Insulator Polymer Composit (5 KN) |
| 4 | 11 KV Strain hardware (T&C type) fittings |
| 5 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 6 | Fixing of Disc Insulator with H/ W 11 KV side |
| 7 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 8 | Labour charge for erection of 140 Kg.,8.0 Mtrs. long PCC pole (Erection charge @60%+Transportation charge@40%) |
| 9 | AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) |
| 10 | Erection cost of AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) |
| 11 | 11 KV Single pole cut point fitting 100x50x6 mm channel |
| 12 | Erection cost of 11 KV Single pole cut point fitting 100x50x6 mm channel |
| 13 | 11 KV Top clamp 65X65X6 mm. angle type |
| 14 | 11 KV V cross arm 65X65X6 mm. angle type |
| 15 | Fixing of 11 KV V-cross arm with Top Clamp |
| 16 | Aluminium Binding wire and tape |
| 17 | Aluminium paint |
| 18 | Erection cost of Aluminium paint |
| 19 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 20 | Erection cost of Anti climbing Device (Barbed Wire) GS 2.24 mm Dia (14 SWG) |
| 21 | Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 22 | Back filling of poles with boulders. |
| 23 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 24 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 25 | Erection cost of Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 26 | Danger Boards Enamelled 11 KV |
| 27 | Eretion cost of Danger Boards Enamelled 11 KV |
| 28 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 29 | G.I. WIRES 4.0 MM. (8 SWG) |
| 30 | Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor |
| 31 | M.S.Nuts with Bolts |
| 32 | Red oxide paint |
| 33 | Stay Insulators 90X65mm |
| 34 | Stay set complete without Stay wire 16 mm. (Painted) |
| 35 | Labour for Stay set complete without Stay wire 16 mm. (Painted) |
| 36 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 37 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 38 | GST 18% |
| 39 | : D-2.1 Material (ERP NO- 282124 |
| 40 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 41 | Labour charge for erection of 140 Kg.,8.0 Mtrs. long PCC pole (Erection charge @60%+Transportation charge@40%) |
| 42 | LT Aerial bunched XLPE Cable 3 X 25+ 1 X 16+ 1 X 25 sqmm with aluminium alloy Bare messenger wire |
| 43 | Erection cost of LT Aerial bunched XLPE Cable 3 X 25+ 1 X 16+ 1 X 25 sqmm with aluminium alloy Bare messenger wire |
| 44 | Back filling of poles with boulders. |
| 45 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 46 | Clamps for neutral for AB Cable |
| 47 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 48 | Erection cost of Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 49 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 50 | Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole |
| 51 | LT A B cable Suspension clamps (Galvanized) |
| 52 | Erection cost of LT A B cable Suspension clamps (Galvanized) |
| 53 | LT A.B Cable tension clamps (Galvanized) |
| 54 | Erection cost of LT A.B Cable tension clamps (Galvanized) |
| 55 | M.S.Nuts with Bolts |
| 56 | Piercing connector Type-I for single/three phase (Main 16-50 sqmm tap-off 16-50 sqmm) |
| 57 | Piercing connector Type-II (Main 16-50 sqmm tap-off 16-50 sqmm) |
| 58 | Single Phase Service connection box (Deep Drwan Metal Service Connection Boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- |
| 59 | Erection cost of Single Phase Service connection box (Deep Drwan Metal Service Connection Boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- |
| 60 | Stay Insulators 90X65mm |
| 61 | Stay set complete without Stay wire 16 mm. (Painted) |
| 62 | Erection cost of Stay set complete without Stay wire 16 mm. (Painted) |
| 63 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 64 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 65 | GST 18% |
| 66 | : E-1.1 Material : 1x25 KVA DTR ( ERP NO- 282124 |
| 67 | 11 KV D.O. Fuse Unit Polymer type |
| 68 | Erection cost of 11 KV D.O. Fuse Unit Polymer type |
| 69 | 11 KV Strain hardware (T&C type) fittings |
| 70 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 71 | Fixing of Disc Insulator with H/ W 11 KV side |
| 72 | 11/0.4 KV Distribution transformer 25 KVA (Conventional) (Aluminium wound)(Rep-BGP) |
| 73 | Handling & Installation of Distribution Transformer (DTR) on DP, tightening with turn buckles on both sides, poles clamping and bolting of base jumpering on HT side |
| 74 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 75 | Labour charge for erection of 140 Kg.,8.0 Mtrs. long PCC pole (Erection charge @60%+Transportation charge@40%) |
| 76 | 9 KV Gapless type ( 5KA) Polymer for DTR |
| 77 | Erection cost of 9 KV Gapless type ( 5KA) Polymer for DTR |
| 78 | AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) |
| 79 | XLPE Cable 1 core unarmoured 35 sqmm Aluminium conductor 1100 Volts |
| 80 | XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts |
| 81 | Aluminium paint |
| 82 | Erection cost of Aluminium paint |
