| Sl. No. | Item Description |
| 1 | Lump sum price worked out by the contractor for \"BUILDING WORKS\" as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 29 to 30 |
| 2 | Lump sum price worked out by the contractor for \"SITE CLEARANCE, EXCAVATION & EARTH WORK\"as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 31 to 32 |
| 3 | Lump sum price worked out by the contractor for \"INTERNAL WATER SUPPLY WORKS \" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 33 to 34 |
| 4 | Lump sum price worked out by the contractor for \"INTERNAL ELECTRIFICATION\"as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 35 to 39 |
| 5 | Lump sum price worked out by the contractor for \" ROAD/PATH/ CULVERT WORKS \" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 40 to 42 |
| 6 | Lump sum price worked out by the contractor for \"AREA DRAINAGE WORKS\"as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 43 |
| 7 | Lump sum price worked out by the contractor for \"SEWAGE DISPOSAL WORKS\" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 44 to 45 |
| 8 | Lump sum price worked out by the contractor for \" COMPOUND WALL, FENCING AND GATE WORKS\"as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No.46 to 48 |
| 9 | Lump sum price worked out by the contractor for \"EXTERNAL WATER SUPPLY WORKS\"as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 49 |
| 10 | Lump sum price worked out by the contractor for \"EXTERNAL ELECTRIFICATION WORKS\"as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 50 to 52 |
| 11 | Lump sum price worked out by the contractor for \"LIGHTNING PROTECTION WORKS\"as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 53 |
| 12 | Lump sum price worked out by the contractor for \"SUMMER APPLIANCES WORKS\"as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 54 |
| 13 | Lump sum price worked out by the contractor for \" ARBORICULTURE WORKS \"as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 55 |
| 14 | Sch \"A\" PART-XIV (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. |
| 15 | INTERNAL WATER SUPPLY Supply and fixing of two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia complete all as specified and directed.Make - Jaquar Cat Part No KUP- 35041PMGD (3.8 LPM) or equivalent of any make specified in Appx \"C\". |
| 16 | Supply and fixing of 15 mm dia pillar cock (Low-flow) 169 mm diacomplete all as specified and directed.Make - Jaquar Cat Part No KUP - 35001PMGD (3.8 LPM) or equivalent of any make specified in Appx \"C\". |
| 17 | Supply and fixing ofSink Cock with Regular Swinging Spout (Table Mounted Model) (Low - flow) 16 mm dia complete all as specified and directed.Make - JaquarCat Part No FLR-5357N GD (3.8 LPM)or equivalent of any make specified in Appx \"C\". |
| 18 | INTERNAL ELECTRIFICATIONS&F sheet metal enclosure,(for DB\"s when MCBs to be used), flushed in wall single pole and neutral Double door, 6 way, 240 Volts withPVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB\"s and isolators etc complete all as specified and as directed. |
| 19 | Supply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 6 poles 125 Amps, 16 KA, busbars ,neutral link, blanking plates complete with all accessories etc complete all as specified and as directed.Note:- Outgoing MCBs shall be measured and paid separately |
| 20 | Supply and fixing load line distribution board TPN vertical, 8 way double door type, fixed on wall semi flush with incoming MCCB 6 poles 200 Amps, 16 KA, busbars ,neutral link, blanking plates complete with all accessories etc complete all as specified and as directed.Note:- Outgoing MCBs shall be measured and paid separately |
| 21 | Supply and fixing amp rating 415V, 25KA \"C\" curve miniature case circuit breaker (MCCB) 4 Pole 200 Amp, current carrying capacity in the MCCB used DB complete with connection testing and commissioning completeall as specified and as directed. |
| 22 | Supply and fixing amp rating 415V, 25KA \"C\" curve miniature case circuit breaker (MCCB) 4 Pole 400 Amp, current carrying capacity in the MCCB used DB complete with connection testing and commissioning complete all as specified and as directed. |
| 23 | Supply and fixing RCCB upto 16 A, 230 V, 50 Hz, 2P, 30mA RCCB for conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 complete all as specified and as directed. |
| 24 | Supply and fixing RCCB upto 32 A, 230 V, 50 Hz, 2P, 30mA RCCB for conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 complete all as specified and as directed. |
| 25 | Supply and fixing TV sockets complete with all accessories all as specified and as directed . |
| 26 | Supply and fixing RJ 11 Gang with shutter (Telephone Jack) complete with all accessories all as specified and directed . |
| 27 | M & L for drawing 12 pair /multi core coated copper telephone cable including PVC conduit of size 20 mm complete all as specified & directed. |
| 28 | Supply and fixing high speed wall mount fanfans complete with blades, attractive colour to suit every type of interior wide oscillation, tilting mechanism, Copper winding 230 V, 400 mm sweep. Min air delivery 105CMMcomplete all as specified & directed. |
| 29 | S & F LED batten suitble for indoor application 20 W, 4\" length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable sizecomplete all as specified & directed. |
| 30 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete all as specified & directed. |
| 31 | Supply and fixing LED fitting study table type with high output diffuser 2 feet, 9W 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. |
| 32 | Supply and fixing LED Projection light fitting 35 Watt floodlight, 220V AC and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with multiple LED distributed evenly for distribution to avoid light spot, holders, connector etc. with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified & directed. |
| 33 | Supply and fixing LED security light fitting 35 Watt made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDsinbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30Woutput operating voltage 140-280V with connection by three core PVC insulatedmultistranded copper conductor sheathed cable of size 1.0 sq mmfixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & boltscomplete all as specified and as directed. |
| 34 | Supply installng, testing and commissioning floor mounted LT panel Indoor type of suitable size cubical type CPRI approved factory fabricated, dust & vermin proof made out of CRCA sheet 2.00 mm thick and angle iron frame of 40x40x6mm and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B-1 (20 mm graded stone aggregate) Powder Coated Spray painted from outside and inside complete as under. |
