| 1 | Demolition of stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar complete all as specified and directed. |
| 2 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 3 | Taking down cement plaster of any description including raking outjoints, hackisng for key, scrubbing down with water etc. complete all as specified and directed. |
| 4 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 5 | M&L for brick work with subclass \"B\" old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 6 | Demolition of reinforced cement concrete as in roofs, slabs, floors(other than ground floors) beams, staircases, landing, chajjas, and similar works reinforcement cut as required to facilitate as demolition complete all as specified and directed. |
| 7 | M&L for RCC 1:2:4, type B1 (using 20 mm graded stone aggregates) as in slabs on walls,Chajja, beams and columns in floors, roofs, landings, balconies, selves, canopies, deck slabs and in shelves, Manhole cover, chajja and the like etc complete all as specified and directed. |
| 8 | M&L for mild steel TMT bars 10mm dia and overs, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secured with clips including welding new to old (if required) complete all as specified and directed. |
| 9 | M&L for mild steel TMT bars5 mm dia and over upto and including 10mm dia in Stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secured with clips including welding new to old (if required) complete all as specified and directed. |
| 10 | M&L for PCC type D2 1:4:8 (40 mm greaded stone aggregate)in foundations, filling and mass concrete complete all as specified and directed. |
| 11 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stoneaggregate) 40mm thick as in floor finishing surfaces of conc topping even and smooth with using extra cement complete all as specified and directed. |
| 12 | Supply onlyglass dividing strips ,3mm thick, 38 mm wide laid in position conforming to design pattern complete all as specified and directed. |
| 13 | M&L for PCCtype 1:1.5:3 (using 20mm graded stone aggregate) as in flooring complete all specified incorporating an approval mentallic floor hardener 4% by weight of cement even and fair laid in panels finished (except metallic hardner) complete all as specified and directed.(Note: Metallic floor hardner will be measured & paid separataly) |
| 14 | M&L for 20mm thick wearproof topping as specified incorporating an approval mentalic floor hardener 4% by even and smooth without using extra cement (except metallic hardner), with spike rolling to surface or making expended metal whilst the concrete is green complete all as specified and directed.(Note:Metallic floor hardner will be measured & paid separataly) |
| 15 | Supply only metallic floor hardner complete all as specified and directed. |
| 16 | M&L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade \"A\" Thickness of concrete slab 100mm complete all as specified and directed. |
| 17 | M&L for hardcore of broken stones gauge not exceeding63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface including removal of existing loose soil complete all as specified and directed. |
| 18 | Dismantling of plain or corrugated Asbestos cement including Nanital or similar pattern roof covering complete all as specified and directed. |
| 19 | S&F 6 mm thick Asbestos cementcorrugated for semi corrugated sheetsin roofsfixed with L type and J type hook bolts etc complete all as specified and directed. |
| 20 | M&L for asbestos cement two piece adjustable plain wing ridge 6mm thick Fixed with L-type or J-type or cranked hook bolts etc complete all as specified and directed. |
| 21 | Dismantling wrought iron or mild steel work of any description not otherwise described for of any description complete all as specified and directed. |
| 22 | S&F rolled mild steel roof trusses (Framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing(Beam, tee, angle, channel or flat section) including distance pieces, cleats, etc. Gde Fe 410-W (Gde-E-250) quality-A complete all as specified and directed. |
| 23 | M&L for preparation of new steel surfaces over 10cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 24 | M&L for preparation of old painted surfaces of steel and iron of any description, over 10 cm in width or girth, not otherwise described including for all necessary preparatory work required and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 25 | M&L for RCC in 1:2:4 type B-1 using 20mm graded stone aggregate as in Fins, Fecias, louvers, parapet, railings and artificiar work exc 60 cm in height, newels, balustrade and the like complete all as specified and directed. |
| 26 | M&L for form work to faces of walls retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc vertical or to batter for flat surface and rugh finished surfaces of concrete complete all as specified and directed. |
| 27 | M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or cement concrete surfacesfinishing the surface even and smooth without using extra cement including preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 28 | M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work finished fair and even using integral waterproofing compound including Preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.Note:-Supply only of WPC shall be measured and paid separately. |
| 29 | Supply only integral water proofing compound complete all as specified and directed. |
| 30 | M&L for three coat of white wash on new plaster surface after necessary preparation of surface complete all as specified and directed. |
| 31 | M&L for preparation of newly plastered surfaces of walls priming plastered and other surfaces with alkali-resitant priming paint and applying two coats of cement base paint complete all as specified and directed. |
| 32 | Chipping and removal of spalled concrete, cracked, porous and weak concrete up to aa depth of the reinforcement rods or dpht of carbonation whichever is deeper and cleaning of the reinforcement bars and exposed concrete to remove scales by chipping, wire brushing, emery sheets etc to enable the all ides of the reinforcement and application of epoxy bonding agent to exposed old concrete surfaces,. the job shall be carried with contractors own pneumatic chipper/ manually with all required resources, tools and tackel up to the satisfaction of GE complete all as specified and directed.Note:- Payment towards application of epoxy bonding agent shall be paid under respective item. |
| 33 | Providing, mixing applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-in-charge, epoxy bonding adhesive having coverage 2.20 Sqm/Kg complete all as specified and directed. |