| 83 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 84 | Erection cost of Anti climbing Device (Barbed Wire) GS 2.24 mm Dia (14 SWG) |
| 85 | Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 86 | Bi-metallic clamps Distribution Transformers Bushing |
| 87 | Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC |
| 88 | Category: D3: Three Phase LT-CT operated Smart Meter- DT Meter with |
| 89 | Erection cost of Category: D3: Three Phase LT-CT operated Smart Meter- DT Meter with |
| 90 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 91 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 92 | Erection cost of Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 93 | Concreting of structures & foundation (1:3:6) |
| 94 | Erection cost of Concreting of structures & foundation (1:3:6) |
| 95 | D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel |
| 96 | Erection cost of D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel |
| 97 | D.O.Mounting Channel 75x40x6mm |
| 98 | Erection cost of D.O.Mounting Channel 75x40x6mm |
| 99 | Danger Boards Enamelled 11 KV |
| 100 | Erection cost of Danger Boards Enamelled 11 KV |
| 101 | EARTHING SET (40MM , 3 METER GI PIPE , GI WIRE, EARTHING CLMAP AND NUT BOLT) |
| 102 | LT Robust Fuse Unit |
| 103 | M.S.Nuts with Bolts |
| 104 | Red oxide paint |
| 105 | Erection cost of Red oxide paint |
| 106 | Stay Insulators 90X65mm |
| 107 | Stay set complete without Stay wire 16 mm. (Painted) |
| 108 | Erection cost of Stay set complete without Stay wire 16 mm. (Painted) |
| 109 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 110 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 111 | Trans. Belting with 50 X 50 X 6 mm.angle with two cross fixing channels |
| 112 | Transformer mounting Channel (100X50x6 mm.) |
| 113 | Erection cost of Transformer mounting Channel (100X50x6 mm.) |
| 114 | GST 18% |
| 115 | C-1.2 Material (ERP NO- 282341 |
| 116 | 11 KV AL 59 ACS Covered Conductor 78.82 sq.mm along with MVCC accessories as per EN:50397 Calculated for 1 KM Single Phase Feeder, tension/dead/anchoring clamps with piercing connector suitable for MVCC, IPC for CC to CC connection,EN-50397 -P-2 |
| 117 | Erection cost of 11 KV AL 59 ACS Covered Conductor 78.82 sq.mm along with MVCC accessories as per EN:50397 Calculated for 1 KM Single Phase Feeder, tension/dead/anchoring clamps with piercing connector suitable for MVCC, IPC for CC to CC connection,EN-50397 -P-2 |
| 118 | 11 KV Pin Insulator Polymer Composit (5 KN) |
| 119 | Erection Cost Of 11 KV Pin Insulator Polymer Composit (5 KN) |
| 120 | 11 KV Strain hardware (T&C type) fittings |
| 121 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 122 | Fixing of Disc Insulator with H/ W 11 KV side |
| 123 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 124 | Labour charge for erection of 140 Kg.,8.0 Mtrs. long PCC pole (Erection charge @60%+Transportation charge@40%) |
| 125 | AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) |
| 126 | Erection cost of AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) |
| 127 | H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-13 mtr. Long = 482.3 kg |
| 128 | Erection cost of material with transportation for H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-13 mtr. Long = 482.3 kg |
| 129 | 11 KV Single pole cut point fitting 100x50x6 mm channel |
| 130 | Erection cost of 11 KV Single pole cut point fitting 100x50x6 mm channel |
| 131 | 11 KV Top clamp 65X65X6 mm. angle type |
| 132 | 11 KV V cross arm 65X65X6 mm. angle type |
| 133 | Fixing of 11 KV V-cross arm with Top Clamp |
| 134 | Aluminium Binding wire and tape |
| 135 | Aluminium paint |
| 136 | Erection cost of Aluminium paint |
| 137 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 138 | Erection cost of Anti climbing Device (Barbed Wire) GS 2.24 mm Dia (14 SWG) |
| 139 | Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 140 | Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) |
| 141 | Back filling of poles with boulders. |
| 142 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 143 | Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) |
| 144 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 145 | Erection cost of Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 146 | Concreting of structures & foundation (1:3:6) |
| 147 | Erection cost of Concreting of structures & foundation (1:3:6) |
| 148 | Danger Boards Enamelled 11 KV |
| 149 | Erection cost of Danger Boards Enamelled 11 KV |
| 150 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 151 | G.I. WIRES 4.0 MM. (8 SWG) |
| 152 | Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor |
| 153 | M.S.Nuts with Bolts |
| 154 | Red oxide paint |
| 155 | Erection cost of Red oxide paint |
| 156 | Stay Insulators 90X65mm |
| 157 | Stay set complete without Stay wire 16 mm. (Painted) |
| 158 | Erection cost of Stay set complete without Stay wire 16 mm. (Painted) |
| 159 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 160 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 161 | GST 18% |