| 35 | (a) Aluminium bus bar rating 1.5 times of incomming MCCB rating for phase and neutral both - 04 Nos(b)MCCB Thermal based type TPN400 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. As I/Comer (01 No)(c)MCCB Thermal based type TPN 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA. As O/G 03 Nos)(d)MCCB Thermal based type TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 16 KA. As O/G 12 Nos)(e)Ammeter0-200 Amps with CT and selector switch - 01 Nos(f)Voltmeter0-500 volts with selector switch - 01 Nos(g) Indicating lamp YB - 01 Set.(h)Multifunction Meter - 01 Nos |
| 36 | COMPOUND WALL WORKSSupply and fixing of CI wheel as rollers of 75mm dia for gatescomplete all as specified and as directed. |
| 37 | EXTERNAL WATER SUPPLY WORKSSupply, laying, jointing and testing of DI (Ductile iron) pressure pipes of size 150 mm dia bore with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar laid in trenches including testing on completion complete all as specified and directed.Note:- Ductile Iron Specials/Fittings, excavation and earth work shall bemeasured and paid separately. |
| 38 | Supply, laying, jointing and testing of DI (Ductile iron) pressure pipes of size 80 mm dia bore with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar laid in trenches including testing on completion complete all as specified and directed.Note:- Ductile Iron Specials/Fittings, excavation and earth work shall bemeasured and paid separately. |
| 39 | Supplying and fixing offoot valve conforming to IS 4038, 80 mm (3\") dia complete all as specified & directed. |
| 40 | Supplying, fixing and testing of CI/DI fittings such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end taperingbellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tatering as bell mouth or flanged ) caps blank flanges heavy duty suitable for mechanical joint/flanged joint complete all as specified & directed.Note:- (i) Excavation and earthwork shall be measured and paid separately. (ii) Unit rates includes for all jointing and jointing materials.(iii) Certifiacte for Weight of fitting by the manufacturere shall be submitted before payment. |
| 41 | M&L forconstruction of brick masonarry new valve pit chamber of 1200 mm x1200 mm x 1000 mm size 100mm thick PCC 1:4:8 type D-2 lean concrete foundation using 40mm graded crushed stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6rendering in cement 1:6 finished even smooth using extra cement internally and 20mmthickin CM 1:4and finished fair and even supply and fixing of 3.15 mm thick MS sheet steel cover fixed on 50mm x 50mm x 6mm thick angle ironframe embbeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6 mm flat iron appplyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. |
| 42 | All as per Item No 17.04 above but size of 600x600x600mm complete all as specified and as directed. |
| 43 | Supply and install, test commissioning of centrifugal mono block pump set capable of discharging waterat 1430 LPM at 25 MTR head, 2900 RPM, minimum suction and delivery size as 80 x 80mm,bronze impeller, directily coupled with suitable induction motor 3 phase 415 Volt, 50 cycle,mounted on MS channel comon base frame and fixed with suitable bolt grouted in PCC foundation 1:2:4 type B-1 using 20mm graded stone aggregate 30cm above floor level including Suction and delivery pipe, galvnised iron, medium grade, 80mm dia from UG sump to NRV in delivery line with necessary flanged joints & required support & clamps for pipies, pressure gauge, Provn ofPVC insulated unshthad copper cable of suitable size 3 core multistranded in PVC counduit for connection from starter to motor with proper lugs thimbels etc including all necessary accessories complete all as specified and as directed. |
| 44 | Supply, install testing and commissioning of weather and vermin proof L.T. feeder piller box (Panel board) of size 1.5mx1.0x0.45m factory fabricated indoor cubicle/kiosk typetotally enclosed made out of 2.0 mm thick CRCA sheet metal enclosure of as per IS-8623 of suitable size with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase4 wire, 440 volts 50 HZsystem, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos ofcircular cable entry holes at bottom only with suitable PVC/rubber/ wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, powder coated of approved colour, including connection with LT armoured incomming and outgoing cables and including required sizes of cable lugs of aluminium complete all as specified and directed and consisting of following :- |
| 45 | (a) Bus bars of copper strips of 200 Amps (b) MCCB TP &N4 pole type, 25KA, 100 Amps - 01 No (incoming).(c) MPCB (Motor Protection Circuit Breaker) 32Amps, 415V, 50Hz, 3P, 10KA , with over load and short circuit protection as per IS-13947-2 - 02 No (outgoing)(d) MCB SPN 240V 32 A 10 KA (02 outgoing)(e) Indicator lamps (RYB) one set of 3 neon lamps(f)Motor ON indicating lamp (Green), Motor trip indicating lamp (Yellow), ON/OFF push button (green & red)(g) Star Delta starters Class H insulation, fully automatic, confirms to IS/IEC 60947-4-1 with protection class IP 54, suitable for 15Hp Motor - 02 Nos (h) Single phase prevonter & timer- 02 Nos(j) Combine Voltmeter & Ammeter with selector switch and CT\"s of suitable ratio - 01 set(k) Power factor improvement capacitor 10 KVAR,low loss super heavy duty hermatically sealed capacitor with switches of suitable capacity - 01 No(l) Power factor meter and controller- 01 No(m) Capacitor duty contactor 10 kVAr Rating @ 440V, 3Ph, 50Hz, type MOC10 with built in auxilary contact 1NO-01Nos(n) Full automatic Intelligent APFC controller -01Nos |
| 46 | EXTERNAL ELECTRIFICATION WORKSSupplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 400 KVA capacity transformer,including suitable plinth PCC platform (As per manufacturer drg after approval of GE) and as per site requirement, step down, outdoor type, 11000/433 volts (at no load) with system voltage 12KV all as per IS 1180 (Part 1):2014, copper wound, oil immersed, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from (+) 5% to (-) 10% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and confirming to BEE 5 Star Rating (Level 3 transfomer) as per IS 1180 (Part 1):2014 |