| 34 | Providing and plaing in position mirco concrete as per relevant ASTM/ BS/ IS having comp. strength of min. 45 mpa at 2 days of make PIDILITE/ BASF/ SIKA/ FOSROC or equivalent in coloumns and beams, which shall be pre- packed single component, chloride free, non shrink, free flow, self compacing and mixed as per manufacturer\"s spacification, including required leak proof shuttering, pre-soaking of substrate, manual application or pumping, manpower and tools and tackles complete all as specified and as directed. |
| 35 | M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor fininshes completed all as specified and directed. |
| 36 | M&L for machine cut Kota stone slab flooring, 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing (granite finish) and exposed edges of Kota stone shall be rounded complete all as specified and directed. |
| 37 | Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/pointscomplete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc complete all as specified and directed. |
| 38 | Taking down main switch / MCB DBs including MCBs etc of any size and making good distrbed surfaces to match with the existing surfaces of walls, floors etc complete all as specified and as directed. |
| 39 | M&L for point wiring using proper colour coding complete all as specified with 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor two single core cable (Red and Black colour) confirming to IS 694:1990 Part-II with and includingnon metalic rigid PVC Conduit 25mm dia medium grade with all accessories including cutting chases pinning in, for concealed conduit wiring in wall/ceiling/floor/roof etc, making good of disturbed surface not exc 15cm girth, modular sunk pressed steel terminal box not less than 2mm thick, 50mm deep, covered with frame plate with cover for 01 to 16ways suitable for modular fittings including 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor one single core cable (Green colour) confirming to IS 694:1990 Part-II as continuous earth wire connected to common earth dolly all as specified and as directed for the following:- (a) One light/fan/exhaust fan/bell point controlled by one modular switch/bell push. |
| 40 | All as per above Sch \"A\" Item No. 136 but one 3 pin modular socket outlet 5 Amp on the same board with other switch complete all as specified and directed. |
| 41 | All as per above Sch \"A\" Item No. 136 but one 3 pin socket outlet 15 Amp independent board with 4 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor single core cable (Red, Black and green colour) confirming to IS 694:1990 Part-II complete all as specified and directed. |
| 42 | M&L for modular switch, 1 way 6 Amp, 1 module complete all as specified and directed. |
| 43 | M&L for modular switch, 1 way 16 Amp, 1 module complete all as specified and directed. |
| 44 | S&F modular socket 6Amp, 2/3 pin, combined 2 module complete all as specified and directed. |
| 45 | S&F modular socket6A/16A, 2/3 pin combined 2 module complete all as specified and directed. |
| 46 | S&F ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body of size complete all as specified and directed. |
| 47 | S&F lamp holder (Batten/Angle) PVC/Polycarbonate type with back plate for batten/angle fittings, complete all as specified and directed. |
| 48 | S&F for Lamp LED ADORE PLUS 1 x 9 Watts, CDL, 3 Star rating,heat sink white with Polycarbonate diffuser, B-22 base cap, retrofit type, 220/230 volts, complete all as specified and directed. |
| 49 | S&F LED lights fitting 1x 20 Watts (T-8), 4 feet long, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed. |
| 50 | S&F LED light fitting 1x9W/1X10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size with LED Lamp 1 X 9/10watts, complete all as specified and directed. |
| 51 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size and includingGI Bracket made out from GI pipe 25/32mm dia bend to shape as required, 1.2Mtr long fixed complete all as specified and directed. |
| 52 | S&F LED flood light fittings 210 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size & IP 65/66 protection complete all as specified and directed. |
| 53 | S&F sheet metal enclosures MCB SPN DBs 8 Way, 240 Volts, 50Hz, AC, double door (12) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 200 Amp copper bus bar for phase, complete with din rail, Neutral and Earthing bar, including connection, testing and making good the disturbed surfaces complete all as specified and as directed. |
| 54 | S&F miniature circuit breaker (MCB), Single Pole & Neutral 40 to 63 Amp, rating 240V, 10 KA current carrying capacity, \"C\" curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 55 | S&F miniature circuit breaker (MCB), Single Pole 6 to 32 Amp, rating 240V, 10 KA current carrying capacity, \"B\" curve fixing in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 56 | Taking down old service connection/ UG Cable removing of site complete all as specified and directed. |
| 57 | Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm x 2 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles etc complete all as specified and directed. |
| 58 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. Note : Rates includes removing of paver blocks carefully and stack properly for refixing after laying of cables . |
| 59 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 60 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 61 | M&L for river washed and screened, dry sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I complete all as specified and directed.Note :-Only compacted thickness of sand will be measured and paid separately. |
| 62 | Supply, laying un-reinforced precast concrete cable cover class LV type 1flat size 250mm x 150 mmx 40 mm complete all as specified and directed. |
| 63 | M&L for Horizontal directional drilling (HDD) is a streeable trenchless method of Laying (installing) underground cables in a shallow arc along a 40mm/ 50mm bore path by using a surface-launched drilling rig, with minimal impact on the sorrounding area complete all as specified and directed. |
| 64 | M&L for GI pipe, light grade 40mm dia for road crossing of cable for cable protection laid in trenches or above ground surface complete all as specified and directed. |
| 65 | M&L for earthing complete with galvanized iron earth plate electrode 600 x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts check nuts galvanized iron or steel all as shown in Electrical plate No. 3 of SSR PT- I testing on completion with & incl. 15 mm bore lightgrade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) pit with pre cast RCC (1:2:4) type B1 cover slab with one handle made out of 8mm dia round bar, watering arrangement with funnel, wire mesh 20 mm bore light grade GI pipe, common salt & charcoal alternative layers, necessary excavation earth work, including earthing test point all as specified or indicated including testing on completion and directed. |