| 162 | : D-2.1 Material (ERP NO- 282341 |
| 163 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 164 | Labour charge for erection of 140 Kg.,8.0 Mtrs. long PCC pole (Erection charge @60%+Transportation charge@40%) |
| 165 | LT Aerial bunched XLPE Cable 3 X 25+ 1 X 16+ 1 X 25 sqmm with aluminium alloy Bare messenger wire |
| 166 | Erection cost of LT Aerial bunched XLPE Cable 3 X 25+ 1 X 16+ 1 X 25 sqmm with aluminium alloy Bare messenger wire |
| 167 | Back filling of poles with boulders. |
| 168 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 169 | Clamps for neutral for AB Cable |
| 170 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 171 | Erection cost of Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 172 | Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire |
| 173 | Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole |
| 174 | LT A B cable Suspension clamps (Galvanized) |
| 175 | Erection cost of LT A B cable Suspension clamps (Galvanized) |
| 176 | LT A.B Cable tension clamps (Galvanized) |
| 177 | Erection cost of LT A.B Cable tension clamps (Galvanized) |
| 178 | M.S.Nuts with Bolts |
| 179 | Piercing connector Type-I for single/three phase (Main 16-50 sqmm tap-off 16-50 sqmm) |
| 180 | Piercing connector Type-II (Main 16-50 sqmm tap-off 16-50 sqmm) |
| 181 | Single Phase Service connection box (Deep Drwan Metal Service Connection Boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- |
| 182 | Erection cost of Single Phase Service connection box (Deep Drwan Metal Service Connection Boxes )with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- |
| 183 | Stay Insulators 90X65mm |
| 184 | Stay set complete without Stay wire 16 mm. (Painted) |
| 185 | Erection cost of Stay set complete without Stay wire 16 mm. (Painted) |
| 186 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 187 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 188 | GST 18% |
| 189 | : E-1.1 Material : 1x25 KVA DTR ( ERP NO- 282341 |
| 190 | 11 KV D.O. Fuse Unit Polymer type |
| 191 | Erection cost of 11 KV D.O. Fuse Unit Polymer type |
| 192 | 11 KV Strain hardware (T&C type) fittings |
| 193 | 11 KV(45KN) Composite Polymer Disc Insulators |
| 194 | Fixing of Disc Insulator with H/ W 11 KV side |
| 195 | 11/0.4 KV Distribution transformer 25 KVA (Conventional) (Aluminium wound)(Rep-BGP) |
| 196 | Handling & Installation of Distribution Transformer (DTR) on DP, tightening with turn buckles on both sides, poles clamping and bolting of base jumpering on HT side |
| 197 | 140 Kg.,8.0 Mtrs. long PCC pole |
| 198 | Labour charge for erection of 140 Kg.,8.0 Mtrs. long PCC pole (Erection charge @60%+Transportation charge@40%) |
| 199 | 9 KV Gapless type ( 5KA) Polymer for DTR |
| 200 | Erection cost of 9 KV Gapless type ( 5KA) Polymer for DTR |
| 201 | AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) |
| 202 | XLPE Cable 1 core unarmoured 35 sqmm Aluminium conductor 1100 Volts |
| 203 | XLPE Cable 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts |
| 204 | Aluminium paint |
| 205 | Erection cost of Aluminium paint |
| 206 | Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) |
| 207 | Erection cost of Anti climbing Device (Barbed Wire) GS 2.24 mm Dia (14 SWG) |
| 208 | Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 209 | Bi-metallic clamps Distribution Transformers Bushing |
| 210 | Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC |
| 211 | Category: D3: Three Phase LT-CT operated Smart Meter- DT Meter with |
| 212 | Erection cost of Category: D3: Three Phase LT-CT operated Smart Meter- DT Meter with |
| 213 | Clamp for 140 Kg PCC Pole MS Flat 50x6 mm |
| 214 | Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 215 | Erection cost of Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay |
| 216 | Concreting of structures & foundation (1:3:6) |
| 217 | Erection cost of Concreting of structures & foundation (1:3:6) |
| 218 | D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel |
| 219 | Erection cost of D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel |
| 220 | D.O.Mounting Channel 75x40x6mm |
| 221 | Erection cost of D.O.Mounting Channel 75x40x6mm |
| 222 | Danger Boards Enamelled 11 KV |
| 223 | Erection cost of Danger Boards Enamelled 11 KV |
| 224 | EARTHING SET (40MM , 3 METER GI PIPE , GI WIRE, EARTHING CLMAP AND NUT BOLT) |
| 225 | LT Robust Fuse Unit |
| 226 | M.S.Nuts with Bolts |
| 227 | Red oxide paint |
| 228 | Erection cost of Red oxide paint |
| 229 | Stay Insulators 90X65mm |
| 230 | Stay set complete without Stay wire 16 mm. (Painted) |
| 231 | Erection cost of Stay set complete without Stay wire 16 mm. (Painted) |
| 232 | STAY WIRE 7/3.15 MM.(7/10 SWG) |
| 233 | Stone Block/Pre cast block for base pedding(450X450X75MM) |
| 234 | Trans. Belting with 50 X 50 X 6 mm.angle with two cross fixing channels |
| 235 | Transformer mounting Channel (100X50x6 mm.) |
| 236 | Erection cost of Transformer mounting Channel (100X50x6 mm.) |
| 237 | GST 18% Please Enable Macros to View BoQ information |