| 47 | (a) The core shall be stack/wound type of high grade Cold Rolled Grain Oriented or Amorphous Core annealed steel lamination having low loss and good grain properties, coated with hot oil proof Inter layer insulation of Nomex /Epoxy dotted Kraft Paper, bolted together and to the frames firmly to prevent vibration or noise. The core shall be stress relieved by annealing under inert atmosphere if required.The complete design of core must ensure permanency of the core loss with continuous working of the transformers. LV winding shall be such that neutral formation will be at top. Current density for HV and LV winding should not be more than 2.8 Ampere per sq mm (b)The maximum allowable losses at 75 °C & 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 1080watts and 3214watts respectively for 11/0.433 kV transformer without any positive tolerance all as per specified for level 3 transformer as in IS 1180 (Part-1):2014 Ammendment No 4 |
| 48 | (c) Overload capacity of transformers shall be suitable for loading as per IS 6600(d) The percentage impedance of transformers at 75 °C for 400 kVA shall be as per Table 6 of IS 1180 (Part-1) : 2014 (e) Transformer tank construction shall conform in all respect to clause 15 of IS 1180(Part-1):2014. The internal clearance of tank shall be such, that it shall facilitate easy lifting of core with coils from the tank without dismantling LV bushings. All joints of tank and fittings shall be oil tight and no bulging should occur during service. Inside of tank shall be painted with varnish/hot oil resistant paint.The top cover of the tank shall be slightly sloping to drain rain water. The tank plate and the lifting lugs shall be of such strength that the complete transformer filled with oil may be lifted by means of lifting shackle.Manufacturer should carry out all welding operations as per the relevant ASME standards. The transformer tank shall be of robust construction and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for the bottom and top and not less than 4 mm for the sides for distribution transformers with Tolerances as per IS-1852.The space above oil level in the tank shall be filled with dry air or nitrogen conforming to commercial grade of IS 1747. The tank shall further be capable of withstanding a pressure of 0.8kg/sq.cm and a vacuum of 0.7 kg/sq.cm (g) without any deformation. |
| 49 | (f) Audible sound levels for liquid immersed distribution transformers shall be 56 decibels (NEMA Standards)(g) One cable box on primary H.V side having cable glands suitable for 150Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass/ gun metal bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers.HT Cable box should prevent the ingress of moisture into the box due to rain water directly falling on the box. The cable box on HT side shall be of the split type with faces plain and machined and fitted with Neo-k-Tex or similar quality gasket and complete with brass wiping gland to be mounted on separate split type gland plate with nut-bolt arrangement and MS earthing clamp. The bushings of the cable box shall be fitted with nuts and stem to take the cable cores without bending them. The stem shall be of copper with copper nuts. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight. |
| 50 | (h) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GMbushing rods complete with GM nuts, and washers with cable gland suitable for reception of outgoing L.T. PVC sheathed armoured cables of size 2 x 300 sqmm 3.5 core . having non-magnetic material gland plate with appropriate sized single compression brass glands on LV side to terminate 1.1 kV/single core XLPE armoured cable.(j) The bushing rods and nuts shall be made of brass material 12 mm diameter for both HT and LT bushings. The bushings shall be fixed to the transformers on side with straight pockets and in the same plane or the top cover . The tests as per latest IS 2099 and IS 7421 shall be conducted on the transformer bushings.(k) OIL CONSERVATOR:The provision of conservator is mandatory with oil gauge, air release plug andbreathing device with a drain plug and a filling hole 32 mm (1¼”) normal size thread with cover. The dehydrating agent shall be silica gel. The moisture absorption shall be indicated by a change in the colour of the silica gel crystals which should be easily visible from a distance. Volume of breather shall be suitable for1Kg of silica gel conforming to IS 3401. The total volume of conservator shall be such as to contain 10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator. |
| 51 | (l) The radiators can be tube type or fin type or pressed steel type to achieve the desired cooling to limit the specified temperature rise.(m) Transformer to be painted with poly urethene/powder caoted (color light gray & DA gray) paints over anti corrosive primer & shall be free from runs, sags, wrinkles, patchiness, brush marks or other defects.All primers shall be well marked into the surface, particularly in areas where painting is evident and the first priming coat shall be applied as soon as possible after cleaning. The paint shall be applied by airless spray.(n) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, maxtemp indicator and resetting device(o) Rating plate with terninal markings.(p)Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6 m GI earth strip.(q) Lifting lugs.(r) Four plane solid cast steel detachable rollers.(s) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103. |
| 52 | (t) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral.(u)Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones insignal red colour , one at H.T side and other on L.T side.(v)Any other fittings / accessories so as to confirm the whole transformer toIS 1180 (Part 1): 2014 |
| 53 | (w) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I):(i) Location:Ahmedabad(ii)Maximum ambient air temperature:50 °C(iii) Minimum ambient air temperature :5°C(iv) Maximum average daily ambient air temperature:42 °C(v)Maximum yearly weighted average ambient temperature : 32 °CThe temperature rise over ambient shall not exceed the limits given below:(i) Top oil temperature rise measured by thermometer : 35 °C(ii) Winding temperature rise measured by resistance method : 40 °C |
| 54 | Supply, install, testing and commissioning of feeder pillar box CPRI approvedoutdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 800 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal including necessary foundation work and suitable cable glands for incomming and outgoing cables following (For Main LT Panel-I) |
| 55 | (a) Incomer(i) ) MCCB 4 pole adjustable thermal 415 volts 500 Amps 36 KA - 01 Nos(ii) Digital Amp meter 3 phase including CT ratio 100/5 (three nos of CT) including selector switch.(iii) Digital volt meter 3 phase 0-500 volts (iv) Indicating lamps LED type, 230 volts for RYB including all necessary arrangments - 01 Set(b)Out going (i) MCCB 4 Pole, 415 V, 315 Amps 35 KA - 01 No (For LT Panel -I)(ii) MCCB 4 Pole, 415 V, 200 Amps 35 KA - 02 Nos (For LT Panel -II & III)(iii) MCCB 4 Pole, 415 V, 100 Amps 25 KA- 02 (For LT Panel -IV & P House)(iv) MCB DP 40 Amps 10 KA - 03 Nos ( For Street Lights 02 Nos & Car Shed 01) |
| 56 | Supply, install, testing and commissioning of feeder pillar box CPRI approvedoutdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 400 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following (For Admn Block LT Panel I) |
| 57 | (a) Incomer(i) MCCB 4 pole 415 volts 200 Amps 35 KA - 01 Nos(ii) Digital Amp meter 3 phase including CT ratio 100/5 (three nos of CT) including selector switch(iii) Digital volt meter 3 phase 0-500 volts (iv) Indicating lamps LED type, 230 volts for RYB including all necessary arrangments - 01 Set(b)Out going (i) MCCB 4 pole 415 volts 160 Amps 25 KA - 01 Nos (For Adm Block)(ii) MCCB 4 Pole, 415 V, 63 Amps 25 KA - 02 Nos (For OR Inistitute, Spare-01)(iii)MMCB DP 40 Amps 10 KA- 03 Nos ( For R I, StoreI & II) |
| 58 | Supply, install, testing and commissioning of feeder pillar box CPRI approvedoutdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 400 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following (For Signal CentreLT Panel II) |
| 59 | (a) Incomer(i) MCCB 4 pole 415 volts 200 Amps 35 KA - 01 Nos(ii) Digital Amp meter 3 phase including CT ratio 100/5 (three nos of CT) including selector switch(iii) Digital volt meter 3 phase 0-500 volts (iv) Indicating lamps LED type, 230 volts for RYB including all necessary arrangments - 01 Set(b)Out going (i) MCCB 4 pole 415 volts125 Amps 35 KA - 02 Nos (For Signal Centre & Tech Store)(ii) MCCB 4 Pole, 415 V, 63 Amps 25 KA - 02 Nos (For Exchange &, Spare-01)(iii)MCB DP 40 Amps 10 KA- 02 Nos ( For Qtr Gd &Store II) |
| 60 | Supply, install, testing and commissioning of feeder pillar box CPRI approvedoutdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 400 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following (For SM Barrack LT Panel III) |
| 61 | (a) Incomer(i) MCCB 4 pole 415 volts 200 Amps 35 KA - 01 Nos(ii) Digital Amp meter 3 phase including CT ratio 100/5 (three nos of CT) including selector switch(iii) Digital volt meter 3 phase 0-500 volts (iv) Indicating lamps LED type, 230 volts for RYB including all necessary arrangments - 01 Set(b)Out going (i) MCCB 4 pole 415 volts125 Amps 35 KA - 01Nos (For SM Barrack)(ii) MCCB 4 Pole, 415 V, 63 Amps 25 KA - 02 Nos (For Cook House &, URC)(iii)MCB DP 40 Amps 10 KA- 01Nos (Spare) |
| 62 | Supply, install, testing and commissioning of feeder pillar box CPRI approvedoutdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 400 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following (For JCOs Club LT Panel IV) |
| 63 | (a) Incomer(i) MCCB 4 pole 415 volts 125 Amps 35 KA - 01 Nos (ii) Digital Amp meter 3 phase including CT ratio 100/5 (three nos of CT) including selector switch(iii) Digital volt meter 3 phase 0-500 volts (iv) Indicating lamps LED type, 230 volts for RYB including all necessary arrangments - 01 Set(b)Out going (i) MCCB 4 pole 415 volts 63 Amps 25 KA - 02 Nos (For JCOs Club & Spare)(ii)MCB DP 40 Amps 10 KA- 01Nos (Spare) |
| 64 | Supply and fixing automatic street light control switch for switching ON/OFF street lights based on Lux level of ambient light and comprising of Nature switch for lighting load 8KW equally distributed over 3Phase, power contactor of size32 Amps-03 Nos, Single phase, MCB SP 25 Amps-03 Nos,and support terminals enclosed in pole mountable weather proof junction box of IP 54 protection class complete all as specified and directed. |
| 65 | Supply and fixing cable Junction box, weather proof IP 66/67/69 suitable for pole mounting polysterene of size 155 x 210 x 92duly fitted with connector metric knockouts on all sides for cable entry including cable glands for cable size 10/16 Sqmm x 4 core, Clamp made of 30x5 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer suitable for steel tubular swaged poletype 410 SP-3complete all as specified & directed. |
| 66 | Supplying, installation, Connecting electrically & commissioning and testing of Outdoor type free standing type (IP -42) automatic power factor correction system with both auto and manual options type Inlet Var APFC Panel with MD - XL capacitors and MCCB as incomer factory made Non compartmentalised single unit 440 Volts 50 Hz , 3 phase 200 KVAR (Multiple of 5 KVAR) Complete all as specified and as directed including the following :(a) Double Metallized paper with polypropylene film cylinderical, type MD-XL capacitor bank of rated voltage 525 volts with detuned Reactor of de - tuning factor (P) 7% and suitable output of 200 KVAr at 440 Volts confirming to IS-13340, 13341, & IEC - 60831 - 1+2.(b) Capacitor duly contactor with Damping Resistors appropriate rating for capacitor switching confirming to IEC - 60070 & IS 13947. |
| 67 | (c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors and suitable to display of voltage , current, active power, Reactive power, Apparent power, Display of power factor, THD Voltage, THD current, alarm indication for defective steps, low power factor and excess temperature. The relay has volt free c/o contact, Automatic detection and usage of optimum capacitors.(i) Capable of 4 - Quadrant operation, and any phase offset requirement.(ii) Swithching programms : LIFO, Combi - filter, manual mode.(iii) Build in under and over voltage release with auto reset.(iv) Large Voltage input band of 90 Volt to 550 Volt , 45 - 65 Hz.(v) Current measuring 10 mA - 5A , Suitable for CT x/1A and x/5A.(vi) Commissioning without additional settings and programming.(vii) Three decimal power factor reading. |
| 68 | (d) Multifunction meter having digital volt meter and ammeter of range as required and recommended by manufacturer with in built selector switch and CTs of appropriate ratio with percentage load bar graph (Model EM 6459) equivalent.(e) MCB \"D\" , 3 Pole, 415 Volts Curve type with rupturing cap 10 kA of appropriate rating for protection of individual capacitor bank conf to IS 8828, IEC 898. (f) Incoming TPN MCCB, 400 Amps, Ics = 100% Icu , 25 KA, 4 Pole.(g) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending the temperature of the panel.(h) Emergency stop push button to disconnect the unit in case of emergency.(j) Indicator LED type for phase indication and capacitor banks ON and OFF indication. (k) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to withstand high temperature, housed in cubical panel (CPRI Approved) made out of 3.15 mm thick MS sheet factory made duly powder coated front and rear door openable with locking arrangement complete with foundation as required or recommended by manufacturer. |
| 69 | Supply, installation, testing and commissioning of 11 KV, 630 Amps, having short circuit capacity 21 KA for 3 Sec Outdoor (IP54), RMU (Ring main unit) 3 – way comprising of 01 Nos. motorized operated load breaker switch and 2 nos. 630 Amps fixed type motorized spring charging VCB electrolytic grade copper busbars all inside single, gas filled,welded stainless steel 304/441 or better IP 67 Degree of Protection tank with min thickness , 2 to 2.5 mm thick for load bearing member and 1 to 1.6 mm for non load bearing member, internal arc classification, 21 KA for 1 sec on site repairable with site replicable / coupling / mechanism,etc. The enclosure shall have pad lockabledoors as per OEM design, fully covering the front facia and cable boxesensure fail safe anti theft protection. The unit along with Bus connected, fixed type Auxiliary transformer shall include the following along with all necessary accessories and fittings are required at site |
| 70 | (A)Incoming Load Break Module - 01 Nos each consisting of following accessories:(i) Each switching – unit is designed as a three position switch. This three function switch combines the function of switch – disconnector an earthing switch(ii) 11 KV, 630 A Load Breaker Switch with interlocking line -earthing scheme both short circuit current ,21 KA for 3 Sec Making capacity – 50 KAp- 01 No(iii) Auxiliary contacts – 1 NO + 1 NC- 01 No.(iv) Spring – assisted motorized mechanism with un-inhabited operating shaft for emergency manual operation with integrated earthing switch – 01 No(v) Cable terminals cable bushing situated not beyond 300 mm or as per ORM tested design from cable cover to allow ease of access for installation /testing/replacement purpose) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access of size upto 11 KV, 300 Sq mm, 3 Core, along withXLPE AL cable termination/ End Kits Each set of 03 . |
| 71 | (vi) Right angle boots (push on type) Each set of 03 (vii) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No.(viii) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set(ix) Fault passage indicator – It is to be provided for each incomer Load break unit, FPI with LED / digital display to be added to detection of cable fault – 01 No(x) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 NoCable cover standard - 01. (B)02 Nos., outgoing VCB module each consisting of following accessories: -(i)Each function – unit consists of a vacuum – circuit breaker in combination with a three position – switch. The three-position switch fulfils the operation of the disconnector – function and earthing function. |
| 72 | (ii)11 KV, 630 Amps Fixed type VCB module with series disconnector cum earthing switch of short circuit breaking current / withstand –, 21 KA for 3 Sec Making Capacity – 50 KAp- 01 No(iii)Auxiliary contacts – 1 NO + 1 NC- 01 No.(iv)Stored – energy motorized high – endurance spring charging mechanism (M1+), with inbuilt spring charging lever and mechanically latched ON/OFF push -buttons to allow handle – less and un-inhabited operation – 01 Nov) Cable terminals cable bushing situated not beyond 300 mm or as per OEM tested design from cable cover to allow ease of access for installation/testing/replacement purpose) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access up to 11 KV, 185 Sq mm, 3 Core, along with XLPE AL cable termination Each set of 03vi)Right angle boots (push on type) Each set of 03 vii)3 O/C + 1 E/F self-powered numerical protection relay with low and high set for Over current and Earth Fault. Relay should have facilities to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol. – 01No/ per VCB ougoingviii)Relay for OTI / WTI / B – relay protection – 01 No |
| 73 | ix) Associated ring Core cast- resin insulated CT s 50/1 Amps, 2.5 VA, 10 P 10 Protection - Each set of 3x) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No.xi) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Setxii) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 Noxiii) Emergency trip push button – 01 No(C) 01 No Bus – connected, fixed – type Auxiliary transformer with floor- mounted compartment of matching height and depth, positioned along – side RMU to provide required aux. supply for spring charging motor and metering consisting of following accessories:(A) Set of 03nos. single-phase potential transformers having ratio 11kV/rt3:110V/rt3, 25VA, Class 1.0 with HRC fuses for protection on primary side and MCBs for protection on secondary side.- 01 Nosi) 1-Ph (11 KV / rt3): 230 VAC, 500 VA Auxiliary transformer – 01 Noii) 2X12 Volt DC battery – 01 Setiii) Battery charger – 01 No, with indiacation of status of functioning |
| 74 | iv) HRC fuse links for primary side isolation and AC/DC MCBs for secondary isolation – 01 Setv) Voltmeter & RYB LED indications to confirm AC/DC supply availability – 01 Setvi) Anti – condensation space – heater – 01 Novii) CFL lamp for illumination and 3 pin socket with switch – 01 No(D)Standard mano meter -01 for each tank, Operating handle - 02 , cable clamping provision(standard)-01 /for every cbale enrty ,Operation and maintance manual - o1, installation and commissioning manual - 01, Foundation as per OEM Recomendation (Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.45 mtrs from ground level.NOTE : (a) The above moduleconsisting of Load break Switchs andVCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on platform as recommended by OEM complete. |
| 75 | Supply, install, testing and commissioning of HT 11KV, 3 Phase, 50 Hz, totally enclosed, outdoor type metal clad switchgear having rupturing capacity upto 630A, RMU (Ring main unit) 2-way comprising of 01 Nos. motorized operated load breaker switch and 01 Nos. 630 Amps fixed type motorized spring charging VCB electrolytic grade copper busbars all inside single, gas filled,welded stainless steel 304/441 or better IP 67 Degree of Protection tank with min thickness , 2 to 2.5 mm thick for load bearing member and 1 to 1.6 mm for non load bearing member, internal arc protection classification, 21 KA for 1 sec on site repairable with site replicable / coupling / mechanism,etc. The enclosure shall have pad lockabledoors as per OEM design, fully covering the front facia and cable boxesensure fail safe anti theft protection. The unit along with Bus connected, fixed type Auxiliary transformer shall include the following along with all necessary accessories and fittings are required at site |
| 76 | (A)Incoming Load Break Module - 01 Nos each consisting of following accessories:(i) Each switching – unit is designed as a three position switch. This three function switch combines the function of switch – disconnector an earthing switch(ii) 11 KV, 630 A Load Breaker Switch with interlocking line -earthing scheme both short circuit current ,21 KA for 3 Sec Making capacity – 50 KAp- 01 No(iii) Auxiliary contacts – 1 NO + 1 NC- 01 No.(iv) Spring – assisted motorized mechanism with un-inhabited operating shaft for emergency manual operation with integrated earthing switch – 01 No(v) Cable terminals cable bushing situated not beyond 300 mm or as per ORM tested design from cable cover to allow ease of access for installation /testing/replacement purpose) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access of size upto 11 KV, 300 Sq mm, 3 Core, along withXLPE AL cable termination/ End Kits Each set of 03 . |
| 77 | (vi) Right angle boots (push on type) Each set of 03 (vii) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No.(viii) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set(ix) Fault passage indicator – It is to be provided for each incomer Load break unit, FPI with LED / digital display to be added to detection of cable fault – 01 No(x) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 NoCable cover standard - 01. (B)01 Nos., outgoing VCB module each consisting of following accessories: -(i)Each function – unit consists of a vacuum – circuit breaker in combination with a three position – switch. The three-position switch fulfils the operation of the disconnector – function and earthing function. |
| 78 | (ii) 11 KV, 630 Amps Fixed type VCB module with series disconnector cum earthing switch of short circuit breaking current / withstand –, 21 KA for 3 Sec Making Capacity – 50 KAp- 01 No(iii) Auxiliary contacts – 1 NO + 1 NC- 01 No.(iv) Stored – energy motorized high – endurance spring charging mechanism (M1+), with inbuilt spring charging lever and mechanically latched ON/OFF push -buttons to allow handle – less and un-inhabited operation – 01 No(v) Cable terminals cable bushing situated not beyond 300 mm or as per OEM tested design from cable cover to allow ease of access for installation/testing/replacement purpose) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access up to 11 KV, 185 Sq mm, 3 Core, along with XLPE AL cable termination Each set of 03(vi)Right angle boots (push on type) Each set of 03 |
| 79 | (vii)3 O/C + 1 E/F self-powered numerical protection relay with low and high set for Over current and Earth Fault. Relay should have facilities to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol. – 01No/ per VCB ougoing(viii)Relay for OTI / WTI / B – relay protection – 01 No(ix) Associated ring Core cast- resin insulated CT s 50/1 Amps, 2.5 VA, 10 P 10 Protection - Each set of 3(x) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No.(xi) Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set(xii) ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 No(xiii) Emergency trip push button – 01 No |
| 80 | (C) 01 No Bus – connected, fixed – type Auxiliary transformer with floor- mounted compartment of matching height and depth, positioned along – side RMU to provide required aux. supply for spring charging motor and metering consisting of following accessories:(iii) Set of 03nos. single-phase potential transformers having ratio 11kV/rt3:110V/rt3, 25VA, Class 1.0 with HRC fuses for protection on primary side and MCBs for protection on secondary side.- 01 Nos(i) 1-Ph (11 KV / rt3): 230 VAC, 500 VA Auxiliary transformer – 01 No(ii) 2X12 Volt DC battery – 01 Set(iii) Battery charger – 01 No, with indiacation of status of functioning(iv) HRC fuse links for primary side isolation and AC/DC MCBs for secondary isolation – 01 Set(v) Voltmeter & RYB LED indications to confirm AC/DC supply availability – 01 Set(vi) Anti – condensation space – heater – 01 No(vii) CFL lamp for illumination and 3 pin socket with switch – 01 No |
| 81 | (D)Standard mano meter -01 for each tank, Operating handle - 02 , cable clamping provision(standard)-01 /for every cbale enrty ,Operation and maintance manual - o1, installation and commissioning manual - 01, Foundation as per OEM Recomendation (Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.45 mtrs from ground level.NOTE : (a) The above moduleconsisting of Load break Switchs andVCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on platform as recommended by OEM complete. |
| 82 | Material and labour for burnt bricks sub class B layed in trenches for cable protection complete all as specified and directed. |
| 83 | Supply, install, testing and commissioning of outdoor type factory assembled diesel driven generating set with silent (acoustic) enclosure with fully wired alternator AC for ambient conditions at Ahmedabad (at site) to give output of 125 KVA (100 KW) continuous rating at power factor 0.8,415 volts + 2.5% AC 3 phase, 4 wire, 50 Hz + 1 %, 1500 rpm directly coupled with diesel engine water cooled mounted on common base frame placed on & including PCC platform with floor mounted Fuel Tank of adequate capacity with fuel lines, anti vibration pads, standard control & AMF panels and other accessories etc complete all as specified & directed consisting of following :- (Note:- The capacity of generating set shall be net after accounting derating factors as per relevant ISI design) |
| 84 | (A) Prime Mover (Diesel Engine) :- Adequate capacity diesel engine of standard design consist of direct injection type, turbo charged four stroke, liquid cooled technology conforming to BS 5514 and IS 10000 suitable for prime duty generating set 125KVA / 100 KW of suitable BHP @ 1500 RPM with multi cylinders to drive independently alternator and considering derating as per site condition after generating and reducing power consumed by accessories, directly coupled through coupling having overload capacity of 10% for one hour in every 12 Hrs continuous runningmounted on base frame withfollowing salient features and standard accessories for safe handling & operation of engine as under:-(a) The gen set should have capacity to run continously in variable load condition for unlimited hoursand should also have a 110% load capacity of 01 hour in every 12 hours of operation.(b) Air System - Inlet & Exhaust comprising (i) Dry-type paper element air Cleaner (ii) Restriction Indicator / Vacuum Indicator (iii) Optimised Turbocharger (iv) Intake Manifold (v) Exhaust Manifold (vi) Silencer mufflerand (vii) Stainless steel Exhaust Flexible coupling, complying to latest regulations & emmission control norms of CPCB. |
| 85 | (c) Cooling System comprising (i) Radiator to suitambient conditions (ii) Cooling system piping (iii) Thermostat (iv) Pressure cap(v) Coolant Inhibitor and (vi) Engine Driven Fan(d) Fuel System comprising (i) Fuel pump -Low pressure type (ii) Injectors (iii) Cartridge paper filters primary and secondary for Fuel (e) Governor :- Engine Electronic Governor for A1 governing of engine speed from No load to full load.(f) Lub OilSystem :- (i) Plate Type lub oil cooler (ii)filters-lubrication oil.(g) Electric Starting system comprising (i) Electrical starter - 12 Volts (ii) Engine driven battery charging alternator (iii) Cut Out and (iv) OneNo of 12 volts of 150 AH maintenance free battery with suitable connection terminals and leads for proper battery connection (h) Engine Monitoring, Protection andDiagnostics relay suitable to display following(i) Lub oil Pressure (ii) Coolant Temperature (iii) Engine Speed (iv) Hours Run (v) Battery Voltage, Battery charging voltage (vi) Fuel level in percentage, |
| 86 | (vii) AC Voltage 3 phase (viii) Current RYB 3 phase (ix) Power Factor (x) Frequency (xi) KVA (xii) Kilowatt andsuitable for (i) Start and Stop (ii) Common Shutdown (iii) High coolant temp warning and shutdown (iv) Low lube oil pressure warning and shutdown (v) Low fuel level shutdown (vi) Overspeed shutdown (vii) Alternator Protection (viii)Over voltage (ix) Under voltage (x) Over and under frequency (xi) Over current (j) Engine fitted with low lube oil pressure (LLOP) & high water temperature (HWT) Safety devices and also fitted with requisite temperature and pressure gauges.(k) Misc Accessories i.e - (i) Flywheel Housing (ii) Flywheel (iii) Anti-vibration pads (iv) Emergency stop push button etc all as required for smooth operation of DG set as recommended by manufactrurer.(B) ALTERNATOR :- Self excited, self regulated screen protected drip proof type with Class \"H\" Insulation Salient pole revolving field andelectronic Automatic Voltage Regulator for voltage regulation of + 0.5% from No load to full load, standard enclosure 415 Volt 50 HZ 4 pole 125KVA cap complete as per IS-13364-2 and conf to IS-4722 or BS 2613-1970 all as required or recommended by manufactrurer. |
| 87 | (C) BASE FRAME :-Made of ISMC fabricated and welded construction channel duly painted for mounting Engine and Alternator all as per manufacturer\"s design along with specially designed in built vibration pads.(D) LT Control & AMF Panel:-AMF panel board free standing floor mounted factory made outdoor type made out of CRCA sheet 3.15 mm thick totally enclosed, weather dust and vermin proof with front opening, 440 volts 3 phase 4 wire 50 Hz having aluminium bus bar of suitable capacityfor three phases and neutral duly powder coated with coloured heat shrinkable PVC sheelves, Multifunctional digital controler relay for AMF operation and display of electrical parameters, manual/ auto Start/Stop facility, Two Nos Electrically operated modular contactor 4 pole of suitable capacity for DG set and Main supply (auto shifting of electrical load is required), 250 Amps MCCB FP- 01 No for load, and provision of Overload protection relay, Phase sequance and Single phase prevention, High voltage and under voltage protection arrangements for Contactors complete all as specified, with on/off controller indicator, Phase Indicators, engine start push button, engine stop push button and fault accept / reset push button including battery charger comprising transformer, rectifier, resistance, DC volt meter DC Amp meter and charge rate selector switch, all accessories prewired with suitable size copper conductor cable or strip all as required or recommended by manufacturer. |
| 88 | (E) Acoustic Enclosure (CANOPY) :- Shall conform to Central Pollution Control Board (CPCB) norms of 75 dBA at one metre under free field conditions, having air inlet louvers specially designed to operate at rated load even at ambient conditions on air inlet temperature,powder coated for long lasting service life and superior finish with UV resistant powder coating to with stand extreme environments, designed to have minimum ease for unloading & shifting , i.e with central lifting facility,rust free hardware made of stainless steel, Insulation material to meetIS:8183 specifications. (F) Fuel Tank :- Draw out type integral fuel tank made of MS sheet (duly painted) of capacity min 200 ltrs or as recommended by manufacturer with level indicator in ltrs,provided with drain plug and air vent / breather and inlet and outlet connections.(G) Foundation :- Size and type of PCC platform for mounting DG Set and AMF Panel required to be constructed as per manufacturer\"s specification or as recommeded by Engr - in - Charge.(H) Arrangement of POL for testing of DG Set done by the contractor and rates deemed to be included in quoted rate.(J) Two years Maintenance Spares and tools for basic maintenance shall be provided by the contracter as specified in PS |
| 89 | SUMMER APPLIANCESWORKSSupply and fix Desert cooler electric driven (single phase), having nominal air flow capacity of 4000 Cum per hour Steel Body made up of Galvanized steel sheet (ISI marked to IS 277 latest) with zinc coating not less than 100gms/sq.meter. 0.8mm Sheet Thickness for Filter panel, Grill, Top of cooler body, cabinet and 1mm thick for water Sump tank. All internal surfaces of Steel Body Cooler shall be Painted with Water Resistant paint. fan motor having power factor 0.9 minimum, operated on 230Volt, 50Hz, ISI marked (IS: 996 latest) and controled with 03 Step regulator, Aluminium fan blade suitable for 4000Cum capacity. 15mm thick Synthetic Honeycomb pads or higher with non corrosive wire guard, 2.5 Mtr Length ISI marked connecting cable with 3-pin moulded Plug Top, 5/6 Amps and Float valve at inlet complete all as specifiedand directed.NOTE : The quated rate shall includes for the following :- (a) Three speed swich ISI Marked rotary type for propeller fan and one way switch pum with separate control. The switches shall have marking off-Low-medium and high.(b) Float valve on water on water supply connection.(c) Stop Cock for sutiable size before the float valve is deemed to include in the item rate.(d) PVC connection of suitable length from stop cock to float valve etc.(e)angle Iron Stand of suitable size. |
| 90 | Supply, installed and testing of refrigrators,electric driven (single phase),capacity uuto 310 ltrs ofBEE 5 stars rated , frost free,humidity control and deoderizer, toughned glass shelves, stabilizer free operation, inverter technilogy compressor ,rust resistance body, dual thermostste for refrigeretor & freezer , with cool pack, complete all as specified and directed |
| 91 | RAIN WATER HARVESTING Construction of \"Rain Water Harvesting Pit\" as per TD Drg No CE (Fy) Hyderabad TD/STR/14 complete all as specified. |
| 92 | DEMOLITION AND DISMANTLING WORKSDemolition/dismantling of (building No P-3A, P-3C, P-1, P-2, P-2C, P-1C, NP-66, P-6, P-75, NP-138, NP-139, NP-137, NP-135, NP-136, NP-134, NP-72, P-3C2, P-67, P-66, P-5, P-5J, NP-69, P-189, P-605, P-76 and Fencing) any discripition and in any position excluding E/M fittings & fixtures complete \"As is where is\" all as specified and directed. |
| 93 | NOTE FOR ITEM No 20.00:- The quoted rate shall deemed to include the following:-(i)The demolition of Bldg shall be carried out upto ground level bearing all safety aspects into consideration including overlap with near by Bldgs and making good the ground.(ii) The quoted rate shall be deemed to include demolition of Bldgs except taking down/dismantling internal fittings and accessories of internal electric supply and internal water supply & all other items of demolition & dismantling of Bldgs specified eleswhere in the tender documents.(iii) Schedule of demolition/dismantling shall be decided by GE in the manner to recieve the amount of recovery for credit from RAR\"s/ Final bill.(iv) Demolition of the buildings shall be carried out after taking down of all internal fittings/fixtures & after necessary approval of GE.(v) The quoted rate shall be deemed to include for removal of debries obtaind to out side MOD land including loading & unloading at destination as directed by Engg-in-Charge.(vi) All safety precautions shall be taken by contractor during demolition/dismantling of buildings as per latest by laws and as specified in SSR Part-I. |
| 94 | ARBORICULTUREM&L for filling the excavated area with good yellow soil mixing with sand, festicides ATT providing ATTand appropriate fertilizers levelling etc. complete all as specified and directed. |
| 95 | S&F CP sprinkler suitable for 15 mm bore pipe along with adjustable stand of height 30 to 45 cm with all arranglents complete all as specified and directed. |
| 96 | Supply and laying of lawn grass plantation of semi carpet grass of approved quality turfs side by side without undualation/depressions and ramming the surfacecomplete all as specified and directed.Note:- Grassing shall be carried out to carpenting effect i.e. installation 80% of the ground shall not be visible due to plant cover if the desired effect is not obtained then additional grass will be planted as specified to achieve the effect. |
| 97 | Supply and planting of below mentioned trees of Casuarinain 0.25 - 0.3 M poly bags with height 1.5 M to 1.8 Mtr including digging holes 1.2 M diax 1.2 Mtr deep in ordinary soil and reffiling the same with the excavated earth mixed with manure or sluldge in the ratio 2:1 (02 parts of stacked volume of earth after reduction of 20% with 1 parts of stacked volume of sludge of manure after reduction by 80% flooding with water and removed of surplus soil and rate including maintaining the plants for 2 yearsfrom the certified date of completion of work complete all as specified and direcetd. |
| 98 | All as per item No 21.03 above but Canary date palm plant of sapling 1.50 to 1.80 m height |
| 99 | All as per item No 21.03 above but Amaltas plant of sapling 1.50 to 1.80 m height |
| 100 | All as per item No 21.03 above but Neem plant of sapling 1.50 to 1.80 m height |
| 101 | All as per item No 21.03 above but Gulmohar of sapling 1.50 to 1.80 m height |
| 102 | All as per item No 21.03 above but Kesia (Cassia) of sapling 1.50 to 1.80 m height |
| 103 | All as per item No 21.03 above but Kamuj of sapling 1.50 to 1.80 m height |
| 104 | All as per item No 21.03 above but Ashoka of sapling 1.50 to 1.80 m height |
| 105 | All as per item No 21.03 above but Jasmine |
| 106 | All as per item No 21.03 above but Alstonia |
| 107 | All as per item No 21.03 above but Bottle Brush |
| 108 | All as per item No 21.03 above but Rose |
| 109 | All as per item No 21.03 above but Bouganvillea |
| 110 | All as per item No 21.03 above but Bettle Nut |
| 111 | S & F of M.S Tree Guard 1.50 Mtrs high above with MS wiremesh of size 78 x 37 mm and 2 mm dia of wire and MS angle iron 20 x 20 x 3 mm verticals (3 Nos) & MS flats 14 x 3 mm around the tree guard (3 Nos top , middle and bottom) equally spaced and embedded vertical angles in PCC 1: 3:6, type B-I including excavation in post holes and removal of excavated material to a n.exc 5 mtr and applying two coats of synthetic enamel paint including one coat of red oxide primer to tree guard and all as specified and directed. |
| 112 | NOTES FOR ITEM NO 21.02 to 21.16 :- (i) Height of plant shall be measured from top of follage (not from the isolated branch / leaf, main stem) to 150 mm from top of root. (ii) Water will not be supplied by MES for arboriculture. Contractor has to make his own arrangement for watering to plants and grass. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants / grass till two years after certified date of completion of work.(iv). During two years after completion if any plant / grass is found dead or not of satisfactory growth, plants / grass of approved size and shape shall be provided without any extra cost to the Govt.(v). Supply and application of manure, sweet earth and pesticides, fertilizers etc up to two years after completion are deemed to be included in the quoted unit rate.(vi) In case of failure by the contractor to maintain the plants / grass as above, the same shall be carried out by the department at his Risk and Cost.(vii) The plants shall be brought at site Six months before the date of completion of the work as per Work order. |
| 113 | NOTE FOR SCHEDUL OF CREDITRs (-) 11674436.00 AMOUNT DEDUCT FROM TOTAL QUOTED AMOUNT AT TIME OF ACCPTANCE OF TENDER. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |