Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Main Building |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth as directed by Engineer-in-Charge.All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 4 | Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete. |
| 5 | Providing and laying in position cement concrete of specified grade M-7.5 including curing but excluding the cost of centering and shuttering - All work upto plinth level with 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) i/c all carriages |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) i/c all carriages |
| 7 | Filling in with nallah boulders (75mm to 150mm thick) under floor handpacked & rammed complete |
| 8 | Dewatering of trenches / Pumping out water caused by springs etc |
| 9 | Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto plinth level incld all costs and carriages, complete. |
| 10 | Above Plinth Level |
| 11 | Reiforcement for R.C.C work including straightening, cutting, bending, placing in position & binding with binding wire all complete, Thermo Mechanically Treated Bars (500 D) (All work at all levels complete). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 13 | Foundations, footings, bases of columns etc for mass concrete. |
| 14 | Lintels ,Beams ,Plinth Beams, Griders , Bressumers and cantilevers |
| 15 | Columns, pillars piers, abutments, posts and struts |
| 16 | Stairs, (excluding landings) except spiral staircases : |
| 17 | Suspended floors, roofs, landings, balconies and access plateform |
| 18 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 above plinth upto floor V level including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 19 | Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fastenersshall be paid for separately):ist class kail wood |
| 20 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions wit+C301h wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge :Imported Wood (35mm Thick) |
| 21 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Imported Wood (30mm thick) |
| 22 | Providing and fixing panelling or panelling and glazing in panelled or panelledand glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to bemeasured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick. Imported wood |
| 23 | Painting with synthetic enamel paint of approved brand and manufactureto give an even shade. Two or more coats on new work. |
| 24 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with10 mm diameter bolts, nuts and wooden plugs and embeddings in cementconcrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). |
| 25 | Providing/Fixing ISI Marked M.S fittings as per the directions of engineer in charge |
| 26 | A) T.Bolts |
| 27 | i) 100 mm |
| 28 | ii) 150 mm |
| 29 | B) Handles |
| 30 | i) 125 mm |
| 31 | ii) 150 mm |
| 32 | C) L-drops (Link) |
| 33 | i) 200 mm |
| 34 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand) |
| 35 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand |
| 36 | 6mm cement plaster to ceilings of mix 1:3 (1 cement : 3 fine sand) |
| 37 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 38 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 39 | Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50mm thick with 20mm nominal size stone aggregate incl carriage |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 41 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In all colours, shades, except White, Ivory, Fume Red Brown |
| 42 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600mm |
| 43 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 44 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 45 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brickballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 46 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded @ 55 kg/sqm |
| 47 | Providing and Fixing of Hig Rib colour coated Sheet roofing of 0.50mm including polymer coated J or L Hooks and GI limpit washer Including Ridges and Valleys complete job including evaes boards |
| 48 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour or shade Area of slab >0.5m^2 |
| 49 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. IMPORTED WOOD INCLD. Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type |
| 50 | Sanitary |
| 51 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (Hand lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. W.C pan with ISI marked white solid plastic seat and lid. |
| 52 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps (01 Nos), 32 mm C.P. brass waste of standard pattern(01 Nos), including painting of fittings and brackets, cutting and making good the walls wherever required. White vitreous china wash basin size 550x400 mm with a pair of 15mm C.P. brass pillar taps. |
| 53 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings |
| 54 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular shape 453x357 mm |
| 55 | Providing and fixing toilet paper holder C.P brass |
| 56 | Providing and fixing PTMT Soap Dish holder having length os 138 mm breadth 102mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms |
| 57 | Providing and fixing health faucet with hose pipe for european water closet complete in all respect of approved quality (HINDWARE) |
| 58 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms . |
| 59 | Providing anf fixing 15 mm nominal bore C. P brass bib cock of approved quality |
| 60 | Providing and fixing 15 mm nomonal bore C.P brass angle value for basin mixer and geyser of approved make confirming to IS: 8931 |
| 61 | Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete 25 mm nominal bore |
| 62 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore |
| 63 | Providing and fixing C.P. brass 32 mm size bottle trap of approved quality and make and as per the directions of engineer in charge. |
| 64 | Providing and fixing 15 mm nominal bore of standard back type C.P. Brass |
| 65 | P/F long brass single long swing type lever wall sink mixer |
| 66 | Kitchen sink 600x510x200 mm incld. All Fittings |
| 67 | P/F PVC stay and clamps for PVC Pipes |
| 68 | 100mm |
| 69 | P/F bend of required degree |
| 70 | 100mm |
| 71 | P/F of plain bends |
| 72 | 100mm |
| 73 | P/f Tee junction |
| 74 | 100mm |
| 75 | 75 mm |
| 76 | P/f Pvc reducer 100- 50mm dia |
| 77 | P/f cp grating 100 mm dia |
| 78 | P/F CP bend of door bend |
| 79 | 100mm |
| 80 | P/F Gyser of approved brand and make with all fittings |
| 81 | 50 litre Gyser |
| 82 | Providing and fixing 3 layer PP-R popes conformin got IS: 15801, UV Stablised an danti micorbal fusion welded , having thermal stablity for hot and cold water |
| 83 | PN-16 PIPE, 25MM OD |
| 84 | PN-16 PIPE, 32MM OD |
| 85 | Providing and fixing PPR unions |
| 86 | PPR Union 25 mm |
| 87 | PPR Union 32 mm |
| 88 | Providing and fixing water pump 2hp of approved make |
| 89 | Providing and placing on terrace (at all floor levels ) Polythene water storage tank ISI: 12701 marked , with cover all complete |
| 90 | Providing and fixing testing commisioning Upvc SwR Pipes (type B) for soil , waste and vent conforming oto IS 13592 |
| 91 | 110mm dia |
| 92 | 150mm dia |
| 93 | 75mm dia |
| 94 | 50mm dia |
| 95 | constructing brick massonary manhole in cement mortar 1:4 ( 1 cemnt :4 coarse sand ) RCC top slab with 1:1.5: 3 mix (1 cemnet :1.5 coarse and (zone -III) : 3 graded stone agg 20 mm nominal |
| 96 | Boundary Wall |
| 97 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:. all kinds of soils |
| 98 | Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete. |
| 99 | Providing and laying in position cement concrete of specified grade M-10 including curing but excluding the cost of centering and shuttering - All work upto plinth level with 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) incl carriage |
| 100 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 101 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m |
| 102 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 103 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 104 | Reiforcement for R.C.C work including straightening, cutting, bending, placing in position & binding with binding wire all complete, Thermo Mechanically Treated Bars (500 D) (All work at all levels complete). |
| 105 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 106 | Foundations, footings, bases of columns etc for mass concrete. |
| 107 | Columns, pillars piers, abutments, posts and struts (R wall stem) |
| 108 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 109 | Steel work welded in built up sections/framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 110 | Internal Road with bituminous top |
| 111 | Providing, Laying, spreading and compacting stone aggregate of specified sizes(63-45mm, 45-22.4mm and Type A Screening)to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density |
| 112 | Providing,Laying and Compacting RBM in layers not exceeding 200mm in depth using a powerful road roller. Rolling from edges towards centre to provide a proper camber |
| 113 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge |
| 114 | Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface and cleaning with mechanical broom On W.B.M. /W.M.M. @ 0.4 Kg/sqm. With medium setting bitumen emulsion |
| 115 | Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge. 50 to 100 mm average compacted thickness with bitumen of grade VG-10 @ 3.5% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity. |
| 116 | Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. 25 mm compacted thickness with bitumen of grade VG-10 @ 5% (percentage by weight of total mix) and lime filler @ 2%(percentage by weight of Aggregate) prepared in Drum Type Hot MixPlant of 60-90 TPH capacity. |
| 117 | Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg ofbitumen of grade VG-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete. |
| 118 | Site clearence / Dismentelling |
| 119 | Surface dressing of the ground including removing vegetation and in-equalitiesnot exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto1.5 m in -All kinds of soil. |
| 120 | Demolishing cement concrete manually/by mechanical means includingdisposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 121 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: 15.7.4 In cement mortar |
| 122 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of :G.S. Sheet |
| 123 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : Of sectional area 40 sqcm. and above. |
| 124 | Septic and soakage |
| 125 | Earth work in bulk excavation in all kinds of soil exceeding 10sqm in plan and 0.3m in depth by manual or mechanical means up to required width and depth including ramming of bottom and dressing of sides, clearing of vegetationand disposal of excavated materials with its leads, lifts and carriage as will be directed at site complete. |
| 126 | P/L, of dry stone soling nominal size duly hand packed with ramming, dressing, watering and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 127 | P/L, in position cement concrete of specified grade excluding the cost of centering & shuttering. All work up to plinth level in 1:4:8 (1cement: 4 coarse, sand: 8 graded stone aggregate of 40 mm Nominal size (Crushed) all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 128 | P/L, in position cement concrete of specified grade excluding the cost of centering & shuttering. All work up to plinth level in 1:1.5:3 (1cement: 4 coarse, sand: 8 graded stone aggregate of 40 mm Nominal size (Crushed) all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete. |
| 129 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) incl carriage |
| 130 | Dry Random Rubble Masonary with hard stones using quarry stone incl. c/o band stones and all carriage. |
| 131 | Centering and Shuttering including strutting, propping etc removal of form work in Suspended Floors |
| 132 | Providing and fixing steel reinforcements incl. straightening,bending and binding complete. |
| 133 | 12mm thick cement sand plaster in 1:4 mix with neat coat of cement. |
| 134 | Electric Part |
| 135 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC Insulated flexible stranded copper conductor wires in recessed or surface medium class PVC condult along with 1x4 sq. mm FRLS PVC Insulated copper conductor single core cable for loop earthing, etc, as required. (Maximum two points shall be connected on one circult). (Havels/ Polycab/ Anchor/Finolex/KEI/RR or equivalent) Incl. cost of condult |
| 136 | Supplying and fixing of sultable size Gl box with modular plate and modular cover In front on surface or in recess, Including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/SSK/Anchor/ ABB/Schneider or equivalent) |
| 137 | Supplying and fixing of suitable size Gl box with modular plate and modular cover 3 in front on surface or in recess, Including providing and fixing of 2 no.3 pln 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/SSK/ Anchor/ ABB/Schneider or eq.) |
| 138 | Supplying and fixing of sultable size it box with modular plate and mudular cover 30 In front on surface or in recess, including providing and fuing of 2 no.3 pln 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connectiom, etc. as required. (Havells/SSK/ Anchor/ABB/Schneider or eq.) |
| 139 | Supplying and fixing of modular sockets/Indicators/switches on existing modular plate and switch box, Incl. connections, etc. as required. (Havells/ SSK/ Anchor/ABB/Schneider or equivalent) |
| 140 | 1. 3 pin 5A 10A socket. |
| 141 | Indicator. |
| 142 | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC Insulated 660/1100volt grade flexible stranded copper conductor wires In recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing), (Maximum two points shall be connected on one circuit). (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) Incl. cost of conduit |
| 143 | Supply, Installation, testing and commissioning of 18 Watt LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India, Operating temperature -10°C to +45°C. The Job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/Philips/Crompton/Jaguar/Wipro). Commercial series.. |
| 144 | Supply, Installation, testing and commissioning of 1 star 1200 mm sweep celling fans of Havells/Crompton Greaves/Bajaj/ Usha, Incl. cost of extension of Gl rod (if required) and making of necessary connections. |
| 145 | Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, Incl. connections but excl. modular plate etc. |
| 146 | Supply, Installation, testing and commissioning of 10 Watt (2 feet long) LED wall mounted batten (tube lights) having aluminum housing, minimum 100lm/w, average life 50000 hours (Commercial series) The Job Includes replacement warranty of fixture If damaged/ burnt out what so ever reason for a period of one year reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells). |
| 147 | Supply, Installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, Incl. making of space in walls/ |
| 148 | Supply, Installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100lm / w_{1} the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature - 10 deg * C to 45 deg * C LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India. The Job Includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissloning/ handing over of site to the intending department |
| 149 | Supplying and fixing of modular blanking plates on existing modular plates and switch box , excuding , modular plates as reqd |
| 150 | Wiring for sub mains long with earth wire in FRLS PVC Insulated 660/1100 volt prade flexible stranded copper conductor wires in recessed or surface conduiting system, Ind. cost of conduits Havells/ Polycab/ Finotex/ Anchor/ KEI/ AR of equivalent |
| 151 | 22.5 sq.mm 1x 2.5 sq. mm ealth wire (Lighting circult) |
| 152 | 245 sq.mm 1x 6 sq. mm earth wire (AC wiring) |
| 153 | 2x 1.5 sq.mm 1x 1.5 sq. mm earth wire (Inverter circult) |
| 154 | 4x4 sq.mm 2x 4 sq. mm earth wire (Lighting sub main) |
| 155 | 4 x 16 sq.mm 2x 6 sq. mm earth wire (Heating sub main) |
| 156 | 4 x 6 sq.mm 2x 6 sq. mm earth wire (3 Phase wiring points) |
| 157 | Supply and installation of 32A Industrial/modular plug/socket with 32A DP MCB for acs |
| 158 | Supply and fixing of 6 way (418) Double door surface/ recess mounting, Vertical/ Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, Inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer.. |
| 159 | Supply, Installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA \"C\" curve MCB of Legrand/ Havells/ L&T suitable for Inductive load in the MCB distribution board complete with necessary connections. |
| 160 | Supply, Installation, testing and commissioning of 40 A DP rating 240V, 10 KA \"C\" 12 curve MCB of Legrand/ Havells/ L&T suitable for Inductive load In the MCB distribution board complete with necessary connections. |
| 161 | Supply, installation, testing and commissioning of 40A TP&N rating 240/415V, 10 02 KA \"C\" curve MCB of Legrand/ Havells/ L&T suitable for Inductive load In the MCB distribution board complete with necessary connections. |
| 162 | Supply, installation, testing and commissioning of 63A TP&N rating 240/415V, 10 02 KA \"C\" curve MCB of Legrand/ Havells/ L&T suitable for Inductive load in the MCB distribution board complete with necessary connections. |
| 163 | Supply and Installation of 63A three phase Industrial socket with plug and 63A 08. TPN MCB for Three phase wiring points. |
| 164 | Providing/laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick. |
| 165 | Supply and fixing of ceiling rose, Incl. cost of base block and necessary 10 connections. |
| 166 | Providing of chemical earthing as per IS standards by way of digging 8 feet plt then embedding 2.5 mtr. Long Gi earthing electrode, 60 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2\" dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound. |
| 167 | Supply, Installation, testing and commissioning of 30 KVA, 3-Phase, 415V,LT, 01 Unbalanced AVR of AE, ALBA, Chinar make, operating from Input voltage of L-L=155-460V & L-N-90-265V, thereby producing the output voltage of 415V +_2% Phase to Phase and 230V +_2% Phase to Neutral. The AVR should have Inbullt Over voltage protection, Under voltage protection & Over loading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oll having required di-electric strength. The stabilizer shall be capable of smooth operation up to 10% un-balanced in the load currents complete with servo bye pass system consisting of 200A four pole manual type change over switch. The supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for two years reckoned from commissioning. The Job also Includes all applicable taxes and all carriages. |
| 168 | Supply, laying, connecting and commissioning of 150 sq. mm 3.5 core PVC 50 Insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable, Incl. cost of required al. thimbles duly crimped. (under ground). |
| 169 | Supplying and laying of DWC HDPE (Double Wall Corrugated High Density Polyethylene) pipe, 200 mm dla. (OD-200 mm & ID-175 mm) ISI marked along with all accessories like sockets, bends, couplers, etc. with fitting and cutting, Jointing, etc. (under ground), Including excavation and refilling the trench after laying the pipes.(complete Job) |
| 170 | SITC of wall/free standing floor mounted dust and vermin prool compartmentalized cubical panel for electrical Works, made out of CRCA point sheet. Other parameters required ns per (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 min above 600 mm. Lond bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coaling of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for c) Interconnection between bus bar and switch gears/cable shall be rigidly equipment/switchgear supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 171 | Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) |
| 172 | Normal Incoming |
| 173 | 250 Amp, 50 KA, FP MCCB |
| 174 | Aluminum Bus Bar 500 Amp set of 4 strips |
| 175 | ON Load Change Over Switch FP 160 amp. (Front operated) |
| 176 | Aluminum Bus Bar 300 Amp set of 4 strips |
| 177 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, etc. |
| 178 | Outgoing |
| 179 | 100 Amp, TPN MCB 10KA |
| 180 | 63 Amp, 10 KA, ΤΡΝ MCB |
| 181 | 32 Amp, 10 KA, DP MCB |
| 182 | Space for 16 way MCBs |
| 183 | Supply and fixing of fan deep made of heavy gauge sheet In RCC slabs. |
| 184 | Supply and fixing of 4\"/5\" deep Junction boxes In RCC slabs. |
| 185 | Supply, Installation, testing and commissioning of 3 star rating 1.5 Ton Inverter type split Air Conditioners sultable for operation on AC supply single phase 50Hz 230V with hermetically sealed Inverter compressor with air cooled condenser latest R410A/R-32 refrigerant fan motor, start and run capacitors, relay and over load protector Internal unit with one Indoor and one outdoor unit. The Indoor unit fitted on wall by employing sultable clamps and the outdoor unit will be placed on angle Iron stand fitted with nut/bolts outside the room to avoid noise, Including standard length of suitable size copper tubing covered with nitrile foam, topping up with refrigerant for additional length of piping If required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC Insulated copper cable and a battery operated wireless remote unit. The Job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year 06 from date of successful commissioning. (Daikin/Blue Star/LG/IFB). |
| 186 | Supply, installation, testing and commissioning of relay type voltage stabilizer 06 suitable for 1.5 Ton AC operating from Input voltage 90-260Volt thereby producing output voltage of 230volts + 3%. (4 KVA) |
| 187 | Mechanical Part |
| 188 | Fire Fighting system |
| 189 | SITC OF CO2 Gas ecylinder of 45 Kg. Material Seamless steel, manufactured as per 15:7285/1988 duly inspected and certified by [151) and approved by Deptt. of Explosive Nagpur with ISI marked. painted with red colorcomplete in all respect. |
| 190 | SITC ofOnline Monitor with normal indication Analogue LED Type is used in Gas based Fire extinguishing System to monitor the weight level agent in the cylinder. When the quantity of the gas is reduced below 10% of its original filled quantity, the alert indication (YELLOW LED) is shown to indicate panel. |
| 191 | SITC of Pneumatic Valve as per IS: 3224 |
| 192 | SITC of High Pressure Discharge Hose Pips, With Working Pressure 330 Dar/4800 PSI, Length- 600mm or as per site Requirement. (Fram Cylinder To Manifold) Short |
| 193 | SITC of High Pressure Discharge Hose Pipe. With Working Pressure 330 Bar/4800 PSI, Length- 600mm or as per Site Requirement (From Cylinder To Cylinder Pilot Line) Long |
| 194 | SITC of Non Return Valve For CO2 Cylinder Slave Non return Valve suitable for connecting between slave cylinder dishcharge hose and manifold header in CO2 fixed fire extinghusing system. The slave valve is design to prevent complete backflow of CO2 manifold. |
| 195 | SITC of CO2 Nozzle with cone horn. The nozzle releases thegas/ agent into the area to be protected. Nozzles are designed in such a way that proper flow rate is achieved throughout the discharge period |
| 196 | SITC of Seam Less Pipe (Schedule 40) with nut, bolt & all fittings for Co2 Flooding Line 50mm,40 mum, 25mm and 15mm pipe. |
| 197 | 50 mm dia |
| 198 | 40 mm dia |
| 199 | 25 mm dia |
| 200 | 20 mm dia |
| 201 | SITC of Pilot cylender of 2kg capacities complete 24 volt DC with pressure guage and gunmetal rod reqd to make system complete in all aspects |
| 202 | SITC of 15 Fabricated Manifold 80 ND hedule 40 seamless |
| 203 | MS Fabricated Stand for CO2 Gas Bank inclusive of welding. Bolting or whatever is required on the site. |
| 204 | MS Adaptar for Connection to Manifold |
| 205 | SITC of CO2 Solenoid Cylinder Valve of required size made of Brass with proper threaded part with the bursting pressure as per the site requirement Strictly as per IS 15528 |
| 206 | Providing and Fixing of ISI marked (IS:15683:2006) protable CO2 type fire extinguisher type 4.5 kg expacity, including valve, discharge hose of not less than 10 mm dia and i metre long coniplete in all respects including initiall filted CO2 gas confirming to IS: 307- 1966 & filled to a filling tate of not more than 667 and wall suspension bracket. |
| 207 | Providing and Fixing of ISI marked (IS:15683.2006) protable ABC type portable extinguisher of capacity 4 kg, dry powder type (Gas Cartridge) confirming to 15: 15683: 2006 with cylinder initially fully charged wah dry powder, IS1 marked confirming to 18:156831 2006 complete with standard discharge valve with tube, Cl bracket for wall mounting. |
| 208 | Fire alarm system |
| 209 | Gas Release Automatic fire alarm Panel for Co2 Flooding System includes complete automation for 2 Zone Fire Alarm Panel complies to IS:2189:1999, gas discharge module with binary switch timer for release delay and potential free contact to relay \"Gas Release\" signal panel. |
| 210 | Electronic Hooter with flashing type multi-Strobe for combined audio + visual alarms. |
| 211 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required |
| 212 | Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with raie of rise cum fixed temprcature (dual thermistor) type with mounting base complete with allconnection as reqd |
| 213 | Manual Release Switch |
| 214 | Manual Abort switch |
| 215 | 2 Core x 1.5 sq. mm COPPER Armoured Cable |
| 216 | Co2 Discharge Exit Sign Board including not less than 12 signs |
| 217 | Weighing Macine Panel Